Citations

Clear

16 citation(s) found for "Shelly Cohen, Michal".

Deep learning for atrioventricular regurgitation diagnosis: an external validation study
Cohen, I C, Malins, J G, Cohen-Shelly, Michal , Asaf, Yossi, Fiman, Michael, Faierstein, Kobi , Sudri, Karin , Zimlichman, Eyal, Schwammenthal, E S, Klempfner, R, Maor, Elad, Malins, Jeffrey G. , Cohen, M, Schwammenthal, Ehud, Klempfner, Robert , Maor, Elad

Mayo Clinic

European Heart Journal | February 5, 2026 | Volume: 46 | Issue: Supplement_1 | Pages: No page available

10.1093/eurheartj/ehaf784.2337 Get It

Abstract Background Mitral regurgitation (MR) and tricuspid regurgitation (TR) are prevalent valvular heart diseases associated with significant morbidity and mortality. Traditional echocardiography faces limitations in availability, cost, consistency, and reliability, leading to misdiagnosis and undertreatment. The application of artificial intelligence (AI) to echocardiographic scans has the potential to address these challenges. Methods This study evaluates the performance of an AI algorithm on an external population. The algorithm utilizes deep learning networks to analyze echocardiographic exams for diagnosing atrioventricular valve disorders. We tested the algorithm on transthoracic echocardiography data collected from a single center between 2013 and 2023. The model's performance was compared to ground truth values using two classification schemes: distinguishing between normal-mild and moderate-severe regurgitation, and categorizing results into four groups: normal, mild, moderate, and severe. Results The MR cohort included 280 patients, while the TR cohort comprised 298 patients. The model demonstrated a robust ability to identify clinically significant (moderate and above) atrioventricular valve regurgitation. The MR model achieved an area under the curve (AUC) of 0.98 (95% CI: 0.97–0.99), with 91% accuracy, 95% sensitivity, and 89% specificity. In comparison, the TR model exhibited an AUC of 0.96 (95% CI: 0.94–0.98), with 84% accuracy, 91% sensitivity, and 80% specificity. Conclusion The model demonstrated high diagnostic accuracy and reliability in assessing atrioventricular valve regurgitation severity, highlighting its potential as a valuable clinical tool. The findings underscore the role of AI in complementing expert evaluations and improving access to effective diagnostics, with future applications potentially including point-of-care diagnosis and monitoring of disease progression.
Deep learning for atrioventricular regurgitation diagnosis: an external validation study
Cohen, Ido , Malins, Jeffrey G. , Cohen‐Shelly, Michal , Asaf, Yossi, Fiman, Michael, Faierstein, Kobi , Fisher, Lior , Sudri, Karin , Raanani, Ehud , Schwammenthal, Ehud, Klempfner, Robert , Maor, Elad , Maor, Elad

Mayo Clinic

European Heart Journal - Digital Health | July 14, 2025 | Volume: 6 | Issue: 5 | Pages: 949-958

10.1093/ehjdh/ztaf078 | PMID 40984997 Get It

Abstract Aims Mitral and tricuspid regurgitation (MR and TR) are common in older adults and associated with substantial morbidity and mortality. While transthoracic echocardiography (TTE) is the diagnostic gold standard, access remains limited in many care settings. Artificial intelligence (AI)–based echocardiographic analysis may help address this diagnostic gap. Methods and results We externally validated a deep learning algorithm developed by Aisap.ai using TTE studies from the Mayo Clinic Health System (2013–23). The model analyses echocardiographic images to classify atrioventricular regurgitation severity and was evaluated against cardiologist interpretations. Performance was assessed using binary (normal–mild vs. moderate–severe) and ordinal (normal, mild, moderate, severe) classification schemes. Among 1541 eligible TTEs, the model returned predictions for 578 studies (38%). Performance analysis was limited to these cases. The MR cohort included 280 studies and the TR cohort 298. For MR, the model achieved an area under the receiver operating characteristic curve (AUC) of 0.98 [95% confidence interval (CI): 0.97–0.99], with 91% accuracy, 95% sensitivity, and 89% specificity. For TR, the AUC was 0.96 (95% CI: 0.94–0.98), with 84% accuracy, 91% sensitivity, and 80% specificity. Conclusion In cases where a prediction was generated, the model demonstrated high diagnostic performance in identifying clinically significant atrioventricular regurgitation. These findings support the feasibility of AI-assisted echocardiography in diverse populations, while underscoring the need for technical alignment between model requirements and local acquisition practices to ensure real-world applicability.
Enhancing Coronary Revascularization Decisions: The Promising Role of Large Language Models as a Decision-Support Tool for Multidisciplinary Heart Team
Sudri, Karin , Motro-Feingold, Iris, Ramon‐Gonen, Roni , Barda, Noam , Klang, Eyal , Fefer, Paul , Amunts, Sergei , Attia, Zachi I. , Alkhouli, Mohamad , Segev, Amitai , Cohen-Shelly, Michal , Barbash, Israel M. , Attia, Zachi I , Barbash, Israel Moshe , Alkhouli, Mohamad

