Citations

Clear

16 citation(s) found for "Howell, Rebecca".

Unintentional Weight Loss Does Not Predict Poor Outcomes in Zenker Diverticulum
Allen, Jacqueline , Belafsky, Peter C., deSilva, Brad W. , Dhar, Shumon I. , Ekbom, Dale C. , Friedman, Aaron D. , Fritz, Mark A. , Gardner, Glendon M., Johnson, Christopher, Kasperbauer, Jan L. , Kim, Brandon , Kuhn, Maggie A. , Madden, Lyndsay L., Matrka, Laura , Piraka, Cyrus, Ramaswamy, Apoorva, Rosen, Clark A. , Sibley, Haley , Wright, Carter, Yang, Z. Mike, Young, VyVy N. , Postma, Gregory, Howell, Rebecca J. , Allen, Jacqui , Amin, Milan R , Bayan, Semirra L. , deSilva, Brad , Dhar, Shumon I , Ekbom, Dale , Fritz, Mark , Kasperbauer, Jan , Krekeler, Brittany N , Kuhn, Maggie , Ma, Yue , Matrka, Laura , Mayerhoff, Ross , Rosen, Clark , Sibley, Haley C , Tabangin, Meredith , Young, Vyvy , Howell, Rebecca , Schuman, Ari D. , Altaye, Mekibib , Belafsky, Peter C. , Gardner, Glendon M., Guardiani, Elizabeth , Madden, Lyndsay L. , Mayerhoff, Ross , Piraka, Cyrus , Ramaswamy, Apoorva Tewari , Tabangin, Meredith E. , Postma, Gregory

Mayo Clinic

The Laryngoscope | July 18, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1002/lary.70734 | PMID 42470432 Get It

ABSTRACT Objective Weight loss is frequently considered a cardinal presenting symptom for patients with Zenker diverticulum (ZD). We hypothesized that weight loss in patients with cricopharyngeal muscle dysfunction (CPMD), with or without diverticula, was associated with the length of symptoms and size of diverticulum. Methods Prospective, multicenter observational study of CPMD patients with and without diverticula reporting unintentional weight loss (+WL) or no weight loss (−WL) prior to enrollment in the Prospective Outcomes of Cricopharyngeal Hypertonicity (POuCH) database. Complications and symptom response using a patient reported outcome measure, the Eating Assessment Tool (EAT‐10), were compared. Results Of 427 patients, 101 (23.6%) were +WL. Median weight loss was 14 pounds (interquartile range [IQR] 10–25). +WL cohort had a mean age of 71.5 (standard deviation [SD] 11.5) vs. 67.9 in −WL (SD 11.6, p = 0.007). Mean preoperative EAT‐10 score was 24.7 in +WL (SD 9.7) and 14.8 in −WL (SD 8.8, p < 0.0001). Higher preoperative weight loss was associated with higher preoperative EAT‐10 ( p < 0.0001, Spearman's ρ = 0.43). Size of diverticulum was associated with WL ( p = 0.003), but weight loss was highest in both large diverticula and CP bars. Duration of symptoms was not associated with weight loss ( p = 0.30). Postoperative complications in +WL and −WL patients were similar ( p = 0.78). Conclusion Unintentional weight loss is common with ZD. Patients with worse dysphagia are more likely to have more weight loss. Weight loss does not increase with the size of the diverticulum or length of symptoms. Surgery has a similar safety profile with greater improvement in dysphagia in patients reporting weight loss. Level of Evidence 3.
AAPM Task Group Report 336: Quality assurance for 3D printing in medical imaging and radiation therapy applications
Leng, Shuai, Craft, D. , Angel, Erin , Howell, Rebecca M., Jesseph, F., Kiarashi, Nooshin, Lewis, John H., Lo, Joseph, Markovic, Alex, McGee, Kiaran P. , Prah, D.E. , Rasmussen, Karl H., Rong, Yi, Schaefer, Kyle E., Solomon, Justin B., Leng, Shuai , Howell, Rebecca M. , Ionita, Ciprian N. , Lewis, John Henry , Lo, Joseph Yuan-Chieh , Solomon, Justin , Wake, Nicole

Mayo Clinic

Medical Physics | April 29, 2026 | Volume: 53 | Issue: 5 | Pages: No page available

