Citations

Clear

131 citation(s) found for "Morrey, BF".

Comparison of the hospital costs for two-stage reimplantation for deep infection, single-stage revision and primary total elbow arthroplasty
Wagner, Eric R. , Ransom, Jeanine E. , Kremers, Hilal Maradit , Morrey, Mark, Sanchez-Sotelo, Joaquin, Morrey, Mark E. , Sánchez‐Sotelo, Joaquín , Wagner, Eric R , Maradit Kremers, Hilal

Mayo Clinic

Shoulder & Elbow | May 8, 2017 | Volume: 9 | Issue: 4 | Pages: 279-284

10.1177/1758573217706364 | PMID 28932285 Get It

Background The purpose of the present study was to determine the cost of two-stage reimplantation for the treatment of deep infection after total elbow arthroplasty (TEA) and compare this with primary and aseptic revision TEA. Methods Three hundred and seventy-one primary TEA and 286 revision TEAs (including 47 elbows requiring two-stage reimplantation) were performed. Total direct medical costs during each hospitalization were obtained from our institutional research database and compared for three groups: primary TEA, revision for nonseptic reasons and two-stage reimplantation for deep infection. Results The mean cost of an uncomplicated primary TEA and aseptic revision TEA was $18,464 and $18,796, respectively. The mean overall cost associated with two-stage reimplantation increased to $34,286. Two-stage reimplantation increased both Part A (hospital costs) and Part B (professional costs). The mean Part A cost for septic revision TEA was $29,102 versus $15,844 for primary TEA. The mean Part B cost for septic revision TEA was $5,184 versus $2,621 for primary TEA. Conclusions Two-stage reimplantation for treatment of an infected TEA costs 186% the hospital cost of a primary uncomplicated or aseptic revision TEA. The overall cost to society is even greater if we take into account the cost of antibiotic therapy in between stages and lost days from work.
Intra-articular implantation of collagen scaffold carriers is safe in both native and arthrofibrotic rabbit knee joints
Walker, Justin A. , Ewald, Timothy J., Lewallen, Eric A. , Wijnen, André J. van , Hanssen, Arlen D. , Morrey, B.F. , Morrey, Mark E. , Abdel, Matthew P. , Sánchez‐Sotelo, Joaquín , van Wijnen, Andre J

Mayo Clinic

Bone & Joint Research | March 28, 2017 | Volume: 6 | Issue: 3 | Pages: 162-171

10.1302/2046-3758.63.bjr-2016-0193 | PMID 28347978 Get It

Objectives Sustained intra-articular delivery of pharmacological agents is an attractive modality but requires use of a safe carrier that would not induce cartilage damage or fibrosis. Collagen scaffolds are widely available and could be used intra-articularly, but no investigation has looked at the safety of collagen scaffolds within synovial joints. The aim of this study was to determine the safety of collagen scaffold implantation in a validated in vivo animal model of knee arthrofibrosis. Materials and Methods A total of 96 rabbits were randomly and equally assigned to four different groups: arthrotomy alone; arthrotomy and collagen scaffold placement; contracture surgery; and contracture surgery and collagen scaffold placement. Animals were killed in equal numbers at 72 hours, two weeks, eight weeks, and 24 weeks. Joint contracture was measured, and cartilage and synovial samples underwent histological analysis. Results Animals that underwent arthrotomy had equivalent joint contractures regardless of scaffold implantation (-13.9° versus -10.9°, equivalence limit 15°). Animals that underwent surgery to induce contracture did not demonstrate equivalent joint contractures with (41.8°) or without (53.9°) collagen scaffold implantation. Chondral damage occurred in similar rates with (11 of 48) and without (nine of 48) scaffold implantation. No significant difference in synovitis was noted between groups. Absorption of the collagen scaffold occurred within eight weeks in all animals Conclusion Our data suggest that intra-articular implantation of a collagen sponge does not induce synovitis or cartilage damage. Implantation in a native joint does not seem to induce contracture. Implantation of the collagen sponge in a rabbit knee model of contracture may decrease the severity of the contracture. Cite this article: J. A. Walker, T. J. Ewald, E. Lewallen, A. Van Wijnen, A. D. Hanssen, B. F. Morrey, M. E. Morrey, M. P. Abdel, J. Sanchez-Sotelo. Intra-articular implantation of collagen scaffold carriers is safe in both native and arthrofibrotic rabbit knee joints. Bone Joint Res 2016;6:162–171. DOI: 10.1302/2046-3758.63.BJR-2016-0193.
A Profile of Glenohumeral Internal and External Rotation Motion in the Uninjured High School Baseball Pitcher, Part II: Strength
Hurd, Wendy J., Kaplan, Kevin, ElAttrache, Neal S., Jobe, Frank W., Morrey, B.F. , Kaufman, Kenton R.

