0.05% Chlorhexidine gluconate is not associated with infection in antibiotic impregnated inflatable penile prosthesis surgery: results from a large multi-institutional collaborative
Abstract Background 0.05% Chlorhexidine gluconate (CHG) is now commonly used as an antiseptic irrigation for inflatable penile prosthesis (IPP) surgery. Limited in vitro data suggest compatibility of 0.05% CHG with antibiotic impregnated IPP devices; however, very little clinical research exists to guide use of 0.05% CHG in this population. Aim Assess the relationship of 0.05% CHG and antibiotic impregnated IPP infection in a large multi-institutional cohort. Methods We retrospectively reviewed a multi-institutional cohort of patients who underwent antibiotic impregnated IPP implantation. We identified cases using intraoperative 0.05% CHG and an equal number of consecutive control cases without 0.05% CHG use from each center for comparison. The primary outcome was IPP infection requiring explantation. Patient demographics and surgical variables were analyzed using chi-square tests and multivariable logistic regression to identify variables associated with infection. Outcomes The primary outcome was IPP infection requiring device explanation. Results Among 14 participating institutions, 761 cases using an antibiotic impregnated IPP were analyzed. Of these, 348 (45.7%) had 0.05% CHG used during the case. Median follow-up was 4 months (interquartile range 1-12) for the 0.05% CHG group and 8 months (interquartile range 2-21) for the control group. Intraoperative 0.05% CHG utilization was not associated with antibiotic impregnated IPP infection rate (1.9% vs. 2.0%, P = .9). On multivariable analysis, prior IPP infection (OR 6.32, 95% CI 1.32-30.2, P = .021) and prior priapism (OR 10.01, 95% CI 1.18-89.7, P = .039) were associated with increased infection risk. Clinical implications The use of 0.05% CHG irrigation with antibiotic impregnated IPPs was associated with similar infection rates compared to antibiotic irrigation. Strengths and limitations Limitations include the use of a historical comparator cohort which may introduce unknown confounders, practice variation between multiple sites, shorter follow-up in the 0.05% CHG cohort, and the low incidence of IPP infection which may limit statistical power despite a large sample. The major strengths include the large, multi-institutional cohort, and the use of consecutive patients to minimize selection bias. Conclusion 0.05% CHG utilization was not associated with infection rates in antibiotic impregnated IPPs.
Intraoperative 0.05% Chlorhexidine Gluconate Utilization Is Associated With an Increased Incidence of Infection in Hydrophilic Inflatable Penile Prosthesis Surgery: A Multi-Institutional Cohort Study
Purpose: To compare left-ventricular and aortic pressures obtained using fluid-filled and high-fidelity solid-state pressure catheters in subjects undergoing left heart catheterization. Methods: Twenty subjects scheduled for a left heart catheterization were enrolled and 18 subjects completed this IRB-approved study. During catheterization, left-ventricular (LV) and aortic (AO) pressures were obtained using a fluid-filled pressure catheter (standard-of-care) and a high-fidelity solid-state pressure catheter synchronously. The pressure tracings were analyzed by two independent readers to measure LV systolic (LVSP), LV minimum diastolic (LVMDP), LV end diastolic (LVEDP), AO systolic (AOSP), and AO diastolic (AODP) pressures. Derivatives of the pressure waveforms were computed to estimate the isovolumic contraction and relaxation rates (peak ± dp/dt). The measurements were made over multiple cardiac cycles and averaged results were used for comparisons using repeated measures analysis of variance, post-hoc tests with Bonferroni corrections and Bland-Altman plots. Results: A significant main effect of the pressure catheter was noted for LVSP, LVMDP and AOSP (p < 0.025). The LVSP and AOSP measured with fluid-filled pressure catheters were higher by 6.6 ± 6.9 mmHg and 4.6 ± 5.2 mmHg in comparison to the high-fidelity solid-state pressure catheter assessments. In contrast, the LVMDP measurements were 3.5 ± 5.7 mmHg lower than the solid-state pressure catheter measurements. When evaluating the differences between readers, the maximum difference was noted for LVEDP measurements (3.1 ± 2.4 mmHg; p ≤ 0.001). The differences in isovolumic contraction rate (66.4 ± 116.0 mmHg/s) and relaxation rate (60.5 ± 113.5 mmHg/s) were not significantly different between the two catheter systems after Bonferroni corrections for multiple comparisons (p > 0.06). Bland-Altman analysis revealed a bias ranging from 0.8 to 6.6 mmHg for all the pressure measurements. Conclusions: There are differences in LVSP, LVMDP, and AOSP measured using fluid-filled and high-fidelity solid-state pressure catheters. Clinicians should be aware that the fluid-filled catheters commonly overestimate the true systolic pressures in the left ventricle and aorta.
