Citations

Clear

12 citation(s) found for "Grover, Michael".

A Comprehensive Quality Improvement Approach to Better Patient Experience
Grover, Michael , Pullins, Christopher , Chavez, Augustine , Yennie, Julia, Mi, Lanyu , Pullins, Christopher T, Chavez, Augustine S , Yennie, Julia F

Mayo Clinic

NEJM Catalyst | December 17, 2025 | Volume: 7 | Issue: 1 | Pages: No page available

10.1056/cat.25.0006 | PMID 42412418 Get It

A47 VIRTUAL REALITY SIMULATION TRAINING IN GASTROINTESTINAL ENDOSCOPY: A COCHRANE REVIEW
Sabrie, Nasruddin , Plahouras, Joanne, Grover, Samir C. , Walsh, Colin , Grover, Samir C , Khan, Rishad , Johnston, Bradley C. , Scaffidi, Michael A. , Walsh, C

Mayo Clinic

Journal of the Canadian Association of Gastroenterology | February 10, 2025 | Volume: 8 | Issue: Supplement_1 | Pages: i19-i20

10.1093/jcag/gwae059.047 Get It

Abstract Background Training with virtual reality (VR) simulation is increasingly used for health professions training to allow novices to practice in a learner-centered, risk-free environment. This review was performed to evaluate the effectiveness of VR simulation training in gastrointestinal endoscopy. Aims To determine whether virtual reality simulation training can supplement and/or replace early conventional endoscopy training in diagnostic endoscopy for health professions trainees with limited or no prior endoscopic experience. Methods We searched 17 databases from inception until October 18, 2023. We included randomised and quasi-randomised trials that compared VR simulation training with no training, conventional training, another form of simulation training, or an alternative method of VR training. We screened and abstracted data through Cochrane methodology. The primary outcome was composite score of competency. Secondary outcomes were procedure completion, procedure time, adverse events, patient discomfort, global rating of competency, and mucosal visualization. We calculated risk ratio for dichotomous outcomes and mean difference (MD) or standardised mean difference (SMD) for continuous outcomes with 95% CI. We used GRADE to assess the certainty of evidence. Results We included 20 trials (500 participants; 3975 endoscopic procedures). There was insufficient evidence to determine the effect of VR training on composite score of competency compared to no training or conventional training. VR training was advantageous over no training based for independent procedure completion (RR 1.62, 95% CI 1.15 to 2.26; moderate certainty evidence), overall rating of performance (mean difference [MD] 0.45, 95 %CI 0.15 - 0.75, very low certainty evidence), and mucosal visualization (MD 0.60, 95 %CI 0.20 - 1.00, very low certainty evidence). VR training resulted in fewer independent procedure completions compared to conventional training (RR = 0.45, 95 %CI 0.27 - 0.74, low certainty evidence). We found no differences between VR training and no training or conventional training for other outcomes. Based on qualitative analysis, we found no significant differences between VR training and other forms of simulation training. VR curricula based in educational theory provided benefit with respect to composite score of competency, compared with unstructured curricula. Based on qualitative analysis, we found no significant differences between VR training and other forms of simulation training. VR curricula based in educational theory provided benefit with respect to composite score of competency, compared with unstructured curricula. Conclusions VR simulation training in endoscopy can supplement conventional endoscopy training and provides benefit compared to no training. Risk of bias summary Funding Agencies None
A39 IMPACT OF AN ENDOSCOPIC OPTICAL DIAGNOSIS COURSE ON GASTROINTESTINAL NEOPLASM CHARACTERIZATION SKILLS AMONG TRAINEE ENDOSCOPISTS
Hookey, Lawrence , Rai, Mandip , Grover, Samir C. , Grover, Samir C , Tran, W, Gimpaya, Nikko , Khan, Rishad , Walsh, Catharine M. , Bechara, Robert

Mayo Clinic

Journal of the Canadian Association of Gastroenterology | February 10, 2025 | Volume: 8 | Issue: Supplement_1 | Pages: i15-i15

