Citations

Clear

28 citation(s) found for "Rex, Douglas".

Serrated Polyposis Syndrome: A Review and Consensus Statement by the US Multi-Society Task Force on Colorectal Cancer
Rex, Douglas K., Anderson, Joseph C., Burke, Carol A., Jacobson, Brian C , May, Folasade P. , Patel, Swati , Samadder, N. Jewel, Stoffel, Elena M. , Robertson, Douglas J.

Mayo Clinic

American Journal of Gastroenterology | September 30, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.14309/ajg.0000000000004081 | PMID 42814894 Get It

Serrated polyposis syndrome (SPS) is the most common polyposis syndrome, yet SPS often goes unrecognized. SPS diagnosis is based on clinical criteria established by the World Health Organization and includes the size, cumulative lifetime number, and location of serrated polyps throughout the colon. Individuals with SPS have an increased risk of prevalent and incident colorectal cancer (CRC). Meticulous inspection, clearing of the colon and frequent surveillance colonoscopy is recommended to decrease incident CRC. Colorectal surgery is indicated for individuals diagnosed with cancer or whose polyp burden cannot be managed endoscopically by expert endoscopists. There is no common germline pathogenic variant associated with SPS. Germline genetic testing is indicated only in individuals who meet criteria for a known hereditary syndrome in the appropriate clinical setting. First-degree relatives of patients with SPS are at heightened risk of CRC and should undergo colonoscopic screening.
Artificial Intelligence-Assisted Colonoscopy With or Without Mucosal Exposure Device for Detection of Colorectal Adenomas: A Meta-Analysis
Beran, Azizullah , Ramai, Daryl, Albakri, Almaza A., Spadaccini, Marco , Hassan, Cesare , Guardiola, John , Rex, Douglas K., Spadaccini, Marco , Hassan, Cesare , Guardiola, John J , Nayfeh, Tarek , Saleem, Nasir , Repici, Alessandro

Mayo Clinic

Endoscopy International Open | August 4, 2025 | Volume: 13 | Issue: CP | Pages: No page available

10.1055/a-2676-4144 | PMID 40932819 Get It

Abstract Artificial intelligence (AI) and mucosal exposure devices like Endocuff have independently improved the adenoma detection rate (ADR) during colonoscopy. This meta-analysis evaluated the combined effect of Endocuff and AI versus AI alone on colorectal neoplasia detection rates. We searched PubMed, Embase, and Web of Science for randomized controlled trials (RCTs) comparing the impact of Endocuff+AI versus AI alone on colorectal neoplasia detection. Primary outcome was ADR; secondary outcomes included advanced adenoma detection rate (AADR), sessile serrated lesion detection rate (SSLDR), cecal intubation time, and withdrawal time. Pooled risk ratios (RRs) and mean differences (MDs) with 95% confidence intervals (CIs) were calculated using a random-effects model. Three RCTs with 2404 subjects were included (n = 1198 Endocuff+AI vs. n = 1206 AI alone). ADR was significantly higher in the Endocuff+AI group than in the AI alone group (54% vs. 48%, respectively) (RR 1.12, 95% CI 1.03–1.21, P = 0.01, I2 = 0%). There was a trend toward higher AADR (12.3% vs. 10%, RR 1.23, 95% CI 0.96–1.59, P = 0.10, I2 = 17%) and SSLDR (17.6% vs. 15.5%, RR 1.16, 95% CI 0.96–1.40, P = 0.13, I2 = 0%) in the Endocuff+AI group compared with the AI alone group, but it did not reach statistical significance. Both cecal intubation time (MD -0.61 minutes; 95% CI -1.54–0.33; P = 0.20; I2 = 87%) and withdrawal time (MD -0.42 minutes; 95% CI -1.01–0.17; P = 0.17, I2 = 60%) were similar between the two groups. Endocuff combined with AI was superior to AI alone in improving the adenoma detection rate without increasing intubation or withdrawal times.
Adverse events of cold snare compared with hot snare and ablation endoscopic mucosal resection for large colorectal polyps
Medawar, Edgard , Pohl, Heiko , Rex, Douglas K. , Levenick, John M. , Pleskow, Douglas K. , Khashab, Mouen A. , Moyer, Matthew T. , Melson, Joshua , Wallace, Michael B. , Mosko, Jeffrey D. , Singh, Ajaypal , Gavrić, Aleksandar , Gordon, Stuart R. , Ngamruengphong, Saowanee , Taunk, Pushpak, Barber, Jeremy, Piraka, Cyrus , Elmunzer, B. Joseph , Aslanian, Harry R., Elatrache, Mazen, Zolotarevsky, Eugene, Rastogi, Amit , Renteln, Daniel von , Consortium, Additional members of the Large Polyp Study, Wallace, Michael B , Shahidi, Neal , Djinbachian, Roupen , von Renteln, Daniel , Pleskow, Douglas , Yang, Dennis J. , Djinbachian, Roupen , Consortium, Additional members of the Large Polyp Study

