Citations

Clear

152 citation(s) found for "An, Kai‐Nan".

Kinematics of the Normal Arch of the Foot and Ankle Under Physiologic Loading
Kitaoka, Harold B. , Lundberg, Arne, Luo, Zong Ping, An, Kai‐Nan , Luo, Zong Ping

Mayo Clinic

Foot & Ankle International | March 3, 2013 | Volume: 16 | Issue: 8 | Pages: 492-499

10.1177/107110079501600806 | PMID 8520662 Get It

We studied 15 cadaver feet to determine three-dimensional motion of selected tarsal bones under axial loading at three different loading levels. We determined the motion of individual joints and also the rotation of the tarsal bones in relation to the tibia. Joint rotations increased consistently with higher loads. The navicular-talar joint had the greatest total screw axis rotation, which averaged 9.4° ± 2.2° at 667 N of load, followed by the first metatarsal-navicular (mean, 7.2° ± 1.5°), talar-tibial (mean, 5.2° ± 1.6°), and calcaneal-talar (mean, 4.4° ± 1.7°) joints. The observed changes indicate the need for assessment of foot and ankle alignment clinically and radiologically while the patient is weightbearing.
Material Properties of the Plantar Aponeurosis
Kitaoka, Harold B. , Luo, Zong Ping, Growney, Eríc S., Berglund, Lawrence J., An, Kai‐Nan, Luo, Zong Ping

Mayo Clinic

Foot & Ankle International | March 3, 2013 | Volume: 15 | Issue: 10 | Pages: 557-560

10.1177/107110079401501007 | PMID 7834064 Get It

Material properties of the plantar aponeurosis were determined by a two-dimensional video tracking method to simultaneously measure the aponeurosis deformation. Failure loads averaged 1189 ± 244 N and were higher in men. Average stiffness of the intact fascia was 203.7 ± 50.5 N/mm at a loading rate of 11.12 N/sec and it did not vary significantly for the loading rates of 11.12 to 1112 N/sec. The high tensile loads required for failure were consistent with clinical and biomechanical studies and indicated the importance of the aponeurosis in foot function and arch stability.
Biomechanical Evaluation of Longitudinal Arch Stability
Huang, Ching-Kuei, Kitaoka, Harold B. , An, Kai‐Nan , Chao, Edmund Y.S., Huang, Ching-Kuei

Mayo Clinic

Foot & Ankle | March 3, 2013 | Volume: 14 | Issue: 6 | Pages: 353-357

10.1177/107110079301400609 | PMID 8406252 Get It

In spite of the common occurrence of pes planus and multiple operations that have been reported to relieve the associated symptoms, there is little published on the relative contribution of various structures to stabilization of the arch of the foot. Twelve fresh-frozen human cadaveric feet were loaded along the tibial axis with compressive loads of 230, 460, and 690 newtons with the specimens intact and after sequential sectioning of plantar fascia, plantar ligaments, and spring ligament. Structures were sectioned in six different sequences and changes in vertical and horizontal dimensions of the medial arch were measured. The highest relative contribution to arch stability was provided by the plantar fascia, followed by plantar ligaments and spring ligament. Plantar fascia was a major factor in maintenance of the medial longitudinal arch. Its division in the cadaveric feet decreased arch stiffness by 25%.
Evaluation of Fracture Resistance in Aqueous Environment of Four Restorative Systems for Posterior Applications. Part 1
Dhima, Matilda, Assad, Daniel, Volz, John E., An, Kai‐Nan, Berglund, Lawrence J., Carr, Alan B. , Salinas, Thomas

Mayo Clinic

Journal of Prosthodontics | December 22, 2012 | Volume: 22 | Issue: 4 | Pages: 256-260

10.1111/j.1532-849x.2012.00948.x | PMID 23279080 Get It

AbstractPurposeThe goals of this study were to: (1) establish a range of the performance of four restorative systems for posterior single‐tooth crowns under single load to fracture submerged in an aqueous environment, (2) identify restorative system(s) of interest to be examined in the second study phase under sliding contact step‐stress fatigue as full‐contour anatomically appropriate single posterior tooth restoration(s), (3) establish a range for loading/testing for phase 2.Materials and MethodsForty specimens (n = 10/group) of 2 mm uniform thickness were tested. Group 1: monolithic lithium disilicate IPS e.max Press; group 2: IPS e.max ZirPress, 0.8 mm zirconia core with 1.2 mm pressed veneering porcelain; group 3: IPS e.max ZirPress, 0.4 mm zirconia core with 1.6 mm pressed veneering porcelain; group 4: IPS InLine PoM. Specimens were bonded to a block of polycast acrylic resin on a 30° sloped surface with resin cement. Specimens were axially single loaded to failure while submerged under water.ResultsThere was a statistically significant difference (p < 0.001) in failure load among the four restorative systems. Lithium disilicate showed a mean failure load similar to mean maximum posterior bite forces (743.1 ± 114.3 N). IPS e.max Zirpress with a 0.4 mm zirconia core exhibited the lowest mean failure load (371.4 ± 123.0 N).ConclusionFracture resistance of monolithic lithium disilicate in an aqueous environment is promising and requires second phase testing to evaluate the potential of various thicknesses appropriate for posterior single tooth applications. Doubling the IPS e.max Zirpress zirconia core from 0.4 mm to 0.8 mm increased the fracture resistance of this restorative system threefold.
Cell Migration after Synovium Graft Interposition at Tendon Repair Site
Hayashi, Masanori , Zhao, Chunfeng , An, Kai‐Nan , Amadio, Peter C.

