Citations

Clear

22 citation(s) found for "Hassan, Cesare".

Environmental impact of computer-aided diagnosis in colonoscopy: a carbon footprint assessment of a prospective study cohort
Olabintan, Olaolu , Halvorsen, Natalie , Baddeley, Robin , Kudo, Shin-ei, Barua, Ishita , Misawa, Masashi , Hunt, Claire , Nilsen, Jens Aksel , Frigstad, Svein Oskar , Rastogi, Amit, Holme, Øyvind , Gulati, Shraddha , Hassan, Cesare , Hayee, Bu , Mori, Yuichi , Kudo, Shin-ei, Mori, Kensaku , Hunt, Claire, East, James E. , Hassan, Cesare , Kalager, Mette , Løberg, Magnus , Haji, Amyn , Bretthauer, Michael , Mori, Yuichi

Mayo Clinic

Endoscopy | October 7, 2025 | Volume: 58 | Issue: 03 | Pages: 303-309

10.1055/a-2717-8365 | PMID 41056995 Get It

Abstract The environmental impact of computer-aided diagnosis (CADx) in colonoscopy is unknown. The potential to reduce greenhouse gas emissions by limiting unnecessary polypectomies may be offset by emissions associated with CADx devices. We quantified and compared the carbon footprint of colonoscopy with and without CADx. Life-cycle carbon emissions associated with endoscopic snares, polyp traps, histopathology, and CADx devices were estimated using life-cycle assessment software. The effect of CADx was estimated by the carbon dioxide equivalent (CO2e) emissions related to outcomes from a prospective cohort of patients who underwent colonoscopy with optical diagnosis under a leave-in-situ strategy (i.e. rectosigmoid polyps ≤5 mm predicted as non-neoplastic were not removed) with and without CADx assistance. We analyzed 1134 individuals (median age 67 years, 59% male) with 1716 colorectal polyps. Colonoscopy with CADx reduced the number of snares and polyp traps from 567 to 543 (difference: 24) and histopathology submissions from 1343 to 1278 (difference: 65). However, the total carbon footprint increased from 832 kg CO2e (95%CI 815 to 847) without CADx to 946 kg CO2e (95%CI 927 to 965) with CADx, corresponding to an absolute increase of 114 kg CO2e (95%CI 80 to 150) or 0.10 kg CO2e per colonoscopy. Using CADx under a leave-in-situ strategy increased the environmental burden of colonoscopy.
Artificial Intelligence-Assisted Colonoscopy With or Without Mucosal Exposure Device for Detection of Colorectal Adenomas: A Meta-Analysis
Beran, Azizullah , Ramai, Daryl, Albakri, Almaza A., Spadaccini, Marco , Hassan, Cesare , Guardiola, John , Rex, Douglas K., Spadaccini, Marco , Hassan, Cesare , Guardiola, John J , Nayfeh, Tarek , Saleem, Nasir , Repici, Alessandro

Mayo Clinic

Endoscopy International Open | August 4, 2025 | Volume: 13 | Issue: CP | Pages: No page available

