Citations

Clear

93 citation(s) found for "Liu, Wei".

Mixed integer programming with dose‐volume constraints in intensity‐modulated proton therapy
Zhang, Pengfei , Fan, Neng , Shan, Jie , Bues, Martin , Schild, Steven E. , Liu, Wei , Bues, Martin

Mayo Clinic

Journal of Applied Clinical Medical Physics | July 6, 2017 | Volume: 18 | Issue: 5 | Pages: 29-35

10.1002/acm2.12130 | PMID 28681976 Get It

AbstractBackgroundIn treatment planning for intensity‐modulated proton therapy (IMPT), we aim to deliver the prescribed dose to the target yet minimize the dose to adjacent healthy tissue. Mixed‐integer programming (MIP) has been applied in radiation therapy to generate treatment plans. However, MIP has not been used effectively for IMPT treatment planning with dose‐volume constraints. In this study, we incorporated dose‐volume constraints in an MIP model to generate treatment plans for IMPT.MethodsWe created a new MIP model for IMPT with dose volume constraints. Two groups of IMPT treatment plans were generated for each of three patients by using MIP models for a total of six plans: one plan was derived with the Limited‐memory Broyden–Fletcher–Goldfarb–Shanno (L‐BFGS) method while the other plan was derived with our MIP model with dose‐volume constraints. We then compared these two plans by dose‐volume histogram (DVH) indices to evaluate the performance of the new MIP model with dose‐volume constraints. In addition, we developed a model to more efficiently find the best balance between tumor coverage and normal tissue protection.ResultsThe MIP model with dose‐volume constraints generates IMPT treatment plans with comparable target dose coverage, target dose homogeneity, and the maximum dose to organs at risk (OARs) compared to treatment plans from the conventional quadratic programming method without any tedious trial‐and‐error process. Some notable reduction in the mean doses of OARs is observed.ConclusionsThe treatment plans from our MIP model with dose‐volume constraints can meet all dose‐volume constraints for OARs and targets without any tedious trial‐and‐error process. This model has the potential to automatically generate IMPT plans with consistent plan quality among different treatment planners and across institutions and better protection for important parallel OARs in an effective way.
A novel and fast method for proton range verification using a step wedge and 2D scintillator
Shen, Jiajian , Allred, Bryce C., Robertson, Daniel , Remmes, Nicholas B. , Keole, Sameer R., Bues, Martin , Robertson, Daniel G, Liu, Wei , Sio, Terence T. , Shen, Jiajian , Bues, Martin

Mayo Clinic

Medical Physics | June 30, 2017 | Volume: 44 | Issue: 9 | Pages: 4409-4414

10.1002/mp.12439 | PMID 28665529 Get It

PurposeTo implement and evaluate a novel and fast method for proton range verification by using a planar scintillator and step wedge.MethodsA homogenous proton pencil beam plan with 35 energies was designed and delivered to a 2D flat scintillator with a step wedge. The measurement was repeated 15 times (3 different days, 5 times per day). The scintillator image was smoothed, the Bragg peak and distal fall off regions were fitted by an analytical equation, and the proton range was calculated using simple trigonometry. The accuracy of this method was verified by comparing the measured ranges to those obtained using an ionization chamber and a scanning water tank, the gold standard. The reproducibility was evaluated by comparing the ranges over 15 repeated measurements. The sensitivity was evaluated by delivering to same beam to the system with a film inserted under the wedge.ResultsThe range accuracy of all 35 proton energies measured over 3 days was within 0.2 mm. The reproducibility in 15 repeated measurements for all 35 proton ranges was ±0.045 mm. The sensitivity to range variation is 0.1 mm for the worst case. This efficient procedure permits measurement of 35 proton ranges in less than 3 min. The automated data processing produces results immediately. The setup of this system took less than 5 min. The time saving by this new method is about two orders of magnitude when compared with the time for water tank range measurements.ConclusionsA novel method using a scintillator with a step wedge to measure the proton range was implemented and evaluated. This novel method is fast and sensitive, and the proton range measured by this method was accurate and highly reproducible.
Ileocecal vascularized lymph node transfer for the treatment of extremity lymphedema: A case report
Ciudad, Pedro , Manrique, Oscar J. , Agko, Mouchammed , Liu, En‐Wei , Chang, Wei‐Ling , Yeo, Matthew Sze‐Wei , Huang, Tony Chieh‐Ting , Chilgar, Ram M., Chen, Hung‐Chi , Chen, Hung‐Chi , Mouchammed, Agko , Huang, Tony C T

