Citations

Clear

7 citation(s) found for "Rastogi, Amit".

Environmental impact of computer-aided diagnosis in colonoscopy: a carbon footprint assessment of a prospective study cohort
Olabintan, Olaolu , Halvorsen, Natalie , Baddeley, Robin , Kudo, Shin-ei, Barua, Ishita , Misawa, Masashi , Hunt, Claire , Nilsen, Jens Aksel , Frigstad, Svein Oskar , Rastogi, Amit, Holme, Øyvind , Gulati, Shraddha , Hassan, Cesare , Hayee, Bu , Mori, Yuichi , Kudo, Shin-ei, Mori, Kensaku , Hunt, Claire, East, James E. , Hassan, Cesare , Kalager, Mette , Løberg, Magnus , Haji, Amyn , Bretthauer, Michael , Mori, Yuichi

Mayo Clinic

Endoscopy | October 7, 2025 | Volume: 58 | Issue: 03 | Pages: 303-309

10.1055/a-2717-8365 | PMID 41056995 Get It

Abstract The environmental impact of computer-aided diagnosis (CADx) in colonoscopy is unknown. The potential to reduce greenhouse gas emissions by limiting unnecessary polypectomies may be offset by emissions associated with CADx devices. We quantified and compared the carbon footprint of colonoscopy with and without CADx. Life-cycle carbon emissions associated with endoscopic snares, polyp traps, histopathology, and CADx devices were estimated using life-cycle assessment software. The effect of CADx was estimated by the carbon dioxide equivalent (CO2e) emissions related to outcomes from a prospective cohort of patients who underwent colonoscopy with optical diagnosis under a leave-in-situ strategy (i.e. rectosigmoid polyps ≤5 mm predicted as non-neoplastic were not removed) with and without CADx assistance. We analyzed 1134 individuals (median age 67 years, 59% male) with 1716 colorectal polyps. Colonoscopy with CADx reduced the number of snares and polyp traps from 567 to 543 (difference: 24) and histopathology submissions from 1343 to 1278 (difference: 65). However, the total carbon footprint increased from 832 kg CO2e (95%CI 815 to 847) without CADx to 946 kg CO2e (95%CI 927 to 965) with CADx, corresponding to an absolute increase of 114 kg CO2e (95%CI 80 to 150) or 0.10 kg CO2e per colonoscopy. Using CADx under a leave-in-situ strategy increased the environmental burden of colonoscopy.
Adverse events of cold snare compared with hot snare and ablation endoscopic mucosal resection for large colorectal polyps
Medawar, Edgard , Pohl, Heiko , Rex, Douglas K. , Levenick, John M. , Pleskow, Douglas K. , Khashab, Mouen A. , Moyer, Matthew T. , Melson, Joshua , Wallace, Michael B. , Mosko, Jeffrey D. , Singh, Ajaypal , Gavrić, Aleksandar , Gordon, Stuart R. , Ngamruengphong, Saowanee , Taunk, Pushpak, Barber, Jeremy, Piraka, Cyrus , Elmunzer, B. Joseph , Aslanian, Harry R., Elatrache, Mazen, Zolotarevsky, Eugene, Rastogi, Amit , Renteln, Daniel von , Consortium, Additional members of the Large Polyp Study, Wallace, Michael B , Shahidi, Neal , Djinbachian, Roupen , von Renteln, Daniel , Pleskow, Douglas , Yang, Dennis J. , Djinbachian, Roupen , Consortium, Additional members of the Large Polyp Study