Mayo Clinic

Journal of Athletic Training | March 2, 2017 | Volume: 46 | Issue: 3 | Pages: 289-295

10.4085/1062-6050-46.3.289 | PMID 21669099 Get It

Context: A database describing the range of normal rotator cuff strength values in uninjured high school pitchers has not been established. Chronologic factors that contribute to adaptations in strength also have not been established. Objectives: To establish a normative profile of rotator cuff strength in uninjured high school baseball pitchers and to determine whether bilateral differences in rotator cuff strength are normal findings in this age group. Design: Cohort study. Setting: Baseball playing field. Patients or Other Participants: A total of 165 uninjured male high school baseball pitchers (age = 16 ± 1 years, height = 1.8 ± 0.1 m, mass = 76.8 ± 10.1 kg, pitching experience = 7 ± 2 years). Main Outcome Measure(s): Isometric rotator cuff strength was measured bilaterally with a handheld dynamometer. We calculated side-to-side differences in strength (external rotation [ER], internal rotation [IR], and the ratio of ER:IR at 90° of abduction), differences in strength by age, and the influence of chronologic factors (participant age, years of pitching experience) on limb strength. Results: Side-to-side differences in strength were found for ER, IR, and ER:IR ratio at 90° of abduction. Age at the time of testing was a significant but weak predictor of both ER strength (R2 = 0.032, P = .02) and the ER:IR ratio (R2 = 0.051, P = .004) at 90° of abduction. Conclusions: We established a normative profile of rotator cuff strength for the uninjured high school baseball pitcher that might be used to assist clinicians and researchers in the interpretation of muscle strength performance in this population. These data further suggested that dominant-limb adaptations in rotator cuff strength are a normal finding in this age group and did not demonstrate that these adaptations were a consequence of the age at the time of testing or the number of years of pitching experience.
A Profile of Glenohumeral Internal and External Rotation Motion in the Uninjured High School Baseball Pitcher, Part I: Motion
Hurd, Wendy J., Kaplan, Kevin, ElAttrache, Neal S., Jobe, Frank W., Morrey, B.F. , Kaufman, Kenton R.

Mayo Clinic

Journal of Athletic Training | March 2, 2017 | Volume: 46 | Issue: 3 | Pages: 282-288

10.4085/1062-6050-46.3.282 | PMID 21669098 Get It

Context: The magnitude of motion that is normal for the throwing shoulder in uninjured baseball pitchers has not been established. Chronologic factors contributing to adaptations in motion present in the thrower's shoulder also have not been established. Objectives: To develop a normative profile of glenohumeral rotation motion in uninjured high school baseball pitchers and to evaluate the effect of chronologic characteristics on the development of adaptations in shoulder rotation motion. Design: Cohort study. Setting: Baseball playing field. Patients or Other Participants: A total of 210 uninjured male high school baseball pitchers (age = 16±1.1 years, height = 1.8 + 0.1 m, mass = 77.5±11.2 kg, pitching experience = 6±2.3 years). Intervention(s): Using standard goniometric techniques, we measured passive rotational glenohumeral range of motion bilaterally with participants in the supine position. Main Outcome Measure(s): Paired t tests were performed to identify differences in motion between limbs for the group. Analysis of variance and post hoc Tukey tests were conducted to identify differences in motion by age. Linear regressions were performed to determine the influence of chronologic factors on limb motion. Results: Rotation motion characteristics for the population were established. We found no difference between sides for external rotation (ER) at 0° of abduction (t209 = 0.658, P = .51), but we found side-to-side differences in ER (t209 = −13.012, P<.001) and internal rotation (t209 = 15.304, P<.001) at 90° of abduction. Age at the time of testing was a significant negative predictor of ER motion for the dominant shoulder (R2 = 0.019, P = .049) because less ER motion occurred at the dominant shoulder with advancing age. We found no differences in rotation motion in the dominant shoulder across ages (F4,205 range, 0.451–1.730, P>.05). Conclusions: This range-of-motion profile might be used to assist with the interpretation of normal and atypical shoulder rotation motion in this population. Chronologic characteristics of athletes had no influence on range-of-motion adaptations in the thrower's shoulder.
Primary Linked Semiconstrained Total Elbow Arthroplasty for Rheumatoid Arthritis
Baghdadi, Yaser M. K., Morrey, B.F. , Sanchez-Sotelo, Joaquin, Morrey, Bernard F, Sánchez‐Sotelo, Joaquín