Mayo Clinic

Circulation: Cardiovascular Interventions | November 6, 2024 | Volume: 17 | Issue: 11 | Pages: No page available

10.1161/circinterventions.124.014201 | PMID 39502077 Get It

BACKGROUND: While clinical practice guidelines advocate for multidisciplinary heart team (MDHT) discussions in coronary revascularization, variability in implementation across health care settings remains a challenge. This variability could potentially be addressed by language learning models like ChatGPT, offering decision-making support in diverse health care environments. Our study aims to critically evaluate the concordance between recommendations made by MDHT and those generated by language learning models in coronary revascularization decision-making. METHODS: From March 2023 to July 2023, consecutive coronary angiography cases (n=86) that were referred for revascularization (either percutaneous or surgical) were analyzed using both ChatGPT-3.5 and ChatGPT-4. Case presentation formats included demographics, medical background, detailed description of angiographic findings, and SYNTAX score (Synergy Between Percutaneous Coronary Intervention With Taxus and Cardiac Surgery; I and II), which were presented in 3 different formats. The recommendations of the models were compared with those of an MDHT. RESULTS: ChatGPT-4 showed high concordance with decisions made by the MDHT (accuracy 0.82, sensitivity 0.8, specificity 0.83, and kappa 0.59), while ChatGPT-3.5 (0.67, 0.27, 0.84, and 0.12, respectively) showed lower concordance. Entropy and Fleiss kappa of ChatGPT-4 were 0.09 and 0.9, respectively, indicating high reliability and repeatability. The best correlation between ChatGPT-4 and MDHT was achieved when clinical cases were presented in a detailed context. Specific subgroups of patients yielded high accuracy (>0.9) of ChatGPT-4, including those with left main disease, 3 vessel disease, and diabetic patients. CONCLUSIONS: The present study demonstrates that advanced language learning models like ChatGPT-4 may be able to predict clinical recommendations for coronary artery disease revascularization with reasonable accuracy, especially in specific patient groups, underscoring their potential role as a supportive tool in clinical decision-making.
Abstract 14178: Artificial Intelligence (AI)-ECG Derived Biological Age Identifies Accelerated Aging in the Lamin A/C Gene ( LMNA ) Mutations
Shelly, Shahar, Milone, Margherita , Chacin‐Suarez, Audry , Cohen‐Shelly, Michal , Medina-inojosa, Jose, Chahal, Anwar, Friedman, Paul A. , Lopez‐Jimenez, Francisco, Medina‐Inojosa, José R. , Kapa, Suraj , Attia, Zachi I. , Somers, Virend K. , López-Jiménez, Francisco

Mayo Clinic

Circulation | April 23, 2024 | Volume: 144 | Issue: Suppl_1 | Pages: No page available