Mayo Clinic

Endoscopy | July 24, 2025 | Volume: 58 | Issue: 02 | Pages: 163-173

10.1055/a-2665-0521 | PMID 40719106 Get It

Abstract Endoscopic mucosal resection (EMR) techniques for large (≥20 mm) nonpedunculated colorectal polyps (LNPCPs) have expanded with the introduction of ablation and cold EMR. This study assessed adverse events (AEs) for the newer EMR techniques, including cold EMR, compared with hot EMR. We conducted a secondary analysis of four prospective multicenter studies of consecutive patients with LNPCPs undergoing EMR from 2019 to 2024. The primary outcome was serious AEs (SAEs) with cold and hot EMR. Secondary outcomes included SAEs in the hot EMR subgroups (no ablation [hEMR], margin ablation [hEMR-m], margin and base ablation [hEMR-mb]). 1762 patients (mean age 65.8; 1890 LNPCPs) were included: 522 cold and 1368 hot EMRs (368 hEMR, 770 hEMR-m, 230 hEMR-mb). SAEs were higher with hot EMR (4.7%, 95%CI 3.6%–5.9%) vs. cold EMR (1.9%, 95%CI 0.9%–3.5%), also for the subgroups of hEMR (6.0%, 95%CI 3.8%–8.9%), hEMR-m (3.9%, 95%CI 2.6%–5.5%), and hEMR-mb (5.2%, 95%CI 2.7%–8.9%). Serious postendoscopic bleeding (PEB) was numerically higher with hot EMR (2.3%, 95%CI 1.6%–3.3%) vs. cold EMR (1.3%, 95%CI 0.5%–2.7%), also for the subgroups of hEMR (3.0%, 95%CI 1.5%–5.3%), hEMR-m (1.9%, 95%CI 1.1%–3.2%), and hEMR-mb (2.6%, 95%CI 1.0%–5.6%). Perforation, intraprocedural and post-procedural, was numerically higher with hot EMR (1.2%, 95%CI 0.7%–2.0%) vs. cold EMR (0.2%, 95%CI 0.0%–1.1%). hEMR-m and hEMR-mb with clipping had lower rates of serious and overall PEB than no clipping. Cold EMR demonstrated lower rates of SAEs, serious PEB, and perforation compared with hot EMR. Perforation and mortality occurred almost exclusively after hot EMR. Hot EMR with margin +/− base ablation did not increase SAEs compared with hot EMR without ablation.
Cold snare endoscopic resection for large colon polyps: a randomised trial
Pohl, Heiko , Rex, Douglas K. , Barber, Jeremy, Moyer, Matthew T. , Elmunzer, B. Joseph , Rastogi, Amit , Gordon, Stuart R. , Zolotarevsky, Eugene, Levenick, John M. , Aslanian, Harry R., Elatrache, Mazen, Renteln, Daniel von , Brahmbhatt, Bhaumik , Keswani, Rajesh N. , Kumta, Nikhil A. , Smith, Zachary L. , Ghanimeh, Mouhanna K. Abu, Simmer, Stephen, MacKenzie, Todd A. , Piraka, Cyrus , von Renteln, Daniel , Smith, Zachary L , Piraka, Cyrus , Wallace, Michael B. , Pleskow, Douglas K. , Sanaei, Omid

Mayo Clinic

Gut | May 20, 2025 | Volume: 74 | Issue: 11 | Pages: 1804-1813

10.1136/gutjnl-2025-335075 | PMID 40393701 Get It

Background Complications of endoscopic mucosal resection (EMR) of large colorectal polyps remain a concern. Objective We aimed to compare safety and efficacy of cold EMR (without electrocautery) to hot EMR (with electrocautery) of large colorectal polyps. Design In this multicentre randomised trial, patients with any large (≥20 mm) non-pedunculated colon polyp were assigned to cold or hot EMR (primary intervention), and to submucosal injection with a viscous or non-viscous solution (secondary intervention) following a 2×2 design. The primary outcome was the rate of severe adverse events (SAEs). The secondary outcome was polyp recurrence. In this study, we report results of the primary intervention. Results 660 patients were randomised and analysed. An SAE was observed in 2.1% of patients in the cold EMR group and in 4.3% in the hot EMR group (p=0.10) (per protocol analysis 1.4 vs 5.0%, p=0.017) with fewer perforations following cold EMR (0%) compared with hot EMR (1.6%, p=0.028). Postprocedure bleeding did not differ (1.5% vs 2.2%, p=0.57). The effect of cold resection was independent of the type of submucosal injection solution, polyp size or antithrombotic medications. Recurrence was detected in 27.6% and 13.6% in the cold and hot EMR groups, respectively (p<0.001). Recurrence was not significantly different for 20–29 mm polyps (18.6% vs 13.4%, p=0.24) and for sessile serrated polyps (14.1% vs 8.5%, p=0.33). Conclusion Universal application of cold EMR did not significantly lower SAEs (unless cold EMR could be completed) and doubled the recurrence rate compared with hot EMR. Trial registration details ClinicalTrials.gov, number: NCT03865537 .
Technical Factors Associated With the Benefit of Prophylactic Pancreatic Stent Placement During High-Risk Endoscopic Retrograde Cholangiopancreatography: A Secondary Analysis of the SVI Trial Data Set
Elmunzer, B. Joseph , Zhang, Jingwen , Coté, Gregory A. , Wani, Sachin , Shah, Raj J. , Bang, Ji Young , Varadarajulu, Shyam , Singh, Vikesh K. , Khashab, Mouen A. , Kwon, Richard S. , Scheiman, James M., Keilin, Steven , Chak, Amitabh , Slivka, Adam, Mullady, Daniel , Kushnir, Vladimir , Buxbaum, James , Keswani, Rajesh N. , Gardner, Timothy B. , Forbes, Nauzer , Rastogi, Amit, Ross, Andrew S., Law, Joanna K. , Chen, Yen‐I , Smith, Zachary L. , Petersen, Bret T. , Wang, Andrew Y. , Saltzman, John R. , Spitzer, Rebecca L., Ordiah, Collins, Spino, Cathie , Foster, Lydia D. , Durkalski‐Mauldin, Valerie, Group*, on behalf of the SVI Study, Shah, Raj , Singh, Vikesh K , Kwon, Richard S , Willingham, Field F , Chak, Amitabh , Mullady, Daniel , Forbes, Nauzer , Ross, Andrew , Law, Joanna , Chen, Yen-I , Smith, Zachary L , Serrano, Jose , Petersen, Bret, Wang, Andrew Y , Saltzman, John R , Spino, Cathie , Foster, Lydia D , Edmundowicz, Steven A. , Willingham, Field F. , Papachristou, Georgios I. , Yachimski, Patrick , Barkun, Alan , Serrano, José , Group*, on behalf of the SVI Study

