Citations

Clear

151 citation(s) found for "Beltran, H".

A methodology to abridge microdosimetric distributions without a significant loss of the spectral information needed for the RBE computation in carbon ion therapy
Parisi, Alessio , Beltran, Chris , Furutani, Keith M. , Beltran, Chris J , Parisi, Alessio , Furutani, Keith M

Mayo Clinic

Journal of Applied Clinical Medical Physics | May 25, 2023 | Volume: 24 | Issue: 7 | Pages: No page available

10.1002/acm2.14049 | PMID 37227694 Get It

Abstract Background In order to compute the relative biological effectiveness (RBE) of ion radiation therapy with the Mayo Clinic Florida microdosimetric kinetic model (MCF MKM), it is necessary to process entire microdosimetric distributions. Therefore, a posteriori RBE recalculations (i.e., for a different cell line or another biological endpoint) would require whole spectral information. It is currently not practical to compute and store all this data for each clinical voxel. Purpose To develop a methodology that allows to store a limited amount of physical information without losing accuracy in the RBE calculations nor the possibility of a posteriori RBE recalculations. Methods Computer simulations for four monoenergetic 12 C ion beams and a 12 C ion spread‐out Bragg peak (SOBP) were performed to assess lineal energy distributions as a function of the depth within a water phantom. These distributions were used in combination with the MCF MKM to compute the in vitro clonogenic survival RBE for human salivary gland tumor cells (HSG cell line) and human skin fibroblasts (NB1RGB cell line). The RBE values were also calculated with a new abridged microdosimetric distribution methodology (AMDM) and compared with the reference RBE calculations using the entire distributions. Results The maximum relative deviation between the RBE values computed using the entire distributions and the AMDM was 0.61% (monoenergetic beams) and 0.49% (SOBP) for the HSG cell line, while 0.45% (monoenergetic beams) and 0.26% (SOBP) for the NB1RGB cell line. Conclusion The excellent agreement between the RBE values computed using the entire lineal energy distributions and the AMDM represents a milestone for the clinical implementation of the MCF MKM.
Technical note: Delivery benefit and dosimetric implication of synchrotron‐based proton pencil beam scanning using continuous scanning mode
Beltran, Chris , Liu, Chunbo , Shen, Jiajian , Shen, Jiajian , Beltran, Chris J , Liang, Xiaoying , Li, Heng , Furutani, Keith M.

Mayo Clinic

Medical Physics | April 28, 2023 | Volume: 50 | Issue: 8 | Pages: 5252-5261

10.1002/mp.16434 | PMID 37115647 Get It

AbstractBackgroundDiscrete spot scanning (DSS) is the commonly used method for proton pencil beam scanning (PBS). There is lack of data on the dose‐driven continuous scanning (DDCS).PurposeTo investigate delivery benefits and dosimetric implications of DDCS versus DSS for PBS systems.MethodsThe irradiation duty factor, beam delivery time (BDT), and dose deviation were simulated for eight treatment plans in prostate, head and neck, liver, and lung, with both conventional fractionation and hypofractionation schemes. DDCS results were compared with those of DSS.ResultsThe DDCS irradiation duty factor (range, 11%–41%) was appreciably improved compared to DSS delivery (range, 4%–14%), within which, hypofractionation schemes had greater improvement than conventional fractionation. With decreasing stop ratio constraints, the DDCS BDT reduction was greater, but dose deviation also increased. With stop ratio constraints of 2, 1, 0.5, and 0, DDCS BDT reduction reached to 6%, 10%, 12%, and 15%, respectively, and dose deviation reached to 0.6%, 1.7%, 3.0%, and 5.2% root mean square error in PTV DVH, respectively. The 3%/2‐mm gamma passing rate was greater than 99% with stop ratio constraints of 2 and 1, and greater than 95% with a stop ratio of 0.5. When the stop ratio constraint was removed, five of the eight treatment plans had a 3%/2‐mm gamma passing rate greater than 95%, and the other three plans had a 3%/2‐mm gamma passing rate between 90% and 95%.ConclusionsThe irradiation duty factor was considerably improved with DDCS. Smaller stop ratio constraints led to shorter BDTs, but with the cost of larger dose deviations. Our finding suggested that a stop ratio of 1 constraint seems to yield acceptable DDCS dose deviation.
Randomized Phase III Study of Enzalutamide Compared With Enzalutamide Plus Abiraterone for Metastatic Castration-Resistant Prostate Cancer (Alliance A031201 Trial)
Morris, Michael J. , Hillman, David W. , Bobek, Olivia , Ryan, Charles J. , Antonarakis, Emmanuel S. , Bryce, Alan H. , Hahn, Olwen, Beltran, Himisha , Armstrong, Andrew J. , Schwartz, Lawrence B. , Langevin, Brooke , McGary, Eric C., Mehan, Paul, Goldkorn, Amir , Roth, Bruce J. , Xiao, Han , Watt, Colleen, Taplin, Mary‐Ellen , Halabi, Susan , Antonarakis, Emmanuel S. , Hillman, David W , Bobek, Olivia , Antonarakis, Emmanuel S , Bryce, Alan H , Beltran, Himisha , Armstrong, Andrew J , Beumer, Jan Hendrik , Goldkorn, Amir , Roth, Bruce J , Xiao, Han , Halabi, Susan , Small, Eric J , Morris, Michael J , Antonarakis, Emmanuel S , Heller, Glenn , Lewis, Lionel D. , Small, Eric J.

