Citations

Clear

6 citation(s) found for "Cheema, Kamal Preet P".

Abstract 4366314: Outcomes of patients with Cardiac Sarcoidosis (CS) implanted with an implantable cardiac defibrillator (ICD).
Yusuf, Ali, Cheema, Kamal Preet P, Zhang, Nan , Karikalan, Suganya Arunachalam , Masry, Hicham El

Mayo Clinic

Circulation | November 3, 2025 | Volume: 152 | Issue: Suppl_3 | Pages: No page available

10.1161/circ.152.suppl_3.4366314 Get It

Background: We aimed to evaluate the outcomes of patients with confirmed and possible cardiac sarcoidosis who had an ICD implant and identify predictors of ventricular arrhythmias and mortality in this patient population. Methods: We performed a retrospective study patients with a diagnosis of cardiac sarcoidosis (CS) at Mayo Clinic and had an ICD implanted for primary or secondary prevention indication. Adult patients (≥18 years) with a diagnosis of possible or confirmed (biopsy-proven) CS with an ICD implanted between 1993 and 2022 were included. Primary outcomes included sustained ventricular arrhythmia (VT) resulting in a documented appropriate ICD shock and death from any cause. Secondary outcomes included ICD-related complications. Results: We identified 148 patients, in which 23 patients (15.5%) experienced VT events with a total of 160 treated episodes. 4 patients (2.7%) experienced inappropriate ICD shocks (11 episodes). During a median follow up of 3.1 years, 26 patients deceased, and the overall survival was 98% and 77% at 1 and 5 year. Older age, CAD, CKD, paced rhythm and QRS duration were associated with worse survival (Figure 1 – 4) . Device related complications were rare, except for the higher percentage of CHF in patients with VT after implant, however this was not statistically significant. Patients with ICD therapies were younger (53 vs 58 years, p=0.029), had higher LGE burden (26.9 vs 16.3%, p=0.01), and higher percentage of LV mass (26.9 vs 16.3, p=0.011). Multivariate logistic regression model which showed that patients with biopsy proven sarcoidosis had significantly higher odds of VT events (OR: 3.04, 95% CI: 1.02 to 9.08, p = 0.046). In patients with increased LV mass (every 10 g increase), the odds of developing VT increased by 1.49 (95% CI: 1.02 to 2.19, p = 0.041). LV mass and LGE percentage showed fair ability of predicting the outcome by ROC analysis. Youden’s index showed 26 for LV mass and 16% for LGE percent as the optimal cut-off points for predicting VT outcomes (Figure 5) . The sensitivity, specificity, positive predictive value, negative predictive value were 81.8%, 74.1%, 37.5%, 95.6% and 75.4% respectively for an LV mass of 26 grams and 81.8%, 63.8%, 30.0%, 94.9% and 66.7% respectively for an LGE percentage of 16%. Conclusion: LGE burden continues to be a major predictor for VT events in patients with CS. Myocardial tissue burden and electrical abnormalities from CS predict mortality than myocardial function loss.
Interaction of positive airway pressure mask magnets with cardiac implantable electronic devices
Ruoff, Chad M., Tashman, Yasemin S., Cheema, Kamal Preet K., Miller, Bernie W., Houser, Ryan F., Lizak, Matthew, Haley, Caitlin C., Petersen, Ann M. , Goswami, Umesh , Lyng, Philip J., Krahn, Lois E., Ruoff, Chad , Lizak, Matthew J, Ruoff, Chad M , Tashman, Yasemin, Petersen, Ann M., Goswami, Umesh, Srivathsan, Komandoor

Mayo Clinic

Journal of Clinical Sleep Medicine | February 1, 2023 | Volume: 19 | Issue: 5 | Pages: 941-946

10.5664/jcsm.10478 | PMID 36722607 Get It

Atrial Arrhythmia Ablation in Patients With D-Transposition of the Great Arteries and Atrial Switch
Chiriac, Anca , Cheema, Kamal Preet, Giardi, Davide , Espinosa, Samantha , Fitzgerald, Patrick , Perez-Downes, Julio , Umadat, Goyal , Hodge, David O. , Phillips, Sabrina D. , Madhavan, Malini , Asirvatham, Samuel J. , Cheema, Kamal P, Espinosa, Samantha M, Perez-Downes, Julio C , McLeod, Christopher J , Asirvatham, Samuel J , Giardi, Davide , McLeod, Christopher J. , Chiriac, Anca

Mayo Clinic

Circulation: Arrhythmia and Electrophysiology | June 28, 2022 | Volume: 15 | Issue: 7 | Pages: No page available

