Citations

Clear

6 citation(s) found for "Hsu, Jason".

VITREORETINAL OUTCOMES FOLLOWING SECONDARY INTRAOCULAR LENS IMPLANTATION WITH PARS PLANA VITRECTOMY
Kaufmann, Gabriel T. , Gupta, Omesh P. , Yu, Julia , Lee, Crystal Y., Achuck, Kathryn, Hsu, Jason C. , Regillo, Carl D. , Garg, Sunir J. , Klufas, Michael A. , Mehta, Sonia , Cohen, Michael N. , Yonekawa, Yoshihiro , Starr, Matthew R , Nguyen, Michael K. , Achuck, Kathryn, Hsu, Jason, Ho, Allen C. , Xu, David N. , Kuriyan, Ajay E. , Starr, Matthew R.

Mayo Clinic

Retina | May 7, 2024 | Volume: 44 | Issue: 8 | Pages: 1337-1343

10.1097/iae.0000000000004139 | PMID 39047127 Get It

Background: Retrospective cohort study of 561 adult patients undergoing secondary intraocular lens (IOL) implantation by vitreoretinal surgeons at a single institution from April 2015 to December 2020. Methods: Patient historical factors, intraoperative/postoperative complications, and outcomes of IOL type (anterior chamber IOL versus scleral sutured IOL versus scleral fixated IOL versus. sulcus) were assessed. Primary outcomes were rates of postoperative retinal tears and rhegmatogenous retinal detachment. Secondary outcomes were rates of intraoperative endolaser, intraoperative retinal tear, and further IOL surgery. Results: The incidence of intraoperative retinal tears was 7.3% and not significantly different between techniques. Rates of intraoperative endolaser use were 17.5% among all techniques and not significantly different between techniques. Rates of postoperative retinal tear were low (0%–2.7%). Rates of postoperative rhegmatogenous retinal detachment were not significantly different between techniques (anterior chamber IOL 9/198 [4.5%], SFIOL 1/54 [1.9%], scleral sutured IOL 14/274 [5.1%], sulcus 2/35 [5.7%], total 26/561 [4.6%], P = 0.79). Rates of repeat IOL surgery trended higher in sulcus lenses (anterior chamber IOL 5/198 [2.5%], SFIOL 4/54 [7.4%], scleral sutured IOL 16/274 [5.8%], sulcus 5/35 [14.3%], total 30/561 [5.3%], P = 0.12). Conclusion: Intraoperative endolaser use and intraoperative retinal tear are not uncommon in secondary IOL surgery and underscore the importance of careful vitreoretinal management among these patients.
RANDOMIZED TRIAL COMPARING MICROSERRATED VERSUS CONVENTIONAL INTERNAL LIMITING MEMBRANE FORCEPS FOR INTERNAL LIMITING MEMBRANE PEELING
Hinkle, John C. , Patel, Luv, Ammar, Michael J., Soares, Rebecca R. , Cohen, Michael N. , Hsu, Jason , Yonekawa, Yoshihiro , Regillo, Carl D. , Gupta, Omesh P. , Starr, Matthew R , Starr, Matthew R. , PATEL, SAMIR N. , Ho, Allen C.

