Technical Note: Increased photon starvation artifacts at low helical pitch in ultra‐low‐dose CT
Browne, Jacinta E. , Bruesewitz, Michael R. , Vrieze, Thomas J., Yu, Lifeng , Browne, Jacinta , McCollough, Cynthia H. , Yu, Lifeng

Mayo Clinic

Medical Physics | October 3, 2019 | Volume: 46 | Issue: 12 | Pages: 5538-5543

10.1002/mp.13845 | PMID 31580485 Get It

PurposeThe aim of this study was to demonstrate that a low helical pitch causes increased photon starvation artifacts at ultra‐low‐dose CT.MethodsA cylindrical water phantom with a diameter of 30 cm was scanned on two different generation CT scanners: a 64‐slice scanner (Sensation 64, Siemens Healthcare) and a 192‐slice scanner (Somatom Force, Siemens Healthcare) at multiple effective mAs levels (mAs/pitch = 200, 100, 50, 25, and 12). The corresponding CTDIvol values were 4.1, 2.0, 1.0, 0.5 mGy, on the 64‐slice scanner and 3.8, 1.9, 1.0, 0.5 mGy on the 192‐slice scanner, for the selected effective mAs values. For each dose setting, the scan was repeated at four helical pitches: 1.2, 0.9, 0.6, and the lowest achievable pitch on each scanner. The tube current was automatically adjusted by the scanner so that the effective mAs, and thus CTDIvol, were kept the same for different pitches. All CT data sets were reconstructed with a slice thickness of 3mm and a medium smooth kernel. Images acquired at the same dose level but different helical pitches were visually inspected to assess photon starvation artifacts and noise levels.ResultsAt the same radiation dose, image noise increased with the decreasing helical pitch. The increase was more severe on the old‐generation 64‐slice scanner. Photon starvation artifacts were evident at 200 effective mAs on the 64‐slice scanner at 80 kV. On the 192‐slice scanner there was no visible photon starvation artifacts at both 200 and 50 effective mAs (CTDIvol = 4.1 mGy and 1.0 mGy, respectively); nor was there a visible impact from the lower helical pitch. Only when the dose was lowered to be extremely low (~0.26 mGy, achievable at 70 kV), did photon starvation artifacts become evident.ConclusionsA low helical pitch may increase image noise and photon starvation artifacts compared to a higher pitch for the same dose level, particularly at ultra‐low dose CT.
Pooled subgroup analysis of twelve randomized controlled trials of immunotherapy in non-small cell lung cancer.
Adjei, Alex A. , Leventakos, Konstantinos , Li, Rutian , Wang, Lifeng , Liu, Baorui , Molina, Julian R. , Yang, Fang , Wang, Yucai , Mansfield, Aaron S. , Wei, Jia

Mayo Clinic

Journal of Clinical Oncology | May 28, 2019 | Volume: 37 | Issue: 15_suppl | Pages: e20639-e20639

10.1200/jco.2019.37.15_suppl.e20639 Get It

e20639 Background: Multiple randomized controlled trials (RCTs) have shown a robust benefit of immunotherapy with immune checkpoint inhibitors (ICI) in non-small cell lung cancer (NSCLC). We did a meta-analysis to examine the benefit of ICI in various subgroups. Methods: PubMed was searched up to Jan 15, 2019 for RCTs comparing overall survival (OS) between ICI and control (without ICI) arms. Pooled hazard ratio (HR) and 95% confidence interval (CI) was calculated for each subgroup. Interaction tests were done to compare relative benefit between opposed subgroups of interest (eg. men vs women; reported as Pheterogeneity). All analyses were performed with a random effects model in Comprehensive Meta Analysis (v2). Results: Twelve phase 2/3 RCTs involving 7244 patients were included. A significant OS benefit of ICI was found in both squamous and non-squamous histology. Current/former smokers, EGFR wild-type, and KRAS mutant patients had a significant OS benefit from ICI, but never smokers, EGFR mutant, and KRAS wild-type patients did not. An OS benefit of ICI was found in patients with or without baseline brain metastasis, PD-L1 < 1% or ≥1%, men or women, age < 65 or ≥65, and ECOG PS 0 or ≥1. No significant difference of relative benefit from ICI over control was found in patients with different PD-L1 expression, sex, age, or ECOG PS (Table). Conclusions: OS benefit of ICI in NSCLC was associated with a smoking history, wild-type EGFR or KRAS mutation. However, the OS benefit of ICI was seen regardless of histology, PD-L1 expression, sex, age, and ECOG PS. [Table: see text]
Impact of prior information on material decomposition in dual- and multienergy computed tomography
Ren, Liqiang , Tao, Shengzhen , Yu, Lifeng , Rajendran, Kishore , McCollough, Cynthia H , Rajendran, Kishore , McCollough, Cynthia H. , Yu, Lifeng

Mayo Clinic

Journal of Medical Imaging | March 29, 2019 | Volume: 6 | Issue: 01 | Pages: 1

10.1117/1.jmi.6.1.013503 | PMID 30891466 Get It

A deep learning‐ and partial least square regression‐based model observer for a low‐contrast lesion detection task in CT
Gong, Hao , Yu, Lifeng , Dilger, Samantha K. N. , Ren, Liqiang , Zhou, Wei , Dilger, Samantha K, Zhou, Wei , Yu, Lifeng , Leng, Shuai , Fletcher, Joel G. , McCollough, Cynthia H.

