Citations

Clear

142 citation(s) found for "Hsieh, TC".

Individualized and generalized models for predicting observer performance on liver metastasis detection using CT
Pillai, Parvathy Sudhir , Holmes, David R. , Carter, Rickey E. , Cook, David A. , Karwoski, R., Fidler, Jeff L. , Yu, Lifeng , Hsieh, Scott S. , Carter, Rickey E , Inoue, Akitoshi , Karwoski, Ron, Leng, Shuai , Yu, Lifeng , McCollough, Cynthia H , Hsieh, Scott S , Inoue, Akitoshi , Fidler, Jeff L. , Fletcher, Joel G. , Leng, Shuai , McCollough, Cynthia H.

Mayo Clinic

Journal of Medical Imaging | September 13, 2022 | Volume: 9 | Issue: 05 | Pages: No page available

10.1117/1.jmi.9.5.055501 | PMID 36120413 Get It

Estimating the accuracy of dual energy chest radiography for coronary calcium detection with lateral or anteroposterior orientations
Hsieh, Scott S. , Budoff, Matthew J.

Mayo Clinic

Medical Physics | July 18, 2022 | Volume: 49 | Issue: 9 | Pages: 5763-5772

10.1002/mp.15855 | PMID 35848231 Get It

AbstractPurposeCoronary artery calcium (CAC) scoring with CT has been studied as a risk stratification tool for cardiovascular disease. However, concerns remain from the radiation dose, economic expense, and incidental findings associated with this exam. Dual energy chest X‐ray (DE CXR) has been proposed as an alternative, but validation of this technique remains limited. The purpose of this work was twofold: first, to estimate the sensitivity and specificity of DE CXR using simulation of patient datasets in a CAC screening cohort; second, to assess if sensitivity and specificity could be improved using a lateral instead of an anteroposterior (AP) orientation.MethodsWe started from a cohort of 73 CAC scoring CT exams after exclusions for metal wires, data truncation, or with age outside 40–75 years. The fraction of CT CAC scores in the validation set of 0, 1–99, 100–299, and 300+ were 36, 25, 14, and 26%, respectively. CT datasets were decomposed on a voxel‐by‐voxel basis into mixtures of water and calcium according to CT number. DE CXR images were simulated using polyenergetic forward projection with scatter estimated from Monte Carlo. We assumed a technique of 60 and 120 kVp for the dual energy acquisition. The tube current was scaled such that the estimated radiation dose from DE CXR was 10 times less than CAC scoring CT. Patient motion was not simulated. Two readers read the validation set in a blinded, randomized fashion, and estimated the amount of CAC in each DE CXR image using a semiquantitative 4‐point scale. Although patients present on a spectrum of CAC severity, in the primary analysis, sensitivity and specificity were calculated by dichotomizing patients into two categories of CT CAC (Agatston) scores of either 0–99 or 100+.ResultsFrom the lateral orientation, average sensitivity between two readers was 69% (range, 69–69%), specificity was 85% (range, 84–86%), and area under the curve (AUC) was 0.81 (range, 0.80–0.81). From the AP orientation, average sensitivity was 35% (range, 31–38%), average specificity was 70% (range, 66–73%), and AUC was 0.54 (range, 0.53–0.55). Reader DE CXR scores agreed within 1 point of the 4‐point scale on 97% of ratings from the lateral orientation and 80% from the AP orientation. From the lateral orientation, AUC increased when considering higher CT CAC score thresholds as disease positive; for thresholds of 1+, 300+, and 1000+, average AUC was 0.72, 0.81, and 0.92, respectively. From the AP orientation, AUC was 0.57, 0.55, and 0.61, respectively.ConclusionsDE CXR for CAC scoring may have higher diagnostic accuracy when acquired from the lateral orientation. The sensitivity and specificity of lateral DE CXR, when combined with its modest cost and radiation dose, suggest a possible role for this technique in screening coronary calcium in lower risk individuals. These estimates of diagnostic accuracy are derived from simulation of patient datasets and have not been corroborated with experimental or clinical images.
A minimum SNR criterion for computed tomography object detection in the projection domain
Hsieh, Scott S. , Yu, Lifeng , Huber, Nathan R. , Leng, Shuai , Yu, Lifeng , McCollough, Cynthia H.