10.1055/a-2676-4144 | PMID 40932819 Get It

Abstract Artificial intelligence (AI) and mucosal exposure devices like Endocuff have independently improved the adenoma detection rate (ADR) during colonoscopy. This meta-analysis evaluated the combined effect of Endocuff and AI versus AI alone on colorectal neoplasia detection rates. We searched PubMed, Embase, and Web of Science for randomized controlled trials (RCTs) comparing the impact of Endocuff+AI versus AI alone on colorectal neoplasia detection. Primary outcome was ADR; secondary outcomes included advanced adenoma detection rate (AADR), sessile serrated lesion detection rate (SSLDR), cecal intubation time, and withdrawal time. Pooled risk ratios (RRs) and mean differences (MDs) with 95% confidence intervals (CIs) were calculated using a random-effects model. Three RCTs with 2404 subjects were included (n = 1198 Endocuff+AI vs. n = 1206 AI alone). ADR was significantly higher in the Endocuff+AI group than in the AI alone group (54% vs. 48%, respectively) (RR 1.12, 95% CI 1.03–1.21, P = 0.01, I2 = 0%). There was a trend toward higher AADR (12.3% vs. 10%, RR 1.23, 95% CI 0.96–1.59, P = 0.10, I2 = 17%) and SSLDR (17.6% vs. 15.5%, RR 1.16, 95% CI 0.96–1.40, P = 0.13, I2 = 0%) in the Endocuff+AI group compared with the AI alone group, but it did not reach statistical significance. Both cecal intubation time (MD -0.61 minutes; 95% CI -1.54–0.33; P = 0.20; I2 = 87%) and withdrawal time (MD -0.42 minutes; 95% CI -1.01–0.17; P = 0.17, I2 = 60%) were similar between the two groups. Endocuff combined with AI was superior to AI alone in improving the adenoma detection rate without increasing intubation or withdrawal times.
Computer‐aided detection for esophageal achalasia (with video)
Shiwaku, Hironari , Misawa, Masashi , Inoue, Haruhiro , Boškoski, Ivo , Shimamura, Yuto , Ikebuchi, Yuichiro , Ominami, Masaki , Htet, Hein , Messmann, H, Colosso, Bianca Maria Quarta , Repici, Alessandro , Stavropoulos, Stavros N. , Bechara, Robert , Sethi, Amrita, Beyna, Torsten , Santi, Esperanza Grace , Sharma, Prateek , Eleftheriadis, Nikolas, Minami, Hitomi, Haber, Gregory , Seewald, Stefan , Shiwaku, Akio, Shiwaku, Yoshiyuki, Mori, Kensaku, Costamagna, Guido , Shimamura, Yuto , Ikebuchi, Yuichiro , Iwaya, Yugo , Htet, Hein Myat Thu , Colosso, Bianca Maria Quarta , Bechara, Robert , Kahaleh, Michel , Beyna, Torsten , Jiang, Kai, Oda, Masahiro , Familiari, Pietro , Hayee, Bu , Ho, Khek Yu , So, Jimmy Bok Yan , Bhandari, Pradeep , Grimes, Kevin L. , Maselli, Roberta , Hassan, Cesare , Fukami, Norio , Kahaleh, Michel , Sethi, Amrita , Neuhaus, Horst Ekkehard , Chiu, Philip Wai Yan , Eleftheriadis, Nikolas, Draganov, Peter V. , Mori, Kensaku , Kudo, Shin‐ei , Hasegawa, Suguru