Mayo Clinic

Endoscopy | July 24, 2025 | Volume: 58 | Issue: 02 | Pages: 163-173

10.1055/a-2665-0521 | PMID 40719106 Get It

Abstract Endoscopic mucosal resection (EMR) techniques for large (≥20 mm) nonpedunculated colorectal polyps (LNPCPs) have expanded with the introduction of ablation and cold EMR. This study assessed adverse events (AEs) for the newer EMR techniques, including cold EMR, compared with hot EMR. We conducted a secondary analysis of four prospective multicenter studies of consecutive patients with LNPCPs undergoing EMR from 2019 to 2024. The primary outcome was serious AEs (SAEs) with cold and hot EMR. Secondary outcomes included SAEs in the hot EMR subgroups (no ablation [hEMR], margin ablation [hEMR-m], margin and base ablation [hEMR-mb]). 1762 patients (mean age 65.8; 1890 LNPCPs) were included: 522 cold and 1368 hot EMRs (368 hEMR, 770 hEMR-m, 230 hEMR-mb). SAEs were higher with hot EMR (4.7%, 95%CI 3.6%–5.9%) vs. cold EMR (1.9%, 95%CI 0.9%–3.5%), also for the subgroups of hEMR (6.0%, 95%CI 3.8%–8.9%), hEMR-m (3.9%, 95%CI 2.6%–5.5%), and hEMR-mb (5.2%, 95%CI 2.7%–8.9%). Serious postendoscopic bleeding (PEB) was numerically higher with hot EMR (2.3%, 95%CI 1.6%–3.3%) vs. cold EMR (1.3%, 95%CI 0.5%–2.7%), also for the subgroups of hEMR (3.0%, 95%CI 1.5%–5.3%), hEMR-m (1.9%, 95%CI 1.1%–3.2%), and hEMR-mb (2.6%, 95%CI 1.0%–5.6%). Perforation, intraprocedural and post-procedural, was numerically higher with hot EMR (1.2%, 95%CI 0.7%–2.0%) vs. cold EMR (0.2%, 95%CI 0.0%–1.1%). hEMR-m and hEMR-mb with clipping had lower rates of serious and overall PEB than no clipping. Cold EMR demonstrated lower rates of SAEs, serious PEB, and perforation compared with hot EMR. Perforation and mortality occurred almost exclusively after hot EMR. Hot EMR with margin +/− base ablation did not increase SAEs compared with hot EMR without ablation.
Cold snare endoscopic resection for large colon polyps: a randomised trial
Pohl, Heiko , Rex, Douglas K. , Barber, Jeremy, Moyer, Matthew T. , Elmunzer, B. Joseph , Rastogi, Amit , Gordon, Stuart R. , Zolotarevsky, Eugene, Levenick, John M. , Aslanian, Harry R., Elatrache, Mazen, Renteln, Daniel von , Brahmbhatt, Bhaumik , Keswani, Rajesh N. , Kumta, Nikhil A. , Smith, Zachary L. , Ghanimeh, Mouhanna K. Abu, Simmer, Stephen, MacKenzie, Todd A. , Piraka, Cyrus , von Renteln, Daniel , Smith, Zachary L , Piraka, Cyrus , Wallace, Michael B. , Pleskow, Douglas K. , Sanaei, Omid

