Citations

Clear

8 citation(s) found for "Patel, Dharmendra".

Conjunctival Biopsy of a Patient With Mpox
Tran, Meagan , Gonzalez, Valeria , Patel, Dharmendra , Shusko, Alexander , McCullough, Ann E. , Shah, Ami, McCullough, Ann, Gonzalez, Valeria V , Shah, Ami A. , Patel, Dharmendra

Mayo Clinic

JAMA Ophthalmology | January 11, 2024 | Volume: 142 | Issue: 2 | Pages: 157

10.1001/jamaophthalmol.2023.5780 | PMID 38206632 Get It

This case report describes a conjunctival biopsy of a patient with mpox infection.
A Case of Sustained Viral Shedding of Mpox With Ocular Involvement Resulting in Vision Loss
Speiser, Lisa , Wonnaparhown, Alex , Blair, Janis E. , Patel, Dharmendra, McCullough, Ann E. , Nicolasora, Nelson, Khalsa, Ann, Orenstein, Robert , Vikram, Holenarasipur R. , Seville, Maria Teresa , Speiser, Lisa J , Wonnaparhown, Alex M, Blair, Janis, Shah, Ami, Vikram, Holenarasipur R. , Shah, Ami A. , Huang, Vivian

Mayo Clinic

Open Forum Infectious Diseases | December 15, 2023 | Volume: 11 | Issue: 1 | Pages: No page available

10.1093/ofid/ofad632 | PMID 38264094 Get It

Abstract Mpox, caused by infection with Monkeypox virus, usually presents as a mild, self-limited illness in immunocompetent persons that resolves within 2–4 weeks. Serious complications have been reported when mpox lesions involve vulnerable anatomic sites, such as the eye, and in those with substantial immunosuppression. We describe a patient with advanced human immunodeficiency virus infection and sustained viral shedding of mpox with ocular involvement, which resulted in vision loss.
Assessment of Cumulative Incidence and Severity of Primary Open-Angle Glaucoma Among Participants in the Ocular Hypertension Treatment Study After 20 Years of Follow-up
Heuer, Dale K. , Higginbotham, Eve J. , Parrish, Richard , Khanna, Cheryl L. , Brandt, James D. , Soltau, Joern B., Keltner, John L., Huecker, Julia B., Wilson, Bradley , Gordon, Mae O. , Group, Ocular Hypertension Study, Gedee, Steven J., Esquiabro, Maria, Fabrizio, Matthew J., Patorgis, Charles J., Long, Teresa A., McManus, Paul E., Washington, Chantura, Chang, Peter , Orengo-Nania, Silvia, Leger, April, Kinast, Robert M. , Jones, Emily P., Goldman, Casie, Beck, Allen D. , Costarides, Anastasios P., Leef, Donna, Imami, Nauman R., Darnley-Fisch, Deborah , Crandall, David, Gutkowski, Melanie, Hall, Julianne, Fantin, Aldo, Wells, Judy, Jampel, Henry , Quigley, Harry A., Miller, Rhonda, Kalarn, Sachin , Coleman, Anne L. , Young, Jonathan W., Peterson, Christine A., Giaconi, JoAnn A. , Law, Simon K., Duarte, Pamela B., Wood, Sarah Dougherty , Moroi, Sayoki, Gilbert, Jesse L., Shukairy, Aman, Juzych, Mark S. , Milanovic, Cheryl, O'Grady, John M., Conett, Linda A. Van, Mohay-Ambrus, Judith, Bottorff, Michelle, Bennett, Jeffrey R., Sultze, Jane L., Patel, Dharmendra, Cobb, Steven H., Bhattacharjee, Pompa, Cioffi, George A., Blumberg, Dana M., Moraes, Carlos Gustavo De , Atakulova, Marzhan, Weber, Paul A., Sawchyn, Andrea K., Williams, Demarcus, Bennett, George, Bennett, Lindsay C., Miller-Ellis, Eydie , Sankar, Prithvi S. , Grand-Drossner, Sheri, Piltz‐Seymour, Jody R., Niemczyk, Jane L., Brandt, James D., Lim, Michelle, Balasubramaniam, Saranya C., Baik, Annie K., Arnold, Marisa S., Slight, J. Rigby, Ou, Yvonne , Lamping, Kathleen A., Vitelli, Cheryl L., Ashburn, Frank S., Hardney, Karen S., Schwartz, Arthur L., Weiss, Howard S., Clark, Clete, Bhorade, Anjali M., Lind, John T., Adcock, Eve, Plumb, Kim, Leming, Laura, Dillon, B A, Palmberg, Paul, Hodapp, Elizabeth, Varner, Elizabeth A., Savatovsky, Eleonore , Vandenbroucke, Ruth, Dirkes, Keri , Vega, Suzanne , Hunsicker, Maria, Proudfoot, J. , Dunn, D, Everett, Donald F., Gutowski, Melanie, Fischbach, Ellen, Clark, Karen A., Morris, Patricia A., Quinn, Melanie, Pistorius, Sam, Haertter, Leonard W., Kass, Michael A. , Johnson, Chris A. , Liu, Lei , Miller, J. Philip , Quigley, Harry A. , Group, Ocular Hypertension Study, Patorgis, Charles J., Washington, Chantura, Mansberger, Steven L. , Wells, Judy, Quigley, Harry A., Saeedi, Osamah J. , Hughes, Bret A. , Liebmann, Jeffrey M. , Al‐Aswad, Lama A. , Brandt, James D., Lim, Michelle C., Weinreb, Robert Neal , Smith, Mike A., Feuer, William J. , Zangwill, Linda M. , Morris, Patricia A.