Mayo Clinic

Digestive Endoscopy | June 12, 2025 | Volume: 37 | Issue: 8 | Pages: 851-861

10.1111/den.15028 | PMID 40506418 Get It

ObjectivesAchalasia is an esophageal motility disorder that impairs quality of life and is often missed (20–50%) on endoscopy. A newly developed computer‐aided detection (CAD) software has shown high accuracy for achalasia diagnosis in preclinical settings. However, its benefit in a clinical setting remains unclear.MethodsBetween February and August 2023, 83 endoscopists from 27 centers assessed 50 randomized endoscopic videos (25 achalasia, 25 nonachalasia) without and with CAD. Endoscopists assessed videos without CAD, then with CAD after 2 months. The primary end‐point was improvement in sensitivity for nonexperienced endoscopists (no endoscopic experience of achalasia). Sensitivity, specificity, and accuracy with and without CAD were compared using the McNemar test.ResultsSensitivity for diagnosing achalasia increased significantly with CAD, rising from 74.2% (95% confidence interval [CI] 72.2–76.0%) to 91.2% (95% CI 89.9–92.4%) for all readers, showing a difference of 17.1% (95% CI 15.1–19.0%). Specifically, sensitivity improved from 66.9% (95% CI 63.6–70.0%) to 91.9% (95% CI 89.9–93.6%) among nonexperienced endoscopists, resulting in a difference of 25.0% (95% CI 21.7–28.4%), and from 79.5% (95% CI 77.1–81.8%) to 90.8% (95% CI 89.0–92.3%) among experienced endoscopists (endoscopic experience of at least one achalasia case), with a difference of 11.3% (95% CI 8.9–13.6%). Accuracy and specificity improved significantly with CAD assistance, regardless of reader's experience.ConclusionCAD improves achalasia detection by 17%, confirming preclinical results. The benefit was higher for nonexperienced endoscopists. CAD assistance may lead to prompt and effective treatment, minimizing the risk of false‐negative diagnosis in clinical practice.Trial registrationThis study was registered in the University Hospital Medical Information Network Clinical Trial Registry (https://www.umin.ac.jp/ctr/) number: UMIN000053047.
Position statement of the World Endoscopy Organization: Role of endoscopy in screening, diagnosis, and treatment of esophageal superficial squamous neoplasiaia
Hassan, Cesare , Goda, Kenichi, Iyer, Prasad G. , Awadhi, Sameer Al , Lehibi, Abed Al , Arantes, Vitor , Burgos, Herbert, Cerisoli, Cecilio L., Dawsey, Sanford, Fleischer, David, Fluxá, Fernando, Inoue, Haruhiro , John, Sneha , Khashab, Mouen A., Kothari, Shivangi , Lee, Yeong Yeh, Ngamruengphong, Saowanee , Sharara, Ala I. , Shimamura, Yuto , Varocha, Mahachai, Villa‐Gomez, Guido, Wang, Kenneth K. , Yip, Hon Chi , Sharma, Prateek , Lee, Yeong Yeh , Chiu, Philip Wai Yan , Emura, Fabian , G Iyer, Prasad, Kim, Gwang Ha , Shimamura, Yuto , Yip, Hon-Chi , Hassan, Cesare , Lee, Yeong Yeh , Antonelli, Giulio , Burgos, Herbert, Dawsey, Sanford, Draganov, Peter V. , González, Nicolás , Kashin, Sergey V. , Khashab, Mouen A. , Lee, Yeong Yeh, Remes Troche, José M , Varocha, Mahachai, Wang, Wen‐Lun

Mayo Clinic

Digestive Endoscopy | December 26, 2024 | Volume: 37 | Issue: 5 | Pages: 470-489

10.1111/den.14967 | PMID 39722219 Get It

Esophageal squamous cell carcinoma (ESCC) remains a significant global health challenge, being the sixth leading cause of cancer mortality with pronounced geographic variability. The incidence rates range from 125 per 100,000 in northern China to 1–1.5 per 100,000 in the United States, driven by environmental and lifestyle factors such as tobacco and alcohol use, dietary habits, and pollution. Major modifiable risk factors include tobacco and alcohol consumption, with a synergistic risk increase when combined. Nonmodifiable risk factors include previous diagnoses of head and neck squamous cell carcinoma (H&N SCC), achalasia, and prior radiotherapy. Prevention strategies must be tailored to specific regional burdens to efficiently allocate medical and financial resources. Gastrointestinal endoscopy is crucial in reducing ESCC burden through early detection and characterization of neoplastic changes, such as high‐grade dysplasia. Early diagnosis significantly improves survival rates, while endoscopic resection of noninvasive dysplasia can prevent ESCC onset, reducing treatment burden for advanced disease. Postresection surveillance can detect high‐risk metachronous lesions. Despite these benefits, endoscopic prevention faces challenges, including the lack of high‐level evidence supporting its efficacy, opportunity costs, the need for specialized training and techniques, and the requirement for advanced technology investments. This Position Statement from the World Endoscopy Organization (WEO) aims to address these challenges, supplying recommendations for the exploitation of endoscopic resources regarding the possible role of screening, quality, and training for the detection, characterization, resection, and surveillance of ESCC.
International Validation of a Novel PEACE Scale to Improve the Quality of Upper Gastrointestinal Mucosal Inspection During Endoscopy
Romańczyk, Marcin , Desai, Madhav , Abe, Seiichiro , Alkandari, Asma , Beyna, Torsten , Bisschops, Raf , Budzyń, Krzysztof , Grover, Samir C. , Gyawali, C. Prakash, Inoue, Haruhiro , Iyer, Prasad G. , Srinivasan, Sachin , Gyawali, C. Prakash , Hassan, Cesare , Gyawali, C P , Hassan, Cesare , Bisschops, Raf , Grover, Samir C , Kaminski, Michal Filip , Bugdol, Monika Natalia , Messmann, Helmut , Ragunath, Krish , Saito, Yutaka , Teshima, Christopher , Yadlapati, Rena , Sharma, Prateek

