Isatuximab (Isa) subcutaneous (SC) via an on-body injector (OBI) vs isa intravenous (IV), plus pomalidomide and dexamethasone (Pd) in relapsed/refractory multiple myeloma (RRMM): East asia subgroup results from the randomized, non-inferiority, phase 3 irak
Abstract Background: Intravenous (IV) isatuximab plus pomalidomide and dexamethasone (Isa-Pd) is approved for treatment in patients with relapsed/refractory multiple myeloma (RRMM) based on the ICARIA-MM study. Subcutaneous (SC) administration of Isa offers potential advantages such as shorter administration duration and greater patient comfort compared with IV routes. Isa SC via an on-body injector (OBI), an investigational wearable bolus injector, demonstrated safety and efficacy in a Phase 1b study in patients with RRMM. The IRAKLIA trial (NCT05405166) was the first Phase 3 trial evaluating the non-inferiority of Isa-Pd SC via an OBI vs Isa-Pd IV in patients with RRMM. Here, we report the findings of the IRAKLIA trial in the East Asian subgroup with RRMM. Methods: This global, multicenter, open-label study enrolledpatients aged ≥18 years with RRMM who had received ≥1 prior line of therapy (LOT) including lenalidomide and a proteasome inhibitor (PI). Patients were randomized 1:1 to Isa SC (1400 mg) or Isa IV (10 mg/kg) weekly in Cycle (C)1, then every 2 weeks in addition to P (4 mg orally daily, Day [D]1-21) and d (40 mg orally [20 mg if age ≥75 years] weekly). Treatment was administered in 4-week cycles and continued until disease progression, unacceptable toxicity, or patient withdrawal. Co-primary endpoints included overall response rate (ORR) and observed Isa concentration before dosing (Ctrough) at steady state (predose at C6D1). Key secondary endpoints included rate of very good partial response or better (≥VGPR), Ctroughlevel Cycle 2 Day 1 (C2D1), infusion reaction incidence, and patient satisfaction rate based on the patient experience and satisfaction questionnaire (PESQ) at C5D15. Results: The East Asian subgroup consisted of 105 patients from China (Mainland, n=82 and Taiwan, n=1) and Japan(n=22) (SC, n=50; IV, n=55). Baseline characteristics of the East Asian subgroup were generally balanced between the two arms and generally comparable to the overall global population (median age 62 years; median 2 prior LOT; 29.5% high-risk cytogenetics; 82.9% refractory to lenalidomide; 7.6% prior exposure to daratumumab). After a median of 13.0 months follow-up, ORR in the SC and IV arm was 74.0% and 70.9%, respectively (relative risk [95% CI] = 1.044 [0.815 – 1.335]). The mean (SD) of Ctroughat C6D1 was 502 (232) µg/mL for SC arm and 282 (123) µg/mL for IV arm. The geometric mean ratio (90% CI) comparing SC to IV for Ctrough at steady state was 1.756 (1.346 – 2.290). The ≥VGPR rates were 58.0% for SC and 50.9% for IV (relative risk [95% CI] = 1.139 [0.798 – 1.631]). The mean(SD) of C2D1 Ctroughlevel was 420 (161) µg/mL for the SC arm and 262 (111) µg/mL for IV arm. The geometric mean ratio (90% CI) comparing SC to IV for Ctrough at C2D1 was 1.673 (1.321 to 2.120). The infusion reaction incidence was 0% and 21.8% for SC and IV, respectively. Grade ≥3treatment-emergent adverse events were observed in 82.0% and 87.3% of patients in the SC and IV arms, respectively. Treatment discontinuation rates were 6% for the SC arm and 12.7% for the IV arm. Injection site reactions (ISRs) occurred in 4% (2/50) of patients in the SC arm and in 0.21% (2/964) of SC injections (all Grade 1), with 99.3% of SC injections completed successfully. Isa SC patients expressed higher satisfaction with their injection method, with 64.0% of patients reporting “satisfied” or “very satisfied” vs 52.7% of Isa IV patients (odds ratio [95% CI] = 1.594 [0.728 – 3.489]). Conclusions: The efficacy, safety and pharmacokinetic results between Isa SC vs IV + Pd in the East Asian population from the IRAKLIA study were consistent with the results of the overall global population, in which non-inferiority of ORR, Ctrough at C6D1, ≥VGPR and Ctrough at C2D1 was demonstrated and statistically significantly fewer infusion reactions and higher patient satisfaction were also noted for SC vs IV. These results support the potential use of Isa SC delivered via OBI in East Asian patients and demonstrate the potential of this delivery method to improve patient experience and practice efficiency.
