Citations

Clear

36 citation(s) found for "Abia‐Trujillo, David".

Comparing Complications Between Shape‐Sensing Robotic‐Assisted Bronchoscopy and Trans‐Thoracic Needle Pulmonary Biopsy Approaches: Insights From a Large Nationally Representative Administrative Database
Abia‐Trujillo, David , Fernandez-Bussy, S, Husta, B C, Milky, Gediwon , Wing, Sam E., Gaertner, Adam, Oh, Scott , Abia-Trujillo, David , Folch, Erik E. , Wing, Sam E.

Mayo Clinic

Thoracic Cancer | July 10, 2026 | Volume: 17 | Issue: 13 | Pages: No page available

10.1111/1759-7714.70324 | PMID 42425909 Get It

ABSTRACT Background Shape‐sensing robotic‐assisted bronchoscopy (ssRAB) is a navigation platform for biopsy of indeterminate pulmonary lesions. Large‐scale, real‐world evidence confirming the safety profile of ssRAB compared to transthoracic needle biopsy (TTNB) is needed. Study Design and Methods A retrospective cohort study was performed using the PINC AI healthcare database among patients who underwent ssRAB or TTNB lung lesion biopsy at participating hospitals between April 2019 and March 2023. Outcomes were rates of pneumothorax and pneumothorax requiring chest‐tube intervention within 3 days, and rates of in‐hospital bleeding or all‐cause death. Quasi‐binomial logistic regression analysis was performed after one‐to‐five propensity score matching (PSM) accounting for patient‐ and hospital‐related characteristics. Results A total of 119 424 patients (5121 ssRAB, 114 303 TTNB) were identified with 4554 ssRAB and 14 319 TTNB patients after PSM. Relative to ssRAB, TTNB had significantly higher risk of pneumothorax (18.4% vs. 2.6%, OR = 7.10, p < 0.001) and pneumothorax requiring chest‐tube (10.8% vs. 1.4%, OR = 7.62, p < 0.001). TTNB was associated with a higher risk for bleeding (1.5% vs. 0.6%, OR = 2.20, p < 0.001) and all‐cause death (0.48% vs. 0.15%, OR = 2.47, p = 0.023); however, rates for both outcomes were relatively low. Interpretation In this large‐scale, real‐world database analysis with diverse patient populations, physician experience, and health care settings, ssRAB demonstrated a better safety profile compared to TTNB. Superior safety combined with a potentially comparable performance profile and known advantages of bronchoscopy, including concurrent staging, support ssRAB as an optimal choice for non‐surgical biopsies for suspicious pulmonary lesions.
Multidisciplinary Management of Tracheal Perforation: A Case of Successful Reconstruction and Stenting
Valdes‐Camacho, Sofia , Murillo‐Torres, Regina M. , Rojas-Zapata, Tatiana A. , Lee‐Mateus, Alejandra Yu , Gutierrez‐Gallegos, Paola , Valencia, Bastien A. , Anderson, Elise, Robertson, Kelly S , Fernández-Bussy, Sebastián , Janus, Jeffrey R. , Yu Lee-Mateus, Alejandra , Valencia‐Sanchez, Bastien A. , Abia-Trujillo, David , Abia‐Trujillo, David

Mayo Clinic

Respirology Case Reports | July 8, 2026 | Volume: 14 | Issue: 7 | Pages: No page available