Mayo Clinic

Medical Physics | June 27, 2022 | Volume: 49 | Issue: 8 | Pages: 4988-4998

10.1002/mp.15832 | PMID 35754205 Get It

Abstract Background A common rule of thumb for object detection is the Rose criterion, which states that a signal must be five standard deviations above background to be detectable to a human observer. The validity of the Rose criterion in CT imaging is limited due to the presence of correlated noise. Recent reconstruction and denoising methodologies are also able to restore apparent image quality in very noisy conditions, and the ultimate limits of these methodologies are not yet known. Purpose To establish a lower bound on the minimum achievable signal‐to‐noise ratio (SNR) for object detection, below which detection performance is poor regardless of reconstruction or denoising methodology. Methods We consider a numerical observer that operates on projection data and has perfect knowledge of the background and the objects to be detected, and determine the minimum projection SNR that is necessary to achieve predetermined lesion‐level sensitivity and case‐level specificity targets. We define a set of discrete signal objects that encompasses any lesion of interest and could include lesions of different sizes, shapes, and locations. The task is to determine which object of is present, or to state the null hypothesis that no object is present. We constrain each object in to have equivalent projection SNR and use Monte Carlo methods to calculate the required projection SNR necessary. Because our calculations are performed in projection space, they impose an upper limit on the performance possible from reconstructed images. We chose to be a collection of elliptical or circular low contrast metastases and simulated detection of these objects in a parallel beam system with Gaussian statistics. Unless otherwise stated, we assume a target of 80% lesion‐level sensitivity and 80% case‐level specificity and a search field of view that is 6 cm by 6 cm by 10 slices. Results When contains only a single object, our problem is equivalent to two‐alternative forced choice (2AFC) and the required projection SNR is 1.7. When consists of circular 6‐mm lesions at different locations in space, the required projection SNR is 5.1. When is extended to include ellipses and circles of different sizes, the required projection SNR increases to 5.3. The required SNR increases if the sensitivity target, specificity target, or search field of view increases. Conclusions Even with perfect knowledge of the background and target objects, the ideal observer still requires an SNR of approximately 5. This is a lower bound on the SNR that would be required in real conditions, where the background and target objects are not known perfectly. Algorithms that denoise lesions with less than 5 projection SNR, regardless of the denoising methodology, are expected to show vanishing effects or false positive lesions.
ATR-mediated CD47 and PD-L1 up-regulation restricts radiotherapy-induced immune priming and abscopal responses in colorectal cancer
Hsieh, Cheng‐En , Krishnan, Sunil , Wu, Ren‐Chin , Boda, Akash R. , Liu, Arthur , Winkler, Michelle , Hsu, Wen‐Hao , Lin, Steven H. , Hung, Mien‐Chie , Bhanu, Krithikaa Rajkumar , Srinivasamani, Anupallavi, Azevedo, Ricardo , Chou, Yung‐Chih , DePinho, Ronald A. , Gubin, Matthew M. , Slay, Ravaen, Hegde, Shweta , Hartley, Genevieve , Lea, Spencer T. , Prasad, Rishika , Morrow, Brittany, Couillault, Coline , Steiner, Madeline , Wang, Chun‐Chieh, Venkatesulu, Bhanu Prasad , Curran, Michael A. , Hsieh, Rodney Cheng-En , Lin, Steven H , Chan, Li-Chuan , De Azevedo, Ricardo Alexandre , Chou, Yung-Chih , DePinho, Ronald A , Gubin, Matthew , Vilar, Eduardo , Chen, Chao Hsien , Jayaprakash, Priyamvada , Lea, Spencer T , Prasad, Rishika , Couillault, Coline Agnes , Wang, Chun-Chieh , Taniguchi, Cullen , Kim, Betty Y S , Chen, Junjie , Rudqvist, Nils-Petter , Curran, Michael A , Krishnan, Sunil , Liu, Arthur J , Kim, Betty Y.S. , Chen, Junjie

Mayo Clinic

Science Immunology | June 10, 2022 | Volume: 7 | Issue: 72 | Pages: No page available