10.1161/circ.144.suppl_1.14178 Get It

Introduction: LMNA encodes the nuclear envelope proteins lamin A/C that are involved in ageing processes. Mutations in LMNA cause a spectrum of phenotypes which include muscular dystrophy, arrhythmogenic dilated cardiomyopathy, peripheral neuropathy, progeroid syndrome and overlap syndrome. Early diagnosis is crucial to prevent sudden cardiac death. We hypothesized that LMNA mutations result in an ECG biological age older than chronological age. Methods: In this study, we used AI-enabled ECG network to investigate standard digital 12-lead ECGs in genetically characterized LMNA patients. Results: We identified 33 LMNA patients with 331, 12-lead ECG available for analysis. Median age at symptoms onset was 23.5 (range: <1 to 61 years;15 females). Mean follow up time was 86 months (range: <1 to 367 months). Symptoms at onset included muscle weakness (n=10) or cardiac symptoms (n=18) and asymptomatic (n=5). We included a total of 1532 age sex matched controls. We found significant differences in positive age-gap (biologically older than chronological age) comparing LMNA patients (median of 17.5) versus controls (4.9 years; p<0.001, Figure 1 ). AI-ECG age with 10 years or higher age-gap was observed in 73% of LMNA patients compared to 27% in the controls (p<0.001). Consecutive serial analysis for all ECG’s in the study versus predicted age showed faster aging when comparing the rates of age-gap overtime in the LMNA group compared to controls (p<0.0001, Figure 2 ). Moreover, the subset analysis of 23 ECG in the 5 asymptomatic patients versus controls also showed significantly higher AI-ECG age-gap (p=0.004) Conclusions: An AI-ECG algorithm to detect biological age effectively demonstrates accelerated aging in patients with LMNA mutations related to physiological aging. Our findings further validate the role of AI-ECG to detect accelerated aging, expanding previous studies demonstrating higher mortality among individuals with in increased positive age-gap.
Machine learning in cardiac stress test interpretation: a systematic review
Barzilai, Dor Hadida , Cohen-Shelly, Michal , Sorin, Vera , Zimlichman, Eyal , Massalha, Eias , Allison, Thomas G. , Klang, Eyal , Hadida Barzilai, Dor

Mayo Clinic

European Heart Journal - Digital Health | April 17, 2024 | Volume: 5 | Issue: 4 | Pages: 401-408

10.1093/ehjdh/ztae027 | PMID 39081945 Get It

Abstract Coronary artery disease (CAD) is a leading health challenge worldwide. Exercise stress testing is a foundational non-invasive diagnostic tool. Nonetheless, its variable accuracy prompts the exploration of more reliable methods. Recent advancements in machine learning (ML), including deep learning and natural language processing, have shown potential in refining the interpretation of stress testing data. Adhering to Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines, we conducted a systematic review of ML applications in stress electrocardiogram (ECG) and stress echocardiography for CAD prognosis. Medical Literature Analysis and Retrieval System Online, Web of Science, and the Cochrane Library were used as databases. We analysed the ML models, outcomes, and performance metrics. Overall, seven relevant studies were identified. Machine-learning applications in stress ECGs resulted in sensitivity and specificity improvements. Some models achieved rates of above 96% in both metrics and reduced false positives by up to 21%. In stress echocardiography, ML models demonstrated an increase in diagnostic precision. Some models achieved specificity and sensitivity rates of up to 92.7 and 84.4%, respectively. Natural language processing applications enabled the categorization of stress echocardiography reports, with accuracy rates nearing 98%. Limitations include a small, retrospective study pool and the exclusion of nuclear stress testing, due to its well-documented status. This review indicates the potential of artificial intelligence applications in refining CAD stress testing assessment. Further development for real-world use is warranted.
Correlation between artificial intelligence-enabled electrocardiogram and echocardiographic features in aortic stenosis
Ito, Saki , Cohen‐Shelly, Michal , Attia, Zachi I. , Lee, Eunjung , Friedman, Paul A. , Noseworthy, Peter A. , López-Jiménez, Francisco , Oh, Jae K. , Noseworthy, Peter A , Lopez-Jimenez, Francisco , Attia, Zachi I , Ito, Saki , Nkomo, Vuyisile T. , Michelena, Héctor I.

