Citations

Clear

3 citation(s) found for "Ren, Lei".

Generative AI, foundation models and large language models in radiation therapy physics: Clinical applications, challenges, and future directions
Qi, X. Sharon, Wang, Yi, Yang, Xiaofeng, Ren, Lei , Liu, Wei, Benedict, Stanley , Xiao, Ying , Xing, Lei , Naqa, Issam M. El, Qi, X. Sharon , Qi, X. Sharon, Yang, Xiaofeng

Mayo Clinic

Medical Physics | August 7, 2026 | Volume: 53 | Issue: 8 | Pages: No page available

10.1002/mp.70616 | PMID 42563397 Get It

Abstract Generative AI (Gen AI), Foundation Models (FMs), and Large Language Models (LLMs) are powerful emerging technologies that demonstrate exceptional capabilities in processing vast amounts of unstructured and structured data, including text, voice, images, video and other formats, and adapting to a wide range of specific tasks. Their immense potential to drive meaningful improvements in treatment outcomes is increasingly evident. The advent of these technologies has marked a transformative era in healthcare, including the fields of radiation oncology and medical physics. Specifically, these powerful technologies offer unprecedented opportunities to analyze domain‐specific data, process and synthesize medical images, automate routine tasks, support clinical decision‐making, optimize and streamline clinical workflows, and enhance the quality of clinical trials. While these emerging technologies present new opportunities to revolutionize radiation therapy practice, their implementation also raises important educational, ethical, and regulatory considerations. This scoping review highlights benefits, promises, risks, and challenges, such as interpretability, data privacy, regulatory compliance, reproducibility, hallucination, and integration into existing clinical workflow. Finally, emerging opportunities are outlined to guide future research directions. This review paper provides a timely overview of Gen AI, FMs and LLMs, aiming to inform medical physicists, clinicians, and researchers of the evolving role of these disruptive technologies in shaping the future of radiation therapy.
Prostate-specific membrane antigen PET response associates with radiographic progression-free survival following stereotactic ablative radiation therapy in oligometastatic castration-sensitive prostate cancer.
Sutera, Philip , Deek, Matthew P. , Rowe, Steven P. , Kiess, Ana P. , Oymak, Ezgi , Feng, Felix Y. , Phillips, Ryan , Onal, Huseyin Cem, Güler, Ozan Cem , Hürmüz, Pervin , Reyhan, Mehmet , Hrinivich, William Thomas , Ren, Lei, Song, Daniel Y. , Pienta, Kenneth J , Pomper, Martin G. , Özyiğit, Gökhan , Tran, Phuoc T , Onal, Huseyin Cem

Mayo Clinic

Journal of Clinical Oncology | June 6, 2022 | Volume: 40 | Issue: 16_suppl | Pages: 5011-5011

