Citations

Clear

142 citation(s) found for "Mandrekar, Jayawant".

Activity of Tedizolid in Methicillin-Resistant Staphylococcus aureus Experimental Foreign Body-Associated Osteomyelitis
Park, Kyung‐Hwa , Greenwood‐Quaintance, Kerryl E. , Mandrekar, Jayawant N. , Patel, Robin , Mandrekar, Jayawant, Patel, Robin

Mayo Clinic

Antimicrobial Agents and Chemotherapy | August 23, 2016 | Volume: 60 | Issue: 11 | Pages: 6568-6572

10.1128/aac.01248-16 | PMID 27550347 Get It

ABSTRACT We compared tedizolid alone and tedizolid with rifampin to rifampin and vancomycin plus rifampin in a rat model of methicillin-resistant Staphylococcus aureus (MRSA) foreign body-associated osteomyelitis. The study strain was a prosthetic joint infection-associated isolate. Steady-state pharmacokinetics for intraperitoneal administration of tedizolid, vancomycin, and rifampin were determined in uninfected rats. MRSA was inoculated into the proximal tibia, and a wire was implanted. Four weeks later, the rats were treated intraperitoneally for 21 days with tedizolid ( n = 14), tedizolid plus rifampin ( n = 11), rifampin ( n = 16), or vancomycin plus rifampin ( n = 13). Seventeen rats received no treatment. After treatment, quantitative bone cultures were performed. Blood was obtained for determination of drug trough concentrations in the tedizolid and tedizolid plus rifampin groups. The mean peak plasma concentration and mean area under the concentration-time curve from time zero to 24 h for tedizolid were 12 μg/ml and 60 μg · h/ml, respectively. The bacterial loads in all treatment groups were significantly lower than those in the control group; those in the tedizolid- plus rifampin-treated animals were not significantly different from those in the vancomycin- plus rifampin-treated animals. The range of mean plasma trough concentrations in the tedizolid group was 0.44 to 0.73 μg/ml. Although neither tedizolid nor vancomycin resistance was detected in isolates recovered from bones, rifampin resistance was detected in 10 animals (63%) in the rifampin group, 8 animals (73%) in the tedizolid plus rifampin group, and a single animal (8%) in the vancomycin plus rifampin group. Tedizolid alone or tedizolid combined with rifampin was active in a rat model of MRSA foreign body-associated osteomyelitis. The emergence of rifampin resistance was noted in animals receiving tedizolid plus rifampin.
Direct Electrical Current Reduces Bacterial and Yeast Biofilm Formation
Ruiz‐Ruigómez, María , Badiola, Jon , Schmidt-Malan, Suzannah M., Greenwood‐Quaintance, Kerryl E. , Karau, Melissa J. , Brinkman, Cassandra L., Mandrekar, Jayawant N. , Greenwood-Quaintance, Kerryl, Patel, Robin

Mayo Clinic

International Journal of Bacteriology | March 17, 2016 | Volume: 2016 | Issue: No issue available | Pages: 1-6

10.1155/2016/9727810 | PMID 27073807 Get It

New strategies are needed for prevention of biofilm formation. We have previously shown that 24 hr of 2,000 µA of direct current (DC) reducesStaphylococcus epidermidisbiofilm formationin vitro. Herein, we examined the effect of a lower amount of DC exposure onS. epidermidis,Staphylococcus aureus,Escherichia coli,Pseudomonas aeruginosa,Propionibacterium acnes, andCandida albicansbiofilm formation. 12 hr of 500 µA DC decreasedS. epidermidis,S. aureus,E. coli, andP. aeruginosabiofilm formation on Teflon discs by 2, 1, 1, and 2 log10cfu/cm2, respectively (p<0.05). Reductions inS. epidermidis,S. aureus, andE. colibiofilm formation were observed with as few as 12 hr of 200 µA DC (2, 2 and 0.4 log10 cfu/cm2, resp.); a 1 log10 cfu/cm2reduction inP. aeruginosabiofilm formation was observed at 36 hr. 24 hr of 500 µA DC decreasedC. albicansbiofilm formation on Teflon discs by 2 log10 cfu/cm2. No reduction inP. acnesbiofilm formation was observed. 1 and 2 log10 cfu/cm2reductions inE. coliandS. epidermidisbiofilm formation on titanium discs, respectively, were observed with 12 hr of exposure to 500 µA. Electrical current is a potential strategy to reduce biofilm formation on medical biomaterials.
Improved Diagnosis of Prosthetic Joint Infection by Culturing Periprosthetic Tissue Specimens in Blood Culture Bottles
Peel, Trisha , Dylla, Brenda L., Lynch, David T. , Greenwood‐Quaintance, Kerryl E. , Cheng, Allen , Mandrekar, Jayawant N. , Patel, Robin , Peel, Trisha N, Hughes, John G, Hughes, John , Patel, Robin