10.1161/circep.121.010546 | PMID 35763440 Get It

Background: Patients with D-transposition of the great arteries and atrial switch have a high incidence of atrial arrhythmias. We sought to analyze the arrhythmia substrate, ablation strategies, and outcomes for catheter ablation in this population. Methods: An in-depth analysis of all clinical and procedural data in patients with D-transposition of the great arteries, atrial baffles, and atrial arrhythmia ablation was performed. Results: A cohort of 32 patients (72% male, mean age 38±7 years) underwent ablation for non-AV nodal reentrant tachycardia atrial arrhythmias, and 4 patients underwent AV nodal reentrant tachycardia ablation. Cavotricuspid isthmus flutter (CTI-flutter) was the most common arrhythmia, encountered in 75% of patients, followed by scar-related intraatrial reentrant tachycardia (non-CTI intraatrial reentrant tachycardia, 53%) and focal atrial tachycardia (focal atrial tachycardia, 6%). Among the 32 patients, 26 underwent 31 procedures at our institution. For patients with prior outside intervention, the index ablation at our institution revealed CTI-dependent flutter in 3/5 cases. However, redo ablation after an index ablation with demonstrated bidirectional CTI block revealed different/new arrhythmia substrates (80% non-CTI intraatrial reentrant tachycardia, 40% focal atrial tachycardia). Achieving bidirectional block across the CTI often required ablating on both sides of the baffle (retroaortic access, 81%; using a baffle leak, 11.5%; or transbaffle puncture, 7.7%). Combined approaches were necessary in 19% to reach the critical tissue. Acute procedural success was 81%, and recurrence was documented in 58% of patients. Despite recurrence, clinical arrhythmia burden was significantly reduced post-ablation ( P <0.001), with rare episodes, amenable to antiarrhythmic therapy. Redo ablation was required in 5 (19%) patients and uncovered new arrhythmia substrates. AV nodal reentrant tachycardia ablation also required transbaffle approaches in 3/4 patients. Conclusions: CTI-dependent flutter was the most common arrhythmia in patients with Dextro-Transposition of the Great Arteries and atrial switch. Transbaffle approaches were often necessary, and, provided that bidirectional CTI block was achieved at the index ablation, late recurrence was due to different arrhythmia mechanisms. Despite recurrence, ablation was associated with significant clinical improvement.
0789 Mask Magnets May Interact with Pacemakers and Implantable Cardioverter-Defibrillators
Ruoff, Chad , Tashman, Yasemin, Miller, Bernie, Cheema, Kamal, Haley, Caitlin, Petersen, Ann, Lizak, Matthew, Goswami, Umesh , Lizak, Trevor, Krahn, Lois E., Ruoff, Chad M , Miller, Bernie, Houser, Ryan Scott , Cheema, Kamal Preet, Haley, Caitlin C., Petersen, Ann, Goswami, Umesh, Srivathsan, Komandoor

Mayo Clinic

Sleep | May 31, 2022 | Volume: 45 | Issue: Supplement_1 | Pages: A342-A343

10.1093/sleep/zsac079.785 Get It

Abstract Introduction Placing a magnet over a Permanent Pacemaker (PPM) or Implanted Cardioverter-Defibrillator (ICD) may cause the device to pace asynchronously or inhibit tachyarrhythmia detection, respectively, potentially preventing delivery of electrical shocks. Manufacturers for masks used with positive airway pressure devices have started using magnets in place of more traditional headgear clips to connect the headgear to mask. Mask manufactures do not list presence of a PPM/ICD as a contraindication to use of a mask with magnet but do recommend keeping the mask some distance away from PPM/ICD. A published case series describes two patients with magnet response events captured during PPM/ICD interrogation that correlated with nightly use of CPAP. The authors were able to replicate the response by placing the mask with magnet directly over the patient’s pulse generate site. Although we advise all patients with implanted device to avoid use of masks with magnets, select patients refuse to stop using mask with magnets regardless of our policy. We, therefore, started offering these patients referral for PPM/ICD interrogation to evaluate for an interaction between mask with magnet and PPM/ICD as next best alternative. Methods We retrospectively reviewed all patients (n=10) referred for routine PPM/ICD interrogation to test whether the mask with magnet interacted with PPM/ICD when mask on face as during normal use (i.e., simulated normal use) or magnetic area of mask placed directly over the PPM/ICD (i.e., direct contact). Results Although no interaction was detected in any patient (n=10) with simulated normal use (0 %), one interaction was documented with direct contact (10 %). Conclusion Although simulated normal use of masks with magnets did not demonstrate any interactions, it is concerning that one patient (10 % of patients) demonstrated an interaction with direct contact of magnetic area of mask over the PPM/ICD. It is not uncommon for patients to remove a mask during the night while sleeping. This preliminary data along with the published case series calls for further research and increased awareness of this potential interaction for both sleep and cardiac health care providers. Support (If Any) None
Abstract 12187: Arrhythmia Substrate and Approaches for First-Time and Repeat Catheter Ablation in Patients With D-transposition of the Great Arteries and Atrial Baffles
Chiriac, Anca , Cheema, Kamal Preet P, Giardi, Davide , Espinosa, Samantha , Fitzgerald, Patrick , Perez-Downes, Julio , Phillips, Sabrina D. , Madhavan, Malini , Umadat, Goyal , Asirvatham, Samuel J. , McLeod, Christopher J.