Mayo Clinic

Journal of Bone and Joint Surgery | October 19, 2016 | Volume: 98 | Issue: 20 | Pages: 1741-1748

10.2106/jbjs.15.00649 | PMID 27869626 Get It

Background: Elbow arthroplasty is the treatment of choice for end-stage rheumatoid arthritis (RA). The purpose of this study was to determine the long-term outcome of a linked semiconstrained elbow arthroplasty implant design in patients with RA. Methods: Between 1982 and 2006, 461 primary total elbow arthroplasties using the Coonrad-Morrey prosthesis were performed in 387 patients with RA. Fifty-five of the arthroplasties were performed to treat concurrent traumatic or posttraumatic conditions. There were 305 women (365 elbows, 79%) and 82 men (96 elbows, 21%). Ten patients (10 elbows) were lost to follow-up, 9 patients (10 elbows) died, and 6 patients (6 elbows) underwent revision surgery within the first 2 years. For the 435 elbows (362 patients, 94%) with a minimum of 2 years of follow-up, the median follow-up was 10 years (range, 2 to 30 years). Results: At the most recent follow-up, 49 (11%) of the elbows had undergone component revision or removal (deep infection, 10 elbows; and mechanical failure, 39 elbows). Eight additional elbows were considered to have radiographic evidence of loosening. For surviving implants followed for a minimum of 2 years, the median Mayo Elbow Performance Score (MEPS) was 90 points. Bushing wear was identified in 71 (23%) of the surviving elbows with a minimum of 2 years of radiographic follow-up; however, only 2% of the elbows had been revised for isolated bushing wear. The rate of survivorship free of implant revision or removal for any reason was 92% (95% confidence interval [CI] = 88% to 94%) at 10 years, 83% (95% CI = 77% to 88%) at 15 years, and 68% (95% CI = 56% to 78%) at 20 years. The survivorship at 20 years was 88% (95% CI = 83% to 92%) with revision due to aseptic loosening as the end point and 89% (95% CI = 77% to 95%) with isolated bushing exchange as the end point. Risk factors for implant revision for any cause included male sex, a history of concomitant traumatic pathology, and implantation of an ulnar component with a polymethylmethacrylate surface finish. Conclusions: Elbow arthroplasty using a cemented linked semiconstrained elbow arthroplasty provides satisfactory clinical results in the treatment of RA with a reasonable rate of survivorship free of mechanical failure at 20 years. Although bushing wear was identified on radiographs in approximately one-fourth of the patients, revision for isolated bushing wear was uncommon. Level of Evidence: Therapeutic Level IV . See Instructions for Authors for a complete description of levels of evidence.
Prosthesis Design and Stress Profile after Hip Resurfacing: A Finite Element Analysis
Heijink, Andras, Zobitz, M. E., Nuyts, Rudy M. M. A., Morrey, BF, An, K-N, Morrey, BF, An, K-N.

Mayo Clinic

Journal of Orthopaedic Surgery | October 4, 2016 | Volume: 16 | Issue: 3 | Pages: 326-332

10.1177/230949900801600312 | PMID 19126900 Get It

Purpose. To evaluate the effect of prosthesis design on stress profile in the proximal femur after hip resurfacing. Methods. The von Mises stress profile of the native femur was simulated and compared with that of resurfaced femurs using various prosthetic materials (titanium, cobalt-chrome, ceramic), stem lengths (normal, half, short, and no stem), and femoral head coverage (shell size) [260°, 220°, 180°, and 140°]. Results. Hip resurfacing altered the stress profile of the cancellous (but not cortical) bone of the femoral neck. Maximal cortical stresses were observed at the posterior half of the medial femoral neck. The stress profile of the native femur was most similar to that of the resurfaced femur made of titanium, with a short or no stem and 260 degrees of femoral head coverage (shell size). Conclusion. Optimising prosthesis design by minimising biomechanical alterations seems a valid approach to achieving favourable long-term outcomes. Cadaveric and in vivo studies are needed to confirm the clinical relevance and feasibility.
Safety of Intra-Articular Implantation of Oligo[Poly(ethylene glycol) Fumarate] Scaffolds into the Rabbit Knee
Ewald, Timothy J., Walker, Justin A. , Lewallen, Eric A. , Trousdale, William H. , Yaszemski, Michael J. , Hanssen, Arlen D. , Morrey, B.F. , Wijnen, André J. van , Morrey, Bernard F, van Wijnen, Andre J, Sanchez-Sotelo, Joaquin, Sánchez‐Sotelo, Joaquín , Morrey, Mark E. , Abdel, Matthew P. , van Wijnen, Andre J