10.1002/rcr2.70661 | PMID 42416892 Get It

ABSTRACT Airway perforation is a potentially lethal complication from tracheal or mediastinal malignancies that require complex management. Advanced thyroid cancer is known to have high morbidity, and patients with tracheal metastatic lesions are vulnerable to injury. Therapeutic management typically comprises a combination of surgical and nonoperative treatment modalities, whose adverse effects can lead to significant airway injury. We present the case of a 67‐year‐old man with papillary thyroid carcinoma who developed a tracheocutaneous fistula following proton beam therapy and chemotherapy for metastatic disease. Airway repair and recanalization were successfully achieved through a combined surgical and bronchoscopic approach.
Robotic Assisted Bronchoscopy with Endobronchial Ultrasound for the Evaluation of Multiple Pulmonary Nodules: A Multi-Center Registry
Kapp, Christopher M. , Wahidi, Momen M, Rowell, J. M., Yong, Sylvia S, Seides, Benjamin, Smith, Sean B. , Balan, Bharat, DiBardino, David, Haas, K, White, Brian, Kim, Jeremy , Guiance, Irene Riestra , Bhargava, Rohan , Diaz, Natalia H, Trujillo, D. Abia, Silvestri, G, Liu, Yupeng, Pfister, Courtney, Thiboutot, Jeffrey, Lee-Mateus, Alejandra Y, Abia Trujillo, David, Wahidi, Momen M. , Rowell, Jamie H, YONG, SYLVIA S, DiBardino, David M. , Haas, Kevin P. , Diaz, Natalia, Lee‐Mateus, Alejandra Yu , Thiboutot, Jeffrey P.

Mayo Clinic

Annals of the American Thoracic Society | June 29, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1093/annalsats/aaoag142 | PMID 42366642 Get It

Abstract Introduction Multiple pulmonary nodules (MPNs) are commonly encountered in patients at elevated risk for thoracic malignancy and represent a spectrum of disease states and stages. We evaluated the safety, and procedural outcomes of a combined robotic assisted bronchoscopy (RaB) and linear endobronchial ultrasound (EBUS) approach to patients with MPNs during a single bronchoscopic procedure. Methods This multicenter observational registry included patients who underwent RaB for evaluation of MPNs. Data were prospectively collected from six centers between 2019 and 2025. Demographics, imaging characteristics, safety events, and procedural outcomes were analyzed and associated with final diagnosis. Results A total of 191 patients underwent RaB with biopsy of MPN during a single procedure; 167 patients also underwent linear EBUS lymph node sampling. The strict per nodule diagnostic yield was 71.5% overall (first nodule 70.7%, second 74.3%, third 71.4%). At least one malignant nodule was identified in 127 patients (66.8%), and 85 patients (44.5%) had two or more malignant nodules; 15 patients (17.6%) demonstrated heterogeneous histopathology between malignant nodules. Among patients with non–small cell lung cancer, adequate cellularity for next generation sequencing was achieved in 82.6% of nodules. Malignant lymph nodes were identified in 10.8% (18/167). No patients with two pure ground glass nodules (0/8) had malignant nodal involvement. Pneumothorax occurred in 7.3% of cases, with 2.1% requiring chest tube placement; unplanned admissions occurred in 3.7%. Conclusion This study provides a large multisite registry evaluation of performance of simultaneous bronchoscopic sampling of multiple pulmonary nodules with EBUS staging during a single anesthesia event demonstrating an acceptable safety profile and adequacy for molecular profiling.
EBUS ‐Guided Incidental Finding of Pulmonary Vein Thrombosis: A Case Report and Literature Review
Alqawasma, M, Yesilkaya, Y E, Rojas-Zapata, Tatiana A. , Murillo‐Torres, Regina, Lee-Mateus, A Yu, Vu, L, Fleissner, Zachary J., Husta, B C, Abia‐Trujillo, David , Fernandez-Bussy, S, Lee‐Mateus, Alejandra Yu , Vu, Linh H. , Alqawasma, Mohammed A., Yesilkaya, Yunus E, Yu Lee-Mateus, Alejandra , Vu, Linh H , Abia-Trujillo, David , Murillo‐Torres, Regina M.

