Abstract Introduction Adherence to continuous positive airway pressure (CPAP) therapy is difficult for many patients with obstructive sleep apnea. Clinical outcomes are improved with CPAP adherence ≥6 hr/night, yet scalable approaches to personalized support are limited. We developed a theory-based, clinic experience–driven conceptual dynamical model for optimizing CPAP use and applied it to a ‘just-in-time’ adaptive version of SleepWell24, a smartphone application integrating near–real-time wearable data, CPAP use, and patient-reported symptoms and CPAP-related problems with evidence-based behavior change interventions. In this feasibility optimization trial, we examined patient acceptability and initial outcomes of the adaptive SleepWell24 platform, and guided by the conceptual model, evaluated a control systems engineering approach to demonstrate, in simulation, improved CPAP adherence. Methods Aim 1: Naïve CPAP users (N=10; M age=61.7, 60% female) participated in this 60-day ongoing trial. Patients were encouraged to interact daily with SleepWell24 to report symptoms, receive personalized troubleshooting recommendations, set goals, and receive feedback on CPAP use (via Wi-Fi-enabled smart plug assessing CPAP ‘on/off state’) and sleep/activity (Fitbit). We assessed SleepWell24 use, post-intervention acceptability, and consistent CPAP use defined as ≥6hr, for ≥6nights/week for ≥2 consecutive weeks. Aim 2: The conceptual model of CPAP adherence produced a dynamical system, informed by Model Predictive Control (MPC) as a decision-making algorithm to optimize CPAP use to ≥6hr/night by tailoring actionable behavioral recommendations using patient data integrated in real-time. Results Aim 1: Across the 60-day trial, average daily SleepWell24 engagement was 72.7%. Median CPAP adherence of ≥6hr/night was 65.8%. All participants (100%) rated SleepWell24 as moderately-to-totally acceptable and would recommend it; perceived helpfulness averaged 7.0 (of 10). Eighty percent achieved consistent CPAP use. Aim 2: In simulation, the MPC framework managed CPAP-associated symptoms (e.g., nasal, anxiety, leak) and adjusted CPAP use goals, improving predicted CPAP adherence and sleep duration and quality. Conclusion SleepWell24 was engaging, acceptable, and helpful, with most users reaching optimal CPAP use. We will next estimate dynamical models using data from trial patients, a necessary step towards full automation of SleepWell24. Support (if any) AASMF #285-SR-22
0632 Retrospective Cohort Analysis of Diagnostic Polysomnography to Predict Treatment Response to Hypoglossal Nerve Stimulation in Obstructive Sleep Apnea
Abstract Introduction Hypoglossal nerve stimulators (HGNS) are used in patients with moderate-to-severe obstructive sleep apnea (OSA) who are unable to tolerate or do not respond to continuous positive airway pressure (CPAP) therapy. However, a subgroup of patients fail to achieve resolution of OSA with HGNS alone. Previous studies have shown that lower BMI, lower nadir oxygenation, decreased sleep latency, and higher VOTE score on drug-induced sleep endoscopy (DISE) predict better treatment outcome. We hypothesize that baseline diagnostic polysomnography (PSG) may further predict which patients will achieve successful therapeutic outcome with HGNS therapy. Methods We conducted a retrospective analysis of all adult patients who underwent HGNS implantation at Mayo Clinic Arizona between 2019-2025 and had a pre-implantation diagnostic PSG available for review. Treatment success was defined by Sher Criteria: >50% reduction in post-treatment apnea hypopnea index (AHI) to a final AHI of < 20/hr. Responders met Sher criteria and non-responders did not meet Sher criteria. Demographics, sleep questionnaire results, PSG variables, and VOTE score on DISE were collected and analyzed using Spearman’s rank correlation of reduction in AHI. Results Twenty-three patients (11M/12F, median age: 69[IQR:64,75] years) met inclusion criteria. Median baseline AHI was 24[IQR:19,37]/hr. Median post-implant AHI was 8 [IQR:3, 14]/hr. Responders (n=15, 65%) and non-responders (n=8, 35%) demonstrated median post-implant AHI of 4.5[IQR:2.3,7.3]/hr and 15.7[IQR:12.3,28.5]/hr, respectively. Treatment response was associated with less time with SpO2 < 88% (T88%) (21min [IQR:3,64] vs. 73[IQR:36,105mins]; p=0.023) and higher central apnea index (CAI) (1[IQR:0.1,3] vs. 0[IQR:0,1], p=0.03) on pre-implantation PSG. Conclusion In this small cohort of OSA patients, less nocturnal hypoxemia as defined by T88% and higher baseline central apnea index were predictors of better treatment response to HGNS therapy as measured by Sher criteria. We hypothesize that greater nocturnal hypoxemia likely reflects more severe airway obstruction during sleep. Our analysis also showed that responders had higher baseline CAI than non-responders, however we believe this association is not clinically significant and likely driven by one outlier (CAI 13/hr). Further analysis in a larger HGNS cohort is needed to confirm these findings. Data enrichment efforts and more sophisticated analyses are underway. Support (if any)
The Role of Vaccination in Adult Solid Organ Transplantation: Updated Reviews with Recent Guidelines
Vaccination remains a cornerstone of infection prevention in adult solid organ transplant (SOT) recipients, a population at heightened risk for vaccine-preventable diseases due to chronic immunosuppression and comorbidities. Updated guidelines from the American Society of Transplantation Infectious Diseases Community of Practice (AST IDCOP) and other international bodies emphasize the need for timely and comprehensive vaccination strategies before and after transplantation. This review synthesizes current literature and practice guidelines on vaccination in adult solid organ transplant (SOT) candidates and recipients. Published peer-reviewed studies, clinical trials, and consensus guidelines were evaluated, with emphasis on vaccination timing, safety, immunogenicity, dosing strategies, and serologic response monitoring in the SOT population. Comprehensive vaccination planning before transplantation, combined with appropriate post-transplant booster strategies, remains vital to improving long-term outcomes in SOT recipients. This review provides clinicians with an updated, evidence-based framework for integrating evolving vaccination guidelines into the care of adult transplant patients.