Mayo Clinic

Clinical and Translational Gastroenterology | November 14, 2024 | Volume: 16 | Issue: 1 | Pages: e00786

10.14309/ctg.0000000000000786 | PMID 39853720 Get It

INTRODUCTION: The performance of a high quality esophagogastroduodenoscopy (EGD) is dependent on the mucosal cleanliness. Recently, the Polprep: Effective Assessment of Cleanliness in EGD (PEACE) scale was created to assess the degree of mucosal cleanliness during EGD. The aim of this study was to validate this scoring system in a cohort of international endoscopists. METHODS: In total, 39 EGD videos, with different degrees of mucosal cleanliness were retrieved from a previously conducted prospective trial. All experts rated the cleanliness of the mucosa on each video using the PEACE scale. To evaluate agreement of all scores (0–3), intraclass correlation coefficient 2.1 was used. The agreement on adequate (scores 2 and 3) and inadequate (scores 0 and 1) cleanliness was assessed using kappa values. RESULTS: Videos evaluating esophagus, stomach, and duodenum cleanliness were reviewed by 16 endoscopists. The PEACE scores demonstrated good agreement (intraclass correlation coefficient 0.82, 95% CI 0.75–0.89), especially for esophagus (0.84; 95% CI 0.71–0.95) and stomach (0.81; 95% CI 0.69–0.91), while agreement was moderate for the duodenum (0.69; 95% CI 0.51–0.87). The agreement was similar between Eastern (0.86; 95% CI 0.79–0.92) and Western experts (0.80; 95% CI 0.72–0.88). Similarly, agreement regarding adequate cleanliness was comparable between Eastern (0.70; 95% CI 0.55–0.85) and Western (0.74; 95% CI 0.64–0.84) endoscopists being overall 0.75 (95% CI 0.65–0.85). DISCUSSION: The PEACE scoring system is a simple and reliable scale to assess the cleanliness during EGD. The score is now validated among international experts with high concordance, justifying its use in clinical practice.
Defining standards for fluoroscopy in gastrointestinal endoscopy using Delphi methodology
Khalaf, Kareem , Pawlak, Katarzyna M. , Alkandari, Asma , Baron, Todd H. , Bechara, Robert , Binda, Cecilia , Chen, Yen‐I , Moura, Eduardo Guimarães Hourneaux de , Forbes, Nauzer , James, Paul, Martin, Harry , May, Gary R. , Mosko, Jeffrey D. , Oyeleke, Ganiyat K. , Petersen, Bret T. , Saxena, Payal , Sethi, Amrita , Sharaiha, Reem Z. , Tang, Raymond S. , Villarroel, Mariano , Hooft, Jeanin E. van , Renteln, Daniel von , Walsh, Catharine M. , Aberin, Tricia, Banavage, Dawn, Chen, Jowell Akina, Clancy, James, Drake, Heather, Im, Melanie, Low, Chooi Peng, Myszko, Alexandra, Navarro, Krista, Redman, Jessica, Reyes, Wayne, Weinstein, Faina, Na, Caleb, Tham, Daniel , He, Tony , Malipatil, Sharan B., Gimpaya, Nikko , Kundra, Arjun , Grover, Samir C. , Barkun, Alan N , Bechara, Robert , Binda, Cecilia , de Moura, Eduardo , Hassan, Cesare , Kahaleh, Michel , Sharaiha, Reem Z , Villarroel, Mariano , van Hooft, Jeanin E , Voermans, Rogier P , von Renteln, Daniel , Walsh, Catharine M , Gupta, Sunil , Fujiyoshi, Yusuke , Grover, Samir C , Causada Calo, Natalia S , Pawlak, Katarzyna M , Adler, Douglas G. , Barkun, Alan , Berzin, Tyler M. , Cai, Ming‐Yan , Carrara, Silvia , Fugazza, Alessandro , Hassan, Cesare , James, Paul D., Kahaleh, Michel , Maselli, Roberta , Repici, Alessandro , Spadaccini, Marco , Teshima, Christopher , Voermans, Rogier P. , Clancy, James, Reyes, Wayne, Gupta, Sunil , Mokhtar, Ahmed H., Gholami, Reza

