Citations

Clear

5 citation(s) found for "Dowling, Brittany".

Effects of Mound Versus Flat-Ground Pitching and Distance on Arm Mechanics and Elbow Torque in High School Pitchers
Dowling, Brittany , Mcelheny, Kathryn, Ling, Daphne I. , Camp, Christopher L. , Dines, Joshua S.

Mayo Clinic

Orthopaedic Journal of Sports Medicine | December 10, 2020 | Volume: 8 | Issue: 12 | Pages: No page available

10.1177/2325967120969245 | PMID 33354584 Get It

Background: Although the monitoring of a pitcher’s throwing arm workload has become a hot topic in both research and the pitching world, the impact of mound height and distance still remains unclear. Purpose: To compare the kinetics and kinematics between pitches from a mound and flat ground at 2 different distances. Study Design: Descriptive laboratory study. Methods: A total of 21 healthy high school varsity baseball pitchers (age, 16.2 ± 1.3 years; weight, 73.6 ± 11.0 kg; height, 181.3 ± 6.4 cm) participated in this study. Players were fitted with a motusBASEBALL sensor and sleeve. Each pitcher was instructed to pitch 5 fastballs under 4 conditions: mound at 60.5 ft (regulation distance), flat ground at 60.5 ft, mound at 50.5 ft, and flat ground at 50.5 ft. Linear mixed-effects models were used to account for both intra- and interplayer variability. A multivariable model was used to evaluate the association of mound pitching, flat-ground pitching, and their distances (50.5 ft and 60.5 ft), and their interaction to arm speed, arm slot, arm rotation, elbow varus torque, and ball velocity. Results: There were no statistically significant effects of mound, flat-ground, or distance variation on arm speed or shoulder rotation. Arm slot was significantly higher (+3.0°; P = .02) on pitches from the mound at 60.5 ft compared with 50.5 ft. Elbow varus torque was lower (–1.5 N·m; P = .02) on mound pitches at 60.5 ft compared with 50.5 ft. Pitches thrown from the mound displayed significantly faster ball velocity compared with flat-ground pitches at both distances ( P < .01 for both), with pitches at 60.5 ft having higher velocity (+0.7 m/s; P < .01). Conclusion: Contrary to long-standing notions, the study results suggest that pitching from the mound does not significantly increase stress on the elbow compared with flat-ground pitching. Lower elbow varus torque and faster ball velocity at the regulation distance compared with the reduced distance indicate that elbow stress and ball velocity may not correlate perfectly, and radar guns may not be an appropriate surrogate measure of elbow varus torque. Clinical Relevance: A better understanding of the kinetic and kinematic implications of various throwing programs will allow for the designing of programs that are driven by objective data with aims directed toward injury prevention and rehabilitation in baseball pitchers.
Flat Ground Throwing Results in Decreased Ball Velocity and Increased Elbow Torque Compared to Mound Throwing
Mcelheny, Kathryn, Ling, Daphne I. , Camp, Christopher L. , Dowling, Brittany , Dines, Joshua S.

Mayo Clinic

Orthopaedic Journal of Sports Medicine | July 29, 2019 | Volume: 7 | Issue: 7_suppl5 | Pages: No page available

10.1177/2325967119s00364 Get It

Objectives: The incidence of shoulder and elbow overuse injury continues to rise in youth baseball players. Several throwing programs designed to reduce stress on the elbow have been described, but most are not evidence-based. The aim of this study was to compare the kinetics and kinematics between mound and flat-ground pitching at two different distances with the goal of developing evidenced-based injury prevention and recovery guidelines for youth throwers. Methods: Fifteen healthy, high school varsity-level baseball pitchers (mean age 16.7 ± 0.7 yrs; height 182.2 ± 6.2 cm; weight 76.0 ± 9.4 kg;) participated in the study. Players were fitted with a motusBASEBALLTM sensor and sleeve (Motus Global, Rockville Centre, NY), which has been shown to have good reliability and correlation with in-laboratory measures. Each pitcher was asked to pitch 5 fastballs to a catcher under each of the 4 conditions: mound at 60.5 ft (regulation distance), flat ground at 60.5 ft, mound at 50.5 ft, and flat ground at 50.5 ft. For each pitch, the sensor recorded arm speed, arm slot, shoulder rotation, and elbow varus torque. Ball velocity was tracked with a radar gun (Stalker Radar, Richardson, TX). Linear mixed-effects models were used to account for both within and between-subject variability. A multivariable model was used to evaluate the association of mound pitching (vs flat ground), distance (50.5 vs 60.5 ft), and their interaction on each of the following outcomes: arm speed, arm slot, shoulder rotation, elbow varus torque, and ball velocity. Results: There were no statistically significant effects of mound vs flat ground or distance variation on both arm speed or shoulder rotation. Arm slot was significantly higher on pitches from the mound at 60.5 ft [+4.58 (95% CI: 1.26, 7.90), p=0.007]. Elbow varus torque was significantly lower on throws from the mound [-1.88 (95% CI: -3.56, -0.20), p=0.03] and from a longer distance [-2.21 (95% CI: -3.89, -0.53), p=0.01]. Pitches thrown from the mound were significantly faster compared to flat ground at both distances, with throws at 60.5 ft of greater velocity than at 50.5 ft [+1.03 (95% CI: 0.66, 1.40), p<0.001]. Please see the Table for full results. Conclusion: The findings suggest that throwing from the mound may not be higher risk compared to flat ground, contrary to long-standing notions. The lower elbow varus torque and higher arm slot, which has previously been shown to be associated with reduced stress, from throwing from the mound may even indicate a protective effect. Compared to 50.5 ft, there was lower elbow varus torque and faster ball velocity at the longer distance, indicating that elbow stress and ball velocity may not correlate perfectly, and radar guns may not be an appropriate surrogate measure of elbow varus torque. A better understanding of the kinetic and kinematic implications of various throwing programs will allow for designing programs that are based on objective data to achieve the goal of preventing injuries in young baseball players. [Table: see text]
Application of Kaizen Principles to a Large Cochlear Implant Practice: A Continuous Quality Improvement Initiative at Mayo Clinic
Sladen, Douglas P. , Olund, Amy P., Schmitt, Matthew, Benson, Barbara J., DeJong, Melissa D., Dowling, Brittany P., Carlson, Matthew L. , Benson, Barbara, Schmitt, Matthew, Benson, Barbara

