Quantifying performance of high-density mapping catheters in in-vivo and benchtop models
Kapa, S, Siddiqui, U, Maddox, W, Friedman, D, Wenzel, G, Mekala, P, Mitkar, A, Deno, D C, Rippke, J, Barbhaiya, C, Siddiqui, Usman, Maddox, William R. , Wenzel, G, Deno, Don Curtis, Barbhaiya, Chirag R.

Mayo Clinic

Europace | June 25, 2026 | Volume: 28 | Issue: Supplement_1 | Pages: No page available

10.1093/europace/euag105.009 Get It

Abstract Background/Introduction High-density mapping catheters enhance the speed and accuracy of 3-dimensional data collection. However, differences in data acquisition, efficiency, and system processing are not well quantified, even for catheters with similar form factors. Purpose Compare in-vivo and bench performance of the HD Grid X (EnSite X v 5.0.1) and Optrell (Carto v 8.1.1) catheters. Criteria include mapping and modeling efficiency, electrogram (EGM) amplitude dependence on orientation, and resolution of low voltage boundaries. Methods In-vivo: In 6 swine, 5 physicians used each catheter in a randomized order to create models of equivalent detail of the left atrium (LA) and ventricle (LV) during atrial pacing. Comparable mapping parameters were selected between the respective mapping systems. Each mapping catheter was then placed in a stable location at 3 different anatomical sites in the LA and rotated while collecting manual map points. In the right atrium (RA), an independent operator placed groups of 5-6 radiofrequency (RF) lesions with a focal ablation catheter. Each physician, being blinded to the ablated areas, remapped the RA and identified the area(s) they assessed as being ablated. The indicated regions were measured on the mapping system and compared to the actual ablated area(s) observed during necropsy. Bench: Using a wavefront emulator platform, 2 propagation patterns were created—case 1: a single uniform wavefront propagating across the platform, and case 2: two uniform wavefronts colliding in the center of the platform creating a low-voltage region. For both cases, during map collection, the catheter was oriented at 3 different angles (0, 45, and 90 deg.) relative to the propagation direction. For case 1, the EGM amplitudes were compared. For case 2, the spatial resolution of the low-voltage region was defined by the full-width at half max (FWHM), i.e., the measured width of the area containing less than half the max amplitude. Results In-Vivo: Median rate of mapping point acquisition for Grid X was higher than Optrell by 167% (p=0.02; 48,18 points/s) in the LA and 39% (p=0.03; 18,13 points/s) in the LV. Median time for model completion for Grid X was shorter than Optrell by 39% (p=0.047; 318s, 525s) in the LA and 45% (p=0.02; 342s, 620s) in the LV. Grid X measured higher amplitude EGMs in all 3 LA locations (Fig 1). The mean error in the lesion areas identified by Grid X was 25% lower than Optrell (p=0.04; 154, 204 mm²). Bench: In case 1, Grid X recorded a median normalized amplitude which was 58% larger than Optrell (Fig 1). In case 2, Grid X recorded a median voltage resolution which was 34% finer than Optrell (Fig 2). Conclusion Design considerations beyond catheter shape may impact mapping quality and speed. Grid X collects mapping and geometry data faster, is less reliant on catheter orientation to collect high voltage EGMs, and more accurately defines low voltage boundaries compared to Optrell.Figure 1:EGM Amplitude DataFigure 2:Voltage Resolution
A phase IB study of the combination of selumetinib (AZD6244; ARRY-142886) and cyclosporin A (CsA) in patients with advanced solid tumors with an expansion cohort in metastatic colorectal cancer (mCRC).
Krishnamurthy, Anuradha , Stein, Mark N. , Sanoff, Hanna K. , Lee, James J. , Hansen, Aaron R. , Malhotra, Usha , Rippke, Sarah, Davis, S. Lindsey , Messersmith, Wells A. , Eckhardt, S. Gail, Dasari, Arvind , Lockhart, A. Craig , Bekaii‐Saab, Tanios , Yao, James C. , Meric‐Bernstam, Funda , Lieu, Christopher H. , Sanoff, Hanna , Hansen, Aaron R

Mayo Clinic

Journal of Clinical Oncology | March 21, 2017 | Volume: 35 | Issue: 4_suppl | Pages: 609-609

10.1200/jco.2017.35.4_suppl.609 Get It

609 Background: Targeting MEK is of interest in the development of novel agents for treatment of many malignancies. However, better strategies are needed to overcome acquired resistance to MEK inhibitors. Preclinical studies have shown Wnt pathway overexpression in KRAS mutant cell lines resistant to the MEK inhibitor, Selumetinib. The combination of selumetinib and cyclosporin A (CsA), a non-canonical WnT pathway modulator, demonstrated antitumor activity in patient-derived xenograft (PDX) models. We are conducting an NCI CTEP-approved Phase I/IB trial (NCI # 9571/COMIRB # 13-2628) of selumetinib and CsA combination. Biomarkers of response to therapy are being co-developed. We hypothesize that this combination will be safe and potentially effective in patients with mCRC and that upregulation of FZD2 may predict for sensitivity. Methods: Phase I trial with initial dose escalation investigating the combination of selumetinib and CsA in patients with advanced solid tumors (n = 18) followed by an expansion cohort in patients with irinotecan and oxaliplatin-refractory mCRC (n = 20). The expansion cohort utilizes a selumetinib “run-in” to evaluate efficacy in RAS-WT and RAS-MT mCRC to identify those patients most likely to respond to the combination. Results: 18 patients were enrolled in the dose escalation phase and 10 patients have been enrolled in the dose expansion phase as of September 2016. Grade 1 or 2 nausea and rash were reported as the most common AEs. Most commonly reported Grade 3 or 4 toxicities were hypertension, elevated liver enzymes and rash. Three DLTs were reported with Grade 3 hypertension noted at dose level 1 and 2 and grade 3 rash reported at dose level 2. The maximum tolerated dose was defined as Selumetinib 75 mg BID and CsA 2 mg/kg BID on a 28-day cycle. Two partial responses and sixteen stable disease responses have been observed. Six patients have exhibited progressive disease. Conclusions: Selumetinib in combination with cyclosporin A appears to be well-tolerated with evidence of activity in solid tumors. Expansion cohort will complete enrollment this month. Clinical trial information: NCT02188264.