Citations

Clear

3 citation(s) found for "Salazar, Eric".

D-Dimer Reporting and Harmonization: Analysis of College of American Pathologists D-Dimer Proficiency Testing Program
Salazar, Eric, Smock, Kristi J. , Cazzolli, Taryn E, Dlott, Jeffrey S., Lickteig, Nathan, Long, Thomas A., Mulvey, J. Justin , Gil, Morayma Reyes, Rollins-Raval, Marian, Walker, Chance Avery, Zantek, Nicole D. , Goodwin, AJ, Zantek, Nicole D , Gil, Morayma Reyes , Rollins‐Raval, Marian A. , Teruya, Jun , Volod, Oksana , Walker, Chance, Wool, Geoffrey D.

Mayo Clinic

Seminars in Thrombosis and Hemostasis | February 6, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1055/a-2803-3165 | PMID 41651008 Get It

Abstract Measurement of D-dimer, a fibrin degradation product, is crucial for diagnosing thrombotic and fibrinolytic conditions. Despite its expanding utility, D-dimer testing faces challenges due to varying assay methodologies and nonstandardized reporting. To understand D-dimer reporting practices, the College of American Pathologists Hemostasis and Thrombosis Committee analyzed proficiency testing data from D-dimer surveys conducted between 2020 and 2023 across multiple laboratories. The data demonstrate that laboratories commonly report units that differ from the assay package insert when reporting their proficiency testing results. We sought to assess variability in reporting practices and opportunities for improvement in D-dimer reporting amongst participants. To accomplish this, we harmonized all D-dimer results to ng/mL fibrinogen equivalent units from one distributed sample and assessed distinct populations of entries per instrument/reagent combination. Notable trends emerged from this analysis. Data from laboratories using the same instrument/reagent combinations clustered around different means, suggesting issues with unit reporting and/or conversion. Entries reported in mg/L or ug/mL D-dimer units commonly exhibited significant deviations from the dominant population. For one instrument/reagent combination, most reported values differed by approximately twice the certificate of analysis value. This analysis highlights potential issues with D-dimer reporting in proficiency testing. Whether these issues translate into issues with clinical D-dimer reporting requires further study.
Analysis of College of American Pathologists von Willebrand Factor Proficiency Testing Program
Salazar, Eric , Long, Thomas A., Smock, Kristi J. , Harris, Neil Selwyn, Olson, John D. , Ritter, Jacob, Unold, David, VanSandt, Amanda M., Goodwin, Andrew , Wool, Geoffrey D. , Rollins‐Raval, Marian A. , Chen, Dong , Harris, Neil Selwyn, Chan, Clarence W. , Pham, Huy P.

Mayo Clinic

Seminars in Thrombosis and Hemostasis | September 5, 2022 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1055/s-0042-1757132 Get It

AbstractVon Willebrand factor (VWF) level and/or function is altered in von Willebrand disease (VWD), the most common heritable bleeding disorder worldwide. Laboratory assessment of VWF is continually evolving. Historically, the primary method for the assessment of VWF platelet-binding activity was the ristocetin cofactor assay (VWF:RCo). Contemporary alternative measures of VWF platelet-binding activity include VWF:GPIbR (recombinant; using ristocetin), VWF:GPIbM (recombinant; gain-of-function mutant), and monoclonal antibody. Recently, the American Society of Hematology, International Society on Thrombosis and Haemostasis, National Hemophilia Foundation, and World Federation of Hemophilia collaboration issued guidelines recommending the use of newer assays of VWF platelet-binding activity (VWF: GPIbM, VWF: GPIbR) over VWF:RCo, given known limitations of the VWF:RCo assay. Despite this recommendation, the newer VWF:GPIbM and VWF:GPIbR assays are not United States Food and Drug Administration cleared, limiting their availability in the United States. We sought to assess assay utilization trends, agreement of VWF testing methods, and imprecision of VWF testing (based on assigned sample type) from the College of American Pathologists Proficiency Testing Surveys. The analysis confirms that, while VWF antigen testing has low imprecision, the various VWF activity assays have significant interassay variability, with VWF:RCo showing greater imprecision than the newer GPIb-binding assays. The overall trends in assay utilization reflect the barriers to complete compliance with modern VWD diagnostic guidelines in North America.
Analysis of College of American Pathologists von Willebrand Factor Proficiency Testing Program
Salazar, Eric , Long, Thomas A., Smock, Kristi J. , Chen, Dong , Harris, Neil Selwyn, Olson, John D. , Ritter, Jacob, Unold, David, VanSandt, Amanda M., Goodwin, Andrew , Chen, Dong , Wool, Geoffrey D. , Rollins‐Raval, Marian A. , Harris, Neil Selwyn, Chan, Clarence W. , Pham, Huy P.

Mayo Clinic

Seminars in Thrombosis and Hemostasis | September 2, 2022 | Volume: 48 | Issue: 06 | Pages: 690-699

10.1055/s-0042-1749591 | PMID 36055272 Get It

AbstractVon Willebrand factor (VWF) level and/or function is altered in von Willebrand disease (VWD), the most common heritable bleeding disorder worldwide. Laboratory assessment of VWF is continually evolving. Historically, the primary method for the assessment of VWF platelet-binding activity was the ristocetin cofactor assay (VWF:RCo). Contemporary alternative measures of VWF platelet-binding activity include VWF:GPIbR (recombinant; using ristocetin), VWF:GPIbM (recombinant; gain-of-function mutant), and monoclonal antibody. Recently, the American Society of Hematology, International Society on Thrombosis and Haemostasis, National Hemophilia Foundation, and World Federation of Hemophilia collaboration issued guidelines recommending the use of newer assays of VWF platelet-binding activity (VWF: GPIbM, VWF: GPIbR) over VWF:RCo, given known limitations of the VWF:RCo assay. Despite this recommendation, the newer VWF:GPIbM and VWF:GPIbR assays are not United States Food and Drug Administration cleared, limiting their availability in the United States. We sought to assess assay utilization trends, agreement of VWF testing methods, and imprecision of VWF testing (based on assigned sample type) from the College of American Pathologists Proficiency Testing Surveys. The analysis confirms that, while VWF antigen testing has low imprecision, the various VWF activity assays have significant interassay variability, with VWF:RCo showing greater imprecision than the newer GPIb-binding assays. The overall trends in assay utilization reflect the barriers to complete compliance with modern VWD diagnostic guidelines in North America.