Mayo Clinic

Tissue Engineering Part C: Methods | September 27, 2016 | Volume: 22 | Issue: 10 | Pages: 991-998

10.1089/ten.tec.2016.0209 | PMID 27673559 Get It

Character Development and Physical Activity
Morrey, Michael A.

Mayo Clinic

The Sport Psychologist | August 10, 2016 | Volume: 10 | Issue: 3 | Pages: 296-297

10.1123/tsp.10.3.296 Get It

Infection in total elbow arthroplasty with stable components
Streubel, P. N., Simone, Juan Pablo , Morrey, B.F. , Sánchez‐Sotelo, Joaquín , Morrey, Mark E.

Mayo Clinic

The Bone & Joint Journal | June 30, 2016 | Volume: 98-B | Issue: 7 | Pages: 976-983

10.1302/0301-620x.98b7.36397 | PMID 27365477 Get It

AimsWe describe the use of a protocol of irrigation and debridement (I& D) with retention of the implant for the treatment of periprosthetic infection of a total elbow arthroplasty (TEA). This may be an attractive alternative to staged re-implantation.Patients and MethodsBetween 1990 and 2010, 23 consecutive patients were treated in this way. Three were lost to follow-up leaving 20 patients (21 TEAs) in the study. There were six men and 14 women. Their mean age was 58 years (23 to 76). The protocol involved: component unlinking, irrigation and debridement (I& D), and the introduction of antibiotic laden cement beads; organism-specific intravenous antibiotics; repeat I& D and re-linkage of the implant if appropriate; long-term oral antibiotic therapy.ResultsThe mean follow-up was 7.1 years (2 to 16). The infecting micro-organisms were Staphylococcus aureus in nine, coagulase-negative Staphylococcus in 13, Corynebacterium in three and other in six cases. Re-operations included three repeat staged I& Ds, two repeat superficial I& Ds and one fasciocutaneous forearm flap. One patient required removal of the implant due to persistent infection. All except three patients rated their pain as absent or mild. Outcome was rated as good or excellent in 15 patients (mean Mayo Elbow Performance Score 78 points, (5 to 100) with a mean flexion-extension arc of 103° (40° to 150°)).ConclusionA staged protocol can be successful in retaining stable components of an infected TEA. Function of the elbow may compare unfavourably to that after an uncomplicated TEA. Cite this article: Bone Joint J 2016;98-B:976–83.
Complex elbow instability: surgical management of elbow fracture dislocations
Sánchez‐Sotelo, Joaquín , Morrey, Mark E. , Morrey, Mark

Mayo Clinic

EFORT Open Reviews | May 31, 2016 | Volume: 1 | Issue: 5 | Pages: 183-190

10.1302/2058-5241.1.000036 | PMID 28461946 Get It

Abstract There are three main patterns of complex elbow instability: posterolateral (terrible triad), varus posteromedial (anteromedial coronoid fracture with lateral collateral ligament complex disruption), and trans-olecranon fracture dislocations. Radial head fractures, in the setting of complex elbow instability, often require internal fixation or arthroplasty; the outcome of radial head replacement is dictated by adequate selection of the head diameter, correct restoration of radial length, and proper alignment and tracking. Small coronoid fractures can be ignored. Larger coronoid fractures, especially those involving the anteromedial facet, require fixation or graft reconstruction, particularly in the presence of incongruity. The lateral collateral ligament complex should be repaired whenever disrupted. Medial collateral ligament disruptions seem to heal reliably without surgical repair provided all other involved structures are addressed. The most common mistakes in the management of trans-olecranon fracture dislocations are suboptimal fixation, lack of fixation of coronoid fragments, and lack of restoration of the natural dorsal angulation of the ulna. Cite this article: Sanchez-Sotelo J, Morrey M. Complex elbow instability. EFORT Open Rev 2016;1:183-190.