Citations

Clear

150 citation(s) found for "Singh, Ravinder".

Commentary
Singh, Ravinder J.

Mayo Clinic

Clinical Chemistry | May 29, 2018 | Volume: 64 | Issue: 6 | Pages: 897-897

10.1373/clinchem.2017.282079 | PMID 29844060 Get It

Serum Cortisol Levels via Radioimmunoassay vs Liquid Chromatography Mass Spectrophotometry in Healthy Control Subjects and Patients With Adrenal Incidentalomas
Huayllas, Martha Katherine Paniagua , Netzel, Brian C., Kater, Cláudio E. , Huayllas, Martha K P , Singh, Ravinder J.

Mayo Clinic

Laboratory Medicine | January 31, 2018 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1093/labmed/lmy005 | PMID 29608696 Get It

Niche point-of-care endocrine testing – Reviews of intraoperative parathyroid hormone and cortisol monitoring
Chen, Li-Sheng, Singh, Ravinder

Mayo Clinic

Critical Reviews in Clinical Laboratory Sciences | January 23, 2018 | Volume: 55 | Issue: 2 | Pages: 115-128

10.1080/10408363.2018.1425975 | PMID 29357735 Get It

High-Resolution, Accurate-Mass (HRAM) Mass Spectrometry Urine Steroid Profiling in the Diagnosis of Adrenal Disorders
Hines, Jolaine M., Bancos, Cristian, Singh, Raman Deep , Avula, Aditya V, Grebe, Stefan K., Singh, Raman D., Bancos, Irina , Young, William F. , Singh, Ravinder J.

Mayo Clinic

Clinical Chemistry | August 16, 2017 | Volume: 63 | Issue: 12 | Pages: 1824-1835

10.1373/clinchem.2017.271106 | PMID 28814383 Get It

Abstract BACKGROUND Steroid profiling is a promising diagnostic tool with adrenal tumors, Cushing syndrome (CS), and disorders of steroidogenesis. Our objective was to develop a multiple-steroid assay using liquid-chromatography, high-resolution, accurate-mass mass spectrometry (HRAM LC-MS) and to validate the assay in patients with various adrenal disorders. METHODS We collected 24-h urine samples from 114 controls and 71 patients with adrenal diseases. An HRAM LC-MS method was validated for quantitative analysis of 26 steroid metabolites in hydrolyzed urine samples. Differences in steroid excretion between patients were analyzed based on Z-score deviation from control reference intervals. RESULTS Limits of quantification were 20 ng/mL. Dilution linearity ranged from 80% to 120% with means of 93% to 110% for all but 2 analytes. Intraassay and interassay imprecision ranged from 3% to 18% for all but 1 analyte. Control women had lower excretion of androgen and glucocorticoid precursors/metabolites than men (P < 0.001), but no difference in mineralocorticoids was seen (P = 0.06). Androgens decreased with age in both sexes (P < 0.001). Compared with patients with adrenocortical adenoma (ACA), patients with adrenocortical carcinoma (ACC) had 11 steroids with increased Z scores, especially tetrahydro-11-deoxycortisol (14 vs 0.5, P < 0.001), pregnanetriol (7.5 vs −0.4, P = 0.001), and 5-pregnenetriol (5.4 vs −0.4, P = 0.01). Steroid profiling also demonstrated metabolite abnormalities consistent with enzymatic defects in congenital adrenal hyperplasia and differences in pituitary vs adrenal CS. CONCLUSIONS Our HRAM LC-MS assay successfully quantifies 26 steroids in urine. The statistically significant differences in steroid production of ACC vs ACA, adrenal vs pituitary CS, and in congenital adrenal hyperplasia should allow for improved diagnosis of patients with these diseases.
Age and Sex Normalization of Intestinal Permeability Measures for the Improved Assessment of Enteropathy in Infancy and Early Childhood
Kosek, Margaret , Lee, Gwenyth O. , Guerrant, Richard L., Ahmed, Tahmeed, Bessong, Pascal , Ali, Asad , Mduma, Estomih , Yori, Pablo Peñataro , Faubion, William A. , Lima, Aldo Â. M. , Olórtegui, Maribel Paredes , Mason, Carl J. , Babji, Sudhir , Qureshi, Shahida, Kosek, Peter, Samie, Amidou , Pascal, John, Shrestha, Sanjaya K. , McCormick, Benjamin , Seidman, Jessica C. , Lang, Dennis, Zaidi, Anita K. M., Caulfield, Laura E. , Gottlieb, Michael , Network, MAL‐ED, Kosek, Margaret N, Haque, Rashidul , Kang, Gagandeep , Ahmed, Tahmeed , Singh, Ravinder J. , Network, MAL‐ED