Mayo Clinic

mBio | January 29, 2016 | Volume: 7 | Issue: 1 | Pages: No page available

10.1128/mbio.01776-15 | PMID 26733067 Get It

ABSTRACT Despite known low sensitivity, culture of periprosthetic tissue specimens on agars and in broths is routine. Culture of periprosthetic tissue samples in blood culture bottles (BCBs) is potentially more convenient, but it has been evaluated in a limited way and has not been widely adopted. The aim of this study was to compare the sensitivity and specificity of inoculation of periprosthetic tissue specimens into blood culture bottles with standard agar and thioglycolate broth culture, applying Bayesian latent class modeling (LCM) in addition to applying the Infectious Diseases Society of America (IDSA) criteria for prosthetic joint infection. This prospective cohort study was conducted over a 9-month period (August 2013 to April 2014) at the Mayo Clinic, Rochester, MN, and included all consecutive patients undergoing revision arthroplasty. Overall, 369 subjects were studied; 117 (32%) met IDSA criteria for prosthetic joint infection, and 82% had late chronic infection. Applying LCM, inoculation of tissues into BCBs was associated with a 47% improvement in sensitivity compared to the sensitivity of conventional agar and broth cultures (92.1 versus 62.6%, respectively); this magnitude of change was similar when IDSA criteria were applied (60.7 versus 44.4%, respectively; P = 0.003). The time to microorganism detection was shorter with BCBs than with standard media ( P < 0.0001), with aerobic and anaerobic BCBs yielding positive results within a median of 21 and 23 h, respectively. Results of our study demonstrate that the semiautomated method of periprosthetic tissue culture in blood culture bottles is more sensitive than and as specific as agar and thioglycolate broth cultures and yields results faster. IMPORTANCE Prosthetic joint infections are a devastating complication of arthroplasty surgery. Despite this, current microbiological techniques to detect and diagnose infections are imperfect. This study examined a new approach to diagnosing infections, through the inoculation of tissue samples from around the prosthetic joint into blood culture bottles. This study demonstrated that, compared to current laboratory practices, this new technique increased the detection of infection. These findings are important for patient care to allow timely and accurate diagnosis of infection.
Antibiofilm Activity of Electrical Current in a Catheter Model
Voegele, Paul, Badiola, Jon , Schmidt-Malan, Suzannah M., Karau, Melissa J. , Greenwood‐Quaintance, Kerryl E. , Mandrekar, Jayawant N. , Patel, Robin , Patel, Robin

Mayo Clinic

Antimicrobial Agents and Chemotherapy | December 29, 2015 | Volume: 60 | Issue: 3 | Pages: 1476-1480

10.1128/aac.01628-15 | PMID 26711752 Get It

ABSTRACT Catheter-associated infections are difficult to treat with available antimicrobial agents because of their biofilm etiology. We examined the effect of low-amperage direct electrical current (DC) exposure on established bacterial and fungal biofilms in a novel experimental in vitro catheter model. Staphylococcus epidermidis , Staphylococcus aureus , Escherichia coli , Pseudomonas aeruginosa , and Candida parapsilosis biofilms were grown on the inside surfaces of polyvinyl chloride (PVC) catheters, after which 0, 100, 200, or 500 μA of DC was delivered via intraluminally placed platinum electrodes. Catheter biofilms and intraluminal fluid were quantitatively cultured after 24 h and 4 days of DC exposure. Time- and dose-dependent biofilm killing was observed with all amperages and durations of DC administration. Twenty-four hours of 500 μA of DC sterilized the intraluminal fluid for all bacterial species studied; no viable bacteria were detected after treatment of S. epidermidis and S. aureus biofilms with 500 μA of DC for 4 days.
Evaluation of a Genus- and Group-Specific Rapid PCR Assay Panel on Synovial Fluid for Diagnosis of Prosthetic Knee Infection
Melendez, Dante P. , Greenwood‐Quaintance, Kerryl E. , Berbari, Elie F. , Osmon, Douglas R. , Mandrekar, Jayawant N. , Hanssen, Arlen D. , Patel, Robin , Patel, Robin

Mayo Clinic

Journal of Clinical Microbiology | November 5, 2015 | Volume: 54 | Issue: 1 | Pages: 120-126

