Citations

Clear

9551 citation(s) found for "James, EM".

Comparative study of vibro-acoustography and B-mode ultrasound in prostate imaging
Mitri, Farid G., Greenleaf, James F., Alizad, Azra , Davis, Brian J. , Fatemi, Mostafa

Mayo Clinic

The Journal of the Acoustical Society of America | May 12, 2008 | Volume: 123 | Issue: 5_Supplement | Pages: 3788-3788

10.1121/1.2935448 Get It

Vibro-acoustography (VA) is an imaging modality that uses the radiation force of ultrasound to vibrate tissue at a low frequency and records the resulting acoustic field to produce an image that is represents object characteristics at both ultrasound as well as low (audio) frequencies. Currently, B-mode ultrasound is used for prostate imaging. This imaging method has some limitations, including the speckle noise, which limit its ability in detection of lesions and calcifications. The purpose of this study is to explore the potentials of VA for prostate imaging. VA, B-mode ultrasound, and radiography were performed on 12 excised human prostate samples and the resulting images were compared. VA system parameters were, center frequency 3 MHz, Δf=50 kHz, image area 5×5 cm, pixel size 0.2×0.2 mm. Images evaluated in terms of visibility of anatomical and pathological structures and contrast. Results showed that prostate anatomical structures, mass lesions, and calcifications were visible in the VA images taken at different depths, and VA image quality was superior to B-mode. VA images exhibited significant contrast between the central and peripheral zones with enhanced borders. It is concluded that, with further development, VA may become suitable modality for in prostate imaging.
Simultaneous Sum-Frequency and Vibro-Acoustography Imaging for Nondestructive Evaluation (NDE) and Testing (NDT) Applications
Mitri, Farid G., Silva, Glauber T. , Greenleaf, James F. , Fatemi, Mostafa

Mayo Clinic

The Journal of the Acoustical Society of America | May 12, 2008 | Volume: 123 | Issue: 5_Supplement | Pages: 3699-3699

10.1121/1.2935101 Get It

High-resolution ultrasound imaging systems for inspection of defects and flaws in materials are of great demand in many industries. Among these systems, Vibro-acoustography (VA) has shown excellent capabilities as a non-contact method for non-destructive high-resolution imaging applications. This method consists of mixing two confocal ultrasound beams, slightly shifted in frequency, to produce an acoustic emission field at the difference frequency of the primary incident ultrasound beams. In addition to the difference frequency signal, there exists another signal at the sum frequency, formed in the intersection region of the two primary beams. The goal of this study is to investigate the formation of high-resolution images using the sum frequency of ultrasound waves in VA while concurrently forming the conventional difference-frequency VA image, thereby increasing the amount of information acquired during a single scan. A theoretical model describing the sum frequency wave propagation, including beam forming and image formation in the confocal configuration is developed and verified experimentally. Moreover, sample experiments are performed on a flawed fiber-reinforced ceramic composite plate. Images at both the difference and sum frequencies are compared and discussed. Results show that the sum frequency image produces a high-resolution C-scan of the plate by which the flaws and structural details of the plate can be detected.
Commentary: CT Screening for Lung Cancer—Caveat Emptor
Jett, James R., Midthun, David E.

Mayo Clinic

The Oncologist | April 30, 2008 | Volume: 13 | Issue: 4 | Pages: 439-444

10.1634/theoncologist.2008-0027 | PMID 18448559 Get It

Abstract There is a great need for a screening test that results in the detection of asymptomatic lung cancer, at a time when there is a substantially better chance for curative treatment. Based on the significant limitations in the results reported to date from nonrandomized, observational screening trials, the authors do not recommend computed tomography screening for lung cancer at this time. Results of two major randomized controlled trials will soon be available.
Long-QT Syndrome After Age 40
Moss, Arthur J. , Polonsky, Slava, Peterson, Derick R. , McNitt, Scott , Zaręba, Wojciech , Andrews, Mark, Ackerman, Michael J. , Benhorin, Jesaia, Kaufman, Elizabeth S. , Locati, Emanuela H. , Napolitano, Carlo , Qi, Ming , Schwartz, Peter J. , Towbin, Jeffrey A. , Vincent, G. Michael, Goldenberg, Ilan , Bradley, James A. , Robinson, Jennifer L. , Priori, Silvia G. , Schwartz, Peter J. , Zhang, Li , Zareba, Wojciech