Executive Summary: Guidelines for Evaluating New Fever in Adult Patients in the ICU
RATIONALE: Fever is frequently an early indicator of infection and often requires rigorous diagnostic evaluation. OBJECTIVES: This is an update of the 2008 Infectious Diseases Society of America and Society (IDSA) and Society of Critical Care Medicine (SCCM) guideline for the evaluation of new-onset fever in adult ICU patients without severe immunocompromise, now using the Grading of Recommendations Assessment, Development, and Evaluation (GRADE) methodology. PANEL DESIGN: The SCCM and IDSA convened a taskforce to update the 2008 version of the guideline for the evaluation of new fever in critically ill adult patients, which included expert clinicians as well as methodologists from the Guidelines in Intensive Care, Development and Evaluation Group. The guidelines committee consisted of 12 experts in critical care, infectious diseases, clinical microbiology, organ transplantation, public health, clinical research, and health policy and administration. All task force members followed all conflict-of-interest procedures as documented in the American College of Critical Care Medicine/SCCM Standard Operating Procedures Manual and the IDSA. There was no industry input or funding to produce this guideline. METHODS: We conducted a systematic review for each population, intervention, comparison, and outcomes question to identify the best available evidence, statistically summarized the evidence, and then assessed the quality of evidence using the GRADE approach. We used the evidence-to-decision framework to formulate recommendations as strong or weak or as best-practice statements. RESULTS: The panel issued 12 recommendations and 9 best practice statements. The panel recommended using central temperature monitoring methods, including thermistors for pulmonary artery catheters, bladder catheters, or esophageal balloon thermistors when these devices are in place or accurate temperature measurements are critical for diagnosis and management. For patients without these devices in place, oral or rectal temperatures over other temperature measurement methods that are less reliable such as axillary or tympanic membrane temperatures, noninvasive temporal artery thermometers, or chemical dot thermometers were recommended. Imaging studies including ultrasonography were recommended in addition to microbiological evaluation using rapid diagnostic testing strategies. Biomarkers were recommended to assist in guiding the discontinuation of antimicrobial therapy. All recommendations issued were weak based on the quality of data. CONCLUSIONS: The guidelines panel was able to formulate several recommendations for the evaluation of new fever in a critically ill adult patient, acknowledging that most recommendations were based on weak evidence. This highlights the need for the rapid advancement of research in all aspects of this issue—including better noninvasive methods to measure core body temperature, the use of diagnostic imaging, advances in microbiology including molecular testing, and the use of biomarkers.