Mayo Clinic

European Heart Journal - Digital Health | February 8, 2023 | Volume: 4 | Issue: 3 | Pages: 196-206

10.1093/ehjdh/ztad009 | PMID 37265870 Get It

Abstract Aims An artificial intelligence-enabled electrocardiogram (AI-ECG) is a promising tool to detect patients with aortic stenosis (AS) before developing symptoms. However, functional, structural, or haemodynamic components reflected in AI-ECG responsible for its detection are unknown. Methods and results The AI-ECG model that was developed at Mayo Clinic using a convolutional neural network to identify patients with moderate–severe AS was applied. In patients used as the testing group, the correlation between the AI-ECG probability of AS and echocardiographic parameters was investigated. This study included 102 926 patients (63.0 ± 16.3 years, 52% male), and 28 464 (27.7%) were identified as AS positive by AI-ECG. Older age, atrial fibrillation, hypertension, diabetes, coronary artery disease, and heart failure were more common in the positive AI-ECG group than in the negative group (P &lt; 0.001). The AI-ECG was correlated with aortic valve area (ρ = −0.48, R2 = 0.20), peak velocity (ρ = 0.22, R2 = 0.08), and mean pressure gradient (ρ = 0.35, R2 = 0.08). The AI-ECG also correlated with left ventricular (LV) mass index (ρ = 0.36, R2 = 0.13), E/e′ (ρ = 0.36, R2 = 0.12), and left atrium volume index (ρ = 0.42, R2 = 0.12). Neither LV ejection fraction nor stroke volume index had a significant correlation with the AI-ECG. Age correlated with the AI-ECG (ρ = 0.46, R2 = 0.22) and its correlation with echocardiography parameters was similar to that of the AI-ECG. Conclusion A combination of AS severity, diastolic dysfunction, and LV hypertrophy is reflected in the AI-ECG to detect AS. There seems to be a gradation of the cardiac anatomical/functional features in the model and its identification process of AS is multifactorial.
Artificial intelligence–derived cardiac ageing is associated with cardiac events post-heart transplantation
Ӧzcan, Ilke , Toya, Takumi , Cohen‐Shelly, Michal , Park, Hyun Woong , Ahmad, Ali , Ozcan, Alp , Noseworthy, Peter A. , Lerman, Lilach O. , Kushwaha, Sudhir S. , Friedman, Paul A. , Ozcan, Ilke , Lerman, Amir , Noseworthy, Peter A , Toya, Takumi , Kapa, Suraj , Attia, Zachi I. , Lerman, Amir

Mayo Clinic

European Heart Journal - Digital Health | September 20, 2022 | Volume: 3 | Issue: 4 | Pages: 516-524

10.1093/ehjdh/ztac051 | PMID 36710906 Get It

AbstractAimsAn artificial intelligence algorithm detecting age from 12-lead electrocardiogram (ECG) has been suggested to reflect ‘physiological age’. An increased physiological age has been associated with a higher risk of cardiac mortality in the non-transplant population. We aimed to investigate the utility of this algorithm in patients who underwent heart transplantation (HTx).Methods and resultsA total of 540 patients were studied. The average ECG ages within 1 year before and after HTx were used to represent pre- and post-HTx ECG ages. Major adverse cardiovascular event (MACE) was defined as any coronary revascularization, heart failure hospitalization, re-transplantation, and mortality. Recipient pre-transplant ECG age (mean 63 ± 11 years) correlated significantly with recipient chronological age (mean 49 ± 14 years, R = 0.63, P &lt; 0.0001), while post-transplant ECG age (mean 54 ± 10 years) correlated with both the donor (mean 32 ± 13 years, R = 0.45, P &lt; 0.0001) and the recipient ages (R = 0.38, P &lt; 0.0001). During a median follow-up of 8.8 years, 307 patients experienced MACE. Patients with an increase in ECG age post-transplant showed an increased risk of MACE [hazard ratio (HR): 1.58, 95% confidence interval (CI): (1.24, 2.01), P = 0.0002], even after adjusting for potential confounders [HR: 1.58, 95% CI: (1.19, 2.10), P = 0.002].ConclusionElectrocardiogram age-derived cardiac ageing after transplantation is associated with a higher risk of MACE. This study suggests that physiological age change of the heart might be an important determinant of MACE risk post-HTx.
Real-world performance, long-term efficacy, and absence of bias in the artificial intelligence enhanced electrocardiogram to detect left ventricular systolic dysfunction
Harmon, David , Carter, Rickey E. , Cohen-Shelly, Michal , Svatikova, Anna , Adedinsewo, Demilade , Noseworthy, Peter A. , López-Jiménez, Francisco , Friedman, Paul A. , Attia, Zachi I. , Harmon, David M , Cohen-Shelly, Michal , Adedinsewo, Demilade A , Kapa, Suraj , Lopez-Jimenez, Francisco , Friedman, Paul A , Attia, Zachi I , Noseworthy, Peter A , Carter, Rickey E , Kapa, Suraj