Mayo Clinic

HAND | October 22, 2012 | Volume: 7 | Issue: 4 | Pages: 374-379

10.1007/s11552-012-9453-x | PMID 24294156 Get It

Background We have recently reported that interpositional synovium grafts from tendon sheath have a potential to accelerate tendon healing when implanted at the repair site. The purpose of this study was to investigate the effect of orientation of the synovium after synovium graft transplantation, by comparing the ability of cells from the visceral and parietal surfaces to migrate into the tendon in a canine tissue culture model. Methods The synovium graft was placed within a complete tendon laceration, with either the visceral or parietal surface facing the proximal end of the lacerated tendon. The number of migrating cells was quantified by a cell migration assay. Qualitative immunohistochemistry and confocal laser microscopy were also used at day 10. Results Many labeled synovial cells were observed within the tendon to which the visceral surface of the synovium graft was facing. Migrated cells were also observed on the parietal side, but there were fewer cells compared to visceral surface cells. Migrating cells all expressed α-smooth muscle actin. Conclusion We found that graft orientation affected cell migration. Whether this finding has clinical significance awaits in vivo study.
Comparison of step-cut and Pulvertaft attachment for flexor tendon graft: a biomechanics evaluation in an in vitro canine model
Hashimoto, Takahiro , Thoreson, Andrew R. , An, Kai‐Nan , Amadio, Peter C. , Zhao, Chunfeng

Mayo Clinic

Journal of Hand Surgery (European Volume) | April 4, 2012 | Volume: 37 | Issue: 9 | Pages: 848-854

10.1177/1753193412442460 | PMID 22490997 Get It

The purpose of this study was to compare two different methods of joining tendons of similar and dissimilar sizes between recipient and donor tendons for flexor tendon grafts. Flexor digitorum profundus (FDP) and peroneus longus (PL) canine tendons were harvested and divided into four groups. The repair technique we compared was a step-cut (SC) suture and a Pulvertaft weave (PW). FDP tendons were significantly larger in diameter than PL tendons ( p < 0.05). The volume of the SC repairs using either FDP or PL tendon as a graft was significantly smaller than PW repairs ( p < 0.05). The ultimate load to failure and repair stiffness in FDP graft tendons significantly increased compared with the PL graft tendons ( p < 0.05). The SC suture can be used as an alternative to the PW, with similar strength and less bulk for repairs using graft tendons of similar diameter. Surgeons should be aware of the effect of graft tendon size and repair method on strength and bulk when performing flexor tendon grafts.
CHONDROCYTE RESPONSE TO TENSILE AND COMPRESSIVE CYCLIC LOADING MODALITIES
Kamineni, Srinath , Wani, Zubair , Luo, Zong-Ping , An, Kai‐Nan , Yoshida, Ruriko

Mayo Clinic

Journal of Musculoskeletal Research | March 23, 2012 | Volume: 15 | Issue: 01 | Pages: 1250006

10.1142/s0218957712500066 Get It

There is very little data addressing cartilage response to tensile forces, and no literature attempts to correlate compressive with tensile modalities. Our hypothesis was that the cyclic compression and tension modulate chondrocyte matrix proteoglycan synthetic response differently. Porcine chondrocytes cultured to confluence on a flexible membrane were subjected to cyclic compression (Group A: 13 KPa at 1 Hz) or tension (Group C: 10% strain at 1 Hz) for 16 or 32 h; while controls not subjected to any force were kept (Group B). The chondrocytes were then stained with alcian blue and stained areas quantified with confocal microscopy and image processing software. Two-factor ANOVA with post-hoc tests (Scheffe and Bonferroni) statistical analysis were used. Proteoglycan staining covered 46% (range 28%–61%) and 39% (range 26%–49%) of the surface area following 32 and 16 h of compression respectively, 23% (range 15%–49%) for control, and 19% (range 10%–29%) and 16% (range 9%–25%) following 16 and 32 h tension respectively. Proteoglycan content following all compressions was significantly greater than with cyclic tension or control (p < 0.0001). Our data demonstrate that chondrocytes cultured in vitro respond to compression distinctly different from tension and that it is highly sensitive to mechanical loading, with rapid adaptation to its mechanical environment. These results imply that cartilage grown in culture, with the intention of transplantation, may structurally benefit from an environment of cyclic loading at higher frequencies.
The contribution of the coronoid and radial head to the stability of the elbow
Jeon, In‐Ho , Zhao, Kristin D. , An, Kai‐Nan , Morrey, BF, Sánchez‐Sotelo, Joaquín , Trentadue, Taylor P

