Citations

Clear

8 citation(s) found for "Acker, Nancy".

Proteomic Biomarkers of Sacubitril/Valsartan Treatment Response in Heart Failure With Preserved Ejection Fraction: Molecular Insights Into Sex Differences
Nguyen, Thanh Thanh L. , Wang, Min , Liu, Duan , Bonilla, Hilda Mariana Gonzalez , Acker, Nancy, Murthy, Vishakantha , Shrivastava, Sanskriti , Desai, Viral , Burnett, John C. , Redfield, Margaret M. , Bailey, Kent R. , Weinshilboum, Richard M. , Pereira, Naveen L. , Iyer, Seethalakshmi , Gonzalez Bonilla, Hilda Mariana, Desai, Viral K , Redfield, Margaret, Pereira, Naveen L , Nguyen, Thanh Thanh L. , Wang, Min , Liu, Duan , Weinshilboum, Richard M.

Mayo Clinic

Circulation: Heart Failure | September 20, 2022 | Volume: 15 | Issue: 9 | Pages: No page available

10.1161/circheartfailure.122.009629 | PMID 35656806 Get It

Effect of Treatment With Sacubitril/Valsartan in Patients With Advanced Heart Failure and Reduced Ejection Fraction
Givertz, Michael M. , Shah, Palak , McNulty, Steven E., Anstrom, Kevin J. , Mahr, Claudius , Gupta, Divya , Redfield, Margaret M. , Lala, Anuradha , Desvigne‐Nickens, Patrice , Braunwald, Eugene, Investigators, LIFE, Mohammed, Selma F. , Birru, Hellina, Aboye, Etsubdink, Lam, Phillip H. , Escobar, Nicole, Fink, Maria Cristina Domingues , Cappola, Thomas P. , Sheaffer, Wendy , Reilly, Bonitta, Ferree, J W, Ciezkowski, Gina, Herrera, Glenda, Mehta, Hirsch, Delucca, Rosemarie, Doddamani, Sanjay , Thomas, B. , Machen, Laurie, Kim, J., Christina, Athas, Lampert, Brent C. , Fontenelle, Cindy, Eiswirth, Clement, Rock, Darlene, Egnaczyk, Gregory F. , Rentas-Sherman, Enya, Barr, Deborah, Damato, Adrianna, Calayo, Christine, Herre, John M. , Carroll, Amanda , Keebler, Mary , Setliff, Bandaa, Gulati, Sanjeev , Winkler, K, Curtin, Laura, Ohmart, Carly, Halvorson, John, Mudd, James O., Camacho, S. Albert , Palardy, Maryse , Shah, Neha, Picardi, Kristina, Krishnamoorthy, Arun, Maximin, Adrienne, Horstmanshof, Douglas , Seiler, Beverly, Xu, Zi J., Mersola, S., Kransdorf, E. , Fonk, T., Oliveira, Guilherme H., Semenec, Terrence, Leo, Peter , Dunlap, Mark E. , Felker, G. Michael , Taylor, Lacey D., Sheehan, Mary, Levine, Sharon, Cocca-Spofford, Diane, Brooks, Liana, Cunningham, Thomas F., Acker, Nancy, Milbrandt, Susan, Gatzke, Janet, Dávila‐Román, Víctor G. , Bult, Karen, Weber, Elizabeth, Lesko, Mary, Mikhalkova, Deana , Fitzgerald, Kathleen, Whellan, David J. , Gutierrez, Jonathan, Goldsborough, Yavette, Caikauskaite, Indre, Skopicki, Hal A. , Huggins, Gordon S. , Yuen, Nathan, Haynes, Abbey, Katie, Carr, Snell, Gail, Smith, Andrew L. , Walker, Brandon S. , JOHNSON, J. Y. M., Henderson, Simmone, Pauwaa, Sunil, Bhat, Geetha , Gagliardi, A.R.T., Mann, Douglas L. , Vader, Justin M. , Starling, Randall C. , Margulies, Kenneth B. , Kiernan, Michael S. , Lewis, Gregory D. , DeVore, Adam D. , Hernandez, Adrian F. , Braunwald, Eugene , Investigators, LIFE, Aboye, Etsubdink A, Fink, Maria, Ferree, Jenny, Ravichandran, Ashwin Kumar , Herrera, Glenda, Kanwar, Manreet , Williams, Julie , Bhimaraj, Arvind , Lindenfeld, JoAnn , Gordon, Mary Ellen , Gulati, Sanjeev K., Winkler, Krystal, Tang, W.H. Wilson , Gorodeski, Eiran Z. , Norton, Nadine , Nichols, Julie, Taylor, Lacey, Cunningham, Thomas, Dirks, Anne, Wever‐Pinzon, Omar , Gilotra, Nisha A , Walker, Brandon, Henderson, Simmone, Gagliardi, Ann, Shah, Palak