Mayo Clinic

Journal of Clinical Oncology | March 30, 2023 | Volume: 41 | Issue: 18 | Pages: 3352-3362

10.1200/jco.22.02394 | PMID 36996380 Get It

PURPOSE Enzalutamide and abiraterone both target androgen receptor signaling but via different mechanisms. The mechanism of action of one drug may counteract the resistance pathways of the other. We sought to determine whether the addition of abiraterone acetate and prednisone (AAP) to enzalutamide prolongs overall survival (OS) in patients with metastatic castration-resistant prostate cancer (mCRPC) in the first-line setting. PATIENTS AND METHODS Men with untreated mCRPC were randomly assigned (1:1) to receive first-line enzalutamide with or without AAP. The primary end point was OS. Toxicity, prostate-specific antigen declines, pharmacokinetics, and radiographic progression-free survival (rPFS) were also examined. Data were analyzed using an intent-to-treat approach. The Kaplan-Meier estimate and the stratified log-rank statistic were used to compare OS between treatments. RESULTS In total, 1,311 patients were randomly assigned: 657 to enzalutamide and 654 to enzalutamide plus AAP. OS was not statistically different between the two arms (median, 32.7 [95% CI, 30.5 to 35.4] months for enzalutamide v 34.2 [95% CI, 31.4 to 37.3] months for enzalutamide and AAP; hazard ratio [HR], 0.89; one-sided P = .03; boundary nominal significance level = .02). rPFS was longer in the combination arm (median rPFS, 21.3 [95% CI, 19.4 to 22.9] months for enzalutamide v 24.3 [95% CI, 22.3 to 26.7] months for enzalutamide and AAP; HR, 0.86; two-sided P = .02). However, pharmacokinetic clearance of abiraterone was 2.2- to 2.9-fold higher when administered with enzalutamide, compared with clearance values for abiraterone alone. CONCLUSION The addition of AAP to enzalutamide for first-line treatment of mCRPC was not associated with a statistically significant benefit in OS. Drug-drug interactions between the two agents resulting in increased abiraterone clearance may partly account for this result, although these interactions did not prevent the combination regimen from having more nonhematologic toxicity.
Pragmatic, Prospective Comparative Effectiveness Trial of Carbon Ion Therapy, Surgery, and Proton Therapy for the Management of Pelvic Sarcomas (Soft Tissue/Bone) Involving the Bone: The PROSPER Study Rationale and Design
Petersen, Ivy A. , Imai, Reiko , Hug, Eugen B., Fiore, Maria Rosaria , Fossati, Piero , Yamada, Shigeru , Orlandi, Ester , Zhang, Qing, Bao, Cihang , Seidensaal, Katharina , May, Byron C. , Harrell, Anna , Houdek, Matthew T. , Vallow, Laura A., Rose, Peter S. , Haddock, Michael G. , Ashman, Jonathan B. , Goulding, Krista , Attia, Steven , Krishnan, Sunil , Mahajan, Anita , Foote, Robert L. , Keole, Sameer R., Beltran, Chris , Welch, Eric M., Wilke, Benjamin K. , Imai, Reiko , Yamada, Shigeru , Zhang, Qing , May, Byron C , Harrell, Anna C , Houdek, Matthew T , Goulding, Krista A., Krishnan, Sunil , Foote, Robert , Karim, Mohammed, Ahmed, Safia K. , Beltran, Chris J , Hoppe, Bradford S. , DeWees, T.A. , Debus, Jürgen , Laack, Nadia N. , Karim, Mohammed