Mayo Clinic

Circulation | April 28, 2022 | Volume: 144 | Issue: Suppl_1 | Pages: No page available

10.1161/circ.144.suppl_1.12187 Get It

Introduction: Atrial arrhythmias are common in patients with D-TGA and atrial switch. We sought to analyze the arrhythmia substrate and catheter ablation approaches and outcomes. Methods: We performed a retrospective review of all clinical and procedural data in patients with D-TGA followed at a large tertiary care center. Results: In a cohort of 152 patients (mean age 30±11 years), atrial tachycardia was present in 69(45%) patients. Ablations were performed in 39(26%) patients: macro-reentrant atrial flutter (N=37), atrial fibrillation (N=4), and focal automatic atrial tachycardia (N=3). Detailed electrophysiology study data was available for 34 patients. At first ablation (N=28), cavo-tricuspid isthmus dependent flutter (CTI, 23(82%)) was most common, followed by right atriotomy-related flutter (IART, 16(57%)) and focal atrial tachycardia (FAT, 1(3.5%)). Bidirectional CTI block often required ablation on both sides of the baffle to complete the isthmus line. Access to the pulmonary venous atrium was obtained in 82% of first-time ablations (via retrograde aortic access, 74%, baffle puncture, 6%, or baffle fenestration, 12%) and in 100% of redo procedures. The first ablation was acutely successful in 25 (89%) patients; the other 3 patients had either partial procedural success (1), failed ablation (1), or underwent an empirical ablation (1). Long-term arrhythmia recurrence occurred in 13(46%) after the first ablation and class III antiarrhythmic medications were utilized in 12 patients. At least one long-term recurrence occurred in 11(44%) patients. Importantly, clinical arrhythmia burden was significantly reduced post-ablation, with rare and short-limited episodes amenable to antiarrhythmic drugs or cardioversion. Repeat ablation was required in 3 cases. Long-term arrhythmia recurrence after a previously completed CTI line involved different arrhythmia mechanisms: scar-related reentry (80%) and automatic atrial tachycardia (40%). Conclusions: Atrial arrhythmia in patients with D-TGA often involves the CTI and atriotomy scars. Ablation of the CTI typically requires access to the pulmonary venous atrium to achieve bidirectional block. Despite late recurrence, the clinical arrhythmic burden is substantially improved.
Abstract 16391: Systemic Ventricular Dysfunction and Long Term Outcomes in Patients With D-transposition of the Great Arteries (D-TGA), Atrial Switch, and Systemic Right Ventricle Physiology
Chiriac, Anca , Giardi, Davide , Espinosa, Samantha , Fitzgerald, Patrick , Cheema, Kamal Preet P, Perez-Downes, Julio , Hodge, David O. , Phillips, Sabrina D. , Umadat, Goyal , McLeod, Christopher J.

Mayo Clinic

Circulation | November 12, 2020 | Volume: 142 | Issue: Suppl_3 | Pages: No page available

10.1161/circ.142.suppl_3.16391 Get It

Introduction: Patients with D-TGA palliated with atrial switch operations have the morphologic right ventricle in the systemic position. There is increased risk of atrial arrhythmias and systemic right ventricle (SRV) failure. We sought to analyze the long term outcomes of these patients. Methods: All patients with D-TGA and SRV followed in the Adult Congenital Heart Disease Clinic of a large tertiary care institution were reviewed. A comprehensive retrospective analysis of the medical record was performed, including consult notes, ECGs, echocardiograms and electrophysiology reports. Results: A total of 154 patients (63% male) aged 29±11 years were followed for a mean of 10±9 years (range 0-51). During follow-up, 3 patients underwent cardiac transplantation and 15 died; 5 had sudden death, 2 had cardiogenic shock, 5 had non-cardiac death (i.e., infective endocarditis, sepsis) and 3 had unknown causes of death. Heart failure symptoms were present in 53(34%) patients. Severe SRV systolic dysfunction occurred in 37(24%) patients, with a mean EF of 23±5.5%; moderate SRV dysfunction occurred in 67(44%) patients, mean EF 35±4%. Sinus node dysfunction was present in 75(49%) patients, complete AV block in 9(5%) patients, and a pacemaker placed in 60(39%) patients, with cardiac resynchronization therapy in 5. Atrial arrhythmias occurred in 94(61%) patients and ablations were performed in 47(31%) patients. An ICD was implanted in 37 patients; 5 patients had appropriate shocks, but 7 had inappropriate shocks due to atrial arrhythmias. Age (HR 1.07, p=001), heart failure symptoms (HR 4.9, p= 0.007), severe SRV enlargement (HR 3.7, p=0.03), severe systolic dysfunction (HR 5.4, p=0.003), severe systemic AV valve regurgitation (HR 5.2, p=0.002) and a QRS duration> 122ms (HR 3.7, p=0.02) were significant predictors of mortality. The 15 year probability of sudden death was 3.2%(95% CI 0-6.9%). Conclusions: Atrial arrhythmias are common after atrial switch operations secondary to atriotomy scars. Further studies will need to determine whether restoration of sinus rhythm or cardiac synchrony may prevent further deterioration of the systemic right ventricle. Severe SRV dysfunction and prolonged QRS duration >122ms were significantly correlated with mortality.