B-012 Total Laboratory Automation: Assessing Serum Bicarbonate Stability Under Conditions Experienced Using the Roche Diagnostics Cobas Connection Module
Nicklas, Michael, Baumann, N, Leonard, L M, Block, Darci R , Rossini, L A

Mayo Clinic

Clinical Chemistry | October 2, 2024 | Volume: 70 | Issue: Supplement_1 | Pages: No page available

10.1093/clinchem/hvae106.376 Get It

Abstract Background Bicarbonate stability in serum depends on time, exposure to air, temperature, tube size and sample volume. With implementation of Cobas Connection Module (CCM) automation, the workflow for bicarbonate measurement needed to be re-evaluated. The aim of this study was to determine bicarbonate stability in filled 3.5 mL and 5 mL serum-separator tubes (SSTs) and capped and uncapped aliquot tubes on the CCM automation. Methods Bicarbonate was measured on a Cobas c701 (Roche Diagnostics) at various time points. SSTs (n=8) were centrifuged 6 min at 1649g ∼30 min post-collection. Serum was aliquoted (1 mL) into capped or uncapped tubes and kept ambient (15-25°C) on the CCM track for 0, 60, 90, 150, 180, 240 and 300 minutes (n=2 per time point). Primary SSTs (5mL n=4, and 3.5mL n=5) were uncapped on the CCM track and bicarbonate measured at baseline and 30 minute intervals through 6.5 hours. An absolute difference of +/- 4 mmol/L from baseline was considered acceptable. Results Bicarbonate concentrations decrease with time at rates dependent on whether the aliquot tube is capped or uncapped or the SST is 3.5 mL or 5 mL (Figure 1).Figure 1.Average decrease in bicarbonate concentration with time for capped aliquot tubes (black square), uncapped aliquot tubes (red circle), 3.5 mL serum separator tube (blue up triangle), 5 mL serum separator tube (green down triangle). Bars represent +/- 1SD. Conclusions Bicarbonate in serum is stable for testing for 2.5 hours in uncapped 1 mL aliquot tubes, 3.5 hours in capped 1 mL aliquot tubes, 3.5 hours in uncapped full 3.5 mL SST tubes and 6 hours in uncapped full 5 mL SST tubes at ambient temperatures (15-25°C). Bicarbonate testing can be accommodated by total laboratory automation but processes such as add-ons and retesting must be done with caution.
Selection of Antiobesity Medications Based on Phenotypes Enhances Weight Loss: A Pragmatic Trial in an Obesity Clinic
Acosta, Andrés , Camilleri, Michael , Dayyeh, Barham Abu, Mcrae, Alison, Rossini, William, Burton, Duane D. , Clark, Matthew M. , Abu Dayyeh, Barham, Calderon, Gerardo, Burton, Duane, Acosta, Andres , Calderon-Lopez, Gerardo , González, Daniel , Singh, Sneha

Mayo Clinic

Obesity | March 24, 2021 | Volume: 29 | Issue: 4 | Pages: 662-671

10.1002/oby.23120 | PMID 33759389 Get It

ObjectiveLittle is known about the predictors of response to obesity interventions.MethodsIn 450 participants with obesity, body composition, resting energy expenditure, satiety, satiation, eating behavior, affect, and physical activity were measured by validated studies and questionnaires. These variables were used to classify obesity phenotypes. Subsequently, in a 12‐month, pragmatic, real‐world trial performed in a weight management center, 312 patients were randomly assigned to phenotype‐guided treatment or non‐phenotype‐guided treatment with antiobesity medications: phentermine, phentermine/topiramate, bupropion/naltrexone, lorcaserin, and liraglutide. The primary outcome was weight loss at 12 months.ResultsFour phenotypes of obesity were identified in 383 of 450 participants (85%): hungry brain (abnormal satiation), emotional hunger (hedonic eating), hungry gut (abnormal satiety), and slow burn (decreased metabolic rate). In 15% of participants, no phenotype was identified. Two or more phenotypes were identified in 27% of patients. In the pragmatic clinical trial, the phenotype‐guided approach was associated with 1.75‐fold greater weight loss after 12 months with mean weight loss of 15.9% compared with 9.0% in the non‐phenotype‐guided group (difference −6.9% [95% CI −9.4% to −4.5%], P < 0.001), and the proportion of patients who lost >10% at 12 months was 79% in the phenotype‐guided group compared with 34% with non‐phenotype‐guided treatment group.ConclusionsBiological and behavioral phenotypes elucidate human obesity heterogeneity and can be targeted pharmacologically to enhance weight loss.