Mayo Clinic

Medical Physics | March 20, 2019 | Volume: 46 | Issue: 5 | Pages: 2052-2063

10.1002/mp.13500 | PMID 30889282 Get It

PurposeThis work aims to develop a new framework of image quality assessment using deep learning‐based model observer (DL‐MO) and to validate it in a low‐contrast lesion detection task that involves CT images with patient anatomical background.MethodsThe DL‐MO was developed using the transfer learning strategy to incorporate a pretrained deep convolutional neural network (CNN), a partial least square regression discriminant analysis (PLS‐DA) model and an internal noise component. The CNN was previously trained to achieve the state‐of‐the‐art classification accuracy over a natural image database. The earlier layers of the CNN were used as a deep feature extractor, with the assumption that similarity exists between the CNN and the human visual system. The PLSR model was used to further engineer the deep feature for the lesion detection task in CT images. The internal noise component was incorporated to model the inefficiency and variability of human observer (HO) performance, and to generate the ultimate DL‐MO test statistics. Seven abdominal CT exams were retrospectively collected from the same type of CT scanners. To compare DL‐MO with HO, 12 experimental conditions with varying lesion size, lesion contrast, radiation dose, and reconstruction types were generated, each condition with 154 trials. CT images of a real liver metastatic lesion were numerically modified to generate lesion models with four lesion sizes (5, 7, 9, and 11 mm) and three contrast levels (15, 20, and 25 HU). The lesions were inserted into patient liver images using a projection‐based method. A validated noise insertion tool was used to synthesize CT exams with 50% and 25% of routine radiation dose level. CT images were reconstructed using the weighted filtered back projection algorithm and an iterative reconstruction algorithm. Four medical physicists performed a two‐alternative forced choice (2AFC) detection task (with multislice scrolling viewing mode) on patient images across the 12 experimental conditions. DL‐MO was operated on the same datasets. Statistical analyses were performed to evaluate the correlation and agreement between DL‐MO and HO.ResultsA statistically significant positive correlation was observed between DL‐MO and HO for the 2AFC low‐contrast detection task that involves patient liver background. The corresponding Pearson product moment correlation coefficient was 0.986 [95% confidence interval (0.950, 0.996)]. Bland–Altman agreement analysis did not indicate statistically significant differences.ConclusionsThe proposed DL‐MO is highly correlated with HO in a low‐contrast detection task that involves realistic patient liver background. This study demonstrated the potential of the proposed DL‐MO to assess image quality directly based on patient images in realistic, clinically relevant CT tasks.
Clinical Assessment of Metal Artifact Reduction Methods in Dual-Energy CT Examinations of Instrumented Spines
Long, Zaiyang , Nagelschneider, Alex A. , Michalak, Gregory J. , Yu, Lifeng , DeLone, David R. , Kotsenas, Amy L. , Lehman, Vance T. , Fletcher, Joel G. , McCollough, Cynthia H. , Yu, Lifeng

Mayo Clinic

American Journal of Roentgenology | December 12, 2018 | Volume: 212 | Issue: 2 | Pages: 395-401

10.2214/ajr.18.19757 | PMID 30667317 Get It

Lead Shielding in Pediatric Chest CT: Effect of Apron Placement Outside the Scan Volume on Radiation Dose Reduction
Yu, Lifeng , Bruesewitz, Michael R. , Vrieze, Thomas J., Yu, Lifeng , McCollough, Cynthia H.

Mayo Clinic

American Journal of Roentgenology | November 13, 2018 | Volume: 212 | Issue: 1 | Pages: 151-156

10.2214/ajr.17.19405 | PMID 30422712 Get It

Abstract P-319: QUALITY IMPROVEMENT IN THE GLOBAL PEDIATRIC CRITICAL CARE UNIT: CHECKLIST FOR EARLY RECOGNITION AND TREATMENT OF ACUTE ILLNESS AND INJURY IN PEDIATRICS (CERTAINP) INTERNATIONAL PROJECT
Arteaga, Grace M. , An, Kuznetsov , Gajić, Ognjen, Murthy, S., Cooper, Lindsey, Ren, Hong , Jin, P., Qiao, Lifeng , Ilisapeci, T., Sauduadua, Laila, Wang, T., An, K., Dong, Yue , Kashyap, Rahul , Gajic, Ognjen , Tripathi, Sandeep , Kovačević, Tanja , Basavaraja, Chetak Kadabasal , Ravi, Mandyam Dhati , Jin, P., Zhang, G., Sridharan, Kannan

Mayo Clinic

Pediatric Critical Care Medicine | May 31, 2018 | Volume: 19 | Issue: 6S | Pages: 144-144