10.1093/jcag/gwae059.039 Get It

Abstract Background Real-time endoscopic optical diagnosis involves detailed visualization of the digestive mucosal and microvascular pattern, allowing for prediction of histology. This is advantageous as it can guide endoscopic resection decisions, surgical referrals and provide cost savings to histopathology. There is, however, no standardized or widely implemented curriculum for endoscopists or trainees to learn optical diagnosis skills. Aims To evaluate the impact of a course for the optical diagnosis of esophageal squamous cell carcinoma (ESCC), early gastric cancer (EGC), Barrett’s esophagus (BE), and colorectal polyps Methods 19 gastroenterology trainees were invited to the 2-day course in Kingston, Canada. Number of procedures previously performed was recorded. The impact of the course on lesion diagnosis accuracy was evaluated using a pre-test, immediate post-test, and delayed post-test administered 6 weeks after the course. A repeated measures ANOVA was performed to compare the mean score (%) between the three tests. Results 13 trainees completed all the tests (Table 1). Mean score % values for the overall tests and test scores for esophageal, gastric, and colon lesions were summarized on Table 1. The repeated measures ANOVA determined that the mean score % had a statistically significant difference between the three tests (F (2,24)=5.63, P=0.01). Pairwise comparisons revealed that there was a statistically significant increase in mean scores between pre- and post-tests (13.86 (95% confidence interval (CI) of 4.36 to 23.33), p<0.01) with no significant difference between post and delayed post-tests (8.46 (95% CI of -0.12 to 17.04), p>0.05) (Figure 1). The mean correct % from the delayed post-test was higher than the pre-test but there was no statistical significance (5.39 (95% CI of -3.72 to 14.49), p>0.05). Conclusions This novel optical diagnosis course improved trainee accuracy in diagnosing ESCC, EGC, BE and colorectal polyps. Learning retention was evident, with no significant score difference between immediate and delayed post-tests. This study was limited by the low sample size and low number of test items. Further investigation is required to validate the course for international trainees and explore its clinical transferability. Demography and Mean Score % Figure 1. Mean score %. (*) denotes p<0.05. Funding Agencies None
International Validation of a Novel PEACE Scale to Improve the Quality of Upper Gastrointestinal Mucosal Inspection During Endoscopy
Romańczyk, Marcin , Desai, Madhav , Abe, Seiichiro , Alkandari, Asma , Beyna, Torsten , Bisschops, Raf , Budzyń, Krzysztof , Grover, Samir C. , Gyawali, C. Prakash, Inoue, Haruhiro , Iyer, Prasad G. , Srinivasan, Sachin , Gyawali, C. Prakash , Hassan, Cesare , Gyawali, C P , Hassan, Cesare , Bisschops, Raf , Grover, Samir C , Kaminski, Michal Filip , Bugdol, Monika Natalia , Messmann, Helmut , Ragunath, Krish , Saito, Yutaka , Teshima, Christopher , Yadlapati, Rena , Sharma, Prateek

Mayo Clinic

Clinical and Translational Gastroenterology | November 14, 2024 | Volume: 16 | Issue: 1 | Pages: e00786

