Citations

Clear

1012 citation(s) found for "Zhao, Yu".

Evaluation of frequency characteristics of shear waves produced by unfocused and focused beams
Amador, Carolina , Zhao, Heng , Lee, Mingu, Shim, Hwan , Greenleaf, James F. , Urban, Matthew W. , Chen, Shigao

Mayo Clinic

The Journal of the Acoustical Society of America | November 1, 2013 | Volume: 134 | Issue: 5_Supplement | Pages: 4011-4011

10.1121/1.4830631 Get It

Measurements of viscoelasticity with shear wave velocity dispersion requires measurements over a large bandwidth. In this study, we explored the parameters that modulate the frequency characteristics of shear waves induced using radiation force push beams. We used a Verasonics ultrasound scanner equipped with a linear array transducer. We performed measurements of shear wave motion induced using both focused and unfocused ultrasound beams. Measurements were made in elastic phantoms with shear moduli of 1, 4, and 16 kPa. The number of elements used for the unfocused beams were varied from 8 to 24, and for the focused beams from 16 to 128. The shear wave motion was tracked using plane wave imaging, and a one-dimensional autocorrelation algorithm applied to the acquired in-phase/quadrature data. At each pixel we calculated the fast Fourier transform of the data and found the center frequency, center-of-gravity, and −3 dB bandwidth. We compared the frequency characteristics from the different push beams. The frequency characteristics were found to be spatially variant and dependent on the number of elements used as well as the shear modulus of the medium. The center frequency, center-of-gravity, and the bandwidth were found to be correlated to one another, and strongly associated with the stiffness of the medium.
Robust shear wave motion tracking using ultrasound harmonic imaging
Zhao, Heng , Manduca, Armando, Kinnick, Randall R., Greenleaf, James F. , Song, Pengfei , Urban, Matthew W. , Pislaru, Sorin V. , Chen, Shigao

Mayo Clinic

The Journal of the Acoustical Society of America | November 1, 2013 | Volume: 134 | Issue: 5_Supplement | Pages: 4010-4010

10.1121/1.4830628 Get It

Robust shear-wave motion detection is essential for producing reliable shear elasticity measurements for ultrasound shear-wave elastography (SWE). However, because shear-wave motion is extracted from radiofrequency signals which can be heavily contaminated by noise, shear-wave motion detection can be very challenging, especially for in vivo applications. This study investigated the implementation of harmonic imaging (HI) to facilitate more robust shear-wave tracking based on HI’s effectiveness in suppressing imaging noise associated with ultrasound reverberation, phase aberration, and clutter noise. A HI shear-wave tracking sequence was developed combining the pulse-inversion HI method with the plane wave imaging technique to transmit phase-inverted pulses at a high frame rate of several kilohertz. The backscattered ultrasound signals from phase-inverted pulses were added to suppress the fundamental and enhance the second harmonic component, from which the shear-wave motion was extracted. A pork belly phantom experiment showed that HI could significantly improve shear-wave motion detection by producing almost three-fold less underestimation of shear-wave motion and over ten-fold more precision for shear-wave speed measurements than fundamental imaging. An in vivo transthoracic case study of a human heart showed that HI substantially improved the success rate of shear-wave motion detection and could provide consistent estimates of the left ventricle myocardium stiffness.
The symptom burden of cancer: Evidence for a core set of cancer‐related and treatment‐related symptoms from the Eastern Cooperative Oncology Group Symptom Outcomes and Practice Patterns study
Cleeland, Charles S. , Chang, Victor T. , Sloan, Jeff A. , O’Mara, Ann M., Weiss, Matthias , Mendoza, Tito R. , Lee, Ju‐Whei, Zhao, Fengmin , Gilman, Paul , Lee, Ju‐Whei , Fisch, Michael , Mendoza, Tito , Chang, Victor T-S

Mayo Clinic

Cancer | October 11, 2013 | Volume: 119 | Issue: 24 | Pages: 4333-4340

10.1002/cncr.28376 | PMID 24114037 Get It

BACKGROUND A set of common cancer‐related and treatment‐related symptoms has been proposed for quality of care assessment and clinical research. Using data from a large, multicenter, prospective study, the authors assessed the effects of disease site and stage on the percentages of patients rating these proposed symptoms as moderate to severe. METHODS The severity of 13 symptoms proposed to represent “core” oncology symptoms was rated by 3106 ambulatory patients with cancer of the breast, prostate, colon/rectum, or lung, regardless of disease stage or phase of care; 2801 patients (90%) repeated the assessment 4 to 5 weeks later. RESULTS At the time of the initial assessment, approximately 33% of the patients reported ≥ 3 symptoms in the moderate‐to‐severe range; 11 of the 13 symptoms were rated as moderate to severe by at least 10% of all patients and 6 were rated as moderate to severe by at least 20% of those receiving active treatment. Fatigue/tiredness was the most severe symptom, followed by disturbed sleep, pain, dry mouth, and numbness/tingling. More patients with lung cancer and patients receiving active treatment reported moderate to severe symptoms. Percentages of symptomatic patients increased by disease stage, less adequate response to therapy, and declining Eastern Cooperative Oncology Group performance status. The percentages of patients reporting moderate to severe symptoms were stable across both assessments. CONCLUSIONS The results of the current study support a core set of moderate to severe symptoms that are common across outpatients with solid tumors, that can guide consideration of progression‐free survival as a trial outcome, and that should be considered in clinical care and in assessments of quality of care and treatment benefit. Cancer 2013;119:4333–4340 . © 2013 American Cancer Society .
The effect of low‐ and high‐velocity tendon excursion on the mechanical properties of human cadaver subsynovial connective tissue
Filius, Anika , Thoreson, Andrew R. , Yang, Tai‐Hua , Vanhees, Matthias , An, Kai‐Nan, Zhao, Chunfeng , Amadio, Peter C. , An, Kai‐Nan