10.1002/mp.70446 Get It

Abstract Additive manufacturing (AM), commonly referred to as 3D printing, has been broadly used in the field of medical imaging and radiotherapy. In medical imaging applications, patient‐specific anatomic models have been used to aid in preoperative planning, patient communication, imaging technique assessment and optimization, and medical education. Within the field of radiation therapy, 3D printing finds significance in fabricating patient‐specific immobilization devices, custom bolus devices, anthropomorphic phantoms, brachytherapy devices, and electron therapy devices. Consistent with standard medical physics practices there is a need to establish quality assurance and quality control (QA/QC) protocols, tolerances, and testing frequencies. The diversity of 3D printing technologies and products poses challenges for medical adoption and thus requires guidelines in workflow standardization and establishment of testing procedures. This report is centered around providing comprehensive vendor‐neutral implementation guidelines and recommendations for QC and QA processes. The scope of this report encompasses diverse requirements within medical imaging and radiation therapy settings, serving both clinical and research purposes. Brief overview of 3D printing technology, common materials, and potential clinical applications is provided. QA team, infrastructure, measurement techniques and challenges are discussed. QA processes for each step in 3D printing are discussed in great detail and baseline and action limits are recommended. This report also touched on regulatory considerations. Key recommendations are summarized at the end of the report.
Characterization of LiF TLD‐100 in carbon ion beams for remote audits
Taylor, Paige A. , Mirandola, Alfredo , Ciocca, Mario , Hartzell, Shannon , Magro, Giuseppe , Alvarez, P , Peeler, C , Howell, Rebecca M. , Taylor, Paige , Peterson, Christine B. , Koay, Eugene J. , Kry, Stephen F.

Mayo Clinic

Medical Physics | December 24, 2024 | Volume: 52 | Issue: 3 | Pages: 1858-1866

10.1002/mp.17605 | PMID 39718203 Get It

Abstract Background A passive dosimeter framework for the measurement of dose in carbon ion beams has yet to be characterized or implemented for regular use. Purpose This work determined the dose calculation correction factors for absorbed dose in thermoluminescent dosimeters (TLDs) in a therapeutic carbon ion beam. TLD could be a useful tool for remote audits, particularly in the context of clinical trials as new protocols are developed for carbon ion radiotherapy. Methods TLD‐100 were irradiated in a carbon ion beam at the Centro Nazionale di Adroterapia Oncologica (CNAO) in Pavia, Italy. The dose correction factors for linearity, fading, and beam quality were characterized. Fading was characterized from 5 to 100 days post‐irradiation. For linearity, the TLDs were irradiated to absorbed doses ranging from 1 to 15 Gy in both the entrance of a high‐energy pristine carbon ion peak and the center of a 2 cm spread‐out Bragg peak. For beam quality, the TLD was irradiated to the same absorbed dose (3 Gy) in several pristine carbon ion Bragg peaks, as well as in several spread‐out Bragg peaks. Each correction factor was calculated and compared to photon correction factors. The correction factors were also compared between high and low dose‐averaged linear energy transfer (LET D ) in the carbon ion beams. The absorbed dose was compared between ion chamber and TLD‐100 in the several tissue substitute phantom materials, applying the carbon ion TLD correction factors. Results There was no statistically significant difference in the TLD fading correction factor between photons, low LET D carbon ion beams, or high LET D carbon ion beams. The TLD linearity correction factor did differ between photons, low LET D carbon ions, and high LET D carbon ions. The beam quality correction factor was large and changed linearly with LET D . The overall uncertainty of the carbon ion absorbed dose calculation was 3.9% at the one‐sigma level, driven largely by a 3.5% uncertainty in the beam quality correction. TLD measurements were within 1.2% of ion chamber measurements in the phantom material for polyethylene, solid water (Gammex and Sun Nuclear), acrylic, blue water, and techtron HPV. TLD measurements in balsa wood were within 3.0% and cork was 6.6% low compared to ion chamber. Conclusion TLD‐100 can be used for passive dosimetry in a therapeutic carbon ion beam. Importantly, the linearity and beam quality correction factors are both different from photon therapy, and dependent on LET D of the carbon ion beam. This opens the possibility of TLD use for carbon ion output audits, phantom audits, and in vivo dose measurements, but may be subject to more complicated management and slightly larger uncertainties than are achieved in photon beams.
Surgical Nonresponders in Zenker Diverticulum and Lower Esophageal Pathology (POUCH Collaborative)
Brown, Johnathan , McCoy, Nicole, Allen, Jacqui , Altaye, Mekibib , Bayan, Semirra L. , Belafsky, Peter C. , deSilva, Brad W. , Ekbom, Dale C. , Friedman, Aaron D. , Fritz, Mark A. , Johnson, Christopher , Kasperbauer, Jan L. , Kim, Brandon , Kuhn, Maggie A. , Madden, Lyndsay L. , Matrka, Laura , Piraka, Cyrus , Rosen, Clark A. , Wahab, Shaun A. , Wilson, Keith , Wright, Carter , Young, VyVy N. , Postma, Gregory N. , Howell, Rebecca J. , Bayan, Semirra, deSilva, Brad , Ekbom, Dale , Fritz, Mark , Giliberto, John Paul , Kasperbauer, Jan , Krekeler, Brittany N , Kuhn, Maggie , Ma, Yue , Matrka, Laura , Mayerhoff, Ross , Rosen, Clark , Tabangin, Meredith , Young, Vyvy , Howell, Rebecca , Bayan, Semirra , Amin, Milan R , Dion, Gregory R. , Giliberto, John Paul , Guardiani, Elizabeth , Kwak, Paul E. , Mayerhoff, Ross , Tabangin, Meredith E. , Wilson, Keith, Wright, Carter

