Citations

Clear

4 citation(s) found for "Lee, Hyoung-Ki".

Artificial intelligence–derived electrocardiographic aging and risk of atrial fibrillation: a multi-national study
Cho, Seunghoon , Eom, Sujeong , Kim, Daehoon , Kim, Tae‐Hoon , Uhm, Jae‐Sun , Pak, Hui‐Nam , Lee, Moon‐Hyoung , Yang, Pil‐Sung , Lee, Eunjung , Attia, Zachi I. , Friedman, Paul A. , You, Seng Chan , Yu, Hee Tae , Joung, Boyoung , Attia, Zachi I , Friedman, Paul A , Joung, Boyoung

Mayo Clinic

European Heart Journal | December 3, 2024 | Volume: 46 | Issue: 9 | Pages: 839-852

10.1093/eurheartj/ehae790 | PMID 39626169 Get It

Abstract Background and Aims Artificial intelligence (AI) algorithms in 12-lead electrocardiogram (ECG) provides promising age prediction methods. This study investigated whether the discrepancy between ECG-derived AI-predicted age (AI-ECG age) and chronological age, termed electrocardiographic aging (ECG aging), is associated with atrial fibrillation (AF) risk. Methods An AI-ECG age prediction model was developed using a large-scale dataset (1 533 042 ECGs from 689 639 participants) and validated with six independent and multi-national datasets (737 133 ECGs from 330 794 participants). The AI-ECG age gap was calculated across two South Korean cohorts [mean (standard deviation) follow-up: 4.1 (4.3) years for 111 483 participants and 6.1 (3.8) years for 37 517 participants], one UK cohort [3.0 (1.6) years; 40 973 participants], and one US cohort [12.9 (8.6) years; 90 639 participants]. Participants were classified into two groups: normal group (age gap < 7 years) and ECG-aged group (age gap ≥ 7 years). The predictive capability of ECG aging for new- and early-onset AF risk was assessed. Results The mean AI-ECG ages were 51.9 (16.2), 47.4 (12.5), 68.4 (7.8), and 56.7 (14.6) years with age gaps of .0 (6.8), −.1 (6.0), 4.7 (8.7), and −1.4 (8.9) years in the two South Korean, UK, and US cohorts, respectively. In the ECG-aged group, increased risks of new-onset AF were observed with hazard ratios (95% confidence intervals) of 2.50 (2.24–2.78), 1.89 (1.46–2.43), 1.90 (1.55–2.33), and 1.76 (1.67–1.86) in the two South Korean, UK, and US cohorts, respectively. For early-onset AF, odds ratios were 2.89 (2.47–3.37), 1.94 (1.39–2.70), 1.58 (1.06–2.35), and 1.79 (1.62–1.97) in these cohorts compared with the normal group. Conclusions The AI-derived ECG aging was associated with the risk of new- and early-onset AF, suggesting its potential utility to identify individuals for AF prevention across diverse populations.
Comparing in vivo wave-based elastography with ex vivo mechanical testing in porcine vessels
Capron, Charles , Lee, Hyoung-Ki , Tanner, Allison, Singh, Prabh G. , Kilari, Sreenivasulu , Liu, Gang , Roy, Tuhin, Guddati, Murthy N. , Misra, Sanjay, Urban, Matthew W.

Mayo Clinic

The Journal of the Acoustical Society of America | November 28, 2023 | Volume: 154 | Issue: 4_supplement | Pages: A318-A318

10.1121/10.0023659 Get It

Arterial stiffness predicts cardiovascular disease, the leading cause of death worldwide. Ultrasound elastography methods that measure wave velocity have promise for evaluating the stiffness of blood vessels in vivo. However, vessel geometry modulates wave velocity by inducing geometric dispersion. Here, we compare Young's modulus E estimates obtained using in vivo wave velocity measurements and techniques that either do or do not consider geometry to ex vivo reference E values from mechanical testing . An acoustic radiation force was applied to generate propagating waves in the right common carotid artery (N = 9) and external jugular vein (N = 10) of anesthetized pigs. Vessels were imaged with ultrafast ultrasound to measure wave motion. Group velocity cg was estimated from wave motion using a Radon transform. E was estimated from cg using a bulk media assumption which neglects geometry, as well as the Moens–Korteweg equation and a semi-analytical finite element model, which consider geometry. Pigs were euthanized and vessels were excised. Ring-shaped samples were extracted and tested in a uniaxial tension setup to obtain reference E values for comparison with E values obtained from wave-based techniques. Techniques considering geometry exhibited higher correlation with reference E values, underscoring the need to incorporate geometry for accurate vascular elastography assessments.
Comb Detection for Measuring Shear Wave Propagation
Lee, Hyoung-Ki , Holmes, Philip M. , Greenleaf, James F. , Urban, Matthew W. , Urban, Matthew W

Mayo Clinic

IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control | July 20, 2023 | Volume: 70 | Issue: 9 | Pages: 1135-1145

10.1109/tuffc.2023.3297394 | PMID 37471186 Get It

Measurement of wave propagation through a tube using dual transducers for elastography in arteries
Lee, Hyoung-Ki , Capron, Charles B, Liu, Hsiao‐Chuan , Roy, Tuhin , Guddati, Murthy N. , Greenleaf, James F., Urban, Matthew W. , Urban, Matthew W , Capron, Charles

Mayo Clinic

Physics in Medicine & Biology | October 20, 2022 | Volume: 67 | Issue: 22 | Pages: 225010

10.1088/1361-6560/ac9c3f | PMID 36265476 Get It

Abstract Objective. Measuring waves induced with acoustic radiation force (ARF) in arteries has been studied over the last decade. To date, it remains a challenge to quantitatively assess the local arterial biomechanical properties. The cylindrical shape and waveguide behavior of waves propagating in the arterial wall pose complexities to determining the mechanical properties of the artery. Approach . In this paper, an artery-mimicking tube in water is examined utilizing three-dimensional measurements. The cross-section of the tube is measured while a transducer is translated over 41 different positions along the length of the tube. Motion in the radial direction is calculated using two components of motion which are measured from the two orthogonal views of the cross-section. This enables more accurate estimation of motion along the circumference of tube. Main results . The results provide more information to categorize the motion in tube wall into two types of responses: a transient response and a steady state response. The transient response is caused by ARF application and the waves travel along the length of the tube for a relatively short period of time. This corresponds to the axial and circumferential propagating waves. The two circumferential waves travel along the circumference of tube in CW (clockwise) and CCW (counter-clockwise) direction and result in a standing wave. By using a directional filter, the two waves were successfully separated, and their propagation was more clearly visualized. As a steady state response, a circumferential mode is generated showing a symmetric motion (i.e. the proximal and distal walls move in the opposite direction) following the transient response. Significance. This study provides a more comprehensive understanding of the waves produced in an artery-mimicking tube with ARF application, which will provide opportunities for improving measurement of arterial mechanical properties.