Mayo Clinic

Respirology Case Reports | June 4, 2026 | Volume: 14 | Issue: 6 | Pages: No page available

10.1002/rcr2.70612 | PMID 42369328 Get It

ABSTRACT Pulmonary vein thrombosis (PVT) is an uncommon but potentially fatal condition that is often underdiagnosed due to nonspecific clinical presentation. We report a case of a 47‐year‐old woman with a thrombus in the right inferior pulmonary vein incidentally found during a robotic‐assisted bronchoscopy biopsy (RAB) and endobronchial ultrasound (EBUS) performed for mediastinal evaluation and lymph node sampling. PVT was confirmed with computed tomography pulmonary angiography, and the patient was successfully treated with anticoagulation therapy. A review of the literature revealed that reports of PVT detected via EBUS are exceedingly rare and usually malignant in nature. To our knowledge, this is the first peer‐reviewed case report describing PVT identified incidentally during EBUS, underscoring the potential of this technique to reveal clinically significant vascular abnormalities.
C44-26 Robotic-assisted Bronchoscopy for Fungal Lung Infections: Overcoming the Diagnostic Limitations of Bronchoalveolar Lavage (BAL) Antigen Testing
Yesilkaya, Y E, Alqawasma, M, Abia-Trujillo, D, Lee-Mateus, A Yu, Husta, B, Vu, L, Rojas-Zapata, T, Gutierrez-Gallegos, P, Karki, D, Murillo-Torres, R, Robertson, K, Hazelett, B, Fernandez-Bussy, S, Yesilkaya, Y E, Alqawasma, Mohammed A., Abia‐Trujillo, David , Lee‐Mateus, Alejandra Yu , Husta, Bryan , Rojas-Zapata, Tatiana A. , Gutierrez‐Gallegos, Paola , Karki, D, Murillo‐Torres, Regina M. , Robertson, Kelly S , Hazelett, Britney N. , Fernandez-Bussy, S

Mayo Clinic

American Journal of Respiratory and Critical Care Medicine | May 18, 2026 | Volume: 212 | Issue: Supplement_1 | Pages: No page available

10.1093/ajrccm/aamag162.3516 Get It

Abstract Introduction The diagnosis of fungal lung infections remains challenging as standard tests, such as bronchoalveolar lavage (BAL) antigen testing, often yield variable or inconclusive results. These limitations can delay appropriate therapy and may require additional tissue sampling for definitive diagnosis. Robotic-assisted bronchoscopy (RAB) biopsy has been primarily used as a minimally invasive technique for assessing suspicious peripheral pulmonary lesions (PPL). This case series highlights the diagnostic utility of RAB for identifying fungal infections within PPL when conventional BAL antigen analysis is non-diagnostic. Case Description Four patients with suspected infectious or malignant PPL underwent RAB-guided biopsy for diagnostic clarification, all yielding histopathologic confirmation of fungal disease. The first, a 73-year-old bilateral lung-transplant recipient with hemoptysis, had a negative BAL Aspergillus antigen despite RAB biopsy confirming Aspergillus infection. Similarly, a second 73-year-old man with chronic obstructive pulmonary disease (COPD) and esophageal adenocarcinoma had a negative BAL antigen, while RAB biopsy of bilateral cavitary lesions confirmed Aspergillus. Additionally, a 39-year-old woman with a nodule being evaluated for malignancy, had negative BAL Histoplasma antigen and PCR, whereas RAB biopsy confirmed Histoplasma capsulatum. In contrast, a 56-year-old woman with a right-lower-lobe nodule had a positive BAL Aspergillus antigen that aligned with the histopathologic biopsy findings. Discussion BAL-based antigen testing demonstrates variable diagnostic accuracy in fungal lung disease. Reported sensitivities for Aspergillus detection are typically high in meta-analysis, approximately 80%-90%, but clinical performance in the immunocompromised or high-risk patients is often substantially lower. Similarly, while BAL antigen testing for Histoplasma performs well in disseminated infections, it often fails to detect localized pulmonary disease. In this series, three out of four patients had negative BAL results in the presence of histopathologic confirmation of fungal infection. While current guidelines consider BAL positivity supportive of a “probable” diagnosis, tissue histopathology remains the gold standard for a “proven” infection. These findings emphasize the value and capability of RAB in obtaining direct tissue confirmation when conventional testing, such as BAL antigen analysis, is non-diagnostic. Conclusion RAB-guided biopsy of PPLs offers the opportunity for histopathologic confirmation of fungal infection when BAL testing is non-diagnostic. This approach can enhance upfront diagnostic yield in patients with suspected fungal pulmonary infections, avoiding delays in diagnosis and treatment initiation. This abstract is funded by: None
Organizing Pleuritis Presenting as Recurrent Lymphocyte Predominant, Exudative Effusion
Alaws, Hossny, Sujanyal, Saurabh Ashok , Talwar, Bhavya, Saunders, Hollie , Abia-Trujillo, David, HELGESON, SCOTT, Balavenkataraman, Arvind , Sujanyal, Saurabh , Alaws, Hossny, Talwar, Bhavya, Saunders, Hollie, Balavenkataraman, Arvind, Abia-Trujillo, David

