Citations

Clear

6 citation(s) found for "Finn, Paul".

SPIROMICS HF: Rationale, Design, and Reproducibility of Measures
Barr, R. Graham , Lima, João A.C. , Prince, Martin R. , Abraham, Theodore P. , Agarwal, Prachi , Arora, Garima , Balasubramanian, Aparna , Barjaktarević, Igor , Bello, Natalie A. , Carr, James C. , Cooper, Christopher B. , Finn, J. Paul , Freed, Benjamin H. , Hansel, Nadia N. , Hsu, Jeffrey J. , Kitzman, Dalane W. , LaBounty, Troy , Lee, Yoo Jin , Liu, Jing , Lloyd, Steven G. , Markl, Michael , Ortega, Victor E. , Paine, Robert , Peters, Stephen P. , Schroeder, Joyce , Shepshelovich, Daniel , Sun, Yifei , Wells, J. Michael , Wieben, Oliver , Woodruff, Prescott G. , Ambale-Venkatesh, Bharath , Agarwal, Prachi P , Arora, Garima , Balasubramanian, Aparna , Barjaktarevic, Igor , Bello, Natalie A , Bluemke, David A , Budoff, Matthew , Carr, James C , Chaudhuri, Dipayan , Cooper, Christopher B , Couper, David , Finn, J Paul , Freed, Benjamin H , Han, MeiLan King , Hansel, Nadia N , Hsu, Jeffrey J , Kitzman, Dalane W , Krishnan, Jerry A , LaBounty, Troy M , Lee, Yoo Jin , Liu, Jing , Lloyd, Steven G , Mukherjee, Monica , Beussink-Nelson, Lauren , Ohar, Jill , Paine, Robert , Schroeder, Joyce D , Shen, Wei , Sun, Yifei , Vogel-Claussen, Jens , Watson, Karol E. , Wells, J Michael , Wieben, Oliver , Woodruff, Prescott G , Shah, Sanjiv J , Markl, Michael , Barr, R. Graham , Bluemke, David A. , Budoff, Matthew J. , Couper, David , Mukherjee, Monica , Vogel‐Claussen, Jens

Mayo Clinic

Circulation: Heart Failure | November 5, 2025 | Volume: 18 | Issue: 12 | Pages: No page available

10.1161/circheartfailure.125.012833 | PMID 41190426 Get It

BACKGROUND: Although chronic obstructive pulmonary disease (COPD) and heart failure with preserved ejection fraction often coexist with overlapping clinical features, they are usually studied separately. The SPIROMICS HF (Subpopulations and Intermediate Outcome Measures in COPD and Heart Failure Study) is testing hypotheses that new computed tomography emphysema subtypes are associated with specific cardiovascular phenotypes (eg, cor pulmonale , cor pulmonale parvus ), common airway branch variants are associated with right heart dysfunction, and symptomatic tobacco-exposed persons with preserved spirometry have signs of increased left ventricular afterload. METHODS: SPIROMICS is a multicenter observational study of COPD with extensive pulmonary phenotyping of participants with ≥20 pack-years smoking and nonsmoking controls. COPD and COPD severity were defined by standard spirometric criteria and symptomatic tobacco-exposed persons with preserved spirometry by ≥20 pack-years, normal spirometry, and COPD Assessment Test score >10. SPIROMICS HF selected all participants in SPIROMICS visit 5 at major sites. Its comprehensive speckle-tracking echocardiography, which included physiological perturbations of leg raise and low-intensity exercise, was harmonized prospectively with the Multi-Ethnic Study of Atherosclerosis Early Heart Failure and HeartSHARE (Combining Omics, Deep Phenotyping, and Electronic Health Records for Heart Failure Subtypes and Treatment Targets) studies. The cardiopulmonary magnetic resonance imaging protocol with gadolinium administration included myocardial fibrosis sequences, pulmonary angiography, time-resolved 3-dimensional cine magnetic resonance imaging (4-dimensional flow) of venous return, and metronome-paced tachypnea to induce dynamic hyperinflation. Coronary artery calcium was assessed on computed tomography scans. The Kansas City Cardiomyopathy Questionnaire was administered. RESULTS: Of the final sample of 753 participants, 57% had COPD (15% mild, 27% moderate, and 15% severe), 18% had symptomatic tobacco-exposed persons with preserved spirometry, 16% were smoking controls, and 8% were nonsmoking controls. Reproducibility of the main measures from speckle-tracking echocardiography (intraclass correlation coefficient, 0.83–0.99), exercise echocardiography (intraclass correlation coefficient, 0.71–0.99) and magnetic resonance imaging (intraclass correlation coefficient, 0.57–0.99) were good-to-excellent, including in severe COPD. CONCLUSIONS: SPIROMICS HF aims to characterize and understand cardiopulmonary interactions in COPD and COPD-related phenotypes to inform targeted treatments for combined cardiopulmonary failure.
MR Angiography Series: Noncardiac Chest MR Angiography
François, Christopher J. , Hecht, Elizabeth M. , Roditi, Giles , Finn, J. Paul , François, Christopher , Finn, J Paul