Mayo Clinic

American Journal of Gastroenterology | August 27, 2024 | Volume: 120 | Issue: 4 | Pages: 811-815

10.14309/ajg.0000000000003052 | PMID 39207308 Get It

INTRODUCTION: Prophylactic pancreatic stent placement (PSP) is effective for preventing pancreatitis after endoscopic retrograde cholangiopancreatography (ERCP) in high-risk cases, but the optimal technical approach to this intervention remains uncertain. METHODS: In this secondary analysis of 787 clinical trial patients who underwent successful stent placement, we studied the impact of (i) whether pancreatic wire access was achieved for the sole purpose of PSP or naturally during the conduct of the case, (ii) the amount of effort expended on PSP, (iii) stent length, (iv) stent diameter, and (v) guidewire caliber. We used logistic regression models to examine the adjusted association between each technical factor and post-ERCP pancreatitis (PEP). RESULTS: Ninety-one of the 787 patients experienced PEP. There was no clear association between PEP and whether pancreatic wire access was achieved for the sole purpose of PSP (vs occurring naturally; odds ratio [OR] 0.82, 95% confidence interval [CI] 0.37–1.84), whether substantial effort expended on stent placement (vs nonsubstantial effort; OR 1.58, 95% CI 0.73–3.45), stent length (>5 vs ≤5 cm; OR 1.01, 95% CI 0.63–1.61), stent diameter (≥5 vs <5 Fr; OR 1.13, 95% CI 0.65–1.96), or guidewire caliber (0.035 vs 0.025 in; 0.83, 95% CI 0.49–1.41). DISCUSSION: The 5 modifiable technical factors studied in this secondary analysis of large-scale randomized trial data did not appear to have a strong impact on the benefit of prophylactic PSP in preventing PEP after high-risk ERCP. Within the limitations of post hoc subgroup analysis, these findings may have important implications in procedural decision making and suggest that the benefit of PSP is robust to variations in technical approach.
International consensus on the management of large (≥20 mm) colorectal laterally spreading tumors: World Endoscopy Organization Delphi study
Rex, Douglas K. , Aihara, Hiroyuki , Bastiaansen, Barbara A.J. , Bechara, Robert , Bhatt, Amit , Bourke, Michael J. , Byeon, Jeong‐Sik , Chino, Akiko , Goldblum, John R. , Ho, Shiaw Hooi , Jung, Yunho , Kawachi, Hiroshi , Khashab, Mouen A., Khomvilai, Supakij , Messmann, Helmut , Mori, Yuichi, Nakanishi, Yukihiro , Ngamruengphong, Saowanee , Parra‐Blanco, Adolfo , Pinto, Rafael Castilho , Pioche, Mathieu , Pohl, Heiko , Rastogi, Amit , Repici, Alessandro , Sethi, Amrita , Suzuki, Noriko, Tanaka, Shinji , Vieth, Michael, Yokoi, Chizu , Saito, Yutaka , Renteln, Daniel von , Chino, Akiko , Chiu, Philip Wai Yan , Elkholy, Shaimaa , Kawachi, Hiroshi , Yamamoto, Hironori , Yang, Dong-Hoon , Saito, Yutaka , Bhatt, Amit , Bechara, Robert , Djinbachian, Roupen , Chiu, Han‐Mo , Fukami, Norio , Bhandari, Pradeep , Cardoso, Daniela, Dekker, Evelien , Draganov, Peter V. , Emura, Fabian , Haji, Amyn , Khashab, Mouen A. , Kim, Eun Ran , Maselli, Roberta , Moons, Leon M.G. , Pellisé, Maria , Singh, Rajvinder