Comparative Analysis of Machine Learning Models for Obstructive Sleep Apnea and Hypopnea Detection Using Pulse Oximetry and Heart Rate Variability
2025 IEEE EMBS International Conference on Biomedical and Health Informatics (BHI) | December 8, 2025 | Volume: No volume available | Issue: No issue available | Pages: 1-7
Abstract Introduction A previously published case report suggested that alcohol might cause false-negative results in home sleep apnea testing (HSAT) utilizing Peripheral Arterial Tonometry (PAT). Alcohol is consumed by nearly a third of people globally. Based on this, along with rapid growth in PAT HSAT utilization, we aimed to prospectively study the interaction between alcohol consumption and PAT HSAT technology. We hypothesized that alcohol use would significantly attenuate sleep disordered breathing metrics in contrast to existing literature suggesting alcohol may exacerbate sleep apnea. Methods We planned to recruit subjects (N=100) from Mayo Clinic Arizona sleep clinic who were being evaluated for sleep-disordered breathing and elected to undergo home sleep apnea testing (WatchPAT ONE). Participants were required to report social alcohol use (no more than 1-3 drinks per day). The first and second home sleep apnea test were conducted on separate nights (night 1: without alcohol; night 2: with alcohol). Patients also completed a questionnaire, detailing their normal alcohol intake as well as intake during the respective sleep tests. Statistical analysis included paired sample t-test as well as a descriptive analysis. Results A total of 75 subjects were recruited (mean age [± SD] 56.8 ± 11.9; 90.7% male; mean BMI 29.8 ± 5.8) and 56 patients completed both sleep tests. The mean apnea hypopnea index (AHI) was not statistically different (p=0.784) between night 1 and night 2 (without alcohol: 19.6/hour ± 21.0; with alcohol: 19.3 ± 21.5, respectively). Similarly, no statistically significant difference was found in the AHI during REM and NREM sleep. Conclusion Preliminary data does not suggest a statistically significant difference in AHI without or with alcohol. While no significant change in AHI was observed, this study highlights the need for further investigation into the impact alcohol may have on PAT technology. Further analyses and data enrichment are underway. Support (if any) Mayo Foundation
1027 Valproic Acid and Central Sleep Apnea: A Retrospective Study
Abstract Introduction Central sleep apnea (CSA) is associated with several medical conditions (e.g., heart failure, atrial fibrillation) and medications (e.g., opioids, ticagrelor, sodium oxybate and valproic acid). We report a case of a 31-year-old female with bipolar disorder treated with valproic acid diagnosed with central sleep apnea on polysomnography, which revealed an apnea-hypopnea index of 150/hour, central apnea index of 112/hour, nadir oxygen saturation of 78%, and 38.6 minutes with oxygen saturation ≤ 88%. Echocardiogram, electrocardiogram, brain magnetic resonance imaging, serum acylcarnitine and serum ammonia levels were unremarkable. Total and free serum valproic acid level was 33 and < 3 mcg/mL, respectively. Two cases of central sleep apnea associated with valproic acid use, both of which improved upon discontinuation of valproic acid, have been reported in the literature. We started the patient on positive airway pressure and suggested she taper off valproic acid and then repeat polysomnography. Given the possible association between central sleep apnea and valproic acid use, we retrospectively analyzed patients receiving valproic acid at time of polysomnography. Methods We retrospectively identified patients between 2005-2017 who were prescribed valproic acid (n=6,169), and of these 72 received valproic acid within 90 days of polysomnography. After chart review, we were able to confirm that 29 received valproic acid at time of polysomnography via blood levels or clear chart documentation. Results Four patients (13.8 %) demonstrated a central apnea index ≥ 5 per hour (mean apnea-hypopnea index 39.2/hour +/- 32.2/ hour including a central apnea index 11.7 +/- 6.6/hour) during polysomnography. Although one patient (3.4 %), a 2-year-old child with Dravet syndrome and refractory/drug resistant generalized epilepsy, was diagnosed clinically with central sleep apnea, the other three patients were diagnosed with obstructive sleep apnea and had other potential reason(s) for the elevated central apnea index (e.g., opioid use as needed for migraines). Conclusion Our case describes a third report of central sleep apnea possibly associated with valproic acid, and our retrospective study indicates that this association is rare. Prospective sleep studies on patients before and after receiving valproic acid are warranted to determine if valproic acid causes central sleep apnea. Support (if any)
0511 High Frequency Radar for Non-Contact Detection of Respiratory Signals During Sleep
