Citations

Clear

11 citation(s) found for "Feng, Xue".

Multimodal Slice Interaction Network Enhanced by Transfer Learning for Precise Segmentation of Internal Gross Tumor Volume in Lung Cancer PET/CT Imaging
Luo, Yi , Guo, Yike, Zhang, Rui , Ngwa, Wil, Zhou, Zongwei, Ding, Kai , Hooshangnejad, Hamed , Feng, Xue, Chen, Quan , Ngwa, Wilfred , Zhou, Zongwei , Ding, Kai

Mayo Clinic

2026 IEEE 14th International Conference on Healthcare Informatics (ICHI) | August 12, 2026 | Volume: No volume available | Issue: No issue available | Pages: 525-534

10.1109/ichi69079.2026.00072 Get It

Hybrid Curriculum Learning for Data-Efficient Lung Nodule Detection with YOLOv11
Luo, Yi , Guo, Yike, Hooshangnejad, Hamed , Feng, Xue , Chen, Quan, Zhou, Zongwei , Chen, Yaxi , Hu, Yipeng, Zhang, Rui, Ding, Kai , Feng, Xue , Ding, Kai , Zhou, Zongwei

Mayo Clinic

Diagnostics | May 11, 2026 | Volume: 16 | Issue: 10 | Pages: 1441

10.3390/diagnostics16101441 | PMID 42196807 Get It

Background/Objectives: Accurate detection of pulmonary nodules on chest CT is critical for lung cancer screening, yet training robust detectors remains challenging due to the high cost of reliable annotations. In this work, we present a systematic study of curriculum learning for CT-based lung nodule detection on the enhanced LUNA25 benchmark and propose a hybrid curriculum learning framework for data-efficient optimization. Methods: Our approach estimates sample difficulty by fusing clinically interpretable handcrafted factors such as nodule size and count with model-driven signals such as prediction confidence from a teacher model, and constructs a three-stage progressive training curriculum from easy to hard samples. Using YOLOv11s as a strong baseline, the proposed hybrid curriculum is compared against conventional training without curriculum learning and against single-source curricula. Results: On the held-out LUNA25 test set, hybrid curriculum learning increases mAP50 from 0.672 to 0.696, mAP50–95 from 0.369 to 0.385, recall from 0.588 to 0.634, and precision from 0.725 to 0.764. Extensive data-efficiency experiments with proportional reductions (1/2, 1/5, 1/10) and fixed training samples (5000–40,000 slices) further confirm consistent gains across limited-data regimes. Conclusions: These results demonstrate that jointly leveraging intrinsic image complexity and optimization-aware feedback provides effective sample scheduling for robust and data-efficient lung nodule detection.
Multiscale Segmentation-Guided Diffusion Model for CBCT-to-CT Synthesis
Guo, Yike, Luo, Yi , Hooshangnejad, Hamed , Zhang, Rui , Feng, Xue , Chen, Quan , Ngwa, Wilfred , Ding, Kai , Chen, Quan , Feng, Xue , Ding, Kai , Guo, Yike

Mayo Clinic

Life | December 8, 2025 | Volume: 15 | Issue: 12 | Pages: 1871

10.3390/life15121871 | PMID 41465810 Get It

To improve synthetic CT (sCT) generation from cone-beam CT (CBCT) in radiotherapy, we propose a multiscale segmentation-guided diffusion framework. The proposed model integrates anatomical priors across multiple spatial resolutions through a segmentation mask pyramid and introduces a scale-specific loss function to guide learning at each level. When evaluated on the SynthRAD2023 brain dataset, our model achieves a mean absolute error (MAE) of 61.82 HU, a peak signal-to-noise ratio (PSNR) of 32.05 dB, and a structural similarity index (SSIM) of 0.90, outperforming baseline models. These results suggest that multiscale anatomical guidance can improve the fidelity and anatomical consistency of sCT images, thus facilitating high-quality CBCT-to-CT translation in radiotherapy applications.
Deep Learning for CT Synthesis in Radiotherapy
Guo, Yike, Luo, Yi , Hooshangnejad, Hamed , Zhang, Rui , Feng, Xue , Chen, Quan , Ngwa, Wilfred , Ding, Kai , Chen, Quan , Feng, Xue , Ding, Kai , Guo, Yike