Mayo Clinic

The Laryngoscope | July 9, 2024 | Volume: 134 | Issue: 12 | Pages: 4897-4902

10.1002/lary.31619 | PMID 38979706 Get It

ObjectiveTo identify characteristics of patients who have poor improvement in symptoms following surgical management of Zenker Diverticulum (ZD).MethodsProspective, multicenter cohort study of all individuals enrolled in the Prospective OUtcomes of Cricopharyngeus Hypertonicity (POUCH) Collaborative who underwent surgical repair of ZD between August 2017 and January 2024. Patient demographics, esophagrams, and the 10‐item Eating Assessment Tool (EAT‐10) pre‐ and post‐procedure were obtained from a REDCap database. t‐tests, Wilcoxon rank sum tests, Chi‐square or Fisher's exact tests were used to compare the characteristics. Patients with <50% improvement in their EAT‐10 scores were deemed surgical nonresponders (SNRs). Those with ≥50% improvement in their EAT‐10 scores were deemed surgical responders (SRs).ResultsA total of 184 patients were prospectively followed after undergoing either open or endoscopic surgical management. Twenty‐two patients (12%) were deemed SNRs. Preoperative presence of a hiatal hernia was statistically significant characteristic between the SNRs (63.6%) and SRs (32.1%) (p = 0.004). Size of the ZD and history of previous ZD surgery was not a significant characteristic. The length of stay and complication rate were not statistically different between the groups.ConclusionCoexistent esophageal pathology may lead to poor symptomatic improvement following ZD surgery. Preoperative workup of other esophageal disorders is recommended to detect likely SNRs. For SNRs, further esophageal workup may be necessary to evaluate for other esophageal causes related to poor symptomatic improvement following ZD surgery.Level of Evidence3 Laryngoscope, 134:4897–4902, 2024
OSLD nanoDot characterization for carbon radiotherapy dosimetry
Taylor, Paige A. , Hartzell, Shannon , Ciocca, Mario , Magro, Giuseppe , Alvarez, P , Peeler, C , Howell, Rebecca M. , Taylor, Paige , Mirandola, Alfredo , Peterson, Christine B. , Koay, Eugene J. , Kry, Stephen F.