Mayo Clinic

Journal of Orthopaedic Research | September 13, 2013 | Volume: 32 | Issue: 1 | Pages: 123-128

10.1002/jor.22489 | PMID 24038298 Get It

SUMMARYFibrosis of the subsynovial connective tissue (SSCT) in the carpal tunnel is the most common histological finding in carpal tunnel syndrome (CTS). Fibrosis may result from damaged SSCT. Previous studies found that with low‐velocity (2 mm/s), tendon excursions can irreversibly damage the SSCT. We investigated the effect of tendon excursion velocity in the generation of SSCT damage. Nine human cadaver wrists were used. Three repeated cycles of ramp‐stretch testing were performed simulating 40%, 60%, 90%, and 120% of the middle finger flexor tendon superficialis physiological excursion with an excursion velocity of 60 mm/s. Energy and force were calculated and normalized by values obtained in the first cycle for each excursion level. Data were compared with low‐velocity excursion data. For high‐velocity excursions, a significant drop in the excursion energy ratio was first observed at an excursion level of 60% physiological excursion (p < 0.024) and that for low‐velocity excursions was first observed at 90% physiological excursion (p < 0.038). Furthermore, the energy ratio was lower at 60% for high velocities (p ≤ 0.039). Increasing velocity lowers the SSCT damage threshold. This finding may be relevant for understanding the pathogenesis of SSCT fibrosis, such as that accompanying CTS, and a relationship with occupational factors. © 2013 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 32:123–128, 2014.
Transforming growth factor‐β (TGF‐β) expression is increased in the subsynovial connective tissues of patients with idiopathic carpal tunnel syndrome
Chikenji, Takako , Gingery, Anne , Zhao, Chunfeng , Passe, Sandra, Ozasa, Yasuhiro , An, Kai‐Nan, Amadio, Peter C. , Larson, Dirk R. , An, Kai‐Nan , Gingery, Anne

Mayo Clinic

Journal of Orthopaedic Research | September 9, 2013 | Volume: 32 | Issue: 1 | Pages: 116-122

10.1002/jor.22485 | PMID 24014274 Get It

ABSTRACTNon‐inflammatory fibrosis of the subsynovial connective tissue (SSCT) is a hallmark of carpal tunnel syndrome (CTS). The etiology of this finding and its relationship to the development of CTS remain poorly understood. Recent studies have found that transforming growth factor‐β (TGF‐β) plays a central role in fibrosis. The purpose of this study was to investigate the expression of TGF‐β and connective tissue growth factor (CTGF), a downstream mediator of TGF‐β, in the pathogenesis of CTS. We compared SSCT specimens from 26 idiopathic CTS patients with specimens from 10 human cadaver controls with no previous diagnosis of CTS. Immunohistochemistry was performed to determine levels TGF‐β1, CTGF, collagen 1(Col1) and collagen 3 (Col3) expression. TGF‐β1 (p < 0.01), CTGF (p < 0.01), and Col3 (p < 0.01) were increased in SSCT of CTS patients compared with control tissue. In addition, a strong positive correlation was found between TGF‐β1 and CTGF, (R2 = 0.80, p < 0.01) and a moderate positive correlation between Col3 and TGF‐β1 (R2 = 0.49, p < 0.01). These finding suggest that there is an increased expression of TGF‐β and CTGF, a TGF‐β regulated protein, and that this TGF‐β activation may be responsible for SSCT fibrosis in CTS patients. © 2013 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 32:116–122, 2014.
MDM2 phenotypic and genotypic profiling, respective to TP53 genetic status, in diffuse large B-cell lymphoma patients treated with rituximab-CHOP immunochemotherapy: a report from the International DLBCL Rituximab-CHOP Consortium Program
Xu‐Monette, Zijun Y. , Møller, Michael , Tzankov, Alexandar , Montes‐Moreno, Santiago , Hu, Wenwei , Manyam, Ganiraju C. , Kristensen, Louise , Fan, Lei , Visco, Carlo , Dybkær, Karen , Chiu, April , Tam, Wayne , Zu, Youli , Richards, Kristy L. , Choi, William W.L., Krieken, J. Han van , Huang, Qin , Huh, Jooryung , Ferreri, Andrés J.M. , Zhao, Xiaoying , Bueso‐Ramos, Carlos E. , Wang, Sa A. , Winter, Jane N. , Piris, Miguel Á. , Medeiros, L. Jeffrey , Young, Ken H. , Bhagat, Govind , Hsi, Eric D. , Ai, Weiyun Z. , Ponzoni, Maurilio , Wu, Lin , Go, Ronald S. , Li, Yong , Møller, Michael Boe , Winter, Jane N , Tzankov, Alexandar , Dybkaer, Karen , van Krieken, J Han , Young, Ken H , Piris, Miguel , Medeiros, L Jeffrey , Zu, Youli , Montes-Moreno, Santiago , Xu-Monette, Zijun Y