Mayo Clinic

Cancers | March 8, 2023 | Volume: 15 | Issue: 6 | Pages: 1660

10.3390/cancers15061660 | PMID 36980545 Get It

Surgical treatment of pelvic sarcoma involving the bone is the standard of care but is associated with several sequelae and reduced functional quality of life (QOL). Treatment with photon and proton radiotherapy is associated with relapse. Carbon ion radiotherapy (CIRT) may reduce both relapse rates and treatment sequelae. The PROSPER study is a tricontinental, nonrandomized, prospective, three-arm, pragmatic trial evaluating treatments of pelvic sarcoma involving the bone. Patients aged at least 15 years are eligible for inclusion. Participants must have an Eastern Cooperative Oncology Group Performance Status score of two or less, newly diagnosed disease, and histopathologic confirmation of pelvic chordoma, chondrosarcoma, osteosarcoma, Ewing sarcoma with bone involvement, rhabdomyosarcoma (RMS) with bone involvement, or non-RMS soft tissue sarcoma with bone involvement. Treatment arms include (1) CIRT (n = 30) delivered in Europe and Asia, (2) surgical treatment with or without adjuvant radiotherapy (n = 30), and (3) proton therapy (n = 30). Arms two and three will be conducted at Mayo Clinic campuses in Arizona, Florida, and Minnesota. The primary end point is to compare the 1-year change in functional QOL between CIRT and surgical treatment. Additional comparisons among the three arms will be made between treatment sequelae, local control, and other QOL measures.
Technical note: Progressive deep learning: An accelerated training strategy for medical image segmentation
ByongSu, Choi, Olberg, Sven, Park, Justin C., Kim, Jin Sung , Shrestha, Deepak K. , Yaddanapudi, Sridhar , Beltran, Chris , Yaddanapudi, Shridhar, Beltran, Chris J , Yaddanapudi, Sridhar , Choi, Byongsu, Furutani, Keith M.

Mayo Clinic

Medical Physics | February 10, 2023 | Volume: 50 | Issue: 8 | Pages: 5075-5087

10.1002/mp.16267 | PMID 36763566 Get It

AbstractBackgroundRecent advancements in Deep Learning (DL) methodologies have led to state‐of‐the‐art performance in a wide range of applications especially in object recognition, classification, and segmentation of medical images. However, training modern DL models requires a large amount of computation and long training times due to the complex nature of network structures and the large number of training datasets involved. Moreover, it is an intensive, repetitive manual process to select the optimized configuration of hyperparameters for a given DL network.PurposeIn this study, we present a novel approach to accelerate the training time of DL models via the progressive feeding of training datasets based on similarity measures for medical image segmentation. We term this approach Progressive Deep Learning (PDL).MethodsThe two‐stage PDL approach was tested on the auto‐segmentation task for two imaging modalities: CT and MRI. The training datasets were ranked according to similarity measures between each sample based on Mean Square Error (MSE), Peak Signal‐to‐Noise Ratio (PSNR), Structural Similarity Index (SSIM), and the Universal Quality Image Index (UQI) values. At the start of the training process, a relatively coarse sampling of training datasets with higher ranks was used to optimize the hyperparameters of the DL network. Following this, the samples with higher ranks were used in step 1 to yield accelerated loss minimization in early training epochs and the total dataset was added in step 2 for the remainder of training.ResultsOur results demonstrate that the PDL approach can reduce the training time by nearly half (∼49%) and can predict segmentations (CT U‐net/DenseNet dice coefficient: 0.9506/0.9508, MR U‐net/DenseNet dice coefficient: 0.9508/0.9510) without major statistical difference (Wilcoxon signed‐rank test) compared to the conventional DL approach. The total training times with a fixed cutoff at 0.95 DSC for the CT dataset using DenseNet and U‐Net architectures, respectively, were 17 h, 20 min and 4 h, 45 min in the conventional case compared to 8 h, 45 min and 2 h, 20 min with PDL. For the MRI dataset, the total training times using the same architectures were 2 h, 54 min and 52 min in the conventional case and 1 h, 14 min and 25 min with PDL.ConclusionThe proposed PDL training approach offers the ability to substantially reduce the training time for medical image segmentation while maintaining the performance achieved in the conventional case.
A Geant4 shielding design for the first US carbon multi-ion hybrid synchrotron facility
Dougherty, Jingjing M. , Furutani, Keith M. , Guatelli, Susanna , Liang, Xiaoying , Rosenfeld, Anatoly , Beltran, Chris , Furutani, Keith M , Guatelli, S , Liang, Xiaoying , Rosenfeld, A B , Beltran, Chris J , Dougherty, Jingjing M , Bolst, David