Mayo Clinic

Physics in Medicine & Biology | April 25, 2024 | Volume: 69 | Issue: 11 | Pages: 115001

10.1088/1361-6560/ad43ac | PMID 38663410 Get It

Abstract Objective . This study characterized optically-stimulated luminescent dosimeter (OSLD) nanoDots for use in a therapeutic carbon beam using the Imaging and Radiation Oncology Core (IROC) framework for remote output verification. Approach . The absorbed dose correction factors for OSLD (fading, linearity, beam quality, angularity, and depletion), as defined by AAPM TG 191, were characterized for carbon beams. For the various correction factors, the effect of linear energy transfer (LET) was examined by characterizing in both a low and high LET setting. Main results . Fading was not statistically different between reference photons and carbon, nor between low and high LET beams; thus, the standard IROC-defined exponential function could be used to characterize fading. Dose linearity was characterized with a linear fit; while low and high LET carbon linearity was different, these differences were small and could be rolled into the uncertainty budget if using a single linearity correction. A linear fit between beam quality and dose-averaged LET was determined. The OSLD response at various angles of incidence was not statistically different, thus a correction factor need not be applied. There was a difference in depletion between low and high LET irradiations in a primary carbon beam, but this difference was small over the standard five readings. The largest uncertainty associated with the use of OSLDs in carbon was because of the k Q correction factor, with an uncertainty of 6.0%. The overall uncertainty budget was 6.3% for standard irradiation conditions. Significance . OSLD nanoDot response was characterized in a therapeutic carbon beam. The uncertainty was larger than for traditional photon applications. These findings enable the use of OSLDs for carbon absorbed dose measurements, but with less accuracy than conventional OSLD audit programs.
Technical note: Radiological clinical equivalence for phantom materials in carbon ion therapy
Taylor, Paige A. , Ciocca, Mario , Hartzell, Shannon , Vai, Alessandro , Alvarez, P , Howell, Rebecca M. , Peeler, C , Taylor, Paige , Mirandola, Alfredo , Koay, Eugene J. , Peterson, Christine B. , Kry, Stephen F.

Mayo Clinic

Medical Physics | April 10, 2024 | Volume: 51 | Issue: 7 | Pages: 5154-5158

10.1002/mp.17056 | PMID 38598230 Get It

AbstractPurposeAs carbon ion radiotherapy increases in use, there are limited phantom materials for heterogeneous or anthropomorphic phantom measurements. This work characterized the radiological clinical equivalence of several phantom materials in a therapeutic carbon ion beam.MethodsEight materials were tested for radiological material‐equivalence in a carbon ion beam. The materials were computed tomography (CT)‐scanned to obtain Hounsfield unit (HU) values, then irradiated in a monoenergetic carbon ion beam to determine relative linear stopping power (RLSP). The corresponding HU and RLSP for each phantom material were compared to clinical carbon ion calibration curves. For absorbed dose comparison, ion chamber measurements were made in the center of a carbon ion spread‐out Bragg peak (SOBP) in water and in the phantom material, evaluating whether the material perturbed the absorbed dose measurement beyond what was predicted by the HU‐RLSP relationship.ResultsPolyethylene, solid water (Gammex and Sun Nuclear), Blue Water (Standard Imaging), and Techtron HPV had measured RLSP values that agreed within ±4.2% of RLSP values predicted by the clinical calibration curve. Measured RLSP for acrylic was 7.2% different from predicted. The agreement for balsa wood and cork varied between samples. Ion chamber measurements in the phantom materials were within 0.1% of ion chamber measurements in water for most materials (solid water, Blue Water, polyethylene, and acrylic), and within 1.9% for the rest of the materials (balsa wood, cork, and Techtron HPV).ConclusionsSeveral phantom materials (Blue Water, polyethylene, solid water [Gammex and Sun Nuclear], and Techtron HPV) are suitable for heterogeneous phantom measurements for carbon ion therapy. Low density materials should be carefully characterized due to inconsistencies between samples.
Postoperative Care of Zenker Diverticula: Contemporary Perspective from the Prospective OUtcomes Cricopharyngeaus Hypertonicity (POUCH) Collaborative
McKeon, Mallory , McCoy, Nicole, Johnson, Christopher , Allen, Jacqui , Altaye, Mekibib , Bayan, Semirra L. , Belafsky, Peter C. , deSilva, Brad W. , Dion, Gregory R. , Ekbom, Dale C. , Friedman, Aaron D. , Fritz, Mark A. , Kasperbauer, Jan L. , Kim, Brandon , Kuhn, Maggie A. , Madden, Lyndsay L. , Matrka, Laura , Mayerhoff, Ross , Piraka, Cyrus , Rosen, Clark A. , Wahab, Shaun A. , Wilson, Keith , Wright, Carter , Young, VyVy N. , Postma, Gregory N. , Howell, Rebecca J. , Bayan, Semirra, Belafsky, Peter , deSilva, Brad , Dion, Greg , Ekbom, Dale , Friedman, Aaron D , Fritz, Mark , Giliberto, John Paul , Kasperbauer, Jan , Krekeler, Brittany N , Kuhn, Maggie , Ma, Yue , Matrka, Laura , Mayerhoff, Ross , Rosen, Clark , Tabangin, Meredith , Young, Vyvy , Howell, Rebecca , Bayan, Semirra , Amin, Milan R , Giliberto, John Paul , Guardiani, Elizabeth , Kwak, Paul E. , Tabangin, Meredith E. , Wilson, Keith, Wright, Carter