10.1126/sciimmunol.abl9330 | PMID 35687697 Get It

Radiotherapy (RT) of colorectal cancer (CRC) can prime adaptive immunity against tumor-associated antigen (TAA)–expressing CRC cells systemically. However, abscopal tumor remissions are extremely rare, and the postirradiation immune escape mechanisms in CRC remain elusive. Here, we found that irradiated CRC cells used ATR-mediated DNA repair signaling pathway to up-regulate both CD47 and PD-L1, which through engagement of SIRPα and PD-1, respectively, prevented phagocytosis by antigen-presenting cells and thereby limited TAA cross-presentation and innate immune activation. This postirradiation CD47 and PD-L1 up-regulation was observed across various human solid tumor cells. Concordantly, rectal cancer patients with poor responses to neoadjuvant RT exhibited significantly elevated postirradiation CD47 levels. The combination of RT, anti-SIRPα, and anti–PD-1 reversed adaptive immune resistance and drove efficient TAA cross-presentation, resulting in robust TAA-specific CD8 T cell priming, functional activation of T effectors, and increased T cell clonality and clonal diversity. We observed significantly higher complete response rates to RT/anti-SIRPα/anti–PD-1 in both irradiated and abscopal tumors and prolonged survival in three distinct murine CRC models, including a cecal orthotopic model. The efficacy of triple combination therapy was STING dependent as knockout animals lost most benefit of adding anti-SIRPα and anti–PD-1 to RT. Despite activation across the myeloid stroma, the enhanced dendritic cell function accounts for most improvements in CD8 T cell priming. These data suggest ATR-mediated CD47 and PD-L1 up-regulation as a key mechanism restraining radiation-induced immune priming. RT combined with SIRPα and PD-1 blockade promotes robust antitumor immune priming, leading to systemic tumor regressions.
A survey of colonoscopists with and without in‐depth knowledge of water‐aided colonoscopy
Leung, Felix W. , Koo, Malcolm , Yen, Andrew W. , Siau, Keith , Hsieh, Yu‐Hsi , Ishaq, Sauid , Cheng, Chi‐Liang , Ramirez, Francisco C. , Bak, Adrian, Karnes, William E. , Bayupurnama, Putut , Leung, Joseph W., Groen, Piet C. de , Hsieh, Yu-Hsi , Ishaq, Sauid , Cheng, Chi-Liang , Bayupurnama, Putut , Cadoni, Sergio

Mayo Clinic

Journal of Gastroenterology and Hepatology | May 26, 2022 | Volume: 37 | Issue: 9 | Pages: 1785-1791

10.1111/jgh.15896 | PMID 35613903 Get It

AbstractBackground and AimEndoscopy featured water‐aided colonoscopy (WAC) as novel in the Innovation Forum in 2011. Gastrointestinal Endoscopy published a modified Delphi consensus review (MDCR) that supports WAC for clinical practice in 2021. We tested the hypothesis that experience was an important predictor of WAC use, either as water immersion (WI), water exchange (WE), or a combination of WI and WE.MethodsA questionnaire was sent by email to the MDCR authors with an in‐depth knowledge of WAC. They responded and also invited colleagues and trainees without in‐depth knowledge to respond. Logistic regression analysis was used with the reasons for WAC use treated as the primary outcome. Reports related to WAC post MDCR were identified.ResultsOf 100 respondents, > 80% indicated willingness to adopt and modify practice to accommodate WAC. Higher adenoma detection rate (ADR) incentivized WE use. Procedure time slots ≤ 30 and > 30 min significantly predicted WI and WE use, respectively. Co‐authors of the MDCR were significantly more likely to perform WAC (odds ratio [OR] = 7.5, P = 0.037). Unfamiliarity with (OR = 0.11, P = 0.02) and absence of good experience (OR = 0.019, P = 0.002) were associated with colonoscopists less likely to perform WAC. Reports related to WAC post MDCR revealed overall and right colon WE outcomes continued to improve. Network meta‐analyses showed that WE was superior to Cap and Endocuff. On‐demand sedation with WE shortened nursing recovery time.ConclusionsAn important predictor of WAC use was experience. Superior outcomes continued to be reported with WE.
Correction to: Accelerated versus watchful waiting strategy of kidney replacement therapy for acute kidney injury: a systematic review and meta-analysis of randomized clinical trials
Chen, Jui‐Yi , Pan, Heng‐Chih , Hsieh, Chih-Chieh , Hsu, Tsuen‐Wei , Huang, Yun‐Ting , Huang, Tao‐Min , Huang, Chun-Te , Chen, Yung‐Ming , Shiao, Chih‐Chung , Kashani, Kianoush , Wu, Vin‐Cent

Mayo Clinic

Clinical Kidney Journal | March 29, 2022 | Volume: 15 | Issue: 5 | Pages: 1027-1027

10.1093/ckj/sfac059 | PMID 35503545 Get It

A simulated comparison of lung tumor target verification using stereoscopic tomosynthesis or radiography
Hsieh, Scott S. , Ng, Lydia W., Lee, Percy , Cao, Minsong