Mayo Clinic

Digestive Endoscopy | June 27, 2024 | Volume: 36 | Issue: 11 | Pages: 1253-1268

10.1111/den.14826 | PMID 38934243 Get It

ObjectivesThere have been significant advances in the management of large (≥20 mm) laterally spreading tumors (LSTs) or nonpedunculated colorectal polyps; however, there is a lack of clear consensus on the management of these lesions with significant geographic variability especially between Eastern and Western paradigms. We aimed to provide an international consensus to better guide management and attempt to homogenize practices.MethodsTwo experts in interventional endoscopy spearheaded an evidence‐based Delphi study on behalf of the World Endoscopy Organization Colorectal Cancer Screening Committee. A steering committee comprising six members devised 51 statements, and 43 experts from 18 countries on six continents participated in a three‐round voting process. The Grading of Recommendations, Assessment, Development and Evaluations tool was used to assess evidence quality and recommendation strength. Consensus was defined as ≥80% agreement (strongly agree or agree) on a 5‐point Likert scale.ResultsForty‐two statements reached consensus after three rounds of voting. Recommendations included: three statements on training and competency; 10 statements on preresection evaluation, including optical diagnosis, classification, and staging of LSTs; 14 statements on endoscopic resection indications and technique, including statements on en bloc and piecemeal resection decision‐making; seven statements on postresection evaluation; and eight statements on postresection care.ConclusionsAn international expert consensus based on the current available evidence has been developed to guide the evaluation, resection, and follow‐up of LSTs. This may provide guiding principles for the global management of these lesions and standardize current practices.
Expert endoscopist assessment of colorectal polyp size using virtual scale endoscopy, visual or snare-based estimation: a prospective video-based study
Crainic, Ioana Popescu, Rex, Douglas K. , Hassan, Cesare , Pohl, Heiko , Rastogi, Amit, Anderson, Joseph C. , Taghiakbari, Mahsa , Medawar, Edgard , Renteln, Daniel von , East, James, Hassan, Cesare , Djinbachian, Roupen , Barkun, Alan , Shaukat, Aasma , East, James E. , Mori, Yuichi , Sharma, Prateek

Mayo Clinic

Scandinavian Journal of Gastroenterology | February 9, 2024 | Volume: 59 | Issue: 5 | Pages: 608-614

10.1080/00365521.2024.2308519 | PMID 38333956 Get It

Factors associated with complete clip closure after endoscopic mucosal resection of large colorectal polyps
Pohl, Heiko , Ortíz, Oswaldo , Rex, Douglas K. , Moyer, Matthew T. , Hasan, Muhammad K. , Pleskow, Douglas K. , Elmunzer, B. Joseph , Khashab, Mouen A., Al-Kawas, Fíras H. , Gordon, Stuart R. , Abraham, Mathew , Levenick, John M. , Aslanian, Harry R., Renteln, Daniel von , Rastogi, Amit , Gill, Jeffrey, Law, Ryan , Wallace, Michael B. , Elias, Pooja A., MacKenzie, Todd A. , Ortiz, Oswaldo , Pleskow, Douglas , Antaki, Fadi , von Renteln, Daniel , Wallace, Michael B , Pellisé, Maria , Grimm, Ian S. , Khashab, Mouen A. , Sanaei, Omid , Mathew, Abraham, Crockett, Seth D.

Mayo Clinic

Endoscopy | December 9, 2020 | Volume: 53 | Issue: 11 | Pages: 1150-1159

10.1055/a-1332-6727 | PMID 33291159 Get It

Abstract Background and study aim Delayed bleeding is a common adverse event following endoscopic mucosal resection (EMR) of large colorectal polyps. Prophylactic clip closure of the mucosal defect after EMR of nonpedunculated polyps larger than 20 mm reduces the incidence of severe delayed bleeding, especially in proximal polyps. This study aimed to evaluate factors associated with complete prophylactic clip closure of the mucosal defect after EMR of large polyps. Methods This is a post hoc analysis of the CLIP study (NCT01936948). All patients randomized to the clip group were included. Main outcome was complete clip closure of the mucosal resection defect. The defect was considered completely closed when no remaining mucosal defect was visible and clips were less than 1 cm apart. Factors associated with complete closure were evaluated in multivariable analysis. Results In total, 458 patients (age 65, 58 % men) with 494 large polyps were included. Complete clip closure of the resection defect was achieved for 338 polyps (68.4 %); closure was not complete for 156 (31.6 %). Factors associated with complete closure in adjusted analysis were smaller polyp size (odds ratio 1.06 for every millimeter decrease [95 % confidence interval 1.02–1.08]), good access (OR 3.58 [1.94–9.59]), complete submucosal lifting (OR 2.28 [1.36–3.90]), en bloc resection (OR 5.75 [1.48–22.39]), and serrated histology (OR 2.74 [1.35–5.56]). Conclusions Complete clip closure was not achieved for almost one in three resected large nonpedunculated polyps. While stable access and en bloc resection facilitate clip closure, most factors associated with clip closure are not modifiable. This highlights the need for alternative closure options and measures to prevent bleeding.