Mayo Clinic

European Heart Journal - Digital Health | May 17, 2022 | Volume: 3 | Issue: 2 | Pages: 238-244

10.1093/ehjdh/ztac028 | PMID 36247412 Get It

Abstract Aims Some artificial intelligence models applied in medical practice require ongoing retraining, introduce unintended racial bias, or have variable performance among different subgroups of patients. We assessed the real-world performance of the artificial intelligence-enhanced electrocardiogram to detect left ventricular systolic dysfunction with respect to multiple patient and electrocardiogram variables to determine the algorithm’s long-term efficacy and potential bias in the absence of retraining. Methods and results Electrocardiograms acquired in 2019 at Mayo Clinic in Minnesota, Arizona, and Florida with an echocardiogram performed within 14 days were analyzed (n = 44 986 unique patients). The area under the curve (AUC) was calculated to evaluate performance of the algorithm among age groups, racial and ethnic groups, patient encounter location, electrocardiogram features, and over time. The artificial intelligence-enhanced electrocardiogram to detect left ventricular systolic dysfunction had an AUC of 0.903 for the total cohort. Time series analysis of the model validated its temporal stability. Areas under the curve were similar for all racial and ethnic groups (0.90–0.92) with minimal performance difference between sexes. Patients with a ‘normal sinus rhythm’ electrocardiogram (n = 37 047) exhibited an AUC of 0.91. All other electrocardiogram features had areas under the curve between 0.79 and 0.91, with the lowest performance occurring in the left bundle branch block group (0.79). Conclusion The artificial intelligence-enhanced electrocardiogram to detect left ventricular systolic dysfunction is stable over time in the absence of retraining and robust with respect to multiple variables including time, patient race, and electrocardiogram features.
Artificial intelligence derived age algorithm after heart transplantation
Cohen‐Shelly, Michal , Ahmad, Ayesha , Lerman, Lilach O. , Friedman, Paul A. , Kushwaha, Sudhir S. , Ӧzcan, Ilke , Toya, Takumi , Corban, Michel , Noseworthy, Peter A. , Kapa, Suraj , Attia, Zachi I. , Lerman, Amir

Mayo Clinic

European Heart Journal | October 20, 2021 | Volume: 42 | Issue: Supplement_1 | Pages: No page available