Mayo Clinic

Circulation | April 21, 2008 | Volume: 117 | Issue: 17 | Pages: 2192-2201

10.1161/circulationaha.107.729368 | PMID 18427134 Get It

Background— Previous studies that assessed the risk of life-threatening cardiac events in patients with congenital long-QT syndrome (LQTS) have focused mainly on the first 4 decades of life, whereas the clinical course of this inherited cardiac disorder in the older population has not been studied. Methods and Results— The risk of aborted cardiac arrest or death from age 41 though 75 years was assessed in 2759 subjects from the International LQTS Registry, categorized into electrocardiographically affected (corrected QT interval [QTc] ≥470 ms), borderline (QTc 440 to 469 ms), and unaffected (QTc <440 ms) subgroups. The affected versus unaffected adjusted hazard ratio for aborted cardiac arrest or death was 2.65 ( P <0.001) in the age range of 41 to 60 years and 1.23 ( P =0.31) in the age range of 61 to 75 years. The clinical course of study subjects displayed gender differences: Affected LQTS women experienced a significantly higher cumulative event rate (26%) than borderline (16%) and unaffected (12%) women ( P =0.001), whereas event rates were similar among the 3 respective subgroups of men (29%, 26%, and 27%; P =0.16). Recent syncope (<2 years in the past) was the predominant risk factor in affected subjects (hazard ratio 9.92, P <0.001), and the LQT3 genotype was identified as the most powerful predictor of outcome in a subset of 871 study subjects who were genetically tested for a known LQTS mutation (hazard ratio 4.76, P =0.02). Conclusions— LQTS subjects maintain a high risk for life-threatening cardiac events after age 40 years. The phenotypic expression of affected subjects is influenced by age-specific factors related to gender, clinical history, and the LQTS genotype.
Molecular analysis of metaplastic breast carcinoma: high EGFR copy number via aneusomy
Gilbert, Judith A, Reynolds, Carol, Giordano, Karin F., Blair, Hilary, Jenkins, Robert B. , Lingle, Wilma L., Reinholz, Monica M., Adjei, Alex A. , Ames, Matthew M. , Goetz, Matthew P. , Ingle, James N. , Suman, Vera J.

Mayo Clinic

Molecular Cancer Therapeutics | April 15, 2008 | Volume: 7 | Issue: 4 | Pages: 944-951

10.1158/1535-7163.mct-07-0570 | PMID 18413808 Get It

Abstract Metaplastic breast carcinoma, a rare tumor composed of adenocarcinomatous and nonglandular growth patterns, is characterized by a propensity for distant metastases and resistance to standard anticancer therapies. We sought confirmation that this tumor is a basal-like breast cancer, expressing epidermal growth factor receptor (EGFR) and stem cell factor receptor (KIT). EGFR activating mutations and high copy number (associated with response to tyrosine kinase inhibitor gefitinib) and KIT activating mutations (associated with imatinib sensitivity) were then investigated. Seventy-seven metaplastic cases were identified (1976-2006); 38 with tumor blocks available underwent pathologic confirmation before EGFR and KIT immunohistochemical analyses. A tissue microarray of malignant glandular and metaplastic elements was constructed and analyzed immunohistochemically for cytokeratin 5/6, estrogen receptor, progesterone receptor, and p63, and by fluorescence in situ hybridization for EGFR and HER-2/neu. DNA isolated from individual elements was assessed for EGFR and KIT activating mutations. All assessable cases were negative for estrogen receptor, progesterone receptor, and (except one) HER2. The majority were positive for cytokeratin 5/6 (58%), p63 (59%), and EGFR overexpression (66%); 24% were KIT positive. No EGFR or KIT activating mutations were present; 26% of the primary metaplastic breast carcinomas were fluorescence in situ hybridization-positive, displaying high EGFR copy number secondary to aneusomy (22%) and amplification (4%). We report here that metaplastic breast carcinoma is a basal-like breast cancer lacking EGFR and KIT activating mutations but exhibiting high EGFR copy number (primarily via aneusomy), suggesting that EGFR tyrosine kinase inhibitors should be evaluated in this molecular subset of breast carcinomas. [Mol Cancer Ther 2008;7(4):944–51]
Acute Stroke Imaging Research Roadmap
Wintermark, Max , Alexandrov, Andrei V. , Alger, Jeffry R. , Bammer, Roland , Baron, Jean‐Claude , Derdeyn, Colin P. , Donnan, Geoffrey A. , Eastwood, James D., Fiebach, Jochen B. , Fisher, Marc , Furie, Karen L. , Goldmakher, Gregory V., Hacke, Werner, Kidwell, Chelsea S., Kloska, Stephan P. , Köhrmann, Martin , Lee, Ting‐Yim , Lev, Michael H. , Liebeskind, David S. , Østergaard, Leif , Provenzale, James, Schellinger, Peter D. , Sorensen, A. Gregory , Wardlaw, Joanna M. , Wu, Ona , Warach, Steven , Albers, Gregory W. , Davis, Stephen M. , Demaerschalk, Bart M. , Koroshetz, Walter J. , Lees, Kennedy R. , Liebeskind, David S. , Powers, William J. , Silbergleit, Robert , Wardlaw, Joanna Marguerite , Wintermark, Max , Wu, Ona , Derdeyn, Colin P