Mayo Clinic

Endoscopy International Open | October 7, 2024 | Volume: 12 | Issue: 11 | Pages: E1315-E1325

10.1055/a-2427-3893 | PMID 39559412 Get It

Abstract Background and study aims Use of fluoroscopy in gastrointestinal endoscopy is an essential aid in advanced endoscopic interventions. However, it also raises concerns about radiation exposure. This study aimed to develop consensus-based statements for safe and effective use of fluoroscopy in gastrointestinal endoscopy, prioritizing the safety and well-being of healthcare workers and patients. Methods A modified Delphi approach was employed to achieve consensus over three rounds of surveys. Proposed statements were generated in Round 1. In the second round, panelists rated potential statements on a 5-point scale, with consensus defined as ≥80% agreement. Statements were subsequently prioritized in Round 3, using a 1 (lowest priority) to 10 (highest priority) scale. Results Forty-six experts participated, consisting of 34 therapeutic endoscopists and 12 endoscopy nurses from six continents, with an overall 45.6% female representation (n = 21). Forty-three item statements were generated in the first round. Of these, 31 statements achieved consensus after the second round. These statements were categorized into General Considerations (n = 6), Education (n = 10), Pregnancy (n = 4), Family Planning (n = 2), Patient Safety (n = 4), and Staff Safety (n = 5). In the third round, accepted statements received mean priority scores ranging from 7.28 to 9.36, with 87.2% of statements rated as very high priority (mean score ≥ 9). Conclusions This study presents consensus-based statements for safe and effective use of fluoroscopy in gastrointestinal endoscopy, addressing the well-being of healthcare workers and patients. These consensus-based statements aim to mitigate risks associated with radiation exposure while maintaining benefits of fluoroscopy, ultimately promoting a culture of safety in healthcare settings.
Benefits and harms of optical diagnosis by artificial intelligence in colonoscopy: a multicentre cohort study
Halvorsen, Natalie , Kudo, S., Barua, Ishita , Misawa, Masashi , Gulati, Shraddha , Olabintan, Olaolu , Nilsen, J. A., Frigstad, Svein Oskar , Rastogi, A. , Holme, Øyvind , Yuichi, M., Mori, Kensaku , Hayee, Bu , East, James E. , Hassan, Cesare , Kalager, Mette , Løberg, Magnus , Haji, Amyn , Bretthauer, Michael , Yuichi, M.

Mayo Clinic

Endoscopy | April 23, 2024 | Volume: 56 | Issue: S 02 | Pages: S55-S56

10.1055/s-0044-1782806 Get It

International validation of a PEACE scale assessing cleanliness during esophagogastroduodenoscopy to improve the quality of inspection during endoscopy
Romańczyk, Monika , Desai, Madhav , Abe, Seiichiro , Alkandari, Asma , Beyna, Torsten , Budzyń, Krzysztof , Grover, Samir C. , Gyawali, P. , Iyer, Prasad G. , Srinivasan, Sachin , Grover, Samir C , Kaminski, Michal Filip , Bisschops, Raf , Bugdol, Marcin Dominik , Gyawali, P., Inoue, H., Messmann, Helmut , Ragunath, Krish , Saito, Yutaka , Teshima, Christopher , Yadlapati, Rena , Hassan, Cesare , Sharma, Prateek

Mayo Clinic

Endoscopy | April 23, 2024 | Volume: 56 | Issue: S 02 | Pages: S27-S28

10.1055/s-0044-1782743 Get It