Mayo Clinic

JAMA Cardiology | November 3, 2021 | Volume: 7 | Issue: 1 | Pages: 17

10.1001/jamacardio.2021.4567 | PMID 34730769 Get It

Mortality After Magnetic Resonance Imaging of the Brain in Patients With Cardiovascular Implantable Devices
Padmanabhan, Deepak , Jondal, Mary Lou, Hodge, David O. , Mehta, Ramila A. , Acker, Nancy G., Dalzell, Connie, Asirvatham, Samuel J. , Cha, Yong‐Mei , Felmlee, Joel P. , Watson, Robert E. , Friedman, Paul A. , Jondal, Mary L, Dalzell, Connie M, Kapa, Suraj , Asirvatham, Samuel J

Mayo Clinic

Circulation: Arrhythmia and Electrophysiology | January 10, 2018 | Volume: 11 | Issue: 1 | Pages: No page available

10.1161/circep.117.005480 | PMID 29321191 Get It

Background: Use of magnetic resonance imaging (MRI) brain is restricted in patients with cardiovascular implantable electronic devices (CIEDs). We proposed to determine whether mortality difference exists for patients with non–MRI-conditional CIEDs undergoing brain MRI compared with controls. Methods and Results: Retrospective analysis of prospectively collected data was performed to compare all-cause mortality in patients with CIEDs undergoing brain MRI (CIED-MRI) with 3 control groups matched for age, sex, imaging year, and type of CIED: (1) no CIED, brain MRI (no–CIED-MRI); (2) CIED, brain computerized tomography (CT) scan (CIED-CT); and (3) no CIED, brain CT (no–CIED-CT). The primary outcome was a significant difference ( P <0.05) between estimated mortality rates. Secondary outcomes were changes in device function before and after brain MRI. The estimated all-cause mortality at 5 years for the CIED-MRI group [mean age (±SD), 68.2 years (15.3 years); 61.2% men] was not significantly different from patients who underwent CT with or without a device (CIED-CT group: hazard ratio, 0.814; 95% confidence interval, 0.593–1.117; P =0.2; no–CIED-CT group: hazard ratio, 1.149; 95% confidence interval, 0.818–1.613; P =0.4). There was a significant increase in mortality between CIED-MRI and no–CIED-MRI groups (hazard ratio, 1.463; 95% confidence interval, 1.019–2.099; P =0.04). Conclusions: Brain MRI in patients with CIEDs does not carry an increased mortality risk compared with brain CT and can be performed with adherence to appropriate procedural protocols.
Utility of T-wave amplitude as a non-invasive risk marker of sudden cardiac death in hypertrophic cardiomyopathy
Sugrue, Alan , Killu, Ammar M. , Chahal, C. Anwar A. , Vogt, J., Křemen, Václav , Hai, Jo Jo , Hodge, David O. , Acker, Nancy G., Geske, Jeffrey B. , Ackerman, Michael J. , Ommen, Steve R. , Lin, Grace , Brady, Peter A. , Chahal, Anwar A, Vogt, Josh C, Hai, JoJo, DeSimone, Christopher V. , Noseworthy, Peter A. , Chahal, Choudhary Anwar A , Kremen, Vaclav , Geske, Jeffrey B