Abstract 12578: Development and Validation of a Scoring System For Predicting Technical Failure During Percutaneous Coronary Interventions of Chronic Total Occlusions: The Updated PROGRESS-CTO Score
Background: Predicting technical failure in chronic total occlusion (CTO) percutaneous coronary intervention (PCI) can assist with decision making and planning of the procedure. Methods: We analyzed 6,946 CTO PCIs performed between 2016 and June 2022 at 36 international centers in the Prospective Global Registry for the Study of Chronic Total Occlusion Intervention (PROGRESS-CTO) and created a score for risk of technical failure. Logistic regression prediction modeling was used to identify independently associated variables with technical failure and model were internally validated with bootstrapping. Results: Mean patient age was 64.0±10 years, 82% were men and technical success was 86%. The following variables were independently associated with technical failure and were included in the final model: age (odds ratio [OR]: 1.08, 95% Confidence Intervals [CI]: [1.00-1.15], p=0.039; age≥ 65 years; 1 point), CTO length (OR: 1.13, 95% CI [1.10, 1.17]; length≥ 20 mm; 1 point), moderate/severe calcification (OR: 1.35, 95% CI [1.17, 1.56]; 1 point), proximal cap ambiguity (OR: 2.25, 95% CI [1.95, 2.59]; 2 points), lack of interventional collaterals (OR: 1.60, 95% CI [1.39, 1.84]; 1 point), and lack of good distal landing zone (OR: 1.51, 95% CI [1.31, 1.75]; 1 point). The resulting score showed acceptable performance on receiver-operating characteristic (ROC) curve, AUC: 0.68 (95% CI [0.67-0.71]). Internal validation with bootstrapping of 1000 samples demonstrated a good agreement with the model, observed AUC: 0.68, (95% bias corrected CI [0.67, 0.70]). PROGRESS-CTO technical failure score and corresponding risk percentage and the percentage of patients in the respective risk group within the PROGRESS-CTO registry are represented in Figure 1. Conclusion: The updated PROGRESS CTO score may be useful for assessing the likelihood of technical failure success in CTO PCI.
2018 International Consensus Meeting on Musculoskeletal Infection: Research Priorities from the General Assembly Questions
ABSTRACT Musculoskeletal infections (MSKI) remain the bane of orthopedic surgery, and result in grievous illness and inordinate costs that threaten healthcare systems. As prevention, diagnosis, and treatment has remained largely unchanged over the last 50 years, a 2nd International Consensus Meeting on Musculoskeletal Infection (ICM 2018, https://icmphilly.com ) was completed. Questions pertaining to all areas of MSKI were extensively researched to prepare recommendations, which were discussed and voted on by the delegates using the Delphi methodology. The questions, including the General Assembly (GA) results, have been published ( GA questions ). However, as critical outcomes include: (i) incidence and cost data that substantiate the problems, and (ii) establishment of research priorities; an ICM 2018 research workgroup (RW) was assembled to accomplish these tasks. Here, we present the result of the RW consensus on the current and projected incidence of infection, and the costs per patient, for all orthopedic subspecialties, which range from 0.1% to 30%, and $17,000 to $150,000. The RW also identified the most important research questions. The Delphi methodology was utilized to initially derive four objective criteria to define a subset of the 164 GA questions that are high priority for future research. Thirty‐eight questions (23% of all GA questions) achieved the requisite > 70% agreement vote, and are highlighted in this Consensus article within six thematic categories: acute versus chronic infection, host immunity, antibiotics, diagnosis, research caveats, and modifiable factors. Finally, the RW emphasizes that without appropriate funding to address these high priority research questions, a 3rd ICM on MSKI to address similar issues at greater cost is inevitable.
Analysis of needle type for musculoskeletal lesion biopsy: results of a novel steerable needle
Background: Needle biopsy has proven to be a potentially adequate method for initial biopsy of many soft-tissue and bone lesions. To help optimize this procedure, this study sought to test the characteristics of several needles, including a steerable needle. Materials and Methods: Five needle types were tested, including a steerable needle. Animal muscle tissue was used for all testing. The following experiments were performed: (1) sample collection with different needle types, (2) histological analysis of needle track, (3) observation of steerable needle characteristics using CT-guidance. Results: Sample collection: The Menghini 21 g and Chiba 22 g needles were graded as excellent for ease of use and integrity of sample. Histologic evaluation showed good specimen preservation with all needle types. Histological analysis of needle track: tracks created by the Menghini 21 g and Spinal 20 g needles both showed no histologically detectable damage to surrounding tissue. Observation of steerable Menghini needle under CT-guidance: needle advanced easily through tissue, even when maximally curved. Small, large, and double curves were feasible to avoid obstacles and reach targets. There was no deflection or change in position of the needle tip when the stylet was removed. Needle withdrawal did not damage surrounding tissue. Conclusions: Compared to the other needles, the steerable needle was found to be durable and easy to use, allowing for precise navigation around vital structures yielding superior integrity of sample tissue.