Explore the feasibility of using spot‐scanning proton arc therapy for a synchrotron accelerator‐based proton therapy system – A simulation study
AbstractObjectiveThe aim of this study was to evaluate the feasibility and plan quality of spot‐scanning proton arc therapy (SPArc) using a synchrotron‐accelerator‐based proton therapy system compared to intensity‐modulated proton therapy (IMPT).ApproachFive representative disease sites, including head and neck, lung, liver, brain chordoma, and prostate cancers, were retrospectively selected. Both IMPT and SPArc plans are generated with the HITACHI ProBEAT PBS system's minimum MU constraints and physics beam model. The SPArc plans are generated with 2.5° sampling frequency. The static delivery time was simulated based on the previously published synchrotron delivery sequence model, and the dynamic delivery time was simulated using a proton arc gantry mechanical model integrated with the synchrotron delivery sequence. Both dosimetric plan quality and delivery efficiency are evaluated.Main resultsA superior plan quality is reached compared with the IMPT plans generated for the same disease site. However, a relatively prolonged static and dynamic delivery time post new challenge, as static time increased by 49.22% and dynamic time 59.10% on average.SignificanceThis study presents the first simulation results of delivering the SPArc plans using a synchrotron‐accelerated proton therapy system. The result shows its feasibility and limitations, which could guide future development.
Determinants of successful ictal SPECT injection in phase 1 epilepsy presurgical evaluation: Findings from the pediatric epilepsy research consortium surgery database project
AbstractObjectivesThe main goal of presurgical evaluation in drug‐resistant focal epilepsy is to identify a seizure onset zone (SOZ). Of the noninvasive, yet resource‐intensive tests available, ictal single‐photon emission computed tomography (SPECT) aids SOZ localization by measuring focal increases in blood flow within the SOZ via intravenous peri‐ictal radionuclide administration. Recent studies indicate that geographic and center‐specific factors impact utilization of these diagnostic procedures. Our study analyzed successful ictal SPECT acquisition (defined as peri‐ictal injection during inpatient admission) using surgery‐related data from the Pediatric Epilepsy Research Consortium (PERC) surgery database. We hypothesized that a high seizure burden, longer duration of video EEG monitoring (VEEG), and more center‐specific hours of SPECT availability would increase the likelihood of successful ictal SPECT.MethodsWe identified study participants (≤18 years of age) who underwent SPECT as part of their phase 1 VEEG from January 2018 to June 2022. We assessed association between ictal SPECT outcomes (success vs. failure) and variables including patient demographics, epilepsy history, and center‐specific SPECT practices.ResultsPhase 1 VEEG monitoring with ictal SPECT injection was planned in 297 participants and successful in 255 participants (85.86%). On multivariable analysis, the likelihood of a successful SPECT injection was higher in patients of non‐Hispanic ethnicity (p = 0.040), shorter duration VEEG (p = 0.004), and higher hours of available SPECT services (p < 0.001). Higher seizure frequency (p = 0.033) was significant only in bivariate analysis. Patients treated at centers with more operational hours were more likely to experience pre‐admission protocols prior to VEEG (p = 0.002).SignificanceThere is inter‐center variability in protocols and SPECT acquisition capabilities. Shorter duration of EEG monitoring, non‐Hispanic ethnicity (when on private insurance), extended operational hours of nuclear medicine as noted on multivariate analysis and higher seizure frequency in bivariate analysis are strongly associated with successful ictal SPECT injection.Plain Language SummaryIn pediatric patients with drug‐resistant epilepsy, single‐photon emission computed tomography (SPECT) scans can be helpful in localizing seizure onset zone. However, due to many logistical challenges described below, which include not only the half‐life of the technetium isotope used to inject intravenously during a seizure (called the ictal SPECT scan) but also available nuclear scanner time in addition to the unpredictability of seizures, obtaining an ictal SPECT during a planned elective inpatient hospital stay is not guaranteed. Thus, as healthcare costs increase, planning a prolonged hospital stay during which an ictal SPECT scan is not feasible is not optimal. We leveraged our prospective surgery database to look at center‐specific factors and patient‐specific factors associated with an ictal SPECT injection in the first, pediatric‐focussed, large‐scale, multicenter, prospective, SPECT feasibility study. We found that longer availability of the scanner is the most important center‐specific factor in assuring ictal SPECT injection. Although seizure frequency is an important patient‐specific factor on bivariate analysis, this factor lost statistical significance when other factors like patient insurance status and video EEG duration were also considered in our multivariable logistical model.