Mayo Clinic

Microsurgery | May 25, 2017 | Volume: 39 | Issue: 1 | Pages: 81-84

10.1002/micr.30186 | PMID 28543381 Get It

Vascularized lymph node (VLN) transfer has been of high interest in the past decade for the treatment of lymphedema, since it has been shown to be effective in reducing limb volumes, decreasing infectious episodes and improving quality of life. Multiple donor sites have been described in the quest for the optimal one. Herein, we describe a novel lymph node flap option based on the ileocolic artery and vein. The ileocecal vascularized lymph node (IC‐VLN) flap was used in the management of a 33‐year‐old male patient with lower extremity lymphedema secondary to left inguinal trauma. The patient had previously underwent a pedicled omentum flap transposition with minimal improvement in limb size and persistent episodes of infection. At 15 month follow‐up, the IC‐VLN flap improved the lymphatic drainage in the affected limb with a mean limb circumference reduction rate of 26.3%. No donor site complications or further episodes of infection were noted. According to our findings, the IC‐VLN flap may be another option for VLN transfer in very selected cases. Nevertheless, larger series with a longer follow‐up are required to analyze the efficacy and long‐term results of this flap.
Exploratory study of the association of volumetric modulated arc therapy (VMAT) plan robustness with local failure in head and neck cancer
Patel, Samir H. , Harrington, Daniel P. , Hu, Yanle , Ding, Xiaoning, Shen, Jiajian , Halyard, Michele Y. , Wong, William W. , Ezzell, Gary E., Bues, Martin , Schild, Steven E. , Liu, Wei , Shen, Jiajian , Bues, Martin

Mayo Clinic

Journal of Applied Clinical Medical Physics | May 15, 2017 | Volume: 18 | Issue: 4 | Pages: 76-83

10.1002/acm2.12099 | PMID 28503916 Get It

AbstractThis work is to show which is more relevant to cause local failures (LFs) due to patient setup uncertainty between the planning target volume (PTV) underdosage and the potential target underdosage subject to patient setup uncertainties in head and neck (H&N) cancer treated with volumetric‐modulated arc therapy (VMAT). Thirteen LFs in 10 H&N patients treated by VMAT were analyzed. Measures have been taken to minimize the chances of insufficient target delineation for these patients and the patients were clinically determined to have LF based on the PET/CT scan results by an experienced radiologist and then reviewed by a second experienced radiation oncologist. Two methods were used to identify the possible locations of LF due to underdosage: (a) examining the standard VMAT plan, in which the underdosed volume in the nominal dose distribution (UVN) was generated by subtracting the volumes receiving the prescription doses from PTVs, and (b) plan robustness analysis, in which in addition to the nominal dose distribution, six perturbed dose distributions were created by translating the CT iso‐center in three cardinal directions by the PTV margin. The coldest dose distribution was represented by the minimum of the seven doses in each voxel. The underdosed volume in the coldest dose distribution (UVC) was generated by subtracting the volumes receiving the prescription doses in the coldest dose distribution from the volumes receiving the prescription doses in the nominal dose distribution. UVN and UVC were subsequently examined for spatial association with the locations of LF. The association was tested using the binominal distribution and the Fisher's exact test of independence. We found that of 13 LFs, 11 were associated with UVCs (P = 0.011), while three were associated with UVNs (P = 0.99). We concluded that the possible target underdosage due to patient setup uncertainties appeared to be a more relevant factor associated with LF in VMAT for H&N cancer than the compromised PTV coverage at least for the patients included in this study.
Comparison of linear and nonlinear programming approaches for “worst case dose” and “minmax” robust optimization of intensity‐modulated proton therapy dose distributions
Zaghian, Maryam, Cao, Wenhua , Liu, Wei , Kardar, Laleh, Randeniya, S, Mohan, Radhe , Lim, Gino J. , Liu, Wei

