Citations

Clear

3 citation(s) found for "Riley, William".

Venoarterial extracorporeal membrane oxygenation in adults with cardiogenic shock
Wieruszewski, Patrick M., French, Amy, Crowley, J, Michel, Eriberto, Riley, William, Convissar, David, Ortoleva, Jamel P. , Wieruszewski, Patrick M. , French, Amy L., Crowley, Jerome , Michel, Eriberto , Pisano, Dominic V.

Mayo Clinic

Frontiers in Cardiovascular Medicine | June 25, 2026 | Volume: 13 | Issue: No issue available | Pages: No page available

10.3389/fcvm.2026.1851908 | PMID 42428484 Get It

Cardiogenic shock in adults continues to carry a high mortality despite advances in cardiac care, interventions and critical care. A major advancement in cardiogenic shock care came with the advent of temporary mechanical circulatory support including the intra-aortic balloon pump, ventricular assist devices, and venoarterial extracorporeal membrane oxygenation (VA ECMO). VA ECMO is a type of temporary mechanical circulatory support used in selected patients with cardiogenic shock that have failed to be adequately supported by less invasive approaches including vasoactive medications, volume optimization, and other temporary mechanical circulatory support. VA ECMO is resource intensive support strategy that requires expertise and cooperation from multiple specialties. Complications during VA ECMO support are common and include bleeding, acute kidney injury, stroke, mechanical complications during cannulation, hemolysis, and limb ischemia. VA ECMO circuits drain blood from the venous system, oxygenate and remove carbon dioxide, and return it to the arterial system, providing biventricular support. VA ECMO may be deployed peripherally (through femoral or internal jugular veins and returning blood to axillary or femoral arteries), or centrally from the right atrium to the aorta. Vascular access used for peripheral VA ECMO is large and includes arterial cannulas (usually 15 to 19 French), venous cannulas (usually 21 to 25 French), and a distal perfusion catheter (5 to 8 French). VA ECMO causes significant physiologic changes including reduced pulmonary blood flow, an inflammatory response, increases in left ventricular afterload, dual circulation when initiated through most peripheral sites, and coagulopathy. Management considerations for patients supported by VA ECMO are complex for multiple reasons including the differing approaches to the underlying cause of cardiogenic shock (for example, ischemic vs. non ischemic etiologies), patient comorbidities, whether the goal is recovery, heart transplant, or dischargeable ventricular assist device. Weaning from VA ECMO is a complex process with multiple possible approaches, and decannulation is most commonly accomplished through surgical or percutaneous approaches. There is a paucity of literature on VA ECMO and most guidance is based on retrospective data and expert opinion. What follows is an overview of VA ECMO for cardiogenic shock.
Mood Benefits Of A Single Bout Of Exercise In Pregnancies Complicated By Fetal Growth Restriction
Szymanski, Linda M. , Paudel, Alissa M., Purvis, Rebecca , Riley, William L. , Fortner, Kimberly B. , Carter, Kristina, Zite, Nikki B., Tinius, Rachel A. , Maples, Jill M.

Mayo Clinic

Medicine & Science in Sports & Exercise | September 16, 2024 | Volume: 56 | Issue: 10S | Pages: 724-724

10.1249/01.mss.0001058776.35336.85 Get It

Ultrathin and Robust Hydrogel Coatings on Cardiovascular Medical Devices to Mitigate Thromboembolic and Infectious Complications
Parada, German Alberto , Yu, Yan , Riley, William B., Lojovich, Sarah, Tshikudi, Diane M. , Ling, Qing , Zhang, Yefang, Ling, Lei , Yang, Yueying , Nadkarni, Seemantini K. , Nabzdyk, Christoph S. , Nabzdyk, Christoph , Wang, Jiaxin , Zhao, Xuanhe

Mayo Clinic

Advanced Healthcare Materials | September 17, 2020 | Volume: 9 | Issue: 20 | Pages: No page available

10.1002/adhm.202001116 | PMID 32940970 Get It

AbstractThromboembolic and infectious complications stemming from the use of cardiovascular medical devices are still common and result in significant morbidity and mortality. There is no strategy to date that effectively addresses both challenges at the same time. Various surface modification strategies (e.g., silver, heparin, and liquid‐impregnated surfaces) are proposed yet each has several limitations and shortcomings. Here, it is shown that the incorporation of an ultrathin and mechanically robust hydrogel layer reduces bacterial adhesion to medical‐grade tubing by 95%. It is additionally demonstrated, through a combination of in vitro and in vivo tests, that the hydrogel layer significantly reduces the formation and adhesion of blood clots to the tubing without affecting the blood's intrinsic clotting ability. The adhesion of clots to the tubing walls is reduced by over 90% (in vitro model), which results in an ≈60% increase in the device occlusion time (time before closure due to clot formation) in an in vivo porcine model. The advantageous properties of this passive coating make it a promising surface material candidate for medical devices interfacing with blood.