Comparing in vivo wave-based elastography with ex vivo mechanical testing in porcine vessels
Arterial stiffness predicts cardiovascular disease, the leading cause of death worldwide. Ultrasound elastography methods that measure wave velocity have promise for evaluating the stiffness of blood vessels in vivo. However, vessel geometry modulates wave velocity by inducing geometric dispersion. Here, we compare Young's modulus E estimates obtained using in vivo wave velocity measurements and techniques that either do or do not consider geometry to ex vivo reference E values from mechanical testing . An acoustic radiation force was applied to generate propagating waves in the right common carotid artery (N = 9) and external jugular vein (N = 10) of anesthetized pigs. Vessels were imaged with ultrafast ultrasound to measure wave motion. Group velocity cg was estimated from wave motion using a Radon transform. E was estimated from cg using a bulk media assumption which neglects geometry, as well as the Moens–Korteweg equation and a semi-analytical finite element model, which consider geometry. Pigs were euthanized and vessels were excised. Ring-shaped samples were extracted and tested in a uniaxial tension setup to obtain reference E values for comparison with E values obtained from wave-based techniques. Techniques considering geometry exhibited higher correlation with reference E values, underscoring the need to incorporate geometry for accurate vascular elastography assessments.
Building a precise machine-specific time structure of the spot and energy delivery model for a cyclotron-based proton therapy system
Abstract Objective . We proposed an experimental approach to build a precise machine-specific beam delivery time (BDT) prediction and delivery sequence model for standard, volumetric, and layer repainting delivery based on a cyclotron accelerator system. Approach . Test fields and clinical treatment plans’ log files were used to experimentally derive three main beam delivery parameters that impacted BDT: energy layer switching time (ELST), spot switching time, and spot drill time. This derived machine-specific model includes standard, volumetric, and layer repainting delivery sequences. A total of 103 clinical treatment fields were used to validate the model. Main results . The study found that ELST is not stochastic in this specific machine. Instead, it is actually the data transmission time or energy selection time, whichever takes longer. The validation showed that the accuracy of each component of the BDT matches well between machine log files and the model’s prediction. The average total BDT was about (−0.74 ± 3.33)% difference compared to the actual treatment log files, which is improved from the current commercial proton therapy system’s prediction (67.22%±26.19%). Significance . An accurate BDT prediction and delivery sequence model was established for an cyclotron-based proton therapy system IBA ProteusPLUS ® . Most institutions could adopt this method to build a machine-specific model for their own proton system.