Mayo Clinic

Open Heart | February 24, 2017 | Volume: 4 | Issue: 1 | Pages: e000561

10.1136/openhrt-2016-000561 | PMID 28409011 Get It

Objective Sudden cardiac arrest (SCA) is the most devastating outcome in hypertrophic cardiomyopathy (HCM). We evaluated repolarisation features on the surface electrocardiogram (ECG) to identify the potential risk factors for SCA. Methods Data was collected from 52 patients with HCM who underwent implantable cardioverter defibrillator (ICD) implantation. Leads V2 and V5 from the ECG closest to the time of ICD implant were utilised for measuring the Tpeak-Tend interval (Tpe), QTc, Tpe/QTc, T-wave duration and T-wave amplitude. The presence of the five traditional SCA-associated risk factors was assessed, as well as the HCM risk-SCD score. Results 16 (30%) patients experienced aborted cardiac arrest over 8.5±4.1 years, with 9 receiving an ICD shock and 7 receiving ATP. On univariate analysis, T-wave amplitude was associated with appropriate ICD therapy (HR per 0.1 mV 0.79, 95% CI 0.56 to 0.96, p=0.02). Aborted SCA was not associated with a greater mean QTc duration, Tpeak-Tend interval, T-wave duration, or Tpe/QT ratio. Multivariate analysis (adjusting for cardinal HCM SCA-risk factors) showed T-wave amplitude in Lead V2 was an independent predictor of risk (adjusted HR per 0.1 mV 0.74, 95% CI 0.57 to 0.97, p=0.03). Addition of T-wave amplitude in Lead V2 to the traditional risk factors resulted in significant improvement in risk stratification (C-statistic from 0.65 to 0.75) but did not improve the performance of the HCM SCD-risk score. Conclusions T-wave amplitude is a novel marker of SCA in this high risk HCM population and may provide incremental predictive value to established risk factors. Further work is needed to define the role of repolarisation abnormalities in predicting SCA in HCM.
Magnetic Resonance Imaging in Nondependent Pacemaker Patients with Pacemakers and Defibrillators with a Nearly Depleted Battery
Okamura, Hideo , Padmanabhan, Deepak , Watson, Robert E. , Dalzell, Connie, Acker, Nancy, Jondal, Mary Lou, ROMME, ABBY L., Cha, Yong‐Mei , Asirvatham, Samuel J. , Felmlee, Joel P. , Friedman, Paul A. , Jondal, Mary, Asirvatham, Samuel J

Mayo Clinic

Pacing and Clinical Electrophysiology | February 7, 2017 | Volume: 40 | Issue: 5 | Pages: 476-481

10.1111/pace.13042 | PMID 28169434 Get It

BackgroundMagnetic resonance imaging (MRI) in patients with non‐MRI‐conditional cardiac implantable electronic devices (CIEDs) has been shown to be safe when performed under closely monitored protocols. However, the safety of MRI in patients with devices with a nearly depleted battery has not been reported.MethodsProspective data were collected between January 2008 and May 2015 in patients with non‐MRI‐conditional CIEDs undergoing clinically indicated MRI under institutional protocol. Patients who were pacemaker dependent were excluded. Patients whose devices were at elective replacement indicator (ERI) at the time of MRI or close to ERI (ERI or replacement for battery depletion within 3 months of scan) were identified through database review and analyzed for clinical events.ResultsMRI scans (n = 569) were performed in 442 patients. Of these, we identified 13 scans performed with a nearly depleted battery in nine patients. All scans with implantable cardioverter defibrillators (ICDs, n = 9) were uneventful. However, two scans with pacemakers close to ERI resulted in a power‐on‐reset (PoR) event. One scan with a pacemaker close to ERI that was programmed to DOO mode reached ERI during MRI and automatically changed to VVI mode. Additionally, one scan with a pacemaker at ERI did not allow programming. All pacemakers with events were implanted before 2005.ConclusionPatients with pacemakers and ICDs with a nearly depleted battery can safely undergo MRI when patients are not pacemaker dependent. Attention should be paid because old devices can result in PoR or ERI during MRI, which may lead to oversensing and inhibition of pacing.
Outcomes and Complications of Lead Removal: Can We Establish a Risk Stratification Schema for a Collaborative and Effective Approach?
Fu, Hai‐Xia , Huang, Xinmiao, Li, Zhong , Osborn, Michael J., Asirvatham, Samuel J. , Espinosa, Raúl E. , Brady, Peter A. , Lee, Hon-Chi , Greason, Kevin L. , Sohail, M. Rizwan , Acker, Nancy G., Hodge, David O. , Friedman, Paul A. , Cha, Yong‐Mei , Sohail, Rizwan M., Baddour, Larry M. , Asirvatham, Samuel J , Sohail, M Rizwan