Mayo Clinic

RadioGraphics | February 18, 2022 | Volume: 42 | Issue: 2 | Pages: E48-E49

10.1148/rg.210212 | PMID 35179985 Get It

A standard system phantom for magnetic resonance imaging
Stupic, Karl F. , Ainslie, Maureen, Boss, Michael A. , Charles, Cecil, Dienstfrey, Andrew , Evelhoch, Jeffrey L., Finn, Paul, Gimbutas, Zydrunas , Gunter, Jeffrey L. , Hill, David , Karaulanov, Todor , Liu, Guoying , Martin, Michele N. , Prasad, Pottumarthi V. , Rentz, Nikki S., Yuan, Chun , Keenan, Kathryn E , Yuan, Chun , Russek, Stephen E , Boss, Michael A , Jack, Clifford R. , Jackson, Edward F. , Keenan, Kathryn E. , Russek, Stephen E.

Mayo Clinic

Magnetic Resonance in Medicine | April 13, 2021 | Volume: 86 | Issue: 3 | Pages: 1194-1211

10.1002/mrm.28779 | PMID 33847012 Get It

Purpose A standard MRI system phantom has been designed and fabricated to assess scanner performance, stability, comparability and assess the accuracy of quantitative relaxation time imaging. The phantom is unique in having traceability to the International System of Units, a high level of precision, and monitoring by a national metrology institute. Here, we describe the phantom design, construction, imaging protocols, and measurement of geometric distortion, resolution, slice profile, signal‐to‐noise ratio (SNR), proton‐spin relaxation times, image uniformity and proton density. Methods The system phantom, designed by the International Society of Magnetic Resonance in Medicine ad hoc committee on Standards for Quantitative MR, is a 200 mm spherical structure that contains a 57‐element fiducial array; two relaxation time arrays; a proton density/SNR array; resolution and slice‐profile insets. Standard imaging protocols are presented, which provide rapid assessment of geometric distortion, image uniformity, T 1 and T 2 mapping, image resolution, slice profile, and SNR. Results Fiducial array analysis gives assessment of intrinsic geometric distortions, which can vary considerably between scanners and correction techniques. This analysis also measures scanner/coil image uniformity, spatial calibration accuracy, and local volume distortion. An advanced resolution analysis gives both scanner and protocol contributions. SNR analysis gives both temporal and spatial contributions. Conclusions A standard system phantom is useful for characterization of scanner performance, monitoring a scanner over time, and to compare different scanners. This type of calibration structure is useful for quality assurance, benchmarking quantitative MRI protocols, and to transition MRI from a qualitative imaging technique to a precise metrology with documented accuracy and uncertainty.
Quantitative magnetic resonance imaging phantoms: A review and the need for a system phantom
Keenan, Kathryn E. , Ainslie, Maureen, Barker, Alex J. , Boss, Michael A. , Cecil, Kim M. , Charles, Cecil, Chenevert, Thomas L. , Clarke, L., Evelhoch, Jeffrey L., Finn, Paul, Gembris, Daniel, Gunter, Jeffrey L. , Hill, David , Jack, Clifford R. , Liu, Guoying , Sharma, Samir D. , Steckner, Michael , Stupic, Karl F. , Trzasko, Joshua D. , Yuan, Chun , Zheng, Jie , Jack, Clifford R , Barker, Alex J , Keenan, Kathryn E , Boss, Michael A , Jackson, Edward F. , Russek, Stephen E.

Mayo Clinic

Magnetic Resonance in Medicine | October 30, 2017 | Volume: 79 | Issue: 1 | Pages: 48-61

10.1002/mrm.26982 | PMID 29083101 Get It

The MRI community is using quantitative mapping techniques to complement qualitative imaging. For quantitative imaging to reach its full potential, it is necessary to analyze measurements across systems and longitudinally. Clinical use of quantitative imaging can be facilitated through adoption and use of a standard system phantom, a calibration/standard reference object, to assess the performance of an MRI machine. The International Society of Magnetic Resonance in Medicine AdHoc Committee on Standards for Quantitative Magnetic Resonance was established in February 2007 to facilitate the expansion of MRI as a mainstream modality for multi‐institutional measurements, including, among other things, multicenter trials. The goal of the Standards for Quantitative Magnetic Resonance committee was to provide a framework to ensure that quantitative measures derived from MR data are comparable over time, between subjects, between sites, and between vendors. This paper, written by members of the Standards for Quantitative Magnetic Resonance committee, reviews standardization attempts and then details the need, requirements, and implementation plan for a standard system phantom for quantitative MRI. In addition, application‐specific phantoms and implementation of quantitative MRI are reviewed. Magn Reson Med 79:48–61, 2018. © 2017 International Society for Magnetic Resonance in Medicine.