Background: Patients with cardiac implantable electronic devices (CIEDs) undergoing radiation therapy face potential risks of device malfunction. Proton beam therapy (PBT), with its reduced neutron scatter, has emerged as a potentially safer alternative, yet real-world safety data remain scarce. Methods: We conducted a retrospective cohort study of 100 patients with CIEDs (76 pacemakers, 24 ICDs) who underwent PBT from 2016 to 2023 at a quaternary center. Baseline and serial device interrogations were performed before, during, and after treatment to assess lead impedance, capture thresholds, battery function, and arrhythmic events. Patients were stratified by pacemaker dependence and monitored accordingly. Primary outcomes included device malfunction and new-onset arrhythmias during treatment. Secondary outcomes included device parameter changes, one-year arrhythmia incidence, and cardiac-related hospitalizations. Results: No treatment-related deaths or major device failures occurred. Device malfunction was rare (2 pacemaker patients, 2.6%), with no malfunctions in ICD recipients. Transient, non-clinically significant changes in lead impedance and capture thresholds were observed. Arrhythmias during treatment occurred in 26% of pacemaker and 25% of ICD patients, but only 4% developed new arrhythmias. At one year, device-related complications and cardiac outcomes remained comparable across groups. Independent predictors of arrhythmias during treatment included a higher radiation dose per fraction (OR 1.45; p=0.001), a longer treatment duration (OR 1.12; p=0.04), and a higher number of fractions (OR 1.20; p=0.01). Conclusion: Proton beam therapy appears safe in patients with CIEDs, with a low incidence of clinically significant device malfunctions or arrhythmias. These findings support the integration of PBT into routine practice for this population and underscore the importance of structured monitoring protocols and prospective guideline refinement.
Impact of CIED Field Advisories: Unreimbursed Costs to Medical Systems
AbstractMagnetic resonance imaging (MRI) is a valuable imaging modality for the assessment of both cardiac and non‐cardiac structures. With a growing population of patients with cardiovascular implantable electronic devices (CIEDs), 50%–75% of these patients will need an MRI. MRI‐conditional CIEDs have demonstrated safety of MRI scanning with such devices, yet non‐conditional devices such as hybrid CIEDs which have generator and lead brand mismatch may pose a safety risk. In this retrospective study, we examined the outcomes of patients with hybrid CIEDs undergoing MRI compared to those patients with non‐hybrid CIEDs. A total of 349 patients were included, of which 24 patients (7%) had hybrid CIEDs. The primary endpoint was the safety of MRI for patients with hybrid CIEDs as compared to those with non‐hybrid devices, measured by the rate of adverse events, including death, lead or generator failure needing immediate replacement, loss of capture, new onset arrhythmia, or power‐on reset. Secondary endpoints consisted of pre‐ and post‐MRI changes of decreased P‐wave or R‐wave sensing by ≥50%, changes in pacing lead impedance by ≥50 ohms, increase in pacing thresholds by ≥ 0.5 V at 0.4 ms, and decreasing battery voltage of ≥ 0.04 V. The primary endpoint of any adverse reaction was present in 1 (4.2%) patient with a hybrid device, and consistent of atrial tachyarrhythmia, and in 10 (3.1%) patients with a non‐hybrid device, and consisted of self‐limited atrial and non‐sustained ventricular arrhythmias; this was not statistically significant. No significant differences were found in the secondary endpoints. This study demonstrates that MRI in patients with hybrid CIEDs does not result in increased patient risk or significant device changes when compared to those patients who underwent MRI with non‐hybrid CIEDs.