Mayo Clinic

Journal of Applied Clinical Medical Physics | March 14, 2017 | Volume: 18 | Issue: 2 | Pages: 15-25

10.1002/acm2.12033 | PMID 28300378 Get It

AbstractRobust optimization of intensity‐modulated proton therapy (IMPT) takes uncertainties into account during spot weight optimization and leads to dose distributions that are resilient to uncertainties. Previous studies demonstrated benefits of linear programming (LP) for IMPT in terms of delivery efficiency by considerably reducing the number of spots required for the same quality of plans. However, a reduction in the number of spots may lead to loss of robustness. The purpose of this study was to evaluate and compare the performance in terms of plan quality and robustness of two robust optimization approaches using LP and nonlinear programming (NLP) models. The so‐called “worst case dose” and “minmax” robust optimization approaches and conventional planning target volume (PTV)‐based optimization approach were applied to designing IMPT plans for five patients: two with prostate cancer, one with skull‐based cancer, and two with head and neck cancer. For each approach, both LP and NLP models were used. Thus, for each case, six sets of IMPT plans were generated and assessed: LP‐PTV‐based, NLP‐PTV‐based, LP‐worst case dose, NLP‐worst case dose, LP‐minmax, and NLP‐minmax. The four robust optimization methods behaved differently from patient to patient, and no method emerged as superior to the others in terms of nominal plan quality and robustness against uncertainties. The plans generated using LP‐based robust optimization were more robust regarding patient setup and range uncertainties than were those generated using NLP‐based robust optimization for the prostate cancer patients. However, the robustness of plans generated using NLP‐based methods was superior for the skull‐based and head and neck cancer patients. Overall, LP‐based methods were suitable for the less challenging cancer cases in which all uncertainty scenarios were able to satisfy tight dose constraints, while NLP performed better in more difficult cases in which most uncertainty scenarios were hard to meet tight dose limits. For robust optimization, the worst case dose approach was less sensitive to uncertainties than was the minmax approach for the prostate and skull‐based cancer patients, whereas the minmax approach was superior for the head and neck cancer patients. The robustness of the IMPT plans was remarkably better after robust optimization than after PTV‐based optimization, and the NLP‐PTV‐based optimization outperformed the LP‐PTV‐based optimization regarding robustness of clinical target volume coverage. In addition, plans generated using LP‐based methods had notably fewer scanning spots than did those generated using NLP‐based methods.
Perturbation of water‐equivalent thickness as a surrogate for respiratory motion in proton therapy
Matney, J, Park, Peter C., Court, Laurence E. , Zhu, X. Ron, Dong, Lei , Li, Heng , Liu, Wei , Mohan, Radhe

Mayo Clinic

Journal of Applied Clinical Medical Physics | February 28, 2017 | Volume: 17 | Issue: 2 | Pages: 368-378

