Citations

Clear

9383 citation(s) found for "Thomas, PS".

Left Ventricular Diastolic Function Is Associated With Symptom Status in Severe Aortic Valve Stenosis
Dahl, Jordi S. , Christensen, Nicolaj Lyhne , Videbæk, Lars , Poulsen, Mikael Kjær , Carter‐Storch, Rasmus , Hey, Thomas Morris , Pellikka, Patricia A. , Steffensen, Flemming Hald , Møller, Jacob Eifer , Pellikka, Patricia A , Dahl, Jordi S , Steffensen, Flemming Hald , Hey, Thomas Morris , Carter-Storch, Rasmus

Mayo Clinic

Circulation: Cardiovascular Imaging | October 31, 2013 | Volume: 7 | Issue: 1 | Pages: 142-148

10.1161/circimaging.113.000636 | PMID 24173271 Get It

Background— In aortic valve stenosis (AS), the occurrence of heart failure symptoms does not always correlate with severity of valve stenosis and left ventricular (LV) function. Therefore, we tested the hypothesis that symptomatic patients with AS have impaired diastolic, longitudinal systolic function, and left atrial dilatation compared with asymptomatic patients. Methods and Results— In a retrospective descriptive study, we compared clinical characteristics and echocardiographic parameters in 99 symptomatic and 139 asymptomatic patients with severe AS and LV ejection fraction ≥50%. Independent predictors of symptomatic state were identified using logistic regression analysis. Symptomatic patients were younger (72±10 versus 76±12 years of age; P =0.002), presented less often with atrial fibrillation (13% versus 24%; P =0.05) and chronic obstructive pulmonary disease (2% versus 19%; P <0.001), and had a lower prevalence of hypertension (73% versus 40%; P <0.001). Despite similar AS severity, symptomatic patients had higher LV mass index (120±39 versus 95±25 g/m 2 ; P <0.0001), increased relative wall thickness (0.61±0.15 versus 0.50±0.11; P <0.0001), shorter mitral deceleration time (199±58 versus 268±62 ms; P <0.0001), and increased left atrial volume index (49±18 versus 42±15 mL/m 2 ; P =0.02). When adjusting for age, history of hypertension, atrial fibrillation, and chronic obstructive pulmonary disease in a multivariable logistic regression analysis, LV mass index, relative wall thickness, left atrial volume index, and deceleration time were still associated with the presence of symptoms. Conclusions— The present study demonstrates that symptomatic status in severe AS is associated with impaired diastolic function, LV hypertrophy, concentric remodeling, and left atrial dilatation when corrected for indices of AS severity. Clinical Trial Registration— URL: http://www.clinicaltrials.gov . Unique identifier: NCT00294775.
DNAJB6 myopathy: A vacuolar myopathy with childhood onset
Suarez‐Cedeño, Gerson , Winder, Thomas , Milone, Margherita

Mayo Clinic

Muscle & Nerve | October 29, 2013 | Volume: 49 | Issue: 4 | Pages: 607-610

10.1002/mus.24106 | PMID 24170373 Get It

Long‐term results of the phase II trial of the oral mTOR inhibitor everolimus (RAD001) in relapsed or refractory Waldenstrom Macroglobulinemia
Ghobrial, Irene M. , LaPlant, Betsy, Hayman, Suzanne R. , Camoriano, John , Lacy, Martha Q. , Bergsagel, P. Leif , Chuma, Stacey, Bergsagel, P. Leif , Witzig, Thomas E. , Gertz, Morie A. , DeAngelo, Daniel J. , Treon, Steven P. , Ghobrial, Irene M

Mayo Clinic

American Journal of Hematology | October 29, 2013 | Volume: 89 | Issue: 3 | Pages: 237-242