Mayo Clinic

Retina | April 29, 2024 | Volume: 44 | Issue: 8 | Pages: 1323-1328

10.1097/iae.0000000000004138 | PMID 39047125 Get It

Purpose: To evaluate anatomic outcomes and surgeon response following the use of microserrated (Sharkskin, Alcon, Forth Worth, TX) internal limiting membrane (ILM) forceps compared with conventional (Grieshaber; Alcon) ILM forceps for peeling of the ILM. Methods: Patients were prospectively assigned in a 1:1 randomized fashion to undergo ILM peeling using microserrated forceps or conventional forceps. Rates of retinal hemorrhages, deep retinal grasps, ILM regrasping, time to ILM removal, and surgeon questionnaire comparing the use of microserrated and conventional ILM forceps were analyzed. Results: A total of 90 eyes of 90 patients were included in this study. The mean number of deep retinal grasps was higher in the conventional forceps group (1.51 ± 1.70 vs. 0.33 ± 0.56, respectively [P < 0.0001]). The mean number of failed ILM grasps was higher with conventional forceps (6.62 ± 3.51 vs. 5.18 ± 2.06 [P = 0.019]). Microserrated forceps provided more comfortability (lower number) in initiating the ILM flap (2.16 ± 0.85 vs. 1.56 ± 0.76, P < 0.001), comfortability in regrasping the ILM flap (2.51 ± 1.01 vs. 1.98 ± 0.89, P = 0.01), and comfortability in completing the ILM flap (2.42 ± 1.03 vs. 1.84 ± 1.02, P = 0.01). Conclusion: Surgeons utilizing the microserrated forceps experienced fewer deep retina grasps and fewer failed ILM grasps compared with conventional ILM forceps. The microserrated forceps was also a more favorable experience subjectively among the surgeons.
Risk Factors and Prophylactic Measures for Shoulder Periprosthetic Joint Infection After Primary Arthroplasty
Dhillon, Ekamjeet S. , Yao, Jie , Jurgensmeier, Kevin , Schiffman, Corey J. , Whitson, Anastasia J. , Matsen, Frederick A. , Hsu, Jason E. , Yao, Jie J , Jurgensmeier, Kevin

Mayo Clinic

JBJS Open Access | May 24, 2023 | Volume: 8 | Issue: 2 | Pages: No page available

10.2106/jbjs.oa.22.00019 Get It

Background: Our understanding of the risk factors for and effectiveness of prophylactic measures against shoulder periprosthetic joint infections (PJIs) continues to evolve. This study’s objective was to study patient characteristics, procedural characteristics, and various infection prophylactic measures and their effects on the risk of shoulder PJI after primary arthroplasty. Methods: Nine hundred and ninety-eight patients in a longitudinally maintained, single-institution shoulder arthroplasty database who had at least 2 years of clinical follow-up were retrospectively reviewed. Patient and procedural characteristics were collected. Perioperative variables, including the use of intraoperative antibiotics, topical antibiotics, antibiotic-containing irrigation solution, and a postoperative drain, were collected. Patients who developed shoulder PJI were compared with those without shoulder PJI to identify any association with patient or procedural characteristics. Results: Of the 998 patients, 20 (2.0%) met the criteria for shoulder PJI. Cutibacterium was identified as the causative organism in 19 (95%) of 20 culture-positive reoperations. On univariate analysis, patients in the PJI group were more likely to be younger (p < 0.001), to be male (p = 0.014), to have commercial insurance (p = 0.003), to use alcohol (p = 0.048), and to have had a ream-and-run or hemiarthroplasty procedure (p = 0.005). On multivariable analysis, older age was independently associated with a lower risk of PJI (odds ratio [OR] per year = 0.95; 95% confidence interval [CI], 0.91 to 0.99; p = 0.014). Reverse total shoulder arthroplasty (OR, 10.32; 95% CI, 0.92 to 116.33; p = 0.059) and hemiarthroplasty (OR, 8.59; 95% CI, 0.86.30 to 85.50; p = 0.067) trended toward a higher risk of PJI. Conclusions: Younger patients and patients undergoing procedures other than anatomic total shoulder arthroplasty are at higher risk for shoulder PJI. The majority of culture-positive reoperations were a result of Cutibacterium species. Level of Evidence: Therapeutic Level III . See Instructions for Authors for a complete description of levels of evidence.
Risk Factors for Stiffness Requiring Intervention After Ream-and-Run Arthroplasty
Schiffman, Corey J. , Jurgensmeier, Kevin , Yao, Jie , Wu, John , Whitson, Anastasia J. , Jackins, Sarah E. , Matsen, Frederick A. , Hsu, Jason E. , Yao, Jie J , Wu, John C , Jurgensmeier, Kevin

Mayo Clinic

JBJS Open Access | April 27, 2023 | Volume: 8 | Issue: 2 | Pages: No page available