10.1120/jacmp.v17i2.5795 | PMID 27074459 Get It

Respiratory motion is traditionally assessed using tumor motion magnitude. In proton therapy, respiratory motion causes density variations along the beam path that result in uncertainties of proton range. This work has investigated the use of water‐equivalent thickness (WET) to quantitatively assess the effects of respiratory motion on calculated dose in passively scattered proton therapy (PSPT). A cohort of 29 locally advanced non‐small cell lung cancer patients treated with 87 PSPT treatment fields were selected for analysis. The variation in WET (ΔWET) along each field was calculated between exhale and inhale phases of the simulation four‐dimensional computed tomography. The change in calculated dose (ΔDose) between full‐inhale and full‐exhale phase was quantified for each field using dose differences, 3D gamma analysis, and differential area under the curve (ΔAUC) analysis. Pearson correlation coefficients were calculated between ΔDose and ΔWET. Three PSPT plans were redesigned using field angles to minimize variations in ΔWET and compared to the original plans. The median ΔWET over 87 treatment fields ranged from 1‐9 mm, while the ΔWET 95th percentile value ranged up to 42 mm. The ΔWET was significantly correlated to the ΔDose for all metrics analyzed. The patient plans that were redesigned using ΔWET analysis to select field angles were more robust to the effects of respiratory motion, as ΔAUC values were reduced by more than 60% in all three cases. The tumor motion magnitude alone does not capture the potential dosimetric error due to respiratory motion because the proton range is sensitive to the motion of all patient anatomy. The use of ΔWET has been demonstrated to identify situations where respiratory motion can impact the calculated dose. Angular analysis of ΔWET may be capable of designing radiotherapy plans that are more robust to the effects of respiratory motion.PACS number(s): 87.55.‐x
Evaluation of the systematic error in using 3D dose calculation in scanning beam proton therapy for lung cancer
Liu, Wei , Matney, J, Zhang, Xiaodong , Li, Yupeng , Zhu, Ronald X., Li, Heng , Park, Peter, Liao, Zhongxing , Chang, Joe Y. , Li, Yupeng, Liu, Wei

Mayo Clinic

Journal of Applied Clinical Medical Physics | February 27, 2017 | Volume: 15 | Issue: 5 | Pages: 47-56

10.1120/jacmp.v15i5.4810 | PMID 25207565 Get It

The objective of this study was to evaluate and understand the systematic error between the planned three‐dimensional (3D) dose and the delivered dose to patient in scanning beam proton therapy for lung tumors. Single‐field and multifield optimized scanning beam proton therapy plans were generated for ten patients with stage II‐III lung cancer with a mix of tumor motion and size. 3D doses in CT datasets for different respiratory phases and the time‐weighted average CT, as well as the four‐dimensional (4D) doses were computed for both plans. The 3D and 4D dose differences for the targets and different organs at risk were compared using dose‐volume histogram (DVH) and voxel‐based techniques, and correlated with the extent of tumor motion. The gross tumor volume (GTV) dose was maintained in all 3D and 4D doses, using the internal GTV override technique. The DVH and voxel‐based techniques are highly correlated. The mean dose error and the standard deviation of dose error for all target volumes were both less than 1.5% for all but one patient. However, the point dose difference between the 3D and 4D doses was up to 6% for the GTV and greater than 10% for the clinical and planning target volumes. Changes in the 4D and 3D doses were not correlated with tumor motion. The planning technique (single‐field or multifield optimized) did not affect the observed systematic error. In conclusion, the dose error in 3D dose calculation varies from patient to patient and does not correlate with lung tumor motion. Therefore, patient‐specific evaluation of the 4D dose is important for scanning beam proton therapy for lung tumors.PACS number: 87.55.D
Robust treatment planning with conditional value at risk chance constraints in intensity‐modulated proton therapy
An, Yu , Liang, Jianming , Bues, Martin , Liu, Wei , Schild, Steven E. , Liu, Wei , Bues, Martin