10.1002/ajh.23620 | PMID 24716234 Get It

Everolimus is an oral raptor mTOR inhibitor and has shown activity in patients with Waldenstrom's macroglobulinemia (WM). This study examines a large cohort of patients with relapsed/refractory WM with long‐term follow up for survival. Patients were eligible if they had measurable disease, a platelet count >75,000 × 106/L, an absolute neutrophil count >1,000 × 106/L. Patients received everolimus 10 mg PO daily and were evaluated monthly. A success was defined as a complete or partial response (PR); minor responses (MR) were recorded and considered to be of clinical benefit. Sixty patients were enrolled and treated. The overall response rate (ORR) was 50% (all PR); the clinical benefit rate including MR or better was 73% (95% CI: 60–84%) with 23% MR. The median time to response for patients who achieved PR was 2 months (range, 1–26). The median duration of response has not been reached and median progression‐free survival (PFS) was 21 months. Grade 3 or higher toxicities (at least possibly related to everolimus) were observed in 67% of patients. The most common grade 3 or 4 toxicities were anemia (27%), leukopenia (22%), and thrombocytopenia (20%). Other nonhematological toxicities were diarrhea (5%), fatigue (8%), stomatitis (8%) and pulmonary toxicity (5%). Everolimus has a high single‐agent activity of 73% including MR, with a progression free survival of 21 months, indicating that this agent is active in relapsed/refractory WM. Am. J. Hematol. 89:237–242, 2014. © 2013 Wiley Periodicals, Inc
HLA Class II (DR0401) Molecules Induce Foxp3+Regulatory T Cell Suppression of B Cells in Plasmodium yoelii Strain 17XNL Malaria
Wijayalath, Wathsala , Danner, Rebecca , Kleschenko, Yuliya , Majji, Sai , Villasante, Eileen, Richie, Thomas L. , Brumeanu, Teodor-Doru, David, Chella S., Casares, Sofía , Brumeanu, Teodor‐D.

Mayo Clinic

Infection and Immunity | October 29, 2013 | Volume: 82 | Issue: 1 | Pages: 286-297

10.1128/iai.00272-13 | PMID 24166949 Get It

ABSTRACTUnlike human malaria parasites that induce persistent infection, some rodent malaria parasites, likePlasmodium yoeliistrain 17XNL (Py17XNL), induce a transient (self-curing) malaria infection. Cooperation between CD4 T cells and B cells to produce antibodies is thought to be critical for clearance of Py17XNL parasites from the blood, with major histocompatibility complex (MHC) class II molecules being required for activation of CD4 T cells. In order to better understand the correspondence between murine malaria models and human malaria, and in particular the role of MHC (HLA) class II molecules, we studied the ability of humanized mice expressing human HLA class II molecules to clear Py17XNL infection. We showed that humanized mice expressing HLA-DR4 (DR0401) molecules and lacking mouse MHC class II molecules (EA0) have impaired production of specific antibodies to Py17XNL and cannot cure the infection. In contrast, mice expressing HLA-DR4 (DR0402), HLA-DQ6 (DQ0601), HLA-DQ8 (DQ0302), or HLA-DR3 (DR0301) molecules in an EA0background were able to elicit specific antibodies and self-cure the infection. In a series of experiments, we determined that the inability of humanized DR0401.EA0mice to elicit specific antibodies was due to expansion and activation of regulatory CD4+Foxp3+T cells (Tregs) that suppressed B cells to secrete antibodies through cell-cell interactions. Treg depletion allowed the DR0401.EA0mice to elicit specific antibodies and self-cure the infection. Our results demonstrated a differential role of MHC (HLA) class II molecules in supporting antibody responses to Py17XNL malaria and revealed a new mechanism by which malaria parasites stimulate B cell-suppressogenic Tregs that prevent clearance of infection.
Influence of locomotor muscle afferent inhibition on the ventilatory response to exercise in heart failure
Olson, Thomas P. , Joyner, Michael J. , Eisenach, John H., Curry, Timothy B. , Johnson, Bruce D. , Joyner, Michael J

Mayo Clinic

Experimental Physiology | October 26, 2013 | Volume: 99 | Issue: 2 | Pages: 414-426

