Importance Patients undergoing cardiac surgery with cardiopulmonary bypass often require platelet transfusions for bleeding. Platelets are routinely stored at room temperature (20-24 °C) for up to 5 to 7 days; however, cold storage (1-6 °C) may allow for increased storage duration without loss of hemostatic function. Objective To determine the maximum cold-storage duration, up to 21 days, for which cold-stored platelets (CSPs) are noninferior or superior in hemostatic efficacy to room-temperature platelets (RTPs) when transfused in actively bleeding patients undergoing cardiac surgery with cardiopulmonary bypass. Design, Setting, and Participants A phase 3, multicenter, randomized, partially blinded, adaptive, noninferiority, storage duration–ranging trial conducted in pediatric and adult patients undergoing cardiac surgery with planned cardiopulmonary bypass at 27 sites in the US and Australia from December 2021 to March 2025. Statistical analysis was conducted from September 9 to October 3, 2025. Intervention Patients were randomized 2:1 to receive CSPs with a maximum of 21 days of storage vs RTPs with a maximum of 7 days of storage. Main Outcomes and Measures The primary outcome was a hemostatic efficacy score with values ranging from 1 to 5 and higher values indicating greater bleeding. The noninferiority margin was 1 point. The success criterion was met if at least 1 cold-storage duration of 7 days or more had a posterior probability of noninferiority of at least 97.5%. The secondary outcome was 24-hour chest tube output. Results Of the 1000 patients who underwent platelet transfusion, 989 were included in the primary analysis (650 CSPs and 339 RTPs). The cohort had a mean (SD) age of 42.1 (30.1) years and 67.8% were male. CSPs were noninferior to RTPs for the primary outcome, with a probability of greater than 99.9% for all cold-storage durations. Pooled across storage durations, CSPs had a mean difference from RTPs of 0.09 (95% credible interval, −0.06 to 0.23). Median (IQR) chest tube output at 24 hours (8.9 mL/kg [5.2-15.4] for CSPs vs 8.4 mL/kg [5.5-15.9] for RTPs; difference in medians, 0.4 [95% CI, −1.0 to 1.5]) was not statistically different between study groups. In a post hoc analysis, as all storage durations were noninferior, considering the CSPs as a single group, the hemostatic efficacy score was similar between both groups: mean (SD) of 3.08 (1.15) CSPs vs 2.99 (1.10) RTPs. There were no differences in venous or arterial thrombotic events, transfusion-associated adverse events, acute respiratory distress syndrome, kidney failure, septic shock, and mortality between the study groups, except for increased reexploration rates in the CSP group. Conclusions and Relevance For patients undergoing cardiac surgery, CSPs stored up to 21 days are noninferior to RTPs for the control of active surgical bleeding. Use of CSPs may allow for increased availability of platelets by reducing wastage and shortages and may allow for incorporation of platelets into inventory at locations where platelets cannot be maintained due to the 5- to 7-day shelf life of RTPs. Trial Registration ClinicalTrials.gov Identifier: NCT04834414
Hemostatic In Vitro Properties of Novel Plasma Supernatants Produced from Late-storage Low-titer Type O Whole Blood
Background The use of low-titer group O whole blood is increasing. To reduce wastage, unused units can be converted to packed red blood cells. Supernatant is currently discarded post-conversion; however, it could be a valuable transfusable product. The aim of this study was to evaluate supernatant prepared from late-storage low-titer group O whole blood being converted to red blood cells, hypothesizing it will have higher hemostatic activity compared to fresh never-frozen liquid plasma. Methods Low-titer group O whole blood supernatant (n = 12) prepared on storage day 15 was tested on days 15, 21, and 26 and liquid plasma (n = 12) on 3, 15, 21, and 26. Same-day assays included cell counts, rotational thromboelastometry, and thrombin generation. Centrifuged plasma from units was banked for microparticle characterization, conventional coagulation, clot structure, hemoglobin, and additional thrombin generation assays. Results Low-titer group O whole blood supernatant contained more residual platelets and microparticles compared to liquid plasma. At day 15, low-titer group O whole blood supernatant elicited a faster intrinsic clotting time compared to liquid plasma (257 ± 41 vs . 299 ± 36 s, P = 0.044), and increased clot firmness (49 ± 9 vs . 28 ± 5 mm, P < 0.0001). Low-titer group O whole blood supernatant showed more significant thrombin generation compared to liquid plasma (day 15 endogenous thrombin potential 1,071 ± 315 vs . 285 ± 221 nM·min, P < 0.0001). Flow cytometry demonstrated low-titer group O whole blood supernatant contained significantly more phosphatidylserine and CD41 + microparticles. However, thrombin generation in isolated plasma suggested residual platelets in low-titer group O whole blood supernatant were a greater contributor than microparticles. Additionally, low-titer group O whole blood supernatant and liquid plasma showed no difference in clot structure, despite higher CD61 + microparticle presence. Conclusions Plasma supernatant produced from late-storage low-titer group O whole blood shows comparable, if not enhanced, in vitro hemostatic efficacy to liquid plasma. Editor’s Perspective What We Already Know about This Topic What This Article Tells Us That Is New