Citations

Clear

6 citation(s) found for "Rodrigues, Eduardo".

The Role of Anesthesia in Surgical Oncology: Insights From the Literature and Clinical Considerations
Rodrigues, Eduardo , Barbosa, Maria Thereza , Mendonça, Fabrício Tavares , Pereira, Ana Cristina Pinho Mendes, Moreira, Larissa Govêia , Azevedo, Mauro Pereira de, Rodrigues, Eduardo Soares, Barbosa, Maria Thereza Palmieri, Pinheiro, Rodrigo Nascimento , Almeida, Rosa M. M. de , Govêia, Cátia Sousa , Araujo, Bruno Luís de Castro , Azevedo, Mauro Pereira de, Oliveira, Alexandre Ferreira

Mayo Clinic

Journal of Surgical Oncology | October 8, 2025 | Volume: 132 | Issue: 7 | Pages: 1210-1217

10.1002/jso.70105 | PMID 41059641 Get It

ABSTRACT Anesthetic technique affects surgical outcomes and oncological prognosis. Recognizing the critical role of surgery in cancer treatment, this narrative review aims to improve anesthesiology practices for cancer patients by evaluating actions that positively influence outcomes. Anesthesiologist experience helps guide technique choice in complex cases. Decisions should be customized based on the type of surgery and patient condition, as different techniques can significantly impact results. The expertise of the entire team at specialized centers further enhances outcomes.
Face-to-Face Intubation During a Deep Brain Stimulation Surgery: A Case Report
Rabelo, Sara Peixoto , Rodrigues, Eduardo , Dutcher, Jordan S., Barbosa, Maria Thereza , Rodrigues, Eduardo S, Dutcher, Jordan, Barbosa, Maria Thereza P, Grewal, Sanjeet S. , Dutcher, Jordan S.

Mayo Clinic

A&A Practice | April 3, 2025 | Volume: 19 | Issue: 4 | Pages: e01940

10.1213/xaa.0000000000001940 | PMID 40178123 Get It

We describe the use of a videolaryngoscope in an unconventional manner, with the provider positioned in front of the patient during intubation. This is called a “face-to-face intubation” technique. During a deep brain stimulation surgery, with the head fixed in a Mayfield frame, the placement of the supraglottic airway was unsuccessful on the induction of general anesthesia due to inadequate formation of a seal. Due to these circumstances, we intubated the patient from the front using the face-to-face intubation technique. We believe that the ability to intubate a patient from the front adds to the anesthesiologist’s airway management skills.
Lung Transplantation Using a Hybrid Extracorporeal Membrane Oxygenation Circuit
Thomas, Mathew , Allen, Wesley L. , Makey, Ian A., Rodrigues, Eduardo , Mordecai, Monica, Brown, Thomas E. , Foeks, Jeremy J., Johnson, James L., Landolfo, Kevin, Thomas, Mathew , Martin, Archer K, Rodrigues, Eduardo S, Mordecai, Monica M, Landolfo, Kevin L, Pham, Si M. , Thomas, Mathew , Martin, Archer Kilbourne , Renew, J. Ross , Landolfo, Kevin

Mayo Clinic

ASAIO Journal | March 30, 2020 | Volume: 66 | Issue: 10 | Pages: e123-e125

10.1097/mat.0000000000001157 | PMID 33136605 Get It

Extracorporeal circulation (ECC) support using intraoperative extracorporeal membrane oxygenation (ECMO) during lung transplantation (LTx) is now a routine practice for many high volume centers. Circuits that are dedicated to ECMO alone can be expensive and do not allow full cardiopulmonary bypass (CPB) to be performed. We describe our technique of instituting venoarterial ECMO during LTx using a less-expensive hybrid circuit that facilitates easy and immediate conversion to full CPB if needed, without interruption of ECC.
TEE-guided transatrial inferior vena cava and hepatic veins thrombectomy during double lung transplantation in a VV ECMO-supported patient
Ahmed, Magdy M. El‐Sayed , Rodrigues, Eduardo , Narula, Tathagat , Thomas, Mathew , Thomas, Mathew , El-Sayed Ahmed, Magdy M , Pham, Si M. , Thomas, Mathew , Renew, J. Ross

Mayo Clinic

Journal of Cardiac Surgery | December 7, 2018 | Volume: 33 | Issue: 12 | Pages: 870-871

10.1111/jocs.13957 | PMID 30525232 Get It

Response to “Re: ‘Snare-Ride: A Bailout Technique to Catheterize Target Vessels With Unfriendly Anatomy in Branched Endovascular Aortic Repair’”
Ferreira, Marcelo , Katsargyris, Αthanasios , Rodrigues, Eduardo, Ferreira, Diego, Cunha, Rodrigo, Bicalho, Guilherme , Verhoeven, Eric L.G. , Oderich, Gustavo, Rodrigues, Eduardo, Oderich, Gustavo S.

Mayo Clinic

Journal of Endovascular Therapy | September 19, 2017 | Volume: 24 | Issue: 5 | Pages: 752-752

10.1177/1526602817729278 | PMID 28925335 Get It

“Snare-Ride”: A Bailout Technique to Catheterize Target Vessels With Unfriendly Anatomy in Branched Endovascular Aortic Repair
Ferreira, Marcelo , Katsargyris, Αthanasios , Rodrigues, Eduardo, Ferreira, Diego, Cunha, Rodrigo, Bicalho, Guilherme , Oderich, Gustavo S. , Verhoeven, Eric L.G. , Oderich, Gustavo, Rodrigues, Eduardo, Oderich, Gustavo S.

Mayo Clinic

Journal of Endovascular Therapy | May 18, 2017 | Volume: 24 | Issue: 4 | Pages: 556-558

10.1177/1526602817709465 | PMID 28514896 Get It

Purpose: To describe a novel endovascular bailout technique for successful completion of target vessel stenting during branched stent-graft repair of thoracoabdominal aortic aneurysms (TAAA) after encountering difficulties with standard catheterization techniques. Technique: Technical difficulties when using fenestrated and branched grafts should be expected, especially in difficult anatomy or when an off-the-shelf device (eg, standard 4-branch device) is used that does not perfectly “match” the anatomy. The “snare-ride technique” facilitates antegrade transaxillary side branch catheterization and stent placement during TAAA branched grafting using a snare via a transfemoral approach. The branch of the graft is catheterized from an axillary access. The respective target vessel is then catheterized via a femoral access. An Indy snare is advanced over the transfemoral wire and positioned near the entrance of the target vessel. The transaxillary wire inside the branch of the graft is then advanced, snared, and pushed inside the target vessel with the snare. The procedure is thereafter continued with antegrade bridging of the target vessel in routine fashion. Conclusion: The snare-ride technique can be a useful maneuver to catheterize target vessels with difficult anatomy in TAAA branched stent-graft repair. Early experience shows safety and feasibility.