Mayo Clinic

Stroke | April 10, 2008 | Volume: 39 | Issue: 5 | Pages: 1621-1628

10.1161/strokeaha.107.512319 | PMID 18403743 Get It

The recent “Advanced Neuroimaging for Acute Stroke Treatment” meeting on September 7 and 8, 2007 in Washington DC, brought together stroke neurologists, neuroradiologists, emergency physicians, neuroimaging research scientists, members of the National Institute of Neurological Disorders and Stroke (NINDS), the National Institute of Biomedical Imaging and Bioengineering (NIBIB), industry representatives, and members of the US Food and Drug Administration (FDA) to discuss the role of advanced neuroimaging in acute stroke treatment. The goals of the meeting were to assess state-of-the-art practice in terms of acute stroke imaging research and to propose specific recommendations regarding: (1) the standardization of perfusion and penumbral imaging techniques, (2) the validation of the accuracy and clinical utility of imaging markers of the ischemic penumbra, (3) the validation of imaging biomarkers relevant to clinical outcomes, and (4) the creation of a central repository to achieve these goals. The present article summarizes these recommendations and examines practical steps to achieve them.
In Vitro Activity of Anidulafungin against Candida albicans Biofilms
Jacobson, Melissa, Piper, Kerryl E., Nguyen, Gary, Steckelberg, James M., Patel, Robin , Patel, Robin

Mayo Clinic

Antimicrobial Agents and Chemotherapy | April 7, 2008 | Volume: 52 | Issue: 6 | Pages: 2242-2243

10.1128/aac.00211-08 | PMID 18391031 Get It

ABSTRACT We tested the activity of anidulafungin against 30 Candida albicans isolates. The planktonic MICs for 50 and 90% of the isolates tested (MIC 50 and MIC 90 ) were ≤0.03 and 0.125 μg/ml, respectively (MIC range, ≤0.03 to 2 μg/ml). The sessile MIC 50 and MIC 90 were ≤0.03 and ≤0.03 μg/ml, respectively (MIC range, ≤0.03 to >16 μg/ml).
A Complete Computational Model of Ultrasound Vibro-Acoustography
Malcolm, Alison , Reitich, Fernando, Yang, Jiaqi , Fatemi, Mostafa , Greenleaf, James F. , Fatemi, Mostafa

Mayo Clinic

Advances in Bioengineering, Biomedical and Safety Systems | April 3, 2008 | Volume: No volume available | Issue: No issue available | Pages: 65-71

10.1115/imece2006-16385 Get It

Ultrasound vibro-acoustography is a novel medical imaging modality that combines the high resolution of high-frequency ultrasound with the speckle-free images obtained using low-frequency methods. This imaging modality relies on the non-linear interaction of two high frequency beams at slightly different frequencies. We describe the physics of ultrasound vibro-acoustography and outline a strategy for its modeling, simulation, and optimal design.
Measurement of the Propagation Velocity of Pulse Wave Generated by Ultrasound in Arteries
Zhang, Xiaoming , Greenleaf, James F., Zhang, Xiaoming

Mayo Clinic

Advances in Bioengineering | April 3, 2008 | Volume: No volume available | Issue: No issue available | Pages: 69-70

10.1115/imece2005-79619 Get It

Arterial wall stiffness can be associated with various diseases. The stiffness of an artery can be assessed by measurement of the pulse wave velocity (PWV). Usually, PWV is estimated using the foot-to-foot method. However, the foot of the pressure wave is not very clear due to reflected waves. Also, the blood pressure wave generated by the heart is normally a low frequency wave, hence the time resolution is low. PWV is an average indicator of artery stiffness between two measuring locations, therefore, it is not easy to identify local stiffness. In this paper a short external pulse is generated in an artery by the radiation force of ultrasound. The propagation velocity of the pulse wave is measured along the artery. The temporal resolution of this method, which is in the range of microseconds, is much higher than the conventional pressure PWV method, and therefore allows the wave velocity to be measured accurately over a few millimeters.
Resonance of Rubber Tubes Generated by Air Force Ultrasound Transducers
Zhang, Xiaoming , Greenleaf, James F., Zhang, Xiaoming

Mayo Clinic

Advances in Bioengineering, Biomedical and Safety Systems | April 3, 2008 | Volume: No volume available | Issue: No issue available | Pages: 35-36

10.1115/imece2006-15696 Get It

In paper, we report our recent results of using the air force ultrasound transducer to study the resonance of rubber tubes. Experiments were carried out on a rubber latex tube. Seven resonant frequencies were measured between 50 Hz and 200 Hz. Theoretical calculation of the resonant frequency on the tube was done with the wave propagation approach. The relative differences of the seven resonant frequencies between the experiment and the theory are less than 6 %. This research shows that the air force ultrasound transducer can be used for tube resonance measurement.