10.1113/expphysiol.2013.075937 | PMID 24163425 Get It

New FindingsWhat is the central question of this study?Patients with heart failure often develop ventilatory abnormalities at rest and during exercise, but the mechanisms underlying these abnormalities remain unclear. This study investigated the influence of inhibiting afferent neural feedback from locomotor muscles on the ventilatory response during exercise in heart failure patients.What is the main finding and its importance?Our results suggest that inhibiting afferent feedback from locomotor muscle via intrathecal opioid administration significantly reduces the ventilatory response to exercise in heart failure patients.Patients with heart failure (HF) develop ventilatory abnormalities at rest and during exercise, but the mechanism(s) underlying these abnormalities remain unclear. We examined whether the inhibition of afferent neural feedback from locomotor muscles during exercise reduces exercise ventilation in HF patients. In a randomized, placebo‐controlled design, nine HF patients (age, 60 ± 2 years; ejection fraction, 27 ± 2%; New York Heart Association class 2 ± 1) and nine control subjects (age, 63 ± 2 years) underwent constant‐work submaximal cycling (65% peak power) with intrathecal fentanyl (impairing the cephalad projection of opioid receptor‐sensitive afferents) or sham injection. The hypercapnic ventilatory response was measured to determine whether cephalad migration of fentanyl occurred. There were no differences in hypercapnic ventilatory response within or between groups in either condition. Despite a lack of change in ventilation, tidal volume or respiratory rate, HF patients had a mild increase in arterial carbon dioxide () and a decrease in oxygen (;P< 0.05 for both) at rest. The control subjects demonstrated no change in,, ventilation, tidal volume or respiratory rate at rest. In response to fentanyl during exercise, HF patients had a reduction in ventilation (63 ± 6versus44 ± 3 l min−1,P< 0.05) due to a lower respiratory rate (30 ± 1versus26 ± 2 breaths min−1,P< 0.05). The reduced ventilation resulted in lower(97.6 ± 2.5versus79.5 ± 3.0 mmHg,P< 0.05) and increased(37.3 ± 0.9versus43.5 ± 1.1 mmHg,P< 0.05), with significant improvement in ventilatory efficiency (reduction in the ventilatory equivalent for carbon dioxide;P< 0.05 for all). The control subjects had no change in ventilation or measures of arterial blood gases. These data suggest that inhibition of afferent feedback from locomotor muscle significantly reduces the ventilatory response to exercise in HF patients.
Selective modal excitation using phase-shifted ultrasound radiation force
Huber, Thomas M. , Kinnick, Randall R., Greenleaf, James F. , Fatemi, Mostafa

Mayo Clinic

The Journal of the Acoustical Society of America | October 25, 2013 | Volume: 119 | Issue: 5_Supplement | Pages: 3335-3335

10.1121/1.4808905 Get It

The ultrasound radiation force can be used as a noncontact method for exciting vibrational modes. In one implementation, an audio-range modulation signal is combined with a 40-kHz carrier to form a double-sideband suppressed-carrier (DSSC) waveform that is emitted from an ultrasound transducer. The frequency of the ultrasound radiation force is the difference between the frequencies of the sidebands, therefore at twice the modulation frequency. We describe a method for selective mode excitation using a transducer pair, each emitting a DSSC signal. The modulation signal for one transducer was phase shifted relative to the other transducer. When the two modulation signals were in phase, the radiation stress field was uniform. For devices studied, this excited transverse modes while suppressing torsional modes. Similarly, if the modulation signals were out of phase, torsional modes were excited while suppressing transverse modes. This technique has been demonstrated for devices including an MEMS mirror, hard-drive suspension, and brass cantilever. For a cantilever, the ratio of the amplitudes of 180-Hz transverse over 1.3-kHz torsional modes was varied by over two orders of magnitude by shifting the phase difference between the two beams over a range of 90 deg. This noncontact technique allows control over the types of vibration excited.
Noncontact modal testing of hard-drive suspensions using ultrasound radiation force
Huber, Thomas M. , Calhoun, Daniel, Kinnick, Randall R., Greenleaf, James F. , Fatemi, Mostafa

Mayo Clinic

The Journal of the Acoustical Society of America | October 24, 2013 | Volume: 118 | Issue: 3_Supplement | Pages: 1928-1928