10.1128/jcm.02302-15 | PMID 26537446 Get It

ABSTRACT We evaluated a genus- and group-specific PCR assay panel using 284 prosthetic knee synovial fluid samples collected from patients presenting to our institution with implant failure. Using the Musculoskeletal Infection Society diagnostic criteria, 88 and 196 samples were classified as showing prosthetic joint infection (PJI) and aseptic failure (AF), respectively. Sensitivities of the synovial fluid PCR panel and culture were 55.6% and 76.1% ( P ≤ 0.001), respectively, and specificities were 91.8% and 97.4% ( P = 0.016), respectively. Among the 70 subjects who had received antibiotics within the month preceding synovial fluid aspiration (48 of whom had PJI), PCR panel and synovial fluid culture sensitivities were 64.5% and 85.4%, respectively ( P < 0.0001). In this group, the PCR panel detected Staphylococcus aureus in two culture-negative PJI cases. Overall, the evaluated molecular diagnostic tool had low sensitivity when applied to synovial fluid.
Evaluation of the FilmArray Blood Culture ID Panel on Biofilms Dislodged from Explanted Arthroplasties for Prosthetic Joint Infection Diagnosis
Vasoo, Shawn , Cunningham, Scott A. , Greenwood‐Quaintance, Kerryl E. , Mandrekar, Jayawant N. , Hanssen, Arlen D. , Osmon, Douglas R. , Berbari, Elie F. , Patel, Robin , Abdel, Matthew P. , Patel, Robin , Cunningham, Scott A

Mayo Clinic

Journal of Clinical Microbiology | May 28, 2015 | Volume: 53 | Issue: 8 | Pages: 2790-2792

10.1128/jcm.01333-15 | PMID 26019200 Get It

Antibiofilm Activity of Low-Amperage Continuous and Intermittent Direct Electrical Current
Schmidt-Malan, Suzannah M., Karau, Melissa J. , Cede, Julia , Greenwood‐Quaintance, Kerryl E. , Brinkman, Cassandra L., Mandrekar, Jayawant N. , Patel, Robin , Patel, Robin

Mayo Clinic

Antimicrobial Agents and Chemotherapy | May 27, 2015 | Volume: 59 | Issue: 8 | Pages: 4610-4615

10.1128/aac.00483-15 | PMID 26014944 Get It

ABSTRACT Bacterial biofilms are difficult to treat using available antimicrobial agents, so new antibiofilm strategies are needed. We previously showed that 20, 200, and 2,000 μA of electrical current reduced bacterial biofilms of Staphylococcus aureus , Staphylococcus epidermidis , and Pseudomonas aeruginosa . Here, we tested continuous direct current at lower amperages, intermittent direct current, and combinations of surface materials (Teflon or titanium) and electrode compositions (stainless steel, graphite, titanium, or platinum) against S. aureus , S. epidermidis , and P. aeruginosa biofilms. In addition, we tested 200 or 2,000 μA for 1 and 4 days against biofilms of 33 strains representing 13 species of microorganisms. The logarithmic reduction factor was used to measure treatment effects. Using continuous current delivery, the lowest active amperage was 2 μA for 1, 4, or 7 days against P. aeruginosa and 5 μA for 7 days against S. epidermidis and S. aureus biofilms. Delivery of 200 μA for 4 h a day over 4 days reduced P. aeruginosa , S. aureus , and S. epidermidis biofilms on Teflon or titanium discs. A reduction of P. aeruginosa , S. aureus , and S. epidermidis biofilms was measured for 23 of 24 combinations of surface materials and electrode compositions tested. Four days of direct current delivery reduced biofilms of 25 of 33 strains studied. In conclusion, low-amperage current or 4 h a day of intermittent current delivered using a variety of electrode compositions reduced P. aeruginosa , S. aureus , and S. epidermidis biofilms on a variety of surface materials. The electricidal effect was observed against a majority of bacterial species studied.
Causes and Implications of the Disappearance of Rifampin Resistance in a Rat Model of Methicillin-Resistant Staphylococcus aureus Foreign Body Osteomyelitis
Brinkman, Cassandra L., Tyner, Harmony L. , Schmidt-Malan, Suzannah M., Mandrekar, Jayawant N. , Patel, Robin , Patel, Robin

Mayo Clinic

Antimicrobial Agents and Chemotherapy | May 19, 2015 | Volume: 59 | Issue: 8 | Pages: 4481-4488