Mayo Clinic

The Journal of Bone and Joint Surgery. British volume | January 4, 2012 | Volume: 94-B | Issue: 1 | Pages: 86-92

10.1302/0301-620x.94b1.26530 | PMID 22219253 Get It

We undertook this study to determine the minimum amount of coronoid necessary to stabilise an otherwise intact elbow joint. Regan–Morrey types II and III, plus medial and lateral oblique coronoid fractures, collectively termed type IV fractures, were simulated in nine fresh cadavers. An electromagnetic tracking system defined the three-dimensional stability of the ulna relative to the humerus. The coronoid surface area accounts for 59% of the anterior articulation. Alteration in valgus, internal and external rotation occurred only with a type III coronoid fracture, accounting for 68% of the coronoid and 40% of the entire articular surface. A type II fracture removed 42% of the coronoid articulation and 25% of the entire articular surface but was associated with valgus and external rotational changes only when the radial head was removed, thereby removing 67% of the articular surface. We conclude that all type III fractures, as defined here, are unstable, even with intact ligaments and a radial head. However, a type II deficiency is stable unless the radial head is removed. Our study suggests that isolated medial-oblique or lateral-oblique fractures, and even a type II fracture with intact ligaments and a functional radial head, can be clinically stable, which is consistent with clinical observation.
The effect of core suture flexor tendon repair techniques on gliding resistance during static cycle motion and load to failure: a human cadaver study
Moriya, Tamami, Zhao, Chunfeng , An, Kai‐Nan , Amadio, Peter C. , Larson, Melissa C.

Mayo Clinic

Journal of Hand Surgery (European Volume) | October 10, 2011 | Volume: 37 | Issue: 4 | Pages: 316-322

10.1177/1753193411422793 | PMID 21987278 Get It

The purpose of this study was to describe a modification of the Massachusetts General Hospital (MMGH) tendon repair and to compare it with three other suture techniques. Twenty human flexor digitorum profundus (FDP) tendons were randomly assigned to the modified Pennington (MP) suture and the MMGH suture. These were compared to the modified Kessler (MK) and Massachusetts General Hospital (MGH) sutures, using data from a previous study. All tendons were repaired with a similar epitendinous stitch and core sutures of 4-0 FiberWire. There was no significant difference in the normalized gliding resistance within the two-strand or four-strand core repair groups. The MP suture had significantly higher 2 mm gap force and ultimate load to failure than the MK suture. The MMGH suture had significantly higher 2 mm gap force and maximum failure ultimate load than the MGH suture. All repairs failed by knot unravelling.
Tendon Injury Produces Changes in SSCT and Nerve Physiology Similar to Carpal Tunnel Syndrome in an in Vivo Rabbit Model
Moriya, Tamami, Zhao, Chunfeng , Cha, Stephen S., Schmelzer, James D., Low, Phillip A. , An, Kai‐Nan , Amadio, Peter C. , Cha, Stephen S.

Mayo Clinic

HAND | September 9, 2011 | Volume: 6 | Issue: 4 | Pages: 399-407

10.1007/s11552-011-9356-2 | PMID 23204967 Get It

Background The etiology of carpal tunnel syndrome (CTS) remains idiopathic in many cases. Noninflammatory fibrosis of the subsynovial connective tissue (SSCT) within the carpal tunnel is common in CTS, and some clinicians have hypothesized that this fibrosis might be a cause rather than an effect of CTS. An animal model in which to test this hypothesis would be useful. The principal objective of this study was to investigate the effect of a surgical injury on SSCT fibrosis and median nerve function within the carpal tunnel in an in vivo rabbit model. Methods Rabbits were sacrificed 12 weeks after surgery and were evaluated by mechanical testing, histology, transmission and scanning electron microscopy, and electrophysiology. Results SSCT fibroblast density ( p<0.0001) and collagen fiber size ( p=0.0004) were significantly higher, and the median nerve distal motor amplitude was significantly lower ( p=0.0018), in the tendon injury group SSCT than in either the sham or control groups. Conclusions Our findings are similar to those seen in patients with carpal tunnel syndrome and suggest that the tendon injury procedure may be the basis of a new animal model of SSCT injury and, possibly, CTS.