105 | INTERIM RESULTS OF TANDEM CD20‐CD19‐DIRECTED NON‐CRYOPRESERVED CAR‐T CELLS—ZAMTOCABTAGENE AUTOLEUCEL IN RELAPSED/REFRACTORY DIFFUSE LARGE B CELL LYMPHOMA
307 | IMPACT OF CELL OF ORIGIN, GENE REARRANGEMENTS, FRONTLINE TREATMENT ON INCIDENCE OF CENTRAL NERVOUS SYSTEM LYMPHOMA RELAPSE IN NEWLY DIAGNOSED LARGE B‐CELL LYMPHOMA
29 | A COMPARATIVE ANALYSIS OF HISTOLOGIC TRANSFORMATION OF FOLLICULAR LYMPHOMA AT DIAGNOSIS (COMPOSITE LYMPHOMA) AND SEQUENTIALLY TRANSFORMED FOLLICULAR LYMPHOMA
Summary: Epilepsy neuromodulation treatment failure is a significant challenge, with multiple possible causes. The responsive neurostimulation (RNS) system delivers stimulation from a single current source, and the relative flow of the electrical current through each stimulating contact is inversely proportional to the relative impedance of each contact. Current shunting through low-impedance contacts (i.e., intraventricular contacts) can divert therapy away from the intended targets and may be a cause of treatment failure. We present a case of a patient with bitemporal epilepsy and bitemporal encephaloceles, with poor response to bilateral mesial temporal RNS, who completed stereotactic EEG (sEEG) monitoring to investigate the possible causes of treatment failure. The sEEG was safely completed without damaging the RNS device. The sEEG recorded independent bitemporal interictal epileptiform discharges and seizures, which did not arise from sampled encephalocele regions. The sEEG-recorded RNS stimulation artifact was reduced in the left mesial temporal region relative to the right, which suggested potential current shunting through the right-sided contacts. Impedance measurements confirmed several low-impedance contacts from the right lead, with associated intraventricular position on imaging. At last follow up, 161 days after replacement of the right lead, the patient experienced an additional 58% reduction in seizure burden. Effective therapy delivery by single-current-source neurostimulation systems, such as RNS, critically depends on relative electrode impedances. Current shunting through low-impedance contacts is an underappreciated potential cause of treatment failure. Routine impedance assessments and individualized stimulation programs are recommended to avoid unintended current diversion. Concurrent sEEG monitoring and active RNS are feasible and can characterize stimulation effects.
ITOG 2025 Annual Meeting Summary—Catalyzing the Cure of Advanced Thyroid Cancer
Microdosimetry plays a critical role in particle therapy by quantifying energy deposition within microscopic domains to assess biological effects. This study evaluates the influence of different microdosimetric functions (MFs) and domain geometries (DGs) on relative biological effectiveness (RBE) predictions in carbon ion radiotherapy. Specifically, we compare the analytical microdosimetric function (AMF), calculated for spherical domains and implemented in PHITS, with the Kiefer–Chatterjee (KC) track structure model, which is conventionally applied to cylindrical geometries. To enable a direct comparison, we also introduce a novel implementation of the KC model for spherical domains. Using both models, specific energy distributions were calculated across a range of domain sizes and geometries. These distributions were input into the modified microdosimetric kinetic model (mMKM) to calculate RBE for the HSG cell line and compared against published in vitro data. The results show that both microdosimetric function and domain geometry significantly affect microdosimetric spectra and the resulting RBE, with deviations exceeding 10% when fixed mMKM parameters are used. Parameter optimization within the mMKM enables alignment across models. Our findings emphasize that microdosimetric function and domain geometry selection must be explicitly accounted for in microdosimetry-based RBE modeling, and that model parameters must be tuned accordingly to ensure consistent and biologically accurate predictions.