Mayo Clinic

Bioengineering | November 25, 2025 | Volume: 12 | Issue: 12 | Pages: 1297

10.3390/bioengineering12121297 | PMID 41463594 Get It

With the rapid development of artificial intelligence (AI), various deep learning (DL) methods have been introduced into radiation oncology. Among them, the generation of synthetic Computed Tomography (sCT) images has attracted increasing attention, as it supports different clinical scenarios, from image-guided adaptive radiotherapy (IGART) to the simulation-free workflow. This review provides a comprehensive overview of recent studies on DL-based sCT synthesis in radiotherapy from multiple imaging modalities, including Cone-Beam CT (CBCT), Magnetic Resonance Imaging (MRI), and diagnostic CT, and discusses their clinical applications in CBCT-based online adaptive radiotherapy, MRI-guided radiotherapy, and simulation-free workflows. We also examine the architectures of representative DL models such as convolutional neural networks (CNNs) and generative adversarial networks (GANs) and summarize emerging training strategies. Finally, we discuss current challenges of clinical translation of DL algorithms into clinical practice and suggest potential directions for future research. Overall, this paper highlights the potential of AI-driven sCT generation to advance treatment planning by reducing imaging burden, improving dose accuracy, and accelerating workflow efficiency, thus ultimately improving the treatment outcome of patient care.
A Language Vision Model Approach for Automated Tumor Contouring in Radiation Oncology
Luo, Yi , Hooshangnejad, Hamed , Feng, Xue , Huang, Gaofeng , Chen, X. R. , Zhang, Rui , Chen, Quan , Ngwa, Wil, Ding, Kai , Chen, Quan , Chen, Xiaojian , Feng, Xue , Ding, Kai , Ngwa, Wilfred

Mayo Clinic

Bioengineering | August 7, 2025 | Volume: 12 | Issue: 8 | Pages: 835

10.3390/bioengineering12080835 | PMID 40868348 Get It

Background: Lung cancer ranks as the leading cause of cancer-related mortality worldwide. The complexity of tumor delineation, crucial for radiation therapy, requires expertise often unavailable in resource-limited settings. Artificial Intelligence (AI), particularly with advancements in deep learning (DL) and natural language processing (NLP), offers potential solutions yet is challenged by high false positive rates. Purpose: The Oncology Contouring Copilot (OCC) system is developed to leverage oncologist expertise for precise tumor contouring using textual descriptions, aiming to increase the efficiency of oncological workflows by combining the strengths of AI with human oversight. Methods: Our OCC system initially identifies nodule candidates from CT scans. Employing Language Vision Models (LVMs) like GPT-4V, OCC then effectively reduces false positives with clinical descriptive texts, merging textual and visual data to automate tumor delineation, designed to elevate the quality of oncology care by incorporating knowledge from experienced domain experts. Results: The deployment of the OCC system resulted in a 35.0% reduction in the false discovery rate, a 72.4% decrease in false positives per scan, and an F1-score of 0.652 across our dataset for unbiased evaluation. Conclusions: OCC represents a significant advance in oncology care, particularly through the use of the latest LVMs, improving contouring results by (1) streamlining oncology treatment workflows by optimizing tumor delineation and reducing manual processes; (2) offering a scalable and intuitive framework to reduce false positives in radiotherapy planning using LVMs; (3) introducing novel medical language vision prompt techniques to minimize LVM hallucinations with ablation study; and (4) conducting a comparative analysis of LVMs, highlighting their potential in addressing medical language vision challenges.
Improving the Precision of Deep-Learning-Based Head and Neck Target Auto-Segmentation by Leveraging Radiology Reports Using a Large Language Model
Zhu, Libing , Rwigema, Jean‐Claude M. , Feng, Xue , Ansari, Bilaal, Duan, Jingwei , Rong, Yi , Chen, Quan , Chen, Quan , Rong, Yi , Feng, Xue , Duan, Jingwei , Ansari, Bilaal