10.14309/ctg.0000000000000786 | PMID 39853720 Get It

INTRODUCTION: The performance of a high quality esophagogastroduodenoscopy (EGD) is dependent on the mucosal cleanliness. Recently, the Polprep: Effective Assessment of Cleanliness in EGD (PEACE) scale was created to assess the degree of mucosal cleanliness during EGD. The aim of this study was to validate this scoring system in a cohort of international endoscopists. METHODS: In total, 39 EGD videos, with different degrees of mucosal cleanliness were retrieved from a previously conducted prospective trial. All experts rated the cleanliness of the mucosa on each video using the PEACE scale. To evaluate agreement of all scores (0–3), intraclass correlation coefficient 2.1 was used. The agreement on adequate (scores 2 and 3) and inadequate (scores 0 and 1) cleanliness was assessed using kappa values. RESULTS: Videos evaluating esophagus, stomach, and duodenum cleanliness were reviewed by 16 endoscopists. The PEACE scores demonstrated good agreement (intraclass correlation coefficient 0.82, 95% CI 0.75–0.89), especially for esophagus (0.84; 95% CI 0.71–0.95) and stomach (0.81; 95% CI 0.69–0.91), while agreement was moderate for the duodenum (0.69; 95% CI 0.51–0.87). The agreement was similar between Eastern (0.86; 95% CI 0.79–0.92) and Western experts (0.80; 95% CI 0.72–0.88). Similarly, agreement regarding adequate cleanliness was comparable between Eastern (0.70; 95% CI 0.55–0.85) and Western (0.74; 95% CI 0.64–0.84) endoscopists being overall 0.75 (95% CI 0.65–0.85). DISCUSSION: The PEACE scoring system is a simple and reliable scale to assess the cleanliness during EGD. The score is now validated among international experts with high concordance, justifying its use in clinical practice.
Defining standards for fluoroscopy in gastrointestinal endoscopy using Delphi methodology
Khalaf, Kareem , Pawlak, Katarzyna M. , Alkandari, Asma , Baron, Todd H. , Bechara, Robert , Binda, Cecilia , Chen, Yen‐I , Moura, Eduardo Guimarães Hourneaux de , Forbes, Nauzer , James, Paul, Martin, Harry , May, Gary R. , Mosko, Jeffrey D. , Oyeleke, Ganiyat K. , Petersen, Bret T. , Saxena, Payal , Sethi, Amrita , Sharaiha, Reem Z. , Tang, Raymond S. , Villarroel, Mariano , Hooft, Jeanin E. van , Renteln, Daniel von , Walsh, Catharine M. , Aberin, Tricia, Banavage, Dawn, Chen, Jowell Akina, Clancy, James, Drake, Heather, Im, Melanie, Low, Chooi Peng, Myszko, Alexandra, Navarro, Krista, Redman, Jessica, Reyes, Wayne, Weinstein, Faina, Na, Caleb, Tham, Daniel , He, Tony , Malipatil, Sharan B., Gimpaya, Nikko , Kundra, Arjun , Grover, Samir C. , Barkun, Alan N , Bechara, Robert , Binda, Cecilia , de Moura, Eduardo , Hassan, Cesare , Kahaleh, Michel , Sharaiha, Reem Z , Villarroel, Mariano , van Hooft, Jeanin E , Voermans, Rogier P , von Renteln, Daniel , Walsh, Catharine M , Gupta, Sunil , Fujiyoshi, Yusuke , Grover, Samir C , Causada Calo, Natalia S , Pawlak, Katarzyna M , Adler, Douglas G. , Barkun, Alan , Berzin, Tyler M. , Cai, Ming‐Yan , Carrara, Silvia , Fugazza, Alessandro , Hassan, Cesare , James, Paul D., Kahaleh, Michel , Maselli, Roberta , Repici, Alessandro , Spadaccini, Marco , Teshima, Christopher , Voermans, Rogier P. , Clancy, James, Reyes, Wayne, Gupta, Sunil , Mokhtar, Ahmed H., Gholami, Reza

Mayo Clinic

Endoscopy International Open | October 7, 2024 | Volume: 12 | Issue: 11 | Pages: E1315-E1325