Mayo Clinic

Physics in Medicine & Biology | February 2, 2023 | Volume: 68 | Issue: 5 | Pages: 054002

10.1088/1361-6560/acb887 | PMID 36731141 Get It

Abstract The Mayo Clinic Florida Integrated Oncology Building will be the home of the first spot-scanning only carbon/proton hybrid therapy system by Hitachi, Ltd. It will provide proton beams up to kinetic energies of 230 MeV and carbon beams up to 430 MeV n −1 for clinical deployment. To provide adequate radiation protection, the Geant4 (v10.6) Monte Carlo toolkit was utilized to quantify the ambient dose equivalent at a 10 mm depth ( H *(10)) for photons and neutrons. To perform accurate calculations of the ambient dose equivalent, three-dimensional computer-aided design files of the entire planned facility were imported into Geant4, as well as certain particle system components such as the bending magnets, fast Faraday cup, and gantry. Particle fluence was scored using 60 cm diameter spheres, which were strategically placed throughout areas of interests. Analytical calculations were performed as first-pass design checks. Major shielding slabs were optimized using Geant4 simulations iteratively, with more than 20 alternative designs evaluated within Geant4. The 430 MeV n −1 carbon beams played the most significant role in concrete thickness Requirements. The primary wall thickness for the carbon fixed beam room is 4 meters. The presence of the proton gantry structure in the simulation caused the ambient dose equivalent to increase by around 67% at the maze entrance, but a decrease in the high energy beam transport corridor. All shielding primary and secondary goals for clinical operations were met per state regulation and national guidelines.
Sudden Cardiac Arrest in Basketball and Soccer Stadiums, the Role of Automated External Defibrillators: A Review. For the BELTRAN Study (BaskEtbaLl and soccer sTadiums: Registry on Automatic exterNal defibrillators)
Bassi, Mario D. , Farina, Juan M. , Bombau, Jorge, Maurice, Marío Fitz , Bortman, Guillermo , Núñez, Elaine , Márquez, Manlio F. , Bornancini, Norberto , Baranchuk, Adrián , defibrillators), BELTRAN Study (BaskEtbaLl and soccer sTadiums: Registry on Automatic exterNal, Baranchuk, Adrian , Farina, Juan M , defibrillators), BELTRAN Study (BaskEtbaLl and soccer sTadiums: Registry on Automatic exterNal

Mayo Clinic

Arrhythmia & Electrophysiology Review | January 31, 2023 | Volume: 12 | Issue: No issue available | Pages: No page available

10.15420/aer.2022.30 | PMID 36845166 Get It

Sudden cardiac arrest (SCA) during sports events has a dramatic impact on stadium-goers and the public and is often associated with poor outcomes unless treated with an automated external defibrillator (AED). Despite this, stadiums vary in AED use. This review aims to identify the risks and incidences of SCA, and the use of AEDs in soccer and basketball stadiums. A narrative review of all relevant papers was conducted. Athletes across all sports face an SCA risk of 1:50,000 athlete-years, with the greatest risk of SCA in young male athletes (1:35,000 person-years) and black male athletes (1:18,000 person-years). Africa and South America have the poorest soccer SCA outcomes at 3% and 4% survival. AED use on-site improves survival greater than defibrillation by emergency services. Many stadiums do not have AEDs implemented into medical plans and the AEDs are often unrecognisable or are obstructed. Therefore, AEDs should be used on-site, use clear signalling, have certified trained personnel, and be incorporated into stadiums’ medical plans.
Clonogenic Survival RBE Calculations in Carbon Ion Therapy: The Importance of the Absolute Values of α and β in the Photon Dose-Response Curve and a Strategy to Mitigate Their Anticorrelation
Parisi, Alessio , Furutani, Keith M. , Parisi, Alessio , Furutani, Keith M , Beltran, Chris