Mayo Clinic

Journal of Pediatric Gastroenterology and Nutrition | May 3, 2017 | Volume: 65 | Issue: 1 | Pages: 31-39

10.1097/mpg.0000000000001610 | PMID 28644347 Get It

ABSTRACT Objectives: The aim of the study was to describe changes in intestinal permeability in early childhood in diverse epidemiologic settings. Methods: In a birth cohort study, the lactulose:mannitol (L:M) test was administered to 1980 children at 4 time points in the first 24 months of life in 8 countries. Data from the Brazil site with an incidence of diarrhea similar to that seen in the United States and no growth faltering was used as an internal study reference to derive age‐ and sex‐specific z scores for mannitol and lactulose recoveries and the L:M ratio. Results: A total of 6602 tests demonstrated mannitol recovery, lactulose recovery, and the L:M ratio were associated with country, sex, and age. There was heterogeneity in the recovery of both probes between sites with mean mannitol recovery ranging for 1.34% to 5.88%, lactulose recovery of 0.19% to 0.58%, and L:M ratios 0.10 to 0.17 in boys of 3 months of age across different sites. We observed strong sex‐specific differences in both mannitol and lactulose recovery, with boys having higher recovery of both probes. Alterations in intestinal barrier function increased in most sites from 3 to 9 months of age and plateaued or diminished from 9 to 15 months of age. Conclusions: Alterations in recovery of the probes differ markedly in different epidemiologic contexts in children living in the developing world. The rate of change in the L:M‐ z ratio was most rapid and consistently disparate from the reference standard in the period between 6 and 9 months of age, suggesting that this is a critical period of physiologic impact of enteropathy in these populations.
Negligible Thyroid Hormone Content Present in Nonprescription U.S. Weight Loss Products
Seger, Christian, He, Xuemei , Bernet, Victor , Rhee, Connie M. , Leung, Angela M. , Bernet, Victor J, Braverman, Lewis E. , Yeh, Michael W. , Singh, Ravinder J. , Leung, Angela M

Mayo Clinic

Thyroid® | November 29, 2016 | Volume: 27 | Issue: 2 | Pages: 300-301

10.1089/thy.2016.0534 | PMID 27897088 Get It

Vitamin D-Mediated Hypercalcemia: Mechanisms, Diagnosis, and Treatment
Tebben, Peter J. , Singh, Ravinder J. , Kumar, Rajiv , Tebben, Peter

Mayo Clinic

Endocrine Reviews | September 2, 2016 | Volume: 37 | Issue: 5 | Pages: 521-547

10.1210/er.2016-1070 | PMID 27588937 Get It

Abstract Hypercalcemia occurs in up to 4% of the population in association with malignancy, primary hyperparathyroidism, ingestion of excessive calcium and/or vitamin D, ectopic production of 1,25-dihydroxyvitamin D [1,25(OH)2D], and impaired degradation of 1,25(OH)2D. The ingestion of excessive amounts of vitamin D3 (or vitamin D2) results in hypercalcemia and hypercalciuria due to the formation of supraphysiological amounts of 25-hydroxyvitamin D [25(OH)D] that bind to the vitamin D receptor, albeit with lower affinity than the active form of the vitamin, 1,25(OH)2D, and the formation of 5,6-trans 25(OH)D, which binds to the vitamin D receptor more tightly than 25(OH)D. In patients with granulomatous disease such as sarcoidosis or tuberculosis and tumors such as lymphomas, hypercalcemia occurs as a result of the activity of ectopic 25(OH)D-1-hydroxylase (CYP27B1) expressed in macrophages or tumor cells and the formation of excessive amounts of 1,25(OH)2D. Recent work has identified a novel cause of non-PTH-mediated hypercalcemia that occurs when the degradation of 1,25(OH)2D is impaired as a result of mutations of the 1,25(OH)2D-24-hydroxylase cytochrome P450 (CYP24A1). Patients with biallelic and, in some instances, monoallelic mutations of the CYP24A1 gene have elevated serum calcium concentrations associated with elevated serum 1,25(OH)2D, suppressed PTH concentrations, hypercalciuria, nephrocalcinosis, nephrolithiasis, and on occasion, reduced bone density. Of interest, first-time calcium renal stone formers have elevated 1,25(OH)2D and evidence of impaired 24-hydroxylase-mediated 1,25(OH)2D degradation. We will describe the biochemical processes associated with the synthesis and degradation of various vitamin D metabolites, the clinical features of the vitamin D-mediated hypercalcemia, their biochemical diagnosis, and treatment.
Improving the detection of environmental enteric dysfunction: a lactulose, rhamnose assay of intestinal permeability in children aged under 5 years exposed to poor sanitation and hygiene
Faubion, William A. , Camilleri, Michael , Kelly, Paul , Amadi, Beatrice , Kosek, Margaret , Larson, Jenifer, Grover, Madhusudan , Boe, Gwen M., Dyer, Roy B. , Murray, Joseph A. , Enders, Felicity , Singh, Ravinder J.