Mayo Clinic

The Laryngoscope | December 26, 2023 | Volume: 134 | Issue: 6 | Pages: 2678-2683

10.1002/lary.31226 | PMID 38146791 Get It

Objectives The aim of the study was to identify trends in postoperative management of persons undergoing surgery for Zenker diverticula (ZD) by evaluating length of stay (LOS), diet on discharge, and imaging with or without surgical complication. Methods Prospectively enrolled adult patients with cricopharyngeal muscle dysfunction with diverticula undergoing surgery from August 1, 2017 to February 1, 2023 were included. Data were extracted from a multi‐institutional REDCap database, summarizing means, medians, percentages, and frequencies. Fisher's exact or chi squared analyses were utilized, as appropriate, to compare subsets of data. Descriptive analysis assessed differences in clinical course and the relationship to postoperative management. Results There were 298 patients with a mean (standard deviation) age of 71.8 (11.2) years and 60% male. Endoscopic surgery was performed in 79.5% (237/298) of patients versus 20.5% (61/298) open surgery. Sixty patients (20.1%) received postoperative imaging, with four leaks identified. Complications were identified in 9.4% of cases ( n = 29 complications in 28 patients), more commonly in open surgery. Most (81.2%) patients were discharged within 23 h. About half of patients (49%) were discharged from the hospital on a pureed/liquid diet; 36% had been advanced to a soft diet. In patients without complications, LOS was significantly longer following open cases ( p = 0.002); postoperative diet was not different between open and endoscopic ( p = 0.26). Conclusions Overall, most patients are discharged within 23 h without imaging. However, LOS was affected by surgical approach. Postoperative complications are different in endoscopic versus open surgery. Complications with either approach were associated with prolonged LOS, need for imaging, and diet restriction. Level of Evidence Level III Laryngoscope , 134:2678–2683, 2024
Cardiac Substructure Radiation Dose and Risk of Late Cardiac Disease in Survivors of Childhood Cancer: A Report From the Childhood Cancer Survivor Study
Bates, James E. , Shrestha, Suman , Liu, Qi , Smith, Susan A. , Mulrooney, Daniel A. , Leisenring, Wendy M. , Robison, Leslie L. , Chow, Eric J. , Oeffinger, Kevin C. , Armstrong, Gregory T. , Howell, Rebecca M. , Leisenring, Wendy , Gibson, Todd , Robison, Leslie L , Chow, Eric J , Oeffinger, Kevin C , Constine, Louis S , Hoppe, Bradford S , Lee, Choonsik , Yasui, Yutaka , Mulrooney, Daniel A , Gibson, Todd M. , Hoppe, Bradford S.

Mayo Clinic

Journal of Clinical Oncology | June 12, 2023 | Volume: 41 | Issue: 22 | Pages: 3826-3838