Mayo Clinic

Medical Physics | March 23, 2022 | Volume: 49 | Issue: 5 | Pages: 3041-3052

10.1002/mp.15634 | PMID 35319790 Get It

AbstractPurposeMobile lung tumors are increasingly being treated with ablative radiotherapy, for which precise motion management is essential. In‐room stereoscopic radiography systems are able to guide ablative radiotherapy for stationary cranial lesions but not optimally for lung tumors unless fiducial markers are inserted. We propose augmenting stereoscopic radiographic systems with multiple small x‐ray sources to provide the capability of imaging with stereoscopic, single frame tomosynthesis.MethodsIn single frame tomosynthesis, nine x‐ray sources are placed in a 3 × 3 configuration and energized simultaneously. The beams from these sources are collimated so that they converge on the tumor and then diverge to illuminate nine non‐overlapping sectors on the detector. These nine sector images are averaged together and filtered to create the tomosynthesis effect. Single frame tomosynthesis is intended to be an alternative imaging mode for existing stereoscopic systems with a field of view that is three times smaller and a temporal resolution equal to the frame rate of the detector. We simulated stereoscopic tomosynthesis and radiography using Monte Carlo techniques on 60 patients with early‐stage lung cancer from the NSCLC‐Radiomics dataset. Two board‐certified radiation oncologists reviewed these simulated images and rated them on a 4‐point scale (1: tumor not visible; 2: tumor visible but inadequate for motion management; 3: tumor visible and adequate for motion management; 4: tumor visibility excellent). Each tumor was independently presented four times (two viewing angles from radiography and two viewing angles from tomosynthesis) in a blinded fashion over two reading sessions.ResultsThe fraction of tumors that were rated as adequate or excellent for motion management (scores 3 or 4) from at least one viewing angle was 53% using radiography and 90% using tomosynthesis. From both viewing angles, the corresponding fractions were 7% for radiography and 48% for tomosynthesis. Readers agreed exactly on 62% of images and within 1 point on 98% of images. The acquisition technique was estimated to be 75 mAs at 120 kVp per treatment fraction assuming one verification image per breath, approximately one order of magnitude less than a standard dose cone beam CT.Conclusions Stereoscopic tomosynthesis may provide a noninvasive, low dose, intrafraction motion verification technique for lung tumors treated by ablative radiotherapy. The system architecture is compatible with real‐time video capture at 30 frames per second. Simulations suggest that most, but not all, lung tumors can be adequately visualized from at least one viewing angle.
Accelerated versus watchful waiting strategy of kidney replacement therapy for acute kidney injury: a systematic review and meta-analysis of randomized clinical trials
Chen, Jui‐Yi , Pan, Heng‐Chih , Hsieh, Chih-Chieh , Hsu, Tsuen‐Wei , Huang, Yun‐Ting , Huang, Tao‐Min , Huang, Chun-Te , Kashani, Kianoush , Kashani, Kianoush B , Chen, Yung‐Ming , Shiao, Chih‐Chung , Wu, Vin‐Cent

Mayo Clinic

Clinical Kidney Journal | January 12, 2022 | Volume: 15 | Issue: 5 | Pages: 974-984