Mayo Clinic

Cancers | June 10, 2025 | Volume: 17 | Issue: 12 | Pages: 1935

10.3390/cancers17121935 | PMID 40563585 Get It

Background/Objectives: The accurate delineation of primary tumors (GTVp) and metastatic lymph nodes (GTVn) in head and neck (HN) cancers is essential for effective radiation treatment planning, yet remains a challenging and laborious task. This study aims to develop a deep-learning-based auto-segmentation (DLAS) model trained on external datasets with false-positive elimination using clinical diagnosis reports. Methods: The DLAS model was trained on a multi-institutional public dataset with 882 cases. Forty-four institutional cases were randomly selected as the external testing dataset. DLAS-generated GTVp and GTVn were validated against clinical diagnosis reports to identify false-positive and false-negative segmentation errors using two large language models: ChatGPT-4 and Llama-3. False-positive ruling out was conducted by matching the centroids of AI-generated contours with the slice locations or anatomical regions described in the reports. Performance was evaluated using the Dice similarity coefficient (DSC), 95th percentile Hausdorff distance (HD95), and tumor detection precision. Results: ChatGPT-4 outperformed Llama-3 in accurately extracting tumor locations from the diagnostic reports. False-positive contours were identified in 15 out of 44 cases. The DSCmean of the DLAS contours for GTVp and GTVn increased from 0.68 to 0.75 and from 0.69 to 0.75, respectively, after the ruling-out process. Notably, the average HD95 value for GTVn decreased from 18.81 mm to 5.2 mm. Post ruling out, the model achieved 100% precision for GTVp and GTVn when compared with the results of physician-determined contours. Conclusions: The false-positive ruling-out approach based on diagnostic reports effectively enhances the precision of DLAS in the HN region. The model accurately identifies the tumor location and detects all false-negative errors.
EXACT-Net: Framework for EHR-Guided Lung Tumor Auto-Segmentation for Non-Small Cell Lung Cancer Radiotherapy
Kelly, Katelyn, Feng, Xue , Luo, Yi , Zhang, Rui , Xu, Ziyue , Chen, Quan , Ding, Kai , Chen, Quan , Huang, Gaofeng , Feng, Xue , Xu, Ziyue , Ding, Kai , Hooshangnejad, Hamed , Huang, Gaofeng , Kelly, Katelyn

Mayo Clinic

Cancers | December 9, 2024 | Volume: 16 | Issue: 23 | Pages: 4097

10.3390/cancers16234097 | PMID 39682283 Get It

Background/Objectives: Lung cancer is a devastating disease with the highest mortality rate among cancer types. Over 60% of non-small cell lung cancer (NSCLC) patients, accounting for 87% of lung cancer diagnoses, require radiation therapy. Rapid treatment initiation significantly increases the patient’s survival rate and reduces the mortality rate. Accurate tumor segmentation is a critical step in diagnosing and treating NSCLC. Manual segmentation is time- and labor-consuming and causes delays in treatment initiation. Although many lung nodule detection methods, including deep learning-based models, have been proposed. Most of these methods still have a long-standing problem of high false positives (FPs). Methods: Here, we developed an electronic health record (EHR)-guided lung tumor auto-segmentation called EXACT-Net (EHR-enhanced eXACtitude in Tumor segmentation), where the extracted information from EHRs using a pre-trained large language model (LLM) was used to remove the FPs and keep the TP nodules only. Results: The auto-segmentation model was trained on NSCLC patients’ computed tomography (CT), and the pre-trained LLM was used with the zero-shot learning approach. Our approach resulted in a 250% boost in successful nodule detection using the data from ten NSCLC patients treated in our institution. Conclusions: We demonstrated that combining vision-language information in EXACT-Net multi-modal AI framework greatly enhances the performance of vision only models, paving the road to multimodal AI framework for medical image processing.
Baduanjin for ischemic heart failure with mildly reduced/preserved ejection fraction (BEAR Trial): A randomized controlled trial
Li, Jingen , Yu, Meili, Wang, Yanhui , Li, Siming , Li, Siwei , Feng, Xue , Li, R.K. , Chen, Keji , Xu, Hao , Li, Jingen , Li, Ruijie

Mayo Clinic

Journal of Evidence-Based Medicine | July 6, 2024 | Volume: 17 | Issue: 3 | Pages: 526-534

10.1111/jebm.12631 | PMID 38970325 Get It

AbstractAimWhile Baduanjin, a traditional Chinese mind‐body exercise, has shown potential health benefits, its efficacy in improving outcomes for heart failure patients with mildly reduced or preserved ejection fraction (HFmrEF/HFpEF) has not been well documented. We aimed to investigate the adjunctive impact of Baduanjin on exercise capacity and quality of life for HFmrEF/HFpEF.MethodsPatients with HFmrEF/HFpEF were enrolled in this multicenter randomized clinical trial. All participants were randomized to conventional cardiac rehabilitation with or without an additional 12‐week Baduanjin exercise. The primary endpoint was the distance covered in a 6‐min walk test (6MWD), while key secondary outcomes included quality of life measured by the Minnesota Living with Heart Failure Questionnaire (MLHFQ) and cardiopulmonary function including anaerobic threshold (VO2 AT).ResultsA total of 120 patients were enrolled, and 109 completed all session and tests. The mean age of the 120 patients was 60.5 years (SD, 9.21 years), and 23 (19.2%) were women. The Baduanjin group exhibited a 6.14% improvement in 6MWD compared to a 1.32% improvement in the control group (median improvement, 25.0 vs. 5.0 m; p < 0.001) at 12th week. The VO2 AT increased by 25.87% in the Baduanjin group versus 3.94% in the control group (p < 0.001). Quality of life also significantly improved in the Baduanjin group as indicated by MLHFQ score changes (–16.8% vs. –3.99%; p < 0.001).ConclusionsAdding Baduanjin to exercise‐based cardiac rehabilitation for patients with ischemic HFmrEF or HFpEF are generally safe and could provide significant improvements in exercise capacity and quality of life.
Metastatic non-small cell lung cancer (NSCLC) and brain edema: a topographical and clinicopathological investigation utilizing deep learning-based artificial intelligence (DLBAI)
Yun, Jonathan , Kurker, Kristina P. , Kumar, Jeyan S. , Sutherland, Grant , Farzad, Faraz, Sukumar, Rohit , Yener, Ulaş, Patel, Sohil H. , Schiff, David , Lopes, Beatriz, Mut, Melike , Maragkos, Georgios Α. , Feng, Xue