Mayo Clinic

Pacing and Clinical Electrophysiology | August 21, 2015 | Volume: 38 | Issue: 12 | Pages: 1439-1447

10.1111/pace.12736 | PMID 26293652 Get It

Safety and Outcomes of Magnetic Resonance Imaging in Patients with Abandoned Pacemaker and Defibrillator Leads
Higgins, John V., Gard, Joseph J., Espinosa, Raúl E. , Wood, Christopher P. , Felmlee, Joel P. , Cha, Yong‐Mei , Asirvatham, Samuel J. , Dalzell, Connie, Acker, Nancy, Watson, Robert E. , Friedman, Paul A. , Sheldon, Seth H. , Asirvatham, Samuel J

Mayo Clinic

Pacing and Clinical Electrophysiology | May 9, 2014 | Volume: 37 | Issue: 10 | Pages: 1284-1290

10.1111/pace.12419 | PMID 24809591 Get It

IntroductionAbandoned cardiovascular implantable electronic device (CIED) leads remain a contraindication to magnetic resonance imaging (MRI) studies, largely due to in vitro data showing endocardial heating secondary to the radiofrequency field. We tested the hypothesis that abandoned CIED leads do not pose an increased risk of clinical harm for patients undergoing MRI.MethodsThis single‐center retrospective study examined the outcomes of patients who had device generators removed before MRI, rendering the device leads abandoned. Information was gathered through chart review. Data collected included lead model, pacing threshold before MRI, anatomic region examined, threshold data after generator reimplantation, and clinical patient outcome.ResultsPatients (n = 19, 11 men and eight women) ranged in age from 19 to 85 at the time of MRI. There was a mean of 1.63 abandoned leads at the time of imaging; none of the leads were MRI conditional. Of the three implantable cardioverter defibrillator (ICD) leads, two of three were dual coil. Most (31/35) of the scans performed were of the central nervous system, including head and spinal imaging. There were no adverse events associated with MRI in any of these patients with abandoned leads within 7 days of the scan. No lead malfunctions or clinically significant change in pacing thresholds were noted with generator reimplantation.ConclusionThe use of MRI in patients with abandoned cardiac device leads appears feasible when performed under careful monitoring, with no adverse events, although the experience is small. MRI did not affect the function of leads that were subsequently reconnected to a cardiac device.
Magnetic Resonance Imaging in Patients with Recently Implanted Pacemakers
Friedman, Hannah, Acker, Nancy, Dalzell, Connie, Shen, Win K., Asirvatham, Samuel J. , Cha, Yong‐Mei , Hodge, David O. , Felmlee, Joel P. , Watson, Robert E. , Friedman, Paul A. , Friedman, Hannah L, Asirvatham, Samuel J

Mayo Clinic

Pacing and Clinical Electrophysiology | July 4, 2013 | Volume: 36 | Issue: 9 | Pages: 1090-1095

10.1111/pace.12213 | PMID 23826621 Get It

BackgroundRecent studies have shown that magnetic resonance imaging (MRI) of patients with pacemakers can be safely performed under careful monitoring, but they excluded patients with recently implanted devices. Patients with recent implants may be at a greater risk for complications during MRI imaging due to lack of lead and wound maturity.MethodsWe implemented a clinical protocol for MRI imaging of patients with implanted cardiac devices, and prospectively collected data. For this study, we retrospectively analyzed two groups of patients: those with recently implanted (≤42 days) and nonrecently implanted (>42 days) leads at the time of MRI scanning. All devices were interrogated before and after scanning, and were reprogrammed during the scan as per protocol.ResultsOf the 219 scans (in 171 patients), eight included patients with recently implanted (range: 7–36 days) and 211 with only nonrecently implanted pacemaker leads. During the scan, there were no complications in the early or late group. In one patient imaged 79 days postimplant, frequent premature ventricular complexes were noted during the scan, requiring no action. No patient reported pain during or immediately after the procedure. No clinically significant changes in function were seen at subsequent follow up (average 104 days post‐MRI). Compared to patients with nonrecently implanted leads, there was no difference in any parameter between the two groups.ConclusionsWith a strong clinical indication and with careful monitoring, MRI imaging is feasible in patients with recently implanted pacemakers, although experience is limited.