Mayo Clinic

Gut | May 20, 2025 | Volume: 74 | Issue: 11 | Pages: 1804-1813

10.1136/gutjnl-2025-335075 | PMID 40393701 Get It

Background Complications of endoscopic mucosal resection (EMR) of large colorectal polyps remain a concern. Objective We aimed to compare safety and efficacy of cold EMR (without electrocautery) to hot EMR (with electrocautery) of large colorectal polyps. Design In this multicentre randomised trial, patients with any large (≥20 mm) non-pedunculated colon polyp were assigned to cold or hot EMR (primary intervention), and to submucosal injection with a viscous or non-viscous solution (secondary intervention) following a 2×2 design. The primary outcome was the rate of severe adverse events (SAEs). The secondary outcome was polyp recurrence. In this study, we report results of the primary intervention. Results 660 patients were randomised and analysed. An SAE was observed in 2.1% of patients in the cold EMR group and in 4.3% in the hot EMR group (p=0.10) (per protocol analysis 1.4 vs 5.0%, p=0.017) with fewer perforations following cold EMR (0%) compared with hot EMR (1.6%, p=0.028). Postprocedure bleeding did not differ (1.5% vs 2.2%, p=0.57). The effect of cold resection was independent of the type of submucosal injection solution, polyp size or antithrombotic medications. Recurrence was detected in 27.6% and 13.6% in the cold and hot EMR groups, respectively (p<0.001). Recurrence was not significantly different for 20–29 mm polyps (18.6% vs 13.4%, p=0.24) and for sessile serrated polyps (14.1% vs 8.5%, p=0.33). Conclusion Universal application of cold EMR did not significantly lower SAEs (unless cold EMR could be completed) and doubled the recurrence rate compared with hot EMR. Trial registration details ClinicalTrials.gov, number: NCT03865537 .
Risk of Post-Polypectomy Bleeding After Colorectal Endoscopic Mucosal Resection in Patients with Chronic Kidney Disease: A Propensity-Matched Analysis of the US Collaborative Network
Patel, Feenalie N. , Ramai, Daryl , Sr, Khaled, Shaik, Danial H., Thakkar, Shyam , Rex, Douglas K. , Beran, Azizullah , Elfert, Khaled , Mohamed, Mouhand , Canakis, Andrew , Sr, Khaled, Bhavsar‐Burke, Indira , Guardiola, John J.

Mayo Clinic

No container title available | April 25, 2025 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.21203/rs.3.rs-6398416/v1 Get It

Abstract Background Studies evaluating the risk of post-polypectomy bleeding (PPB) after colorectal endoscopic mucosal resection (EMR) in patients with chronic kidney disease (CKD) and end-stage renal disease (ESRD) are limited. Methods This retrospective cohort study utilized the U.S. Collaborative Network to assess the risk of PPB after colorectal EMR in patients with CKD compared to controls. Using one-to-one propensity score matching (PSM), the primary outcome measured was PPB within 30 days after colorectal EMR. The PPB risk was further stratified by CKD severity: non-advanced CKD and advanced CKD. Results After PSM, each cohort included 7,460 patients. Overall, CKD was associated with increased risk of PPB following colorectal EMR (5.5% vs. 4%, odds ratio [OR] 1.38, 95% confidence interval [CI] 1.19–1.61, p < 0.001). The PPB risk was significantly higher in patients with advanced CKD (8.1% vs, 4.6%, OR 1.83, 95% CI 1.43–2.34, p < 0.001), while those with non-advanced CKD showed modest increase in risk of PPB (4.7% vs. 3.9%, OR 1.21, 95% CI 1.001–1.46, p = 0.049). Conclusion Patients with CKD had higher risk of PPB than patients without CKD, but absolute risk remained low. The PPB risk was notably increased in patients with advanced CKD. Optimizing patients with CKD, especially advanced CKD, before colorectal EMR and monitoring for post-procedure bleeding remains important.
Comparable long-term efficacy of cold and hot EMR of large colon polyps – follow up results of a randomized trial
Pohl, Heiko , Rex, Douglas K. , Barber, Judy, Rastogi, A. , Moyer, Matthew T. , Levenick, John M. , Renteln, Daniel von , Gordon, S., Aslanian, Harry R., Elatrache, Mazen, Elmunzer, J, Keswani, Rajesh N. , Kumta, Nikhil A. , M, Ehl, MacKenzie, Todd A. , Piraka, Cyrus , Barber, J, Gordon, S, Wallace, Michael B. , Pleskow, Douglas K. , M, E Tonzi

Mayo Clinic

Endoscopy | March 27, 2025 | Volume: 57 | Issue: No issue available | Pages: No page available

10.1055/s-0045-1805260 Get It

Effect of Glucagon-Like Peptide-1 Receptor Agonists on Bowel Preparation for Colonoscopy: A Systematic Review and Meta-Analysis
Beran, Azizullah , Nayfeh, Tarek , Ramai, Daryl , Mohamed, Mouhand , Guardiola, John , Al‐Haddad, Mohammad , Rex, Douglas K. , Mohamed, Mouhand F H , Guardiola, John J , Al-Haddad, Mohammad , Rex, Douglas K , Nayfeh, Tarek , Akhras, Aya

