Citations

Clear

2 citation(s) found for "Sayed, Hisham".

A Pareto‐based beam orientation optimization method for spot scanning intensity‐modulated proton therapy
Sayed, Hisham, Herman, Michael , Beltran, Chris , Beltran, Chris J

Mayo Clinic

Medical Physics | February 20, 2020 | Volume: 47 | Issue: 5 | Pages: 2049-2060

10.1002/mp.14096 | PMID 32077497 Get It

PurposeTo provide a proof of principle of a Pareto‐based method to automatically generate optimal intensity‐modulated proton therapy (IMPT) plans for various noncoplanar beam orientations.MethodsA novel multicriteria beam orientation optimization (MCBOO) method was developed to generate Pareto database of optimal plans. The MCBOO method automatically explores the beam orientations and the scalarization parameters of the IMPT plans simultaneously. The MCBOO method is based on multicriteria bilevel optimization (i.e., hierarchical optimization with two nested levels, named the upper and lower level optimization). In MCBOO, the upper level optimization explores the noncoplanar beam orientation space, while the lower level explores the scalarization parameters for a given beam orientation. Differential evolution method was used in both levels, and the Pareto optimal plans were aggregated from the bilevel optimizations to construct the Pareto database. The MCBOO method was implemented on a multinode multi‐GPU cluster, and it was tested on three brain tumor patient cases. The Pareto database of the three patients was generated for a set of DVH‐based objectives. A statistical analysis was performed between a selected set of MCBOO plans and the manual plan (plan with manually selected beam orientation based on the clinical experience and optimized with the same single plan iterative optimizer used in the MCBOO). The selected set of MCBOO plans consisted of plans that matched the performance of the manual plan [i.e., MCBOO plans that have the same target coverage (within 2%) as the manual plan or better and achieved the same dose (within 2%) or lower to all of the organs at risks (OARs) but one OAR]. Additionally, a dosimetric comparison between of one of the selected MCBOO plans vs the manual plan was conducted.ResultsThe multicriteria beam orientation optimization algorithm automatically generated Pareto plans for the three noncoplanar brain tumor cases. The MCBOO plans provided an alternative objective trade‐offs to the manual plan. The selected MCBOO plans showed a reduction in dose to multiple organs at risk vs the manual plan with a maximum value which ranged between 10.8 and 12.9 Gy for the three patients. The trade‐off of the OAR dose reduction resulted in higher dose to no more than one OAR for each of the selected MCBOO plans vs the manual plan. The maximum dose increase in the MCBOO plans over the manual plan ranged from 7.8 to 11.8 Gy.ConclusionsA novel multicriteria beam orientation optimization method was developed and tested on three IMPT patient cases. The method automatically generates Pareto plans database by exploring the noncoplanar beam orientations. The method was able to identify beam orientations with Pareto optimal plans that are comparable to the manually created plans with varying objective trade‐offs.
Adaptive method for multicriteria optimization of intensity‐modulated proton therapy
Kamal‐Sayed, Hisham, Tseung, H. Wan Chan, Herman, Michael , Beltran, Chris , Beltran, Chris J , Ma, J., Abdel‐Rehim, A.

Mayo Clinic

Medical Physics | October 17, 2018 | Volume: 45 | Issue: 12 | Pages: 5643-5652

10.1002/mp.13239 | PMID 30332515 Get It

PurposeProvide an adaptive multicriteria optimization (MCO) method for intensity‐modulated proton therapy (IMPT) utilizing GPU technology. Previously described limitations of MCO such as Pareto approximation and limitation on the number of objectives were addressed.MethodsThe treatment planning process for IMPT must account for multiple objectives, which requires extensive treatment planning resources. Often a large number of objectives (>10) are required. Hence the need for an MCO algorithm that can handle large number of objectives. The novelty of the MCO method presented here lies on the introduction of the adaptive weighting scheme that can generate a well‐distributed and dense representation of the Pareto surface for a large number of objectives in an efficient manner. In our approach the generated Pareto surface is constructed for a set of DVH objectives. The MCO algorithm is based on the augmented weighted Chebychev metric (AWCM) method with an adaptive weighting scheme. This scheme uses the differential evolution (DE) method to generate a set of well‐distributed Pareto points. The quality of the Pareto points’ distribution in the objective space was assessed quantitatively using the Pareto sampling metric. The MCO algorithm was developed to perform multiple parallel searches to achieve a rapid mapping of the Pareto surface, produce clinically deliverable plans, and was implemented on a GPU cluster. The MCO algorithm was tested on two clinical cases with 10 and 18 objectives. For each case one of the MCO‐generated plans was selected for comparison with the clinically generated plan. The MCO plan was randomly selected out of the set of MCO plans that had target coverage similar to the clinically generated plan and the same or better sparing of the organs at risk (OAR). Additionally, a validation study of the AWCM method vs the weighted sum method was performed.ResultsThe adaptive MCO algorithm generated Pareto points on the Pareto hypersurface in a fast (2–3 hr) and efficient manner for 2 cases with 10 and 18 objectives. The MCO algorithm generated a dense and well‐distributed set of Pareto points on the objective space, and was able to achieve minimization of the Pareto sampling metric. The selected MCO plan showed an improvement of the DVH objectives in comparison to the clinically optimized plan in both cases. For case one, the MCO plan showed a 48% reduction of the 50% dose to OARs and a 16% reduction of the 1% dose to OARs. For case 2, the MCO plan showed a 72% reduction of the 50% dose to OARs and a 42% reduction of the 1% dose to OARs. The comparison of AWCM to WS showed that the AWCM method has a dosimetric advantage over WS for both patient cases.ConclusionWe introduced an adaptive MCO algorithm for IMPT accelerated using GPUs. The algorithm is based on an adaptive method for generating Pareto plans in the objective space. We have shown that the algorithm can provide rapid and efficient mapping of the multicriteria Pareto surface with clinically deliverable plans.