10.1200/jco.22.02320 | PMID 37307512 Get It

PURPOSE Radiation-associated cardiac disease is a major cause of morbidity/mortality among childhood cancer survivors. Radiation dose-response relationships for cardiac substructures and cardiac diseases remain unestablished. METHODS Using the 25,481 5-year survivors of childhood cancer treated from 1970 to 1999 in the Childhood Cancer Survivor Study, we evaluated coronary artery disease (CAD), heart failure (HF), valvular disease (VD), and arrhythmia. We reconstructed radiation doses for each survivor to the coronary arteries, chambers, valves, and whole heart. Excess relative rate (ERR) models and piecewise exponential models evaluated dose-response relationships. RESULTS The cumulative incidence 35 years from diagnosis was 3.9% (95% CI, 3.4 to 4.3) for CAD, 3.8% (95% CI, 3.4 to 4.2) for HF, 1.2% (95% CI, 1.0 to 1.5) for VD, and 1.4% (95% CI, 1.1 to 1.6) for arrhythmia. A total of 12,288 survivors (48.2%) were exposed to radiotherapy. Quadratic ERR models improved fit compared with linear ERR models for the dose-response relationship between mean whole heart and CAD, HF, and arrhythmia, suggesting a potential threshold dose; however, such departure from linearity was not observed for most cardiac substructure end point dose-response relationships. Mean doses of 5-9.9 Gy to the whole heart did not increase the risk of any cardiac diseases. Mean doses of 5-9.9 Gy to the right coronary artery (rate ratio [RR], 2.6 [95% CI, 1.6 to 4.1]) and left ventricle (RR, 2.2 [95% CI, 1.3 to 3.7]) increased risk of CAD, and to the tricuspid valve (RR, 5.5 [95% CI, 2.0 to 15.1]) and right ventricle (RR, 8.4 [95% CI, 3.7 to 19.0]) increased risk of VD. CONCLUSION Among children with cancer, there may be no threshold dose below which radiation to the cardiac substructures does not increase the risk of cardiac diseases. This emphasizes their importance in modern treatment planning.
Surgical Outcomes in Zenker Diverticula: A Multicenter, Prospective, Longitudinal Study
Howell, Rebecca J. , Johnson, Christopher , Allen, Jacqui , Altaye, Mekibib , Bayan, Semirra L. , Belafsky, Peter C. , Cervenka, Brian , deSilva, Brad W. , Dion, Gregory R. , Ekbom, Dale C. , Friedman, Aaron D. , Fritz, Mark A. , Kasperbauer, Jan L. , Kim, Brandon , Kuhn, Maggie A. , Madden, Lyndsay L. , Matrka, Laura , Mayerhoff, Ross , McKeon, Mallory , Piraka, Cyrus , Rosen, Clark A. , Wahab, Shaun A. , Wilson, Keith , Wright, Carter , Young, VyVy N. , Postma, Gregory N. , Collaborative, Prospective OUtcomes of Cricopharyngeal Hypertonicity (POUCH), Howell, Rebecca , Bayan, Semirra, Belafsky, Peter , deSilva, Brad , Dion, Greg , Ekbom, Dale , Friedman, Aaron D , Giliberto, John Paul , Kasperbauer, Jan , Krekeler, Brittany N , Kuhn, Maggie , Ma, Yue , Matrka, Laura , Mayerhoff, Ross , Rosen, Clark , Tabangin, Meredith , Young, Vyvy , Bayan, Semirra , Amin, Milan R , Giliberto, John Paul , Guardiani, Elizabeth , Kwak, Paul E. , Tabangin, Meredith E. , Wilson, Keith, Wright, Carter, Collaborative, Prospective OUtcomes of Cricopharyngeal Hypertonicity (POUCH)