Mayo Clinic

American Journal of Gastroenterology | February 11, 2025 | Volume: 120 | Issue: 7 | Pages: 1653-1656

10.14309/ajg.0000000000003362 | PMID 39933910 Get It

INTRODUCTION: The impact of glucagon-like peptide-1 receptor agonists (GLP-1RAs) on colonoscopy bowel preparation is unclear. METHODS: We searched multiple databases for studies comparing bowel preparation quality between GLP-1RA users and the control group. Using a random-effects model, we calculated pooled odds ratios and mean differences with 95% confidence intervals (CIs). Inadequate bowel preparation (IBP) rate was the primary outcome, and Boston Bowel Preparation Scale mean score was the secondary outcome. RESULTS: Five studies with 10,833 patients (n = 5,434 GLP-1RAs vs n = 5,399 control) were included. The IBP rate was higher in the GLP-1RAs group compared with the control group (odds ratios 2.10, 95% CI 1.41–3.13, P = 0.0003). Furthermore, the mean Boston Bowel Preparation Scale score was lower in the GLP1-RAs group compared with the control group (mean differences −0.34; 95% CI −0.51, −0.17; P = 0.0001). DISCUSSION: Our findings suggest that using GLP-1RA increases the risk of IBP.
Risk of Post-polypectomy Bleeding After Colorectal Endoscopic Mucosal Resection in Patients With Cirrhosis: A Propensity-Matched Analysis of the US Collaborative Network
Beran, Azizullah , Elfert, Khaled , Patel, Feenalie N. , Mohamed, Mouhand , Ramai, Daryl , Canakis, Andrew , Thakkar, Shyam , Rex, Douglas K. , Bhavsar‐Burke, Indira , Guardiola, John , Guardiola, John J , Canakis, Andrew , Mohamed, Mouhand F H

Mayo Clinic

American Journal of Gastroenterology | January 16, 2025 | Volume: 120 | Issue: 11 | Pages: 2687-2691

10.14309/ajg.0000000000003322 | PMID 39950371 Get It

INTRODUCTION: Data on the risk of post-polypectomy bleeding after endoscopic mucosal resection (EMR) in patients with cirrhosis are limited. METHODS: This retrospective cohort study used the US Collaborative Network to assess post-polypectomy bleeding risk after colorectal EMR in patients with cirrhosis compared with controls. Using one-to-one propensity score matching, the primary outcome measured was bleeding within 30 days post-EMR. The bleeding risk was further stratified by cirrhosis severity (compensated and decompensated). RESULTS: After propensity score matching, each cohort included 2,381 patients. Patients with cirrhosis had a higher risk of post-polypectomy bleeding (odds ratio [OR] 1.38, 95% confidence interval [CI] 1.05–1.82, P = 0.02). However, endoscopic reinterventions for hemostasis were similar between cirrhosis and control cohorts (OR 1.20, 95% CI 0.71–2.05, P = 0.50). The post-polypectomy bleeding risk was significantly higher in patients with decompensated cirrhosis (OR 1.65, 95% CI 1.12–2.42, P = 0.01), while those with compensated cirrhosis showed no increased risk of post-polypectomy bleeding (OR 1.15, 95% CI 0.85–1.54, P = 0.37). DISCUSSION: The post-polypectomy bleeding risk was higher in patients with decompensated cirrhosis, while the bleeding risk was not increased in those with compensated disease. Optimizing patients with cirrhosis, especially with decompensated disease, before colorectal EMR and monitoring for post-procedure bleeding remain important. A conservative, supportive approach to managing bleeding in patients with cirrhosis may be as effective as in those without cirrhosis.
S269 Risk of Bleeding After Colorectal Endoscopic Mucosal Resection in Patients With Chronic Kidney Disease: A Propensity-Matched Analysis of the US Collaborative Network
Abosheaishaa, Hazem , Mohamed, Mouhand , Nassar, Mahmoud , Thakkar, Shyam , Rex, Douglas, Guardiola, John, Mohamed, Mouhand F H , Elfert, Khaled , Beran, Azizullah , Abosheaishaa, Hazem Maarouf , Bhavsar‐Burke, Indira

Mayo Clinic

American Journal of Gastroenterology | October 24, 2024 | Volume: 119 | Issue: 10S | Pages: S191-S192

10.14309/01.ajg.0001030444.55862.bc Get It