10.1200/jco.2022.40.16_suppl.5011 Get It

5011 Background: Emerging data suggest metastasis-directed therapy (MDT) improves outcomes in patients with oligometastatic castration-sensitive prostate cancer (omCSPC). Prostate-specific membrane antigen positron emission tomography (PSMA-PET/CT) can detect occult metastatic disease and has been proposed as a biomarker for treatment response. Herein we identify and validate a PSMA-PET biomarker for clinical outcomes following MDT in omCSPC. Methods: This was an international multi-institutional retrospective study of two completely independent cohorts of men with omCSPC, defined as ≤3 lesions, treated with metastasis-directed stereotactic ablative radiation therapy (SABR) who underwent PSMA-PET/CT prior to and 3-6 months after treatment. Pre- and post-SABR PSMA-PET/CT standardized uptake value (SUV) was measured for all lesions and PSMA response defined discretely using a cutpoint of ≥ 30% decrease in SUVmax. PSMA-PET response was correlated with lesion local control (LLC), radiographic progression-free survival (rPFS) defined using conventional and PET imaging, and metastasis-free survival (MFS) defined by conventional imaging alone. Results: A total of 131 patients with 261 treated metastases were included in the analysis, with median follow-up of 29 months (IQR 18.5-41.3). Following SABR, 78.4% of lesions experienced a partial or complete PSMA response. Multivariable analysis demonstrated SUV response significantly associated with improved LLC (HR = 9.97, 95%CI 3.92-25.4; p < 0.01). Patients with PSMA response in all lesions experienced significantly better rPFS (HR = 0.49, 95%CI 0.26-0.92; p = 0.03) compared to their counterparts and this maintained significance within both the discovery (p < 0.01) and validation (p = 0.01) cohorts. Within the discovery cohort, patients with PSMA response in all lesions also experienced significantly improved MFS (HR = 0.24, 95%CI 0.07-0.85; p = 0.03); analysis of the independent validation cohort is ongoing. Conclusions: Following SABR, PSMA-PET response is a robust and externally validated radiographic biomarker for rPFS and appears to be associated with MFS pending validation. This approach holds promise for guiding clinical management of omCSPC.
Patient-specific deep learning model to enhance 4D-CBCT image for radiomics analysis
Zhang, Zeyu , Huang, Mi , Jiang, Zhuoran , Chang, Yushi , Lü, Ke , Yin, F , Tran, Phuoc , Wu, Dapeng , Beltran, Chris , Ren, Lei , Beltran, Chris J

Mayo Clinic

Physics in Medicine & Biology | March 21, 2022 | Volume: 67 | Issue: 8 | Pages: 085003

10.1088/1361-6560/ac5f6e | PMID 35313293 Get It

Abstract Objective. 4D-CBCT provides phase-resolved images valuable for radiomics analysis for outcome prediction throughout treatment courses. However, 4D-CBCT suffers from streak artifacts caused by under-sampling, which severely degrades the accuracy of radiomic features. Previously we developed group-patient-trained deep learning methods to enhance the 4D-CBCT quality for radiomics analysis, which was not optimized for individual patients. In this study, a patient-specific model was developed to further improve the accuracy of 4D-CBCT based radiomics analysis for individual patients. Approach. This patient-specific model was trained with intra-patient data. Specifically, patient planning 4D-CT was augmented through image translation, rotation, and deformation to generate 305 CT volumes from 10 volumes to simulate possible patient positions during the onboard image acquisition. 72 projections were simulated from 4D-CT for each phase and were used to reconstruct 4D-CBCT using FDK back-projection algorithm. The patient-specific model was trained using these 305 paired sets of patient-specific 4D-CT and 4D-CBCT data to enhance the 4D-CBCT image to match with 4D-CT images as ground truth. For model testing, 4D-CBCT were simulated from a separate set of 4D-CT scan images acquired from the same patient and were then enhanced by this patient-specific model. Radiomics features were then extracted from the testing 4D-CT, 4D-CBCT, and enhanced 4D-CBCT image sets for comparison. The patient-specific model was tested using 4 lung-SBRT patients’ data and compared with the performance of the group-based model. The impact of model dimensionality, region of interest (ROI) selection, and loss function on the model accuracy was also investigated. Main results. Compared with a group-based model, the patient-specific training model further improved the accuracy of radiomic features, especially for features with large errors in the group-based model. For example, the 3D whole-body and ROI loss-based patient-specific model reduces the errors of the first-order median feature by 83.67%, the wavelet LLL feature maximum by 91.98%, and the wavelet HLL skewness feature by 15.0% on average for the four patients tested. In addition, the patient-specific models with different dimensionality (2D versus 3D) or loss functions (L1 versus L1 + VGG + GAN) achieved comparable results for improving the radiomics accuracy. Using whole-body or whole-body+ROI L1 loss for the model achieved better results than using the ROI L1 loss alone as the loss function. Significance. This study demonstrated that the patient-specific model is more effective than the group-based model on improving the accuracy of the 4D-CBCT radiomic features analysis, which could potentially improve the precision for outcome prediction in radiotherapy.