Mayo Clinic

Medical Physics | January 3, 2017 | Volume: 44 | Issue: 1 | Pages: 28-36

10.1002/mp.12001 | PMID 28044325 Get It

Background and purposeIntensity‐modulated proton therapy (IMPT) is highly sensitive to range uncertainties and uncertainties caused by setup variation. The conventional inverse treatment planning of IMPT based on the planning target volume (PTV) is not often sufficient to ensure robustness of treatment plans. We applied a probabilistic framework (chance‐constrained optimization) in IMPT planning to hedge against the influence of uncertainties.Material and methodsWe retrospectively selected one patient with lung cancer, one patient with head and neck (H&N) cancer, and one with prostate cancer for this analysis. Using their original images and prescriptions, we created new IMPT plans using two methods: (1) a robust chance‐constrained treatment planning method with the clinical target volume (CTV) as the target; (2) the margin‐based method with PTV as the target, which was solved by commercial software, CPLEX, using linear programming. For the first method, we reformulated the model into a tractable mixed‐integer programming problem and sped up the calculation using Benders decomposition. The dose‐volume histograms (DVHs) from the nominal and perturbed dose distributions were used to assess and compare plan quality. DVHs for all uncertain scenarios along with the nominal DVH were plotted. The width of the “bands” of DVHs was used to quantify the plan sensitivity to uncertainty. The newly developed Benders decomposition method was compared with a commercial solution to demonstrate its computational efficiency. The trade‐off between nominal plan quality and plan robustness was investigated.ResultsOur chance‐constrained model outperformed the PTV method in terms of tumor coverage, tumor dose homogeneity, and plan robustness. Our model was shown to produce IMPT plans to meet the dose‐volume constraints of organs at risk (OARs) and had better sparing of OARs than the PTV method in the three clinical cases included in this study. The chance‐constrained model provided a flexible tool for users to balance between plan robustness and plan quality. In addition, our in‐house developed method was found to be much faster than the commercial solution.ConclusionWith explicit control of plan robustness, the chance‐constrained robust optimization model generated superior IMPT plans compared to the PTV‐based method.
Late outcomes of adult survivors of childhood non‐Hodgkin lymphoma: A report from the St. Jude Lifetime Cohort Study
Ehrhardt, Matthew J. , Sandlund, John T., Zhang, Nan , Liu, Wei , Ness, Kirsten K. , Bhakta, Nickhill , Chemaitilly, Wassim , Krull, Kevin R. , Brinkman, Tara M. , Crom, Deborah B., Kun, Larry E. , Kaste, Sue C. , Armstrong, Gregory T. , Srivastava, Kumar , Mulrooney, Daniel A. , Green, Daniel M. , Robison, Leslie L. , Hudson, Melissa M. , Mulrooney, Daniel A , Ness, Kirsten K , Bhakta, Nickhill

Mayo Clinic

Pediatric Blood & Cancer | November 16, 2016 | Volume: 64 | Issue: 6 | Pages: No page available

10.1002/pbc.26338 | PMID 27860222 Get It

AbstractBackgroundSurvivors of childhood non‐Hodgkin lymphoma (NHL) are at increased risk for chronic health conditions. The objective of this study was to characterize health conditions, neurocognitive function, and physical performance among a clinically evaluated cohort of 200 childhood NHL survivors.MethodChronic health and neurocognitive conditions were graded as per a modified version of the National Cancer Institute Common Terminology Criteria for Adverse Events (CTCAE) and impaired physical function defined as performance < 10th percentile of normative data. Multivariable regression was used to investigate associations between sociodemographic characteristics, therapeutic exposures, and outcomes.ResultsSurvivors were a median age of 10 years (range 1–19) at diagnosis and 34 years (range 20–58) at evaluation. Eighty‐eight (44%) received radiation, 46 (23%) cranial radiation, and 69 (35%) high‐dose methotrexate. Most prevalent CTCAE Grades 3–4 (severe life‐threatening) conditions were obesity (35%), hypertension (9%), and impairment of executive function (13%), attention (9%), and memory (4%). Many had impaired strength (48%), flexibility (39%), muscular endurance (36%), and mobility (36%). Demographic and treatment‐related factors were associated with the development of individual chronic diseases and functional deficits.ConclusionsClinical evaluation identified a high prevalence of chronic health conditions, neurocognitive deficits, and performance limitations in childhood NHL survivors.
Surgical Therapies and Tissue Engineering: At the Intersection Between Innovation and Regulation
Rubin, J. Peter, Gurtner, Geoffrey C. , March, Keith L. , Seppänen‐Kaijansinkko, Riitta , Yaszemski, Michael J. , Yoo, James J. , Liu, Wei Xin

Mayo Clinic

Tissue Engineering Part A | February 19, 2016 | Volume: 22 | Issue: 5-6 | Pages: 397-400

10.1089/ten.tea.2016.0002 | PMID 26895615 Get It