10.1055/a-2427-3893 | PMID 39559412 Get It

Abstract Background and study aims Use of fluoroscopy in gastrointestinal endoscopy is an essential aid in advanced endoscopic interventions. However, it also raises concerns about radiation exposure. This study aimed to develop consensus-based statements for safe and effective use of fluoroscopy in gastrointestinal endoscopy, prioritizing the safety and well-being of healthcare workers and patients. Methods A modified Delphi approach was employed to achieve consensus over three rounds of surveys. Proposed statements were generated in Round 1. In the second round, panelists rated potential statements on a 5-point scale, with consensus defined as ≥80% agreement. Statements were subsequently prioritized in Round 3, using a 1 (lowest priority) to 10 (highest priority) scale. Results Forty-six experts participated, consisting of 34 therapeutic endoscopists and 12 endoscopy nurses from six continents, with an overall 45.6% female representation (n = 21). Forty-three item statements were generated in the first round. Of these, 31 statements achieved consensus after the second round. These statements were categorized into General Considerations (n = 6), Education (n = 10), Pregnancy (n = 4), Family Planning (n = 2), Patient Safety (n = 4), and Staff Safety (n = 5). In the third round, accepted statements received mean priority scores ranging from 7.28 to 9.36, with 87.2% of statements rated as very high priority (mean score ≥ 9). Conclusions This study presents consensus-based statements for safe and effective use of fluoroscopy in gastrointestinal endoscopy, addressing the well-being of healthcare workers and patients. These consensus-based statements aim to mitigate risks associated with radiation exposure while maintaining benefits of fluoroscopy, ultimately promoting a culture of safety in healthcare settings.
International validation of a PEACE scale assessing cleanliness during esophagogastroduodenoscopy to improve the quality of inspection during endoscopy
Romańczyk, Monika , Desai, Madhav , Abe, Seiichiro , Alkandari, Asma , Beyna, Torsten , Budzyń, Krzysztof , Grover, Samir C. , Gyawali, P. , Iyer, Prasad G. , Srinivasan, Sachin , Grover, Samir C , Kaminski, Michal Filip , Bisschops, Raf , Bugdol, Marcin Dominik , Gyawali, P., Inoue, H., Messmann, Helmut , Ragunath, Krish , Saito, Yutaka , Teshima, Christopher , Yadlapati, Rena , Hassan, Cesare , Sharma, Prateek

Mayo Clinic

Endoscopy | April 23, 2024 | Volume: 56 | Issue: S 02 | Pages: S27-S28

10.1055/s-0044-1782743 Get It

Examining the Utility of a Novel Neurologic Test in Patients With Obstructive Sleep Apnea: A Pilot Study
Grover, Michael , Grover, Lori L., Mookadam, Martina , Mi, Lanyu , Parish, James M., Grover, Michael L , Parish, James, Chang, Yu‐Hui

Mayo Clinic

Journal of Primary Care & Community Health | November 21, 2019 | Volume: 10 | Issue: No issue available | Pages: No page available

10.1177/2150132719886951 | PMID 31747842 Get It

Purpose: To test the association between participant King-Devick Test (KDT) times and obstructive sleep apnea (OSA) severity and evaluate for improvement after continuous positive airway pressure (CPAP) treatment. Methods: Study dates January 30 to July 31, 2018. Patients were referred for initial evaluation of sleep disordered breathing concerns. OSA severities were defined by Apnea Hypopnea Index (AHI) results, with ≥15 considered at least moderate OSA. The KDT is an objective physical measure of brain function. We estimated correlation between KDT time and AHI and compared mean KDT time between patients with and without moderate OSA. For the OSA subgroup, we evaluated for potential improvement in KDT after CPAP. Results: We enrolled 60 participants, of whom 35 (58.3%) had OSA with an AHI ≥15. Initial analyses noted no significant KDT time differences between patients based on OSA severity. However, after excluding 3 participants who had baseline neurologic illness, adjusted analyses demonstrated that mean KDT time was significantly prolonged for patients with moderate or greater OSA (AHI ≥15) as compared to those with mild or no sleep apnea (AHI <15); 63.4 seconds (95% CI 58.9-67.8) versus 55.7 seconds (95% CI 50.2-61.1), P = .03. CPAP-treated subjects demonstrated significantly improved KDT test times; 63.5 seconds mean pretreatment versus 55.6 posttreatment; −6.6 seconds mean difference, 95%CI (−12.0, −1.13), P = .02. Conclusion: Neurologic abnormalities in patients with OSA are potentially demonstrable utilizing this objective physical measure. Significant improvement is achieved in patients after CPAP treatment.
Impact of standardized templates and skin cancer learning modules for teledermatology consultations
Cumsky, Helen J.L., Maly, Connor , Costello, Collin M. , Buras, Matthew , Ranieri, LeeAnn M., Grover, Michael , Comfere, Nneka I. , Nelson, Steven A. , Pittelkow, Mark R. , Mangold, Aaron R. , Maly, Connor J, Grover, Michael L, Mangold, A R , Buras, Matthew R , Costello, Collin M

