Low myocardial extracellular volume is associated with increased QRS voltages and false positives in ECG-based left ventricular hypertrophy classification in elite athletes
Abstract Background Increased QRS voltages in athletes’ ECGs are attributed to electrophysiological cellular adaptations, complicating the detection of left ventricular hypertrophy (LVH). Conversely, higher extracellular volume (ECV), indicative of diffuse fibrosis, reduces QRS voltages – so-called ‘relative voltage deficiency’– and can mask true LVH on ECG. Purpose To investigate sex-specific associations between QRS voltages and myocardial ECV and assess the impact of ECV on false-positive and negative ECG-LVH detection in elite athletes. Methods We conducted a cross-sectional, sex-specific, contrast-enhanced CMR study in healthy, elite athletes with normal ECGs and no complete right bundle branch blocks. Myocardial ECV (%) was measured from pre- and post-contrast T1 mapping. LVH on CMR was defined as an indexed LVM >75 g/m² (men) or >59 g/m² (women). Primary analyses evaluated correlations between ECV, LVM, and summed 12-lead ECG voltages (including voltage/LVM to assess independence), as well as Sokolow-Lyon and Cornell voltages. Secondary multivariable logistic regression examined the association of ECV on false-positive and false-negative ECG-LVH rates using Sokolow-Lyon (≥3.5 mV) and sex-specific Cornell (≥2.8 mV in men; ≥2.3 mV in women) criteria for CMR-LVH. Results In 162 elite athletes (median age 25 years, 44% female, 45% endurance, 96% Caucasian), 23% met Sokolow-Lyon criteria, 6% met Cornell criteria, and 17% had LVH on CMR. The median myocardial ECV was 23% (range 19–31%), which was lower in male compared to female athletes (22% [Q1-Q3: 21–23%] vs 25% [23–26%]; p<0.001). In both sexes, summed 12-lead voltages were inversely correlated with ECV (ρ=–0.36 to –0.37; p=0.001), independent of LVM (voltage/LVM: ρ=–0.33; p=0.004). Only in female athletes did 12-lead voltages correlate with LVM (ρ=0.37; p=0.001). Logistic regression confirmed that lower ECV was associated with an increased likelihood of false-positive Sokolow-Lyon (OR: 0.64 per 1% ECV increment; p=0.011), independent of body mass index (OR: 0.77 per kg/m²; p=0.039) male sex (OR: 2.7; p=0.123) and age (OR: 0.93 per year; p=0.075; AUROC 0.82). Higher ECV conferred greater odds of a false-negative (OR 3.98 per %; p=0.041), though this was limited by small LVH-positive sample size. In Cornell-based models, lower ECV was not statistically significantly associated with increased false-positive rate (OR 0.59; p=0.059). Conclusion In elite athletes, lower ECV ("denser" myocardium) is associated with increased QRS voltages and higher false-positive ECG-LVH rate, particularly for Sokolow-Lyon, while higher ECV may dampen voltages and can mask true LVH on the ECG. Although sex-specific criteria partly mitigate ECV-related effects, these findings demonstrate inherent limitations of voltage-based LVH criteria in athletes. Unexpectedly low QRS voltages in athletes with otherwise high LVM may imply increased ECV, though further research is warranted.Figure:Likelihood of False Pos SL rate Table:Population characteristics
Transcatheter valve implantation for right atrium‐to‐right ventricle conduit obstruction or regurgitation after modified Björk–fontan procedure
Background— Off-label use of transcatheter aortic and pulmonary valve prostheses for tricuspid valve-in-valve implantation (TVIV) within dysfunctional surgical tricuspid valve (TV) bioprostheses has been described in small reports. Methods and Results— An international, multicenter registry was developed to collect data on TVIV cases. Patient-related factors, procedural details and outcomes, and follow-up data were analyzed. Valve-in-ring or heterotopic TV implantation procedures were not included. Data were collected on 156 patients with bioprosthetic TV dysfunction who underwent catheterization with planned TVIV. The median age was 40 years, and 71% of patients were in New York Heart Association class III or IV. Among 152 patients in whom TVIV was attempted with a Melody (n=94) or Sapien (n=58) valve, implantation was successful in 150, with few serious complications. After TVIV, both the TV inflow gradient and tricuspid regurgitation grade improved significantly. During follow-up (median, 13.3 months), 22 patients died, 5 within 30 days; all 22 patients were in New York Heart Association class III or IV, and 9 were hospitalized before TVIV. There were 10 TV reinterventions, and 3 other patients had significant recurrent TV dysfunction. At follow-up, 77% of patients were in New York Heart Association class I or II ( P <0.001 versus before TVIV). Outcomes did not differ according to surgical valve size or TVIV valve type. Conclusions— TVIV with commercially available transcatheter prostheses is technically and clinically successful in patients of various ages across a wide range of valve size. Although preimplantation clinical status was associated with outcome, many patients in New York Heart Association class III or IV at baseline improved. TVIV should be considered a viable option for treatment of failing TV bioprostheses.