10.1093/ckj/sfac011 | PMID 35498901 Get It

ABSTRACT Background Critically ill patients with severe acute kidney injury (AKI) requiring kidney replacement therapy (KRT) have a grim prognosis. Recently, multiple studies focused on the impact of KRT initiation time [i.e., accelerated versus watchful waiting KRT initiation (WWS-KRT)] on patient outcomes. We aim to review the results of all related clinical trials. Methods In this systematic review, we searched all relevant randomized clinical trials from January 2000 to April 2021. We assessed the impacts of accelerated versus WWS-KRT on KRT dependence, KRT-free days, mortality and adverse events, including hypotension, infection, arrhythmia and bleeding. We rated the certainty of evidence according to Cochrane methods and the GRADE approach. Results A total of 4932 critically ill patients with AKI from 10 randomized clinical trials were included in this analysis. The overall 28-day mortality rate was 38.5%. The 28-day KRT-dependence rate was 13.0%. The overall incident of KRT in the accelerated group was 97.4% and 62.8% in the WWS-KRT group. KRT in the accelerated group started 36.7 h earlier than the WWS-KRT group. The two groups had similar risks of 28-day [pooled log odds ratio (OR) 1.001, P = 0.982] and 90-day (OR 0.999, P = 0.991) mortality rates. The accelerated group had a significantly higher risk of 90-day KRT dependence (OR 1.589, P = 0.007), hypotension (OR 1.687, P < 0.001) and infection (OR 1.38, P = 0.04) compared with the WWS-KRT group. Conclusions This meta-analysis revealed that accelerated KRT leads to a higher probability of 90-day KRT dependence and dialysis-related complications without any impact on mortality rate when compared with WWS-KRT. Therefore, we suggest the WWS-KRT strategy for critically ill patients.
SARS–CoV‐2 Infection and COVID‐19 Outcomes in Rheumatic Diseases: A Systematic Literature Review and Meta‐Analysis
Conway, Richard , Grimshaw, Alyssa , Konig, Maximilian F. , Putman, Michael , Duarte‐García, Alí , Tseng, Leslie Yingzhijie , Cabrera, Diego M. , Chock, Yu Pei Eugenia, Degirmenci, Huseyin Berk , Duff, Eimear , Egeli, Buğra Han , Gupta, Akash , Hoyer, Bimba F. , Jayatilleke, Arundathi , Jin, Shangyi , Kasia, Christopher , Khilnani, Aneka , Kilian, Adam , Kim, Alfred H.J. , Lin, Chung Mun Alice , Low, Candice , Sparks, Jeffrey A. , Tam, Herman , Ugarte‐Gil, Manuel F. , Ung, Natasha, Wang, Kaicheng , Wise, Leanna , Yang, Ziyi , Young, Kristen , Grainger, Rebecca , Wallace, Zachary S. , Hsieh, Evelyn , Alliance, the COVID‐19 Global Rheumatology, Grimshaw, Alyssa A , Graef, Elizabeth R , Hoyer, Bimba F , Jayatilleke, Arundathi , Kilian, Adam , Kim, Alfred H J , Lin, Chung Mun Alice , Proulx, Laurie , Sattui, Sebastian E , Singh, Namrata , Sparks, Jeffrey A , Ugarte-Gil, Manuel F , Wang, Kaicheng , Wise, Leanna M , Young, Kristen J , Liew, Jean , Grainger, Rebecca , Wallace, Zachary S , Hsieh, Evelyn , Duarte-García, Alí , Conway, Richard , Graef, Elizabeth R. , Harkins, Patricia , Sattui, Sebastian E. , Liew, Jean W. , Alliance, the COVID‐19 Global Rheumatology

Mayo Clinic

Arthritis & Rheumatology | November 22, 2021 | Volume: 74 | Issue: 5 | Pages: 766-775

10.1002/art.42030 | PMID 34807517 Get It

ObjectiveThe relative risk of SARS–CoV‐2 infection and COVID‐19 disease severity among people with rheumatic and musculoskeletal diseases (RMDs) compared to those without RMDs is unclear. This study was undertaken to quantify the risk of SARS–CoV‐2 infection in those with RMDs and describe clinical outcomes of COVID‐19 in these patients.MethodsWe conducted a systematic literature review using 14 databases from January 1, 2019 to February 13, 2021. We included observational studies and experimental trials in RMD patients that described comparative rates of SARS–CoV‐2 infection, hospitalization, oxygen supplementation/intensive care unit (ICU) admission/mechanical ventilation, or death attributed to COVID‐19. Methodologic quality was evaluated using the Joanna Briggs Institute critical appraisal tools or the Newcastle‐Ottawa scale. Risk ratios (RRs) and odds ratios (ORs) with 95% confidence intervals (95% CIs) were calculated, as applicable for each outcome, using the Mantel‐Haenszel formula with random effects models.ResultsOf the 5,799 abstracts screened, 100 studies met the criteria for inclusion in the systematic review, and 54 of 100 had a low risk of bias. Among the studies included in the meta‐analyses, we identified an increased prevalence of SARS–CoV‐2 infection in patients with an RMD (RR 1.53 [95% CI 1.16–2.01]) compared to the general population. The odds of hospitalization, ICU admission, and mechanical ventilation were similar in patients with and those without an RMD, whereas the mortality rate was increased in patients with RMDs (OR 1.74 [95% CI 1.08–2.80]). In a smaller number of studies, the adjusted risk of outcomes related to COVID‐19 was assessed, and the results varied; some studies demonstrated an increased risk while other studies showed no difference in risk in patients with an RMD compared to those without an RMD.ConclusionPatients with RMDs have higher rates of SARS–CoV‐2 infection and an increased mortality rate.