Mayo Clinic

BMJ Global Health | July 4, 2016 | Volume: 1 | Issue: 1 | Pages: e000066

10.1136/bmjgh-2016-000066 | PMID 28588929 Get It

Background Environmental enteric dysfunction (EED) is an asymptomatic intestinal disorder affecting populations living in conditions of poor sanitation and hygiene. The study tested intestinal barrier function in infants with EED. Methods We prospectively studied an advanced high-performance liquid chromatography mass spectrometry assay of urine collected after oral intake of the monosaccharide, L-rhamnose and the disaccharide, lactulose, in 112 children from three continents. Findings Compared to the US cohort (n=27), the cohorts of children from Peru (n=19) and Zambia (n=85) were older with evidence of growth impairment. The median (range) of age (months) was 8.0 (2.0 to 13.0), 27.0 (15.0 to 29.0) and 21.0 (12.0 to 36.0), respectively. The median (range) of height for age Z score was −0.1 (−1.8 to 2.4), −1.8 (−3.3 to −0.2) and −2.3 (−8.5 to 1.2), respectively. Among children with valid sugar data (n=22 USA, n=19 Peru, n=73 Zambia), there were no significant differences in the median rhamnose urine concentrations between the three groups. The median (range) lactulose concentration (µg/mL) was 6.78 (0.29 to 31.90), 47.60 (4.23 to 379.00) and 75.40 (0.67 to 873.00) in the US, Peruvian and Zambian cohorts, respectively (p<0.001). The lactulose/rhamnose ratio (LRR) was higher in cohorts from Peru (0.75, 0.15, 5.02) and Zambia (2.26, 0.08, 14.48) compared to the US (0.14, 0.06, 1.00) cohort (p<0.001). In a multivariate effect modification model, higher weight-for-age z scores were associated with lower post-dose lactulose when rhamnose excretion was constant (p=0.003). Conclusions This non-invasive two saccharide permeability protocol measures changes in intestinal permeability in children with EED and permits the identification of individuals for interventional trials.
Commentary
Kaur, Parmpreet, Singh, Ravinder J.

Mayo Clinic

Clinical Chemistry | June 29, 2016 | Volume: 62 | Issue: 7 | Pages: 928-928

10.1373/clinchem.2015.253484 | PMID 27354567 Get It

13C mannitol as a novel biomarker for measurement of intestinal permeability
Grover, Madhusudan , Camilleri, Michael , Hines, Jolaine, Burton, Duane D. , Ryks, Michael, Wadhwa, Abhishek , Sundt, Wendy, Dyer, Roy B. , Singh, Ravinder

Mayo Clinic

Neurogastroenterology & Motility | February 26, 2016 | Volume: 28 | Issue: 7 | Pages: 1114-1119

10.1111/nmo.12802 | PMID 26914765 Get It

AbstractBackgroundGastrointestinal (GI) and non‐GI disorders are associated with altered intestinal permeability, which can be measured in vivo by urinary excretion after oral lactulose and mannitol ingestion. Inadvertent dietary consumption of 12Carbon (12C, regular) mannitol in food or from other sources may interfere with the test's interpretation. 13Carbon (13C) constitutes 1% of carbon in nature and 13C mannitol is a stable isotope. Our aim was to determine the performance of 13C mannitol for measurement of intestinal permeability.MethodsTen healthy volunteers underwent intestinal permeability assay using coadministered 12C mannitol, 13C mannitol and lactulose, followed by timed urine collections. Urinary sugar concentrations were measured using tandem high performance liquid chromatography–mass spectrometry.Key resultsWe found that 13C mannitol can be distinguishable from 12C mannitol on tandem mass spectrometry. In addition, 13C mannitol had ~20‐fold lower baseline contamination compared to 12C mannitol. We describe here the 13C mannitol assay method for the measurement of intestinal permeability.Conclusions & InferencesIn conclusion, 13C mannitol is superior to 12C mannitol for measurement of intestinal permeability. It avoids issues with baseline contamination and erratic excretions during the testing period.