Mayo Clinic

The Permanente Journal | May 14, 2026 | Volume: 30 | Issue: 3 | Pages: 195-199

10.7812/tpp/26.018 | PMID 42130253 Get It

Regulatory T-cell Sensing of Extracellular ATP via P2RX7 Promotes Their Accumulation and Suppression and Drives Lung Tumor Growth
Santiago-Carvalho, Igor , Francisco, Ronaldo da Silva , Macedo, Bruna de Gois , Salgado, Caio Loureiro , Stoll, Carly R. , Shao, Samantha C. , Beniwal, Angad , Kwok, Tina , Banuelos, Alma , Cione, Marcos Pinheiro , White, Emily , Johnston, Tyler, Leff, Chloe , Silva-Junior, Ildefonso , Souza, Fabio Carvalho de, Thant, Win , Fernandez-Bussy, Sebastian, Abia-Trujillo, David, Vu, Linh H, Husta, Bryan C, Copland, John A. , Gounari, Fotini , Justilien, Verline , Cione, Marcos Vinícios Pinheiro , Francisco, Ronaldo , Macedo, Bruna Gois , Johnston, Tyler M , Leff, Chloe Liliana , Carvalho de Souza, Fabio , Pandya, Prita , D'Império Lima, Maria Regina , Fernandez-Bussy, Sebastian , Abia-Trujillo, David , Vu, Linh H , Tran, Nhan L , Husta, Bryan C , Copland, John A , Gounari, Fotini , Justilien, Verline , Lancaster, Jessica N , Borges da Silva, Henrique , Silva, Ildefonso , Pandya, Prita , Lima, Maria Regina D’Império , Tran, Nhan L. , Lancaster, Jessica N. , Silva, Henrique Borges da

Mayo Clinic

Cancer Immunology Research | January 21, 2026 | Volume: 14 | Issue: 4 | Pages: 658-675

10.1158/2326-6066.cir-25-0567 | PMID 41564348 Get It

Abstract Lung cancer is the leading cause of cancer-related deaths worldwide, and despite advances in treatment, immune suppression remains an obstacle to effective therapy. Effector CD4+ T cells (CD4+ Teff) are critical for antitumor immunity, but their function is often inhibited by regulatory T cells (Treg), which accumulate in lung tumors and mediate suppressive functions through multiple mechanisms. This suppression leads to tumor progression and poor patient outcomes. However, the mechanisms underlying Treg-mediated suppression are not fully understood. Herein, we identify the extracellular adenosine 5-triphosphate receptor P2RX7 as a key regulator of Treg function in lung tumors. In a murine lung cancer model induced by Lewis lung carcinoma cells, we found that P2RX7 enhanced the suppressive capacity of tumor-infiltrating Tregs, promoting tumor growth. In T cell–specific P2RX7-knockout (P2RX7-KO) mice, reduced Treg infiltration was accompanied by increased CD4+ Teff accumulation and improved tumor control. Treg-specific P2RX7-KO mice exhibited reduced tumor growth, confirming a Treg-intrinsic role of P2RX7. Suppression assays revealed that tumor-infiltrating wild-type Tregs had greater suppressive activity compared with P2RX7-KO Tregs, which failed to inhibit type 1 and follicular helper T–like responses. This was associated with increased tumor-specific IgG production by lung B cells in P2RX7-KO mice. We also observed that wild-type Tregs expressed higher levels of the immunosuppressive molecule CTLA-4 when compared with P2RX7-KO Tregs. Thus, we conclude that P2RX7 expression on Tregs is essential for their suppressive function in lung cancer and targeting P2RX7 may constitute a strategy to improve lung cancer treatment by alleviating Treg-mediated immune suppression.
AIM (Anticipate/Adjust, Image, Manage) to Prevent Bleeding During Robotically‐Assisted Bronchoscopic Ablation
Fernández-Bussy, Sebastián , Kornafeld, Anna , Husta, Bryan , Vu, Linh H. , Lee‐Mateus, Alejandra Yu , Alqawasma, Mohammed A., Yu Lee-Mateus, Alejandra , Abia‐Trujillo, David

