Citations

Clear

7 citation(s) found for "Ritter, Matthew".

Safety of selective operating room extubation after median sternotomy for cardiac surgery with parasternal regional analgesia
Christensen, Jon M. , Ripoll, Juan G, Vinzant, Nathan J, Smith, Mark, Mauermann, William J, Dearani, Joseph A, Lemahieu, Allison M, Schroeder, Darrell R, Ritter, Matthew, Christensen, Jon , Ripoll, Juan G, Vinzant, Nathan J, Smith, Mark, Mauermann, William J, Dearani, Joseph A, Lemahieu, Allison M, Schroeder, Darrell R, Ritter, Matthew

Mayo Clinic

Regional Anesthesia & Pain Medicine | December 19, 2025 | Volume: No volume available | Issue: No issue available | Pages: rapm-2025-107157

10.1136/rapm-2025-107157 | PMID 41419242 Get It

Introduction The safety of operating room extubation (ORE) immediately following cardiac surgery via median sternotomy remains unclear. However, reported outcomes in the setting of parasternal regional analgesia are limited. This study examined the safety of ORE for patients who received postoperative superficial parasternal intercostal plane (SPIP) blocks following median sternotomy for cardiac surgery. Methods Single-center retrospective cohort study from January 2020 to September 2023 compared the outcomes of adult cardiac surgical patients who were either extubated in the operating room immediately after surgery with SPIP blocks (ORE-B), received SPIP blocks and were extubated in the intensive care unit within 6 hours (FTE-B) or did not receive SPIP blocks and were extubated in the intensive care unit within 6 hours (FTE). Assessed outcomes were reintubation, use of non-invasive positive pressure ventilation (NIPPV), intensive care unit (ICU) readmission, return to OR, postoperative transfusion, ICU and hospital length of stay. Results 2294 patients were studied, which included 256 ORE-B patients, 729 FTE-B patients and 1,309 FTE patients. Differences in reintubation rates (1.2% vs 0.7% vs 1.2%, all p≥0.26) and use of NIPPV (4.8% vs 4.8% vs 5.1%, all p≥0.743) did not differ between ORE-B, FTE-B, and FTE groups, respectively. Time to extubation differed between FTE-B and FTE groups (2.5 hours vs 3.8 hours, p=<0.001), respectively. Additionally, hospital length of stay was significantly shorter for groups ORE-B and FTE-B compared with group FTE (5 days vs 5 days vs 6 days), respectively. Conclusions Selective ORE after median sternotomy for cardiac surgery was not associated with an increased risk of reintubation and NIPPV use in the setting of parasternal regional analgesia.
Response to ‘Single versus two-level superficial parasternal intercostal plane block: cadaveric evaluation of injectate spread with needle tip position on anterior surface of costal cartilage’
Christensen, Jon M. , Douglas, Rachel , Kattil, Punnose , Lachman, Nirusha , Mauermann, William J., Christensen, Jon , Ritter, Matthew, Kattil, Punnose K , Ritter, Matthew, Douglas, Rachel

Mayo Clinic

Regional Anesthesia & Pain Medicine | September 26, 2025 | Volume: No volume available | Issue: No issue available | Pages: rapm-2025-106922

10.1136/rapm-2025-106922 | PMID 41005805 Get It

Single versus two-level superficial parasternal intercostal plane block: cadaveric evaluation of injectate spread with needle tip position on anterior surface of costal cartilage
Christensen, Jon M. , Douglas, Rachel , Kattil, Punnose , Lachman, Nirusha , Mauermann, William J., Christensen, Jon , Ritter, Matthew, Kattil, Punnose K , Ritter, Matthew, Douglas, Rachel

Mayo Clinic

Regional Anesthesia & Pain Medicine | April 7, 2025 | Volume: No volume available | Issue: No issue available | Pages: rapm-2025-106488

10.1136/rapm-2025-106488 | PMID 40194831 Get It

Introduction Superficial parasternal intercostal plane blocks have grown in clinical use for cardiac surgery as a targeted fascial plane block for median sternotomy. Despite this, there remains no consensus on technique for optimal parasternal spread of injectate. The primary objective of this cadaveric study was to evaluate parasternal spread of injectate of single versus two-level superficial parasternal intercostal plane injections with the needle tip positioned on the anterior surface of the costal cartilage. Methods We performed 10 single-level injections at T4 and 10 two-level injections at T3 and T5 on alternating sides in 10 fresh frozen cadavers. All injections were ultrasound guided with a parasagittal ultrasound probe orientation and an in-plane needle orientation. Anatomic dissections were performed immediately following injections. Results Parasternal spread of injectate was greater with two-level injections at T3 and T5 costal cartilages than with single-level injections at the T4 costal cartilage, with two-level injections consistently spreading to the T2–T5 intercostal spaces. Median (Q1, Q3) intercostal space spread for single-level injections was 2.0 (2.0–2.5). Median (Q1, Q3) intercostal space spread for two-level injections was 4.0 (4.0–4.375). Conclusions Two-level injections with the needle tip located on the anterior surface of the costal cartilage resulted in improved parasternal spread compared with single-level injections.
New Q Waves and T-Wave Inversions Following Endovascular Surgery Lead to Diagnosis of Clinically Silent Myocardial Infarction Despite Negative Preoperative Cardiovascular Risk Evaluation: A Case Report
Delaney, Daniel J. , Warner, Paul A., Ritter, Matthew J., Delaney, Daniel J., Ritter, Matthew J.