Mayo Clinic

JAMA Ophthalmology | April 17, 2021 | Volume: 139 | Issue: 5 | Pages: 558

10.1001/jamaophthalmol.2021.0341 | PMID 33856434 Get It

Identifying and Mitigating Design Challenges of Ophthalmology Tele-medicine at Mayo Clinic
Gaffar, Ashraf, Patel, Dharmendra, Pallagi, Peter J. , Gaffar, Rouan, Karami, Mansooreh

Mayo Clinic

2017 International Conference on Computational Science and Computational Intelligence (CSCI) | December 6, 2018 | Volume: No volume available | Issue: No issue available | Pages: 1732-1736

10.1109/csci.2017.301 Get It

A Tele-triage Application Design for Mobile Health at Mayo Clinic
Gaffar, Ashraf, Patel, Dharmendra, Pallagi, Peter J. , Gaffar, Rouan, Karami, Mansooreh

Mayo Clinic

2017 International Conference on Computational Science and Computational Intelligence (CSCI) | December 6, 2018 | Volume: No volume available | Issue: No issue available | Pages: 1720-1725

10.1109/csci.2017.299 Get It

A Disposable Tear Glucose Biosensor—Part 4
Belle, Jeffrey T. La , Engelschall, Erica, Lan, Kenneth, Shah, Pankti, Saez, Neil , Maxwell, Stephanie, Adamson, Teagan, Abou-Eid, Michelle, McAferty, Kenyon, Patel, Dharmendra, Patel, Dharmendra R., Cook, Curtiss B.

Mayo Clinic

Journal of Diabetes Science and Technology | February 11, 2014 | Volume: 8 | Issue: 1 | Pages: 109-116

10.1177/1932296813511741 | PMID 24876546 Get It

Objective: A prototype tear glucose (TG) sensor was tested in New Zealand white rabbits to assess eye irritation, blood glucose (BG) and TG lag time, and correlation with BG. Methods: A total of 4 animals were used. Eye irritation was monitored by Lissamine green dye and analyzed using image analysis software. Lag time was correlated with an oral glucose load while recording TG and BG readings. Correlation between TG and BG were plotted against one another to form a correlation diagram, using a Yellow Springs Instrument (YSI) and self-monitoring of blood glucose as the reference measurements. Finally, TG levels were calculated using analytically derived expressions. Results: From repeated testing carried over the course of 12 months, little to no eye irritation was detected. TG fluctuations over time visually appeared to trace the same pattern as BG with an average lag times of 13 minutes. TG levels calculated from the device current measurements ranged from 4 to 20 mg/dL and correlated linearly with BG levels of 75-160 mg/dL (TG = 0.1723 BG = 7.9448 mg/dL; R 2 = .7544). Conclusion: The first steps were taken toward preliminary development of a sensor for self-monitoring of tear glucose (SMTG). No conjunctival irritation in any of the animals was noted. Lag time between TG and BG was found to be noticeable, but a quantitative modeling to correlate lag time in this study is unnecessary. Measured currents from the sensors and the calculated TG showed promising correlation to BG levels. Previous analytical bench marking showed BG and TG levels consistent with other literature.
A Disposable Tear Glucose Biosensor—Part 3: Assessment of Enzymatic Specificity
Lan, Kenneth, McAferty, Kenyon, Shah, Pankti, Lieberman, Erica, Patel, Dharmendra, Belle, Jeffrey T. La , Cook, Curtiss B.