10.1121/1.4780706 Get It

The head-gimbal assembly suspension is a cantilever-like structure that holds the heads on a hard drive. We will discuss a noncontact method for modal testing, of suspensions in air, that utilizes the radiation force at the difference frequency generated by two intersecting ultrasound beams. The resulting low-frequency excitations were measured using a scanning vibrometer. This excitation technique has been demonstrated for MEMS and other small devices. There are several unique advantages of the ultrasound radiation force relative to mechanical shakers. Since the ultrasound radiation force is noncontact, a specialized test fixture was not needed; the technique was relatively insensitive to distracting resonances of fixtures and support structures. Another advantage is broadband excitation; a 550-kHz confocal ultrasound transducer excited suspension resonance frequencies from under 1 kHz to over 50 kHz. Other advantages include the ability to selectively excite different modes. For example, the amplitude of the suspension’s 2.28-kHz transverse mode was suppressed by an order of magnitude by shifting the modulation phase between the two ultrasound beams by 90. In another test, the amplitude of the 6.01-kHz torsional mode was doubled by moving the ultrasound focus point from near the center to near the edge of the suspension.
Chronic Eosinophilic Leukemia—Not Otherwise Specified (NOS) in the Background of a Large Cell Lymphoma
Rong, He , Pardanani, Animesh , Smeltzer, Jacob P., Hanson, Curtis A. , Gonsalves, Wilson I. , Gupta, Vinay Kumar , Witzig, Thomas E.

Mayo Clinic

Case Reports in Hematology | October 24, 2013 | Volume: 2013 | Issue: No issue available | Pages: 1-4

10.1155/2013/458303 | PMID 24224106 Get It

Clonal eosinophilic disorders are rare among hematological malignancies. Most eosinophilia tends to be due to secondary causes such as infections, hypersensitivity conditions, drug reactions, and connective tissue disorders. The presence of a primary clonal eosinophilic disorder such as chronic eosinophilic leukemia—not otherwise specified (NOS) in the presence of a synchronous large cell lymphoma—is rare making the diagnosis challenging. We present a case of a 51-year-old female with the aforementioned presentation and demonstrate the extensive workup performed to identify the diagnosis.
Non-contact mode excitation of small structures in air using ultrasound radiation force
Huber, Thomas M. , Purdham, J., Kinnick, Randall R., Greenleaf, James F. , Fatemi, Mostafa

Mayo Clinic

The Journal of the Acoustical Society of America | October 23, 2013 | Volume: 117 | Issue: 4_Supplement | Pages: 2455-2455

10.1121/1.4787149 Get It

With the advent of MEMS, modal analysis of small structures is increasingly important. However, conventional excitation techniques normally require contact, which may not be feasible for small objects. We present a non-contact method that uses interference of ultrasound frequencies in air to produce low-frequency excitation of structures. Objects studied included hard-drive HGA suspensions and MEMS devices. The vibration induced by the ultrasound radiation force was varied in a wide range from 0 Hz to 50 kHz. Object motion was detected using a laser vibrometer; measured frequencies agreed with expected values. Also demonstrated was the unique capability to selectively enhance or suppress modes independently. For example, the ratio of the vibrational amplitudes of the 175 Hz first-bending and 1.33 kHz torsional modes of a small cantilever could be changed from in excess of 10:1 to less than 1:10 by shifting the ultrasound modulation phase 90 degrees. Similar changes were obtained for a 3 mm square MEMS mirror in the ratios of vibration amplitude around its two separate axes. Torsional modes of a hard-drive suspension could be selectively enhanced by over a factor of two by moving the ultrasound focus point from near the center to near the edge of the suspension.
Design aspects of the five string banjo
Rae, James L., Rossing, Thomas D.

Mayo Clinic

The Journal of the Acoustical Society of America | October 23, 2013 | Volume: 117 | Issue: 4_Supplement | Pages: 2590-2590

10.1121/1.4777261 Get It

The five string banjo is a stringed instrument that uses a drum head (membrane) to radiate sound. The strings couple to the head through a moveable bridge. Many have a removable resonator whose spacing from the main part of the banjo is adjustable to allow tuning of the internal air cavity. Holographic interferometry demonstrates vibrational modes of the head that have a strong dependence on head tension. Driving point accelerance measurements demonstrate that the ability of the bridge to be vibrated depends on the mass and stiffness of the materials used in its construction. Peak accelerances usually occur between 1800–2000 Hz. Power spectra measurements of the sound show that 99% of the sound is in a frequency range of 147–5200 Hz. Two substantial formants are seen in the power spectra. The first and largest occurs in about the 400–1800 Hz range, the same frequency range where the most substantial head modes are found. The second is from 2000–4000 Hz, a range where the series combination of bridge and head show increasing accelerances by driving point measurements. Measurements of the transient response following a pluck quantify the frequency content of the rising and falling phase.