Mayo Clinic

The Laryngoscope | May 16, 2023 | Volume: 134 | Issue: 1 | Pages: 97-102

10.1002/lary.30753 | PMID 37191092 Get It

ObjectiveTo compare improvement in patient‐reported outcomes (PROM) in persons undergoing endoscopic and open surgical management of Zenker diverticula (ZD).MethodologyProspective, multicenter cohort study of all individuals enrolled in the Prospective OUtcomes of Cricopharyngeus Hypertonicity (POUCH) Collaborative who underwent surgery for ZD. Patient survey, radiography reports, and the 10‐item Eating Assessment Tool (EAT‐10) pre‐ and post‐procedure were abstracted from a REDCap database, which summarized means, medians, percentages, and frequencies of. Outcome based on operative intervention (endoscopic vs. open) was compared using t‐test, Wilcoxon rank sum test or chi‐square test, as appropriate.ResultsOne hundred and forty‐seven persons were prospectively followed. The mean age (SD) of the cohort was 68.7 (11.0). Overall, 66% of patients reported 100% improvement in EAT‐10; 81% of patients had greater than 75% improvement; and 88% had greater than 50% improvement. Endoscopic was used for n = 109 patients, and open surgical intervention was used for n = 38. The median [interquartile range, IQR] EAT‐10 percent improvement for endoscopic treatment was 93.3% [72, 100], and open was 100% [92.3, 100] (p = 0.05). The incidence of intraoperative complications was 3.7% for endoscopic and 7.9% for open surgical management. The median [IQR] in follow‐up was 86 and 97.5 days, respectively.ConclusionBoth endoscopic and open surgical management of ZD provide significant improvement in patient‐reported outcomes. The data suggest that open diverticulectomy may provide a modest advantage in symptomatic improvement compared to endoscopic management. The data suggest that the postoperative complication rate is higher in the open surgical group.Level of Evidence3 Laryngoscope, 134:97–102, 2024
Comparative Treatment Outcomes for Idiopathic Subglottic Stenosis: 5‐Year Update
Tierney, William S. , Huang, Li‐Ching , Chen, Sheau‐Chiann , Berry, Lynn D., Anderson, Catherine , Benninger, Michael S. , Blumin, Joel H. , Bryson, Paul C. , Castellanos, Paul F., Cohen, Seth M. , Crawley, Brianna K. , Dailey, Seth H. , Daniero, James J. , Alarcón, Alessandro de , Donovan, Donald T., Edell, Eric S. , Ekbom, Dale C. , Fink, Daniel S. , Franco, Ramon A. , Garrett, Catherine Gaelyn, Hoffman, Henry T. , Hogikyan, Norman D. , Howell, Rebecca J. , Johns, Michael M. , Kasperbauer, Jan L. , Khosla, Sid , Kinnard, Cheryl, Kupfer, Robbi A. , Langerman, Alexander , Lentz, Robert J. , Lorenz, Robert R. , Makani, Samir, Maldonado, Fabien , Matrka, Laura , McWhorter, Andrew J., Meratı, Albert L., Mori, Matthew , O’Dell, Karla , Postma, Gregory N. , Reder, Lindsay , Richardson, Brent E. , Rickman, Otis B. , Rosen, Clark A. , Rutter, Michael J. , Sandhu, Guri, Schindler, Joshua S. , Schneider, Glenn Todd , Shah, Rupali N., Sikora, Andrew G. , Sinard, Robert J. , Smith, Marshall E. , Smith, Libby J. , Soliman, Ahmed M. S. , Sveinsdóttir, Sigríður, Veivers, David , Verma, Sunil P., Weissbrod, Philip A. , Wootten, Christopher T. , Shyr, Yu , Francis, David O. , Daele, Douglas J. Van , Chen, Sheau-Chiann , Cohen, Seth M , Hoffman, Henry T , Weissbrod, Philip A , Amin, Milan R , Bock, Jonathan M. , Clary, Matthew S. , Guardiani, Elizabeth , Hillel, Alexander T. , Lott, David G. , Netterville, James L. , Ongkasuwan, Julina , Rohde, Sarah L. , Rohlfing, Matthew L. , Weinberger, Paul , Gelbard, Alexander

Mayo Clinic

Otolaryngology–Head and Neck Surgery | January 19, 2023 | Volume: 168 | Issue: 6 | Pages: 1570-1575

10.1002/ohn.190 | PMID 36939627 Get It

Abstract The North American Airway Collaborative (NoAAC) previously published a 3‐year multi‐institutional prospective cohort study showing variation in treatment effectiveness between 3 primary surgical techniques for idiopathic subglottic stenosis (iSGS). In this report, we update these findings to include 5 years of data evaluating treatment effectiveness. Patients in the NoAAC cohort were re‐enrolled for 2 additional years and followed using the prespecified published protocol. Consistent with prior data, prospective observation of 487 iSGS patients for 5 years showed treatment effectiveness differed by modality. Cricotracheal resection maintained the lowest rate of recurrent operation (5%), followed by endoscopic resection with adjuvant medical therapy (30%) and endoscopic dilation (50%). These data support the initial observations and continue to provide value to providers and patients navigating longitudinal decision‐making. Level of evidence: 2—prospective cohort study.