Mayo Clinic

Journal of Diabetes Science and Technology | January 10, 2014 | Volume: 5 | Issue: 5 | Pages: 1108-1115

10.1177/193229681100500511 | PMID 22027303 Get It

Background: A concept for a tear glucose sensor based on amperometric measurement of enzymatic oxidation of glucose was previously presented, using glucose dehydrogenase flavin adenine dinucleotide (GDH-FAD) as the enzyme. Glucose dehydrogenase flavin adenine dinucleotide is further characterized in this article and evaluated for suitability in glucose-sensing applications in purified tear-like saline, with specific attention to the effect of interfering substances only. These interferents are specifically saccharides that could interact with the enzymatic activity seen in the sensor's performance. Methods: Bench top amperometric glucose assays were performed using an assay solution of GDH-FAD and ferricyanide redox mediator with samples of glucose, mannose, lactose, maltose, galactose, fructose, sucrose, and xylose at varying concentrations to evaluate specificity, linear dynamic range, signal size, and signal-to-noise ratio. A comparison study was done by substituting an equivalent activity unit concentration of glucose oxidase (GOx) for GDH-FAD. Results: Glucose dehydrogenase flavin adenine dinucleotide was found to be more sensitive than GOx, producing larger oxidation currents than GOx on an identical glucose concentration gradient, and GDH-FAD exhibited larger slope response (-5.65 × 10 −7 versus −3.11 × 10 −7 A/mM), signal-to-noise ratio (18.04 versus 2.62), and linear dynamic range (0–30 versus 0–10 mM), and lower background signal (−7.12 versus −261.63 nA) than GOx under the same assay conditions. GDH-FAD responds equally to glucose and xylose but is otherwise specific for glucose. Conclusion: Glucose dehydrogenase flavin adenine dinucleotide compares favorably with GOx in many sensor-relevant attributes and may enable measurement of glucose concentrations both higher and lower than those measurable by GOx. GDH-FAD is a viable enzyme to use in the proposed amperometric tear glucose sensor system and perhaps also in detecting extreme hypoglycemia or hyperglycemia in blood.
A Disposable Tear Glucose Biosensor—Part 2: System Integration and Model Validation
Belle, Jeffrey T. La , Bishop, D. Keith, Vossler, S. R., Patel, Dharmendra R., Patel, Dharmendra R., Cook, Curtiss B.

Mayo Clinic

Journal of Diabetes Science and Technology | January 10, 2014 | Volume: 4 | Issue: 2 | Pages: 307-311

10.1177/193229681000400210 | PMID 20307390 Get It

Background: We presented a concept for a tear glucose sensor system in an article by Bishop and colleagues in this issue of Journal of Diabetes Science and Technology . A unique solution to collect tear fluid and measure glucose was developed. Individual components were selected, tested, and optimized, and system error modeling was performed. Further data on prototype testing are now provided. Methods: An integrated fluidics portion of the prototype was designed, cast, and tested. A sensor was created using screen-printed sensors integrated with a silicone rubber fluidics system and absorbent polyurethane foam. A simulated eye surface was prepared using fluid-saturated poly(2-hydroxyethyl methacrylate) sheets, and the disposable prototype was tested for both reproducibility at 0, 200, and 400 μ M glucose ( n = 7) and dynamic range of glucose detection from 0 to 1000 μ M glucose. Results: From the replicated runs, an established relative standard deviation of 15.8% was calculated at 200 μ M and a lower limit of detection was calculated at 43.4 μ M . A linear dynamic range was demonstrated from 0 to 1000 μ M with an R 2 of 99.56%. The previously developed model predicted a 14.9% variation. This compares to the observed variance of 15.8% measured at 200 μ M glucose. Conclusion: With the newly designed fluidics component, an integrated tear glucose prototype was assembled and tested. Testing of this integrated prototype demonstrated a satisfactory lower limit of detection for measuring glucose concentration in tears and was reproducible across a physiological sampling range. The next step in the device design process will be initial animal studies to evaluate the current prototype for factors such as eye irritation, ease of use, and correlation with blood glucose.