Mayo Clinic

Respirology Case Reports | September 5, 2025 | Volume: 13 | Issue: 9 | Pages: No page available

10.1002/rcr2.70335 | PMID 40917250 Get It

ABSTRACTTherapeutic treatment of lung nodules by ablation is a new field. Even though not considered standard of care, lung nodule ablation can be appropriate for select cases. Even though ablation is a safe and well‐tolerated procedure, bleeding is a potential complication. We introduce our stepwise approach through two cases on how we AIM (Anticipate/Adjust, Image, Manage) to prevent uncontrolled bleeding during Robotically Assisted Bronchoscopic Ablation: 1. Anticipate structures with high risk for bleeding and adjust accordingly, accounting for the needle ablation field; 2. Image: utilise cone beam CT before the first and after each ablation session to screen for bleeding; 3. Manage bleeding by pre‐emptively utilising Fogarty balloon occlusion.
Successful Treatment of Recurrent Airway Stenosis With Paclitaxel‐Coated Balloons: A Case Report
Gutierrez‐Gallegos, Paola , Vu, Linh H. , Lee‐Mateus, Alejandra Yu , Malla, Milan , Valdes‐Camacho, Sofia , Vaca‐Cartagena, Bryan F. , Valencia‐Sanchez, Bastien A., Anderson, Elise , Fernández-Bussy, Sebastián , Yu Lee-Mateus, Alejandra , Barrios-Ruiz, Alanna, Fernandez-Bussy, Sebastian , Barrios‐Ruiz, Alanna , Valencia‐Sanchez, Bastien A., Abia‐Trujillo, David

Mayo Clinic

Respirology Case Reports | June 26, 2025 | Volume: 13 | Issue: 6 | Pages: No page available

10.1002/rcr2.70261 | PMID 40575399 Get It

ABSTRACTAlthough current treatment strategies for nonmalignant airway stenosis may offer short‐term relief, their effectiveness is limited by high recurrence rates, often requiring additional procedures. While paclitaxel‐coated balloons (PCB) have demonstrated effectiveness in treating stenosis across various vascular and nonvascular conditions, their evidence in recurrent airway stenosis remains limited. Here, we present the case of a 35‐year‐old female with bronchial stenosis who underwent multiple bronchoscopic interventions, all of which were complicated by restenosis. Following the addition of a PCB to the therapeutic regimen, the patient achieved sustained airway patency.
Using Endobronchial Valves to Manage Pneumomediastinum
Vaca‐Cartagena, Bryan F. , Mikulic, Sebastian , Valdes‐Camacho, Sofia , Lee‐Mateus, Alejandra Yu , Barrios‐Ruiz, Alanna , Funes‐Ferrada, Rodrigo , Anderson, Elise , Fernández-Bussy, Sebastián , Mays, S., Trenary, Cody A., Mikulic, Sebastian A , Yu Lee-Mateus, Alejandra , Mays, Samuel D, Abia-Trujillo, David , Mays, Samuel D., Abia‐Trujillo, David

Mayo Clinic

Respirology Case Reports | April 3, 2025 | Volume: 13 | Issue: 4 | Pages: No page available

10.1002/rcr2.70167 | PMID 40190398 Get It

ABSTRACTEndobronchial valves have a variety of potential applications, from lung volume reduction in patients with severe emphysema to closing cavities in those with drug‐resistant tuberculosis. This report presents two cases in which endobronchial valves were effectively used to treat pneumomediastinum.