A comprehensive gene–environment interaction analysis in Ovarian Cancer using genome‐wide significant common variants
As a follow‐up to genome‐wide association analysis of common variants associated with ovarian carcinoma (cancer), our study considers seven well‐known ovarian cancer risk factors and their interactions with 28 genome‐wide significant common genetic variants. The interaction analyses were based on data from 9971 ovarian cancer cases and 15,566 controls from 17 case–control studies. Likelihood ratio and Wald tests for multiplicative interaction and for relative excess risk due to additive interaction were used. The top multiplicative interaction was noted between oral contraceptive pill (OCP) use (ever vs. never) and rs13255292 (p value = 3.48 × 10−4). Among women with the TT genotype for this variant, the odds ratio for OCP use was 0.53 (95% CI = 0.46–0.60) compared to 0.71 (95%CI = 0.66–0.77) for women with the CC genotype. When stratified by duration of OCP use, women with 1–5 years of OCP use exhibited differential protective benefit across genotypes. However, no interaction on either the multiplicative or additive scale was found to be statistically significant after multiple testing correction. The results suggest that OCP use may offer increased benefit for women who are carriers of the T allele in rs13255292. On the other hand, for women carrying the C allele in this variant, longer (5+ years) use of OCP may reduce the impact of carrying the risk allele of this SNP. Replication of this finding is needed. The study presents a comprehensive analytic framework for conducting gene–environment analysis in ovarian cancer.
The Reciprocity between Radiotherapy and Cancer Immunotherapy
Abstract The clinical success of immune checkpoint inhibitors in treating metastatic and refractory cancers has generated significant interest in investigating their role in treating locally advanced diseases, thus requiring them to be combined with standard treatments in the hope of producing synergistic antitumor responses. Radiotherapy, in particular, has long been hypothesized to have actions complementary to those of immune checkpoint blockade, and a growing body of evidence indicates that cancer immunotherapy may also have radiosensitizing effects, which would provide unique benefit for locoregional treatments. Recent studies have demonstrated that when immune cells are activated by immunotherapeutics, they can reprogram the tumor microenvironment in ways that may potentially increase the radiosensitivity of the tumor. In this review, we highlight the evidence that supports reciprocal interactions between cancer immunotherapy and radiotherapy, where in addition to the traditional notion that radiation serves to enhance the activation of antitumor immunity, an alternative scenario also exists in which T-cell activation by cancer immunotherapy may sensitize tumors to radiation treatment through mechanisms that include normalization of the tumor vasculature and tissue hypoxia. We describe the empirical observations from preclinical models that support such effects and discuss their implications for future research and trial design.
Robust Tests for Additive Gene-Environment Interaction in Case-Control Studies Using Gene-Environment Independence
Abstract Rationale Despite shared environmental exposures, idiopathic pulmonary fibrosis (IPF) and chronic obstructive pulmonary disease are usually studied in isolation, and the presence of shared molecular mechanisms is unknown. Objectives We applied an integrative genomic approach to identify convergent transcriptomic pathways in emphysema and IPF. Methods We defined the transcriptional repertoire of chronic obstructive pulmonary disease, IPF, or normal histology lungs using RNA-seq (n = 87). Measurements and Main Results Genes increased in both emphysema and IPF relative to control were enriched for the p53/hypoxia pathway, a finding confirmed in an independent cohort using both gene expression arrays and the nCounter Analysis System (n = 193). Immunohistochemistry confirmed overexpression of HIF1A, MDM2, and NFKBIB members of this pathway in tissues from patients with emphysema or IPF. Using reads aligned across splice junctions, we determined that alternative splicing of p53/hypoxia pathway–associated molecules NUMB and PDGFA occurred more frequently in IPF or emphysema compared with control and validated these findings by quantitative polymerase chain reaction and the nCounter Analysis System on an independent sample set (n = 193). Finally, by integrating parallel microRNA and mRNA-Seq data on the same samples, we identified MIR96 as a key novel regulatory hub in the p53/hypoxia gene-expression network and confirmed that modulation of MIR96 in vitro recapitulates the disease-associated gene-expression network. Conclusions Our results suggest convergent transcriptional regulatory hubs in diseases as varied phenotypically as chronic obstructive pulmonary disease and IPF and suggest that these hubs may represent shared key responses of the lung to environmental stresses.