10.1128/aac.05078-14 | PMID 25987614 Get It

ABSTRACT Orthopedic foreign body-associated infections are often treated with rifampin-based combination antimicrobial therapy. We previously observed that rifampin-resistant and methicillin-resistant Staphylococcus aureus (MRSA) isolates were present 2 days after cessation of rifampin therapy in experimental foreign body osteomyelitis. Unexpectedly, only rifampin-susceptible isolates were detected 14 days after the completion of treatment. We studied two rifampin-resistant isolates recovered 2 days after treatment and one rifampin-susceptible isolate recovered 14 days after treatment. Growing these isolates alone in vitro or in vivo demonstrated no fitness defects; however, in mixed culture, rifampin-susceptible bacteria outcompeted rifampin-resistant bacteria. In vivo , two courses of rifampin treatment (25 mg/kg of body weight every 12 h for 21 days) yielded a greater decrease in bacterial quantity in the bones of treated animals 14 days following treatment than that in animals receiving a single course of treatment ( P = 0.0398). In infections established with equal numbers of rifampin-resistant and rifampin-susceptible bacteria, one course of rifampin treatment did not affect bacterial quantities. Rifampin-resistant and rifampin-susceptible isolates were recovered both 2 days and 14 days following treatment completion; however, the proportion of animals with rifampin-resistant isolates was lower at 14 days than that at 2 days following treatment completion ( P = 0.024). In untreated animals infected with equal numbers of rifampin-resistant and rifampin-susceptible bacteria for 4 weeks, rifampin-susceptible isolates were exclusively recovered, indicating the outcompetition of rifampin-resistant by rifampin-susceptible isolates. The data presented imply that although there is no apparent fitness defect in rifampin-resistant bacteria when grown alone, they are outcompeted by rifampin-susceptible bacteria when the two are present together. The findings also suggest that selected rifampin resistance may not persist in initially rifampin-susceptible infections following the discontinuation of rifampin.
Long-Term Outcome of Pyogenic Vertebral Osteomyelitis: A Cohort Study of 260 Patients
Kowalski, Todd J., Osmon, Douglas R. , Enzler, Mark J., Steckelberg, James M., Huddleston, P.M. , Mandrekar, Jayawant, Berbari, Elie F. , Mandrekar, Jayawant M, Gupta, Arjun , Nassr, Ahmad , Huddleston, Paul M

Mayo Clinic

Open Forum Infectious Diseases | December 6, 2014 | Volume: 1 | Issue: 3 | Pages: No page available

10.1093/ofid/ofu107 | PMID 25734175 Get It

AbstractBackground. The long-term outcome of patients with pyogenic vertebral osteomyelitis (PVO) has not been fully assessed.Methods. We conducted a retrospective cohort study to describe the long-term outcome of PVO and to assess risk factors for treatment failure in patients evaluated at our institution between 1994 and 2002. Patients were observed until July 1, 2013.Results. Two hundred sixty patients with PVO were included in this study. Twenty-seven percent (70) of patients developed their infection after an invasive spinal procedure. Staphylococcus aureus accounted for 40% (103) of infections. Forty-nine percent (128) of patients underwent spinal surgery as part of their initial therapy. The median duration of parenteral antimicrobial therapy was 42 days (interquartile range, 38–53). The estimated 2-, 5-, and 10-year cumulative probability of treatment failure-free survival was 72%, 69%, and 69%, respectively. Seventy-five percent of patients who developed treatment failure did so within 4.7 months of diagnosis. Residual neurological defects and persistent back pain were seen in 16% and 32% of patients, respectively. In a multivariate analysis, longer duration of symptoms before diagnosis and having an infection with S. aureus were associated with increased risk of treatment failure.Conclusions. Increasing duration of symptoms and infection with S. aureus were associated with treatment failure in patients with PVO. Most treatment failures occurred early after initiation of treatment. Pyogenic vertebral osteomyelitis is associated with a high 2-year failure rate. Persistent neurological deficits and back pain are common after therapy.
Prevention of Staphylococcus Epidermidis Biofilm Formation Using Electrical Current
Pozo, José Luís del , Rouse, Mark S., Euba, Gorane , Greenwood‐Quaintance, Kerryl E. , Mandrekar, Jayawant N. , Steckelberg, James M., Patel, Robin , Del Pozo, Jose L, Patel, Robin

Mayo Clinic

Journal of Applied Biomaterials & Functional Materials | September 5, 2014 | Volume: 12 | Issue: 2 | Pages: 81-83

10.5301/jabfm.5000208 | PMID 25097026 Get It

A technique for the prevention of staphylococcal adhesion by electrical current exposure was investigated. Teflon coupons were exposed to a continuous flow of 10 3 cfu/ml Staphylococcus epidermidis with or without 2000 microA DC electrical current delivered by electrodes on opposite sides of a coupon, touching neither each other nor the coupon. A mean 3.46 (SD, 0.20) and 5.70 (SD, 1.03) log 10 cfu/cm 2 were adhered to the non-electrical current exposed coupons after 4 h and 24 h, respectively. A mean 2.46 (SD, 0.31) and 1.47 (SD, 0.73) log 10 cfu/cm 2 were adhered after 4 h and 24 h with exposure to 2000 microA electrical current delivered by graphite electrodes. A mean 2.21 (SD, 0.14) and 0.55 (SD, 0.00) log 10 cfu/cm 2 were adhered after 4 h and 24 h with exposure to 2000 microA electrical current delivered by stainless steel electrodes. Electrical current may be useful in the prevention of staphylococcal adhesion to biomaterials.