10.1093/eurheartj/ehab724.2272 Get It

Abstract Background An artificial intelligence (AI) algorithm detecting age from 12-lead ECG has been suggested to signal “physiological age” of the individual. Importantly, increased physiological age gauged by an increased difference between ECG-age and chronological age has been associated with higher risk of cardiac events in non-transplant population. Purpose We sought to investigate the validity of the AI-derived ECG-age algorithm in patients who underwent heart transplantation and its relationship to major adverse cardiovascular events (MACE). Methods A total of 489 consecutive patients who had undergone heart transplantation in our institution between 1994 and 2018 were studied. AI-ECG age was calculated by a previously-trained artificial intelligence (AI) algorithm using a 12-lead ECG per patient. ECGs used in the training process of the algorithm were excluded. The average of the ECG-ages within one year before and one year after heart transplantation was used to represent pre- and post-transplant ECG-ages. MACE was defined as any incidence of revascularization, re-transplantation, and death. Results Pre-transplant ECG-age (mean 63±10 years) correlated significantly with recipient chronological age (mean 50±13 years, r=0.57, p&lt;0.0001), but this correlation between recipient and ECG-ages was weakened after transplantation (mean post-transplant ECG age of 55±10 years, r=0.34, p&lt;0.0001). Interestingly, post-transplant ECG-age correlated significantly with donor age (mean ECG age of 55±10 years vs. mean donor age of 32±13 years, r=0.42, p&lt;0.0001). During a median (IQR) follow-up of 9 (5, 14) years, 251 patients had MACE. Mean change in ECG age after transplantation compared to before was −8.8±12.7 years. Patients who had an increase in ECG-age after compared to before transplantation showed increased risk of MACE (HR: 1.53 [1.16, 2.01], p=0.002), independent of recipient and donor ages (adjusted HR: 1.68 [1.26, 2.25], p=0.001); whereas there were no significant differences in risk of MACE in patients who were transplanted with an older donor heart (HR: 1.07 [0.77, 1.50], p=0.66). In a Kaplan Meier survival analysis, those with increased ECG-age after transplantation had significantly lower MACE-free survival compared to those with decreased ECG-age. (Log-rank P=0.002; Wilcoxon P=0.001) (Figure) Conclusion Post-transplant ECG-age correlates more faithfully with the donor's than the recipient's chronological age, suggesting that ECG-age more closely reflects cardiac age than the patient age. Furthermore, ECG-age derived cardiac aging after transplantation is associated with higher risk of MACE. Funding Acknowledgement Type of funding sources: None.
Machine learning aids clinical decision-making in patients presenting with angina and non-obstructive coronary artery disease
Ahmad, Ali , Shelly-Cohen, Michal, Corban, Michel , Murphree, Dennis H. , Toya, Takumi , Sara, Jaskanwal Deep Singh , Ӧzcan, Ilke , Lerman, Lilach O. , Friedman, Paul A. , Corban, Michel T , Sara, Jaskanwal D, Ozcan, Ilke , Lerman, Amir , Toya, Takumi , Attia, Zachi I. , Lerman, Amir

Mayo Clinic

European Heart Journal - Digital Health | October 18, 2021 | Volume: 2 | Issue: 4 | Pages: 597-605

10.1093/ehjdh/ztab084 | PMID 36713103 Get It

Abstract Aims The current gold standard comprehensive assessment of coronary microvascular dysfunction (CMD) is through a limited-access invasive catheterization lab procedure. We aimed to develop a point-of-care tool to assist clinical guidance in patients presenting with chest pain and/or an abnormal cardiac functional stress test and with non-obstructive coronary artery disease (NOCAD). Methods and results This study included 1893 NOCAD patients (&lt;50% angiographic stenosis) who underwent CMD evaluation as well as an electrocardiogram (ECG) up to 1-year prior. Endothelial-independent CMD was defined by coronary flow reserve (CFR) ≤2.5 in response to intracoronary adenosine. Endothelial-dependent CMD was defined by a maximal percent increase in coronary blood flow (%ΔCBF) ≤50% in response to intracoronary acetylcholine infusion. We trained algorithms to distinguish between the following outcomes: CFR ≤2.5, %ΔCBF ≤50, and the combination of both. Two classes of algorithms were trained, one depending on ECG waveforms as input, and another using tabular clinical data. Mean age was 51 ± 12 years and 66% were females (n = 1257). Area under the curve values ranged from 0.49 to 0.67 for all the outcomes. The best performance in our analysis was for the outcome CFR ≤2.5 with clinical variables. Area under the curve and accuracy were 0.67% and 60%. When decreasing the threshold of positivity, sensitivity and negative predictive value increased to 92% and 90%, respectively, while specificity and positive predictive value decreased to 25% and 29%, respectively. Conclusion An artificial intelligence-enabled algorithm may be able to assist clinical guidance by ruling out CMD in patients presenting with chest pain and/or an abnormal functional stress test. This algorithm needs to be prospectively validated in different cohorts.