Mayo Clinic

Blood | August 28, 2013 | Volume: 122 | Issue: 15 | Pages: 2630-2640

10.1182/blood-2012-12-473702 | PMID 23982177 Get It

Key PointsPhenotypic and genotypic profiling of MDM2 in DLBCL. MDM2 as a negative regulator of p53 tumor suppressor function.
Research Resource: Global Identification of Estrogen Receptor β Target Genes in Triple Negative Breast Cancer Cells
Shanle, Erin K. , Zhao, Zibo , Hawse, John R. , Wisinski, Kari B. , Keleş, Sündüz , Yuan, Ming , Xu, Wei

Mayo Clinic

Molecular Endocrinology | August 27, 2013 | Volume: 27 | Issue: 10 | Pages: 1762-1775

10.1210/me.2013-1164 | PMID 23979844 Get It

Tendon gradient mineralization for tendon to bone interface integration
Thoreson, Andrew R. , Chen, Qingshan , An, Kai‐Nan, Amadio, Peter C. , Zhao, Chunfeng , Qu, Jin, Qu, Jin , An, Kai‐Nan

Mayo Clinic

Journal of Orthopaedic Research | August 12, 2013 | Volume: 31 | Issue: 11 | Pages: 1713-1719

10.1002/jor.22412 | PMID 23939935 Get It

AbstractTendon‐to‐bone integration is a great challenge for tendon or ligament reconstruction regardless of use of autograft or allograft tendons. We mineralized the tendon, thus transforming the tendon‐to‐bone into a “bone‐to‐bone” interface for healing. Sixty dog flexor digitorum profundus (FDP) tendons were divided randomly into five groups: (1) normal FDP tendon, (2) CaP (non‐extraction and mineralization without fetuin), (3) CaPEXT (Extraction by Na2HPO4 and mineralization without fetuin), (4) CaPFetuin (non‐extraction and mineralization with fetuin), and (5) CaPEXTFetuin (extraction and mineralization with fetuin). The calcium and phosphate content significantly increased in tendons treated with combination of extraction and fetuin compared to the other treatments. Histology also revealed a dense mineral deposition throughout the tendon outer layers and penetrated into the tendon to a depth of 200 µm in a graded manner. Compressive moduli were significantly lower in the four mineralized groups compared with normal control group. No significant differences in maximum failure strength or stiffness were found in the suture pull‐out test among all groups. Mineralization of tendon alters the interface from tendon to bone into mineralized tendon to bone, which may facilitate tendon‐to‐bone junction healing following tendon or ligament reconstruction. © 2013 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 31:1713–1719, 2013
AASLD clinical practice guidelines: A critical review of scientific evidence and evolving recommendations
Koh, Christopher , Zhao, Xiongce, Sakiani, Sasan, Talwalkar, Jayant A., Samala, Niharika , Liang, T. Jake

Mayo Clinic

Hepatology | June 14, 2013 | Volume: 58 | Issue: 6 | Pages: 2142-2152

10.1002/hep.26578 | PMID 23775835 Get It

Distal attachment of flexor tendon allograft: A biomechanical study of different reconstruction techniques in human cadaver hands
Wei, Zhuang, Thoreson, Andrew R. , Amadio, Peter C. , An, Kai‐Nan, Zhao, Chunfeng , Wei, Zhuang, An, Kai‐Nan

Mayo Clinic

Journal of Orthopaedic Research | June 10, 2013 | Volume: 31 | Issue: 11 | Pages: 1720-1724

10.1002/jor.22403 | PMID 23754507 Get It

ABSTRACTWe compared the mechanical force of tendon‐to‐bone repair techniques for flexor tendon reconstruction. Thirty‐six flexor digitorum profundus (FDP) tendons were divided into three groups based upon the repair technique: (1) suture/button repair using FDP tendon (Pullout button group), (2) suture bony anchor using FDP tendon (Suture anchor group), and (3) suture/button repair using FDP tendon with its bony attachment preserved (Bony attachment group). The repair failure force and stiffness were measured. The mean load to failure and stiffness in the bony attachment group were significantly higher than that in the pullout button and suture anchor groups. No significant difference was found in failure force and stiffness between the pullout button and suture anchor groups. An intrasynovial flexor tendon graft with its bony attachment has significantly improved tensile properties at the distal repair site when compared with a typical tendon‐to‐bone attachment with a button or suture anchor. The improvement in the tensile properties at the repair site may facilitate postoperative rehabilitation and reduce the risk of graft rupture. © 2013 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 31:1720–1724, 2013