10.1097/01.pcc.0000537776.86722.e4 Get It

Evaluation of projection‐ and dual‐energy‐based methods for metal artifact reduction in CT using a phantom study
Long, Zaiyang , Bruesewitz, Michael R. , Amrami, Kimberly K. , Adkins, Mark C., Glazebrook, Katrina N. , Kofler, James M., Halaweish, Ahmed F., Yu, Lifeng , DeLone, David R. , Morris, Jonathan M. , Leng, Shuai , McCollough, Cynthia H. , Fletcher, Joel G. , Yu, Lifeng

Mayo Clinic

Journal of Applied Clinical Medical Physics | May 11, 2018 | Volume: 19 | Issue: 4 | Pages: 252-260

10.1002/acm2.12347 | PMID 29749048 Get It

AbstractObjectivesBoth projection and dual‐energy (DE)‐based methods have been used for metal artifact reduction (MAR) in CT. The two methods can also be combined. The purpose of this work was to evaluate these three MAR methods using phantom experiments for five types of metal implants.Materials and MethodsFive phantoms representing spine, dental, hip, shoulder, and knee were constructed with metal implants. These phantoms were scanned using both single‐energy (SE) and DE protocols with matched radiation output. The SE data were processed using a projection‐based MAR (iMAR, Siemens) algorithm, while the DE data were processed to generate virtual monochromatic images at high keV (Mono+, Siemens). In addition, the DE images after iMAR were used to generate Mono+ images (DE iMAR Mono+). Artifacts were quantitatively evaluated using CT numbers at different regions of interest. Iodine contrast‐to‐noise ratio (CNR) was evaluated in the spine phantom. Three musculoskeletal radiologists and two neuro‐radiologists independently ranked the artifact reduction.ResultsThe DE Mono+ at high keV resulted in reduced artifacts but also lower iodine CNR. The iMAR method alone caused missing tissue artifacts in dental phantom. DE iMAR Mono+ caused wrong CT numbers in close proximity to the metal prostheses in knee and hip phantoms. All musculoskeletal radiologists ranked SE iMAR > DE iMAR Mono+ > DE Mono+ for knee and hip, while DE iMAR Mono+ > SE iMAR > DE Mono+ for shoulder. Both neuro‐radiologists ranked DE iMAR Mono+ > DE Mono+ > SE iMAR for spine and DE Mono+ > DE iMAR Mono+ > SE iMAR for dental.ConclusionsThe SE iMAR was the best choice for the hip and knee prostheses, while DE Mono+ at high keV was best for dental implants and DE iMAR Mono+ was best for spine and shoulder prostheses. Artifacts were also introduced by MAR algorithms.
Inter‐laboratory comparison of channelized hotelling observer computation
Ba, Alexandre, Abbey, Craig K. , Baek, Jongduk , Han, Minah , Balta, Christiana, Brankov, Jovan G. , Massanés, Francesc, Gifford, Howard C. , Veldkamp, Wouter J. H. , Petrov, Dimitar, Marshall, Nicholas , Samuelson, F. W. , Zeng, Rongping , Solomon, Justin B., Samei, Ehsan , Timberg, Pontus, Förnvik, Hannie, Reiser, Ingrid , Yu, Lifeng , Gong, Hao , Bochud, François , Bouwman, Ramona W. , Giron, Irene Hernandez , Solomon, Justin , Yu, Lifeng , Reiser, Ingrid

Mayo Clinic

Medical Physics | April 28, 2018 | Volume: 45 | Issue: 7 | Pages: 3019-3030

10.1002/mp.12940 | PMID 29704868 Get It

PurposeThe task‐based assessment of image quality using model observers is increasingly used for the assessment of different imaging modalities. However, the performance computation of model observers needs standardization as well as a well‐established trust in its implementation methodology and uncertainty estimation. The purpose of this work was to determine the degree of equivalence of the channelized Hotelling observer performance and uncertainty estimation using an intercomparison exercise.Materials and MethodsImage samples to estimate model observer performance for detection tasks were generated from two‐dimensional CT image slices of a uniform water phantom. A common set of images was sent to participating laboratories to perform and document the following tasks: (a) estimate the detectability index of a well‐defined CHO and its uncertainty in three conditions involving different sized targets all at the same dose, and (b) apply this CHO to an image set where ground truth was unknown to participants (lower image dose). In addition, and on an optional basis, we asked the participating laboratories to (c) estimate the performance of real human observers from a psychophysical experiment of their choice. Each of the 13 participating laboratories was confidentially assigned a participant number and image sets could be downloaded through a secure server. Results were distributed with each participant recognizable by its number and then each laboratory was able to modify their results with justification as model observer calculation are not yet a routine and potentially error prone.ResultsDetectability index increased with signal size for all participants and was very consistent for 6 mm sized target while showing higher variability for 8 and 10 mm sized target. There was one order of magnitude between the lowest and the largest uncertainty estimation.ConclusionsThis intercomparison helped define the state of the art of model observer performance computation and with thirteen participants, reflects openness and trust within the medical imaging community. The performance of a CHO with explicitly defined channels and a relatively large number of test images was consistently estimated by all participants. In contrast, the paper demonstrates that there is no agreement on estimating the variance of detectability in the training and testing setting.