Mayo Clinic

A&A Practice | January 5, 2020 | Volume: 14 | Issue: 4 | Pages: 112-115

10.1213/xaa.0000000000001160 | PMID 31904627 Get It

In this case, a 79-year-old male presented with new anteroseptal Q waves and T-wave inversions across the precordial leads following an otherwise uneventful endovascular repair of his thoracoabdominal aortic aneurysm. The patient had no history of cardiac disease and had undergone a dobutamine stress echocardiogram within the preceding 6 months that showed no evidence of inducible ischemia. Nevertheless, routine postoperative electrocardiogram (EKG) revealed new Q waves and T-wave inversions and transthoracic echocardiogram that demonstrated akinesis of the left ventricle (LV) apex with chronic-appearing apical thrombus. We will further discuss preoperative evaluation of cardiovascular risk along with postoperative interpretation of EKG abnormalities.
Undiagnosed Systemic Mastocytosis Presenting as Postoperative Distributive Shock: A Case Report
Ripoll, Juan G. , Ritter, Matthew J. , Comfere, Thomas B., Gilkey, George D., Smith, Mark M. , Schaff, Hartzell V. , Warner, Matthew A.

Mayo Clinic

A&A Practice | September 22, 2019 | Volume: 13 | Issue: 10 | Pages: 392-395

10.1213/xaa.0000000000001093 | PMID 31567270 Get It

Systemic mastocytosis (SM) is a rare clinical condition resulting from a clonal proliferation of abnormal mast cells. The clinical presentation may vary from mild cutaneous manifestations to aggressive systemic symptoms including intermittent episodes of anaphylaxis. We present a case of a 69-year-old male with abrupt and recurrent episodes of anaphylaxis with refractory distributive shock following cardiac surgery with cardiopulmonary bypass. Following a complex postoperative course, a bone marrow biopsy ultimately confirmed the diagnosis. Although rare, SM should be considered in the differential diagnosis of postoperative patients with unexplained and recurrent episodes of distributive shock.
Fiberoptic-Guided Use of an Airway Exchange Catheter During Exchange of a Kinked King LTS-D Laryngeal Tube for an Endotracheal Tube: A Case Report
Kelm, Diana J. , Diedrich, Daniel A. , Ritter, Matthew J., Gajic, Ognjen, Zhu, Xun , Zhu, Xun, Ritter, Matthew J. , Gajic, Ognjen

Mayo Clinic

A&A Practice | July 11, 2018 | Volume: 11 | Issue: 4 | Pages: 100-102

10.1213/xaa.0000000000000753 | PMID 29634529 Get It

The use of supraglottic airway devices such as the King LTS-D laryngeal tube has increased in the prehospital setting because of their relative ease of successful insertion, even in the hands of inexperienced providers. However, these devices have their own associated complications. In patients with a known or suspected difficult airway, supraglottic airway device exchanges should occur under controlled conditions using an airway exchange catheter, preferably under direct visualization with a flexible fiberoptic bronchoscope. We report unanticipated difficulties with supraglottic airway exchange caused by a kinked King LTS-D laryngeal tube.
Serial infusions of low-dose ketamine for major depression
Rasmussen, Keith G., Lineberry, Timothy W., Galardy, Christine W., Kung, Simon , Palmer, Brian A. , Ritter, Matthew J. , Schak, Kathryn M. , Sola, Christopher L., Hanson, Allison J, Frye, Mark A. , Lapid, Maria I.

Mayo Clinic

Journal of Psychopharmacology | February 21, 2013 | Volume: 27 | Issue: 5 | Pages: 444-450

10.1177/0269881113478283 | PMID 23428794 Get It

Background: Single infusions of ketamine have been used successfully to achieve improvement in depressed patients. Side effects during the infusions have been common. It is not known whether serial infusions or lower infusion rates result in greater efficacy. Methods: Ten depressed patients were treated with twice weekly ketamine infusions of ketamine 0.5 mg/kg administered over 100 min until either remission was achieved or four infusions were given. Side effects were assessed with the Young Mania Rating Scale (YMRS) and the Brief Psychiatric Rating Scale (BPRS). Patients were followed naturalistically at weekly intervals for four weeks after completion of the infusions. Results: Five of 10 patients achieved remission status. There were no significant increases on the BPRS or YMRS. Two of the remitting patients sustained their improvement throughout the four week follow-up period. Conclusions: Ketamine infusions at a lower rate than previously reported have demonstrated similar efficacy and excellent tolerability and may be more practically available for routine clinical care. Serial ketamine infusions appear to be more effective than a single infusion. Further research to test relapse prevention strategies with continuation ketamine infusions is indicated.