Abstract Introduction Polysomnography (PSG) requires on-body sensors for respiratory effort measurement, that can adversely affect sleep quality and accuracy of detection of sleep related breathing disorders (SRBD). We developed a non-contact 60 Hz pulsed wave radar system with integrated advanced signal processing to collect respiratory effort, heart rate and gross body movements data using phase differencing to a sub-mm resolution. In this study we tested the performance of this system in detecting SRBD events against standard PSG in human participants. Methods During participants’ clinically indicated PSG, we collected concurrent data from the radar system placed under the bed on a tripod mount. Algorithms were developed to quantify breath amplitude reductions collected by radar and compared to the time-synced signals derived from respiratory impedance plethysmography belts. A Convolutional Neural Network (CNN) was trained on radar in-phase/quadrature (I/Q) data for each 30 second epoch to output probability of apnea and hypopnea events using standard event definitions. Receiver Operating Characteristics (ROC) plot and confusion matrix for the trained network were generated to provide accuracy of event predictions. Results A total of 60 participants completed the study. The participants had a mean age of 65 years (Inter Quartile Range 13.5 years), and 56% subjects were male. The mean AHI for the entire cohort was 12.9 (IQR 14.75) events/hour. ROC plots showed an Area Under the Curve (AUC) of 0.98 for events detection by radar compared to human scored PSGs. The confusion matrix was generated at an operating point of 95% sensitivity and 80% specificity. Conclusion The non-contact high frequency radar system showed excellent performance in respiratory event detection in patients with sleep-related breathing disorders in comparison to the gold standard PSG system. Use of this technology is expected to reduce the number of body contact sensors used during conventional sleep studies and thus improve patient comfort and accuracy of results. Support (if any) Research reported in this abstract was supported by National Institute of Aging of the NIH under award number: R44AG060779
0611 Gamification of Digital Oropharyngeal Exercises Improves Therapy Adherence in OSA Patients
Abstract Introduction OSA is caused by the interaction of impaired upper airway anatomy and dysfunctional upper airway muscle response to airway narrowing during sleep. Oropharyngeal exercises focused on training upper airway muscles are effective in reducing OSA severity and symptoms. However, similar to other physical therapy programs, oropharyngeal exercises require patients to complete multiple therapy sessions which affects patient compliance. To address this, we developed a smartphone application to provide oropharyngeal exercise and tested the effect of adding gamification and habit formation techniques on therapy adherence. Methods The experimental app which included oropharyngeal exercise therapy administered using voice-controlled games, a reward system, a reminder system, and supportive video content was compared to the control app that included text-based exercise therapy instructions and limited video content. Participants with mild to moderate OSA were randomly assigned (1:1) to either group. Demographics, sleep apnea variables, therapy progress, self-reported snoring severity questionnaires were collected for both groups. Appropriate descriptive statistics were used to summarize baseline and outcome data. Results 30 participants (13 male), mean age 60.7 ± 11.1 years were randomized equally to the experimental and control groups. 9 participants (6 in the experimental group and 3 in the control group) were unable to complete the study due to technical challenges with the apps and were excluded from analysis. No statistically significant differences were noted in either group’s baseline demographic and OSA measures. 7/9 (78%) participants in the experimental group vs 7/12 (58%) in the control group met the prespecified compliance thresholds for the 8 weeks therapy period. Self-reported snoring severity mean scores were significantly reduced in the experimental group (from 2.86 to 1.43, p-value 0.04) compared to the control group (from 2.14 to 1.77, p-value 0.21). Conclusion Addition of gamification and therapy monitoring techniques improve compliance to the prescribed oropharyngeal exercises in patients with OSA. Further studies are needed to establish the efficacy of gamified oropharyngeal therapy in the treatment of OSA. Support (if any) Research reported in this abstract was supported by NHLBI of the NIH under award number: R43HL152948-01.
Hospitalization risk with undiagnosed OSA in older adults with cardiovascular diseaseCommentary on Kirk J, Wickwire EM, Somers VK, Johnson DA, Albrecht JS. Undiagnosed obstructive sleep apnea increases risk of hospitalization among a racially diverse group