Mayo Clinic

Quantum Beam Science | January 30, 2023 | Volume: 7 | Issue: 1 | Pages: 3

10.3390/qubs7010003 Get It

The computation of the relative biological effectiveness (RBE) is a fundamental step in the planning of cancer radiotherapy treatments with accelerated ions. Numerical parameters derived analyzing the dose response of the chosen cell line after irradiation to photons (i.e., α and β, namely the linear and quadratic terms of the linear-quadratic model of cell survival) are generally used as input to biophysical models to predict the ion RBE. The α/β ratio for the photon exposure is generally regarded as an indicator of cell radiosensitivity. However, previous studies suggest that α/β might not be a sufficient parameter to model the RBE of relatively high linear energy transfer (LET) radiation such as carbon ions. For a fixed α/β, the effect of the absolute values of α and β on the computed RBE is underexplored. Furthermore, since α and β are anticorrelated during the fit of the photon-exposed in vitro survival data, different linear-quadratic fits could produce different sets of α and β, thus affecting the RBE calculations. This article reports the combined effect of the α/β ratio and the absolute values α and β on the RBE computed with the Mayo Clinic Florida microdosimetric kinetic model (MCF MKM) for 12C ions of different LET. Furthermore, we introduce a theory-based strategy to potentially mitigate the anticorrelation between α and β during the fit of the photon dose-response biological data.
The Mayo Clinic Florida Microdosimetric Kinetic Model of Clonogenic Survival: Application to Various Repair-Competent Rodent and Human Cell Lines
Parisi, Alessio , Beltran, Chris , Furutani, Keith M. , Beltran, Chris J , Parisi, Alessio , Furutani, Keith M

Mayo Clinic

International Journal of Molecular Sciences | October 19, 2022 | Volume: 23 | Issue: 20 | Pages: 12491

10.3390/ijms232012491 | PMID 36293348 Get It

The relative biological effectiveness (RBE) calculations used during the planning of ion therapy treatments are generally based on the microdosimetric kinetic model (MKM) and the local effect model (LEM). The Mayo Clinic Florida MKM (MCF MKM) was recently developed to overcome the limitations of previous MKMs in reproducing the biological data and to eliminate the need for ion-exposed in vitro data as input for the model calculations. Since we are considering to implement the MCF MKM in clinic, this article presents (a) an extensive benchmark of the MCF MKM predictions against corresponding in vitro clonogenic survival data for 4 rodent and 10 cell lines exposed to ions from 1H to 238U, and (b) a systematic comparison with published results of the latest version of the LEM (LEM IV). Additionally, we introduce a novel approach to derive an approximate value of the MCF MKM model parameters by knowing only the animal species and the mean number of chromosomes. The overall good agreement between MCF MKM predictions and in vitro data suggests the MCF MKM can be reliably used for the RBE calculations. In most cases, a reasonable agreement was found between the MCF MKM and the LEM IV.
Investigation of beam delivery time for synchrotron-based proton pencil beam scanning system with novel scanning mode
Liang, Xiaoying , Liu, Chunbo , Shen, Jiajian , Bues, Martin , Dougherty, Jingjing M. , Parisi, Alessio , Shrestha, Deepak K. , Yaddanpudi, Sridhar, Beltran, Chris , Yaddanapudi, Sridhar , Furutani, Keith M. , Shen, Jiajian , Bues, Martin , Dougherty, Jingjing M , Parisi, Alessio , Beltran, Chris J , Liang, Xiaoying , Yaddanapudi, Sridhar , Li, Heng

Mayo Clinic

Physics in Medicine & Biology | July 25, 2022 | Volume: 67 | Issue: 17 | Pages: 175001

10.1088/1361-6560/ac8410 | PMID 35878611 Get It

Abstract Objective. To investigate synchrotron-based proton pencil beam scanning (PBS) beam delivery time (BDT) using novel continuous scanning mode. Approach. A BDT calculation model was developed for the Hitachi particle therapy system. The model was validated against the measured BDT of 36 representative clinical proton PBS plans with discrete spot scanning (DSS) in the current Hitachi proton therapy system. BDTs were calculated with the next generation using Mayo Clinic Florida system operating parameters for conventional DSS, and novel dose driven continuous scanning (DDCS). BDTs of DDCS with and without Break Spots were investigated. Main results. For DDCS without Break Spots, the use of Stop Ratio to control the transit dose largely reduced the beam intensity and consequently, severely prolonged the BDT. DDCS with Break Spots was able to maintain a sufficiently high beam intensity while controlling transit dose. In DDCS with Break Spots, tradeoffs were made between beam intensity and number of Break Spots. Therefore, BDT decreased with increased beam intensity but reached a plateau for beam intensity larger than 10 MU s −1 . Averaging over all clinical plans, BDT was reduced by 10% for DDCS with Break Spots compared to DSS. Significance. DDCS with Break Spots reduced BDT. DDCS has the potential to further reduce BDT under the ideal scenario which requests both stable beam intensity extraction and accurately modelling the transit dose. Further investigation is warranted.