Mayo Clinic

Otology & Neurotology | May 25, 2019 | Volume: 40 | Issue: 6 | Pages: e592-e599

10.1097/mao.0000000000002246 | PMID 31135666 Get It

Objective: To remove barriers and improve access for patients seeking cochlear implantation. Study Design: Prospective quality improvement study at a large tertiary academic care center. Methods: A Kaizen quality improvement model was applied over the course of a year. Four weeklong meetings were used to identify areas for improvement and remediation. Data were collected at baseline, 90-days, and 1-year postcompletion of the project. Outcome measures included lead times, defined as the wait time between first contact with the clinic and the first appointment, and the wait time between surgery and activation, and cycle times defined as the total test time needed to determine cochlear implant candidacy, and total time needed to complete initial activation. The total inventory kept as clinic stock was also calculated Results: Kaizen team members collected data for each outcome measure. After the Kaizen principles were applied, the following outcomes were observed: median lead times between first contact with the clinic to candidacy testing, candidacy testing to surgery, and surgery to activation of the implant remained stable from baseline to 1-year follow-up. Median cycle time for candidacy testing decreased from 7.3 hours at baseline to 3.0 hours at 1-year follow-up. Cycle times for initial activation of the device did not change over time. The total inventory of clinic stock was reduced by 31%. Conclusions: Though outcomes for lead and cycle times varied, implementation of Kaizen principles was found to be an effective method for completing this quality improvement project at a large cochlear implant program overall. Level of Evidence: 3a
Health-related quality of life outcomes following adult cochlear implantation: A prospective cohort study
Sladen, Douglas P. , Peterson, Ann M. , Schmitt, Matt, Olund, Amy P., Teece, Katherine , Dowling, Brittany P., DeJong, Melissa D., Breneman, Alyce, Beatty, Charles W., Carlson, Matthew L. , Neff, Brian A., Hughes-Borst, Becky, Driscoll, Colin L. W., Peterson, Ann, Olund, Amy, Dowling, Brittany , DeJong, Melissa, Driscoll, Colin L., Schmitt, Matthew

Mayo Clinic

Cochlear Implants International | March 31, 2017 | Volume: 18 | Issue: 3 | Pages: 130-135

10.1080/14670100.2017.1293203 | PMID 28248612 Get It

Early outcomes after cochlear implantation for adults and children with unilateral hearing loss
Sladen, Douglas P. , Carlson, Matthew L. , Dowling, Brittany P., Olund, Amy P., Teece, Kathryn, DeJong, Melissa D., Breneman, Alyce, Peterson, Ann M. , Beatty, Charles W., Neff, Brian A., Driscoll, Colin L. W., Teece, Katherine , Peterson, Ann, Driscoll, Colin L.

Mayo Clinic

The Laryngoscope | October 13, 2016 | Volume: 127 | Issue: 7 | Pages: 1683-1688

10.1002/lary.26337 | PMID 27730647 Get It

Objectives/HypothesisThis study was designed to examine speech recognition and self‐perceived health‐related quality of life (HRQoL) received from cochlear implantation among a cohort of adults and children with a short duration of unilateral hearing loss greater than 6 months, but less than 2 years.Study DesignSingle‐subject repeated measures prospective study.MethodsThis study assessed changes in speech recognition and self‐perceived quality of life by prospectively analyzing data at the preoperative evaluation and at the 3‐month and 6‐month postactivation intervals. Measurement tools included Medical Outcomes Study Questionnaire Short Form 36, Nijmegen Cochlear Implant Questionnaire, Speech Spatial and Qualities of Hearing–Comparative, and speech recognition measures in quiet and in noise.ResultsResults indicated significant improvement in speech recognition, both in quiet and noise. Quality‐of‐life measures showed a significant increase in self‐perceived benefit with disease‐specific instruments, but remained constant with a generic HRQoL instrument.ConclusionsCochlear implantation was a successful intervention for improved hearing in quiet and noise, and a self‐perceived benefit for this group of adults and children with a short duration of unilateral hearing loss.Level of Evidence4 Laryngoscope, 127:1683–1688, 2017