Citations

Clear

109 citation(s) found for "Mardini, Samir".

Fleur-de-Lys Myocutaneous Flap for Complex Sacral Reconstruction
Elgendy, Tarek , Bakri, Karim , Kreutz‐Rodrigues, Lucas , Mardini, Samir

Mayo Clinic

Plastic and Reconstructive Surgery - Global Open | May 7, 2021 | Volume: 8 | Issue: 9S | Pages: 117-118

10.1097/01.gox.0000720924.38368.b8 Get It

Understanding Facial Muscle Aging: A Surface Electromyography Study
Cotofana, Sebastian , Assemi-Kabir, Shirin, Giunta, Riccardo E. , Mercado‐Perez, Arnaldo , Lorenc, Z. Paul , Frank, Konstantin , Velthuis, Peter J. , Mercado-Perez, Arnaldo, Cotofana, Sebastian , Mardini, Samir , Gotkin, Robert H. , Moellhoff, Nicholas , Avelar, Luiz Eduardo Toledo , Frank, Konstantin

Mayo Clinic

Aesthetic Surgery Journal | May 4, 2021 | Volume: 41 | Issue: 9 | Pages: NP1208-NP1217

10.1093/asj/sjab202 | PMID 33942051 Get It

Abstract Background Facial aging is a multifactorial process that involves all tissues of the face, including skin, muscles, fat, ligaments, and bone. Whereas robust evidence is available for age-related changes of bone and facial fat, the influence of age on facial muscle activity is poorly understood. Objectives The objective of this study was to investigate the motor unit action potential of facial muscles by utilizing surface-derived, noninvasive electromyography in young and old healthy volunteers. Methods The study investigated a total of 32 healthy volunteers with a mean [standard deviation] age of