10.2106/jbjs.oa.22.00104 | PMID 37123506 Get It

Background: Ream-and-run arthroplasty can improve pain and function in patients with glenohumeral arthritis while avoiding the complications and activity restrictions associated with a prosthetic glenoid component. However, stiffness is a known complication after ream-and-run arthroplasty and can lead to repeat procedures such as a manipulation under anesthesia (MUA) or open surgical revision. The objective of this study was to determine risk factors associated with repeat procedures indicated for postoperative stiffness after ream-and-run arthroplasty. Methods: We conducted a retrospective review of our shoulder arthroplasty database to identify patients who underwent ream-and-run arthroplasty and determined which patients underwent subsequent repeat procedures (MUA and/or open revision) indicated for postoperative stiffness. The minimum follow-up was 2 years. We collected baseline demographic information and preoperative and 2-year patient-reported outcome scores and analyzed preoperative radiographs. Univariate and multivariate analyses determined the factors significantly associated with repeat procedures to treat postoperative stiffness. Results: There were 340 patients who underwent ream-and-run arthroplasty. The mean Simple Shoulder Test (SST) scores for all patients improved from 5.0 ± 2.4 preoperatively to 10.2 ± 2.6 postoperatively (p < 0.001). Twenty-six patients (7.6%) underwent open revision for stiffness. An additional 35 patients (10.3%) underwent MUA. Univariate analysis found younger age (p = 0.001), female sex (p = 0.034), lower American Society of Anesthesiologists (ASA) class (p = 0.045), posterior decentering on preoperative radiographs (p = 0.010), and less passive forward elevation at the time of discharge after ream-and-run arthroplasty (p < 0.001) to be significant risk factors for repeat procedures. Multivariate analysis found younger age (p = 0.040), ASA class 1 compared with class 3 (p = 0.020), and less passive forward elevation at discharge (p < 0.001) to be independent risk factors for repeat procedures. Of the patients who underwent open revision for stiffness, 69.2% had multiple positive cultures for Cutibacterium. Conclusions: Younger age, ASA class 1 compared with class 3, and less passive forward elevation in the immediate postoperative period were independent risk factors for repeat procedures to treat postoperative stiffness after ream-and-run arthroplasty. Level of Evidence: Prognostic Level III . See Instructions for Authors for a complete description of levels of evidence.
REFRACTIVE ERROR CHANGE DURING TREATMENT OF DIABETIC MACULAR EDEMA
Salabati, Mirataollah , Mahmoudzadeh, Raziyeh , Zhang, Qiang , Sharpe, James , Hsu, Jason , Regillo, Carl D. , Kuriyan, Ajay E. , Starr, Matthew R. , Kuriyan, Ajay E , Ho, Allen C.

Mayo Clinic

Retina | October 21, 2022 | Volume: 42 | Issue: 11 | Pages: 2059-2065

10.1097/iae.0000000000003583 | PMID 36269800 Get It

Purpose: To evaluate the impact of anti–vascular endothelial growth factor therapy on the refractive error in eyes with diabetic macular edema. Methods: Post hoc analysis of Diabetic Retinopathy Clinical Research protocol T. Spherical equivalent (SE) was calculated for study and fellow eyes at baseline, 1-year, and 2-year visits. The SE change of the eyes with edema was compared with those with resolved edema. The correlation between refractive error changes and central subfield thickness was evaluated. Results: Among 543 study eyes, SE changed from −0.17 (2.04) D at baseline visit to −0.16 (2.14) D at 2 years giving a hyperopic shift of 0.04 (0.82) D (P = 0.022). Among fellow eyes, mean (SD) SE changed from −0.19 (2.1) D at baseline to −0.11 (2.1) D at 2 years, giving a hyperopic shift of 0.12 (0.84) D (P = 0.001). No significant difference in SE shift was found between eyes with and without edema at 2 years in phakic (0.12D and 0.08 D, P = 0.87) and pseudophakic eyes (−0.24D and −0.08D, P = 0.30). The SE shift was not correlated with central subfield thickness change at the end of the second year (r = 0.02, P = 0.62). Conclusion: Diabetic macular edema patients have minimal changes in refractive error. The correction of refractive error may be considered during treatment, regardless of the presence of edema.