Mayo Clinic

International Journal of Dermatology | March 28, 2019 | Volume: 58 | Issue: 12 | Pages: 1423-1429

10.1111/ijd.14437 | PMID 30916785 Get It

AbstractBackgroundLittle research has been done in teledermatology to examine the effects of standardized templates and subject‐specific learning modules.MethodsWe performed a prospective study examining the effects of standardized templates and standardized cutaneous oncology learning modules on teledermatology referrals at Mayo Clinic. This data was then compared to previous teledermatology referrals before standardized templates were adopted.ResultsA total of 42 teledermatology consultations were performed during the 4‐month study period. The use of standardized templates resulted in an absolute reduction in face‐to‐face referrals. Teledermatology consultation increased the absolute diagnostic and management concordance by 26.2% (P = 0.02) and 33.3% (P < 0.01), respectively, and decreased the absolute diagnostic and management discordance by 19.1% (P = 0.03) and 31.0% (P < 0.01), respectively. The largest knowledge gaps were identified in cutaneous oncology. Educational intervention improved theoretical referral rates and confidence in diagnosis and management overall.ConclusionThe implementation of standardized intake templates reduces the rate of face‐to‐face referrals. Teledermatology improves primary care‐based dermatological care and reduces theoretical referral rates.
Simple Interventions Improve the Quality of a Missed Lab Appointment Process
Mookadam, Martina , Grover, Michael , Pullins, Chris, Winscott, Mary, Pierce, Susan, Pullins, Christopher , Pierce, Susan

Mayo Clinic

BMJ Quality Improvement Reports | May 5, 2016 | Volume: 5 | Issue: 1 | Pages: u205944.w2432

10.1136/bmjquality.u205944.w2432 | PMID 27239304 Get It

Simple interventions resolve the problem of missed lab appointments. It is essential that patients complete ordered laboratory studies. This maintains clinical quality and, potentially, keeps patients safe from harm. In our academic family medicine practice, baseline data demonstrated patients completed 94.7% of labs as ordered (26850/28348 patients per year) while 1498 (5.3%) did not. Our baseline patient reminder process, a mail or portal based generic letter, resulted in only 449 (30%) of patients ultimately completing them (1049 [70%] did not). Our baseline system was 96.3 % reliable. This process did not allow for provider review or input, and was not personalized for patients. We designed a quality improvement project involving three PDSA (Plan, Do, Study, and Act) cycles of about two months each. Desk staff created weekly reports of unresolved lab orders. A message in the electronic medical record (EMR) solicited provider input. Providers could elect to cancel studies (if already completed, reordered, or no longer clinically indicated) or have the patient receive a personalized reminder, including provider name and associated diagnoses. This reminder was sent by patient portal secure messaging (if an account existed) or with a mailed letter. These interventions resulted in 98.8 % process reliability. The frequency of unresolved lab orders decreased from 70% at baseline to 25%. In the second PDSA cycle, we contacted patients by the portal only if there was evidence of an active account. Otherwise, they were contacted by telephone. Patients without a portal account continued to receive a letter by mail. These modified processes resulted in an overall reliability rate of 99.2%. The frequency of unresolved lab orders decreased to 17%. A final PDSA cycle utilized only telephone contact with patients with unresolved lab orders. Schedulers offered patients a choice of appointment dates if they spoke personally. Otherwise, they were left messages with a future lab appointment date two weeks later.Overall process reliability now increased to 100%. The frequency of unresolved lab orders decreased to 0%. Our interventions resulted in increased system reliability.Provider input was not perceived as burdensome. Desk staff work effort was not increased.Telephone patient contact resulted in more frequent lab order completion than other methods.