Mayo Clinic

No container title available | January 19, 2024 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.21203/rs.3.rs-3851661/v1 Get It

Abstract Tumor-associated vasogenic brain edema is a well-known contributor of morbidity and mortality in patients with metastatic disease to the brain. It is widely accepted that brain metastases (BM) is associated with extensive edema and can cause increased symptomatology such as pain, neurologic deficit, and elevated intracranial pressure depending on extent and location. We present a proof-of-concept retrospective analysis utilizing DLBAI to segment and detect radiological and topographical patterns of peritumoral edema and assess for clinicopathological correlates in 84 patients with NSCLC and BM who underwent surgical resection and were not previously on steroids. We found that overall, tumors in all locations demonstrated a mean 10:1 edema to tumor ratio (ETR) and an occipital tumor location was associated with a significantly elevated ETR. Within our cohort there were no other factors that were significantly associated with ETR. This study demonstrates a proof-of-concept that DLBAI is an efficient and accurate method of radiographic analysis that can be applied to detect and potentially predict clinicopathological data and prognostic determinants. Clinically, we demonstrate that NSCLC is associated with significant peritumoral edema and that topographical factors may be associated with increased extent of edema.
Contour subregion error detection methodology using deep learning auto‐segmentation
Duan, Jingwei , Bernard, Mark E. , Castle, J. , Johnson, Jeremiah D. , Chen, Quan , Duan, Jingwei , Rong, Yi , Feng, Xue

Mayo Clinic

Medical Physics | October 4, 2023 | Volume: 50 | Issue: 11 | Pages: 6673-6683

10.1002/mp.16768 | PMID 37793103 Get It

AbstractBackgroundInaccurate manual organ delineation is one of the high‐risk failure modes in radiation treatment. Numerous automated contour quality assurance (QA) systems have been developed to assess contour acceptability; however, manual inspection of flagged cases is a time‐consuming and challenging process, and can lead to users overlooking the exact error location.PurposeOur aim is to develop and validate a contour QA system that can effectively detect and visualize subregional contour errors, both qualitatively and quantitatively.Methods/MaterialsA novel contour subregion error detection (CSED) system was developed using subregional surface distance discrepancies between manual and deep learning auto‐segmentation (DLAS) contours. A validation study was conducted using a head and neck public dataset containing 339 cases and evaluated according to knowledge‐based pass criteria derived from a clinical training dataset of 60 cases. A blind qualitative evaluation was conducted, comparing the results from the CSED system with manual labels. Subsequently, the CSED‐flagged cases were re‐examined by a radiation oncologist.ResultsThe CSED system could visualize the diverse types of subregional contour errors qualitatively and quantitatively. In the validation dataset, the CSED system resulted in true positive rates (TPR) of 0.814, 0.800, and 0.771; false positive rates (FPR) of 0.310, 0.267, and 0.298; and accuracies of 0.735, 0.759, and 0.730, for brainstem and left and right parotid contours, respectively. The CSED‐assisted manual review caught 13 brainstem, 19 left parotid, and 21 right parotid contour errors missed by conventional human review. The TPR/FPR/accuracy of the CSED‐assisted manual review improved to 0.836/0.253/0.784, 0.831/0.171/0.830, and 0.808/0.193/0.807 for each structure, respectively. Further, the time savings achieved through CSED‐assisted review improved by 75%, with the time for review taking 24.81 ± 12.84, 26.75 ± 10.41, and 28.71 ± 13.72 s for each structure, respectively.ConclusionsThe CSED system enables qualitative and quantitative detection, localization, and visualization of manual segmentation subregional errors utilizing DLAS contours as references. The use of this system has been shown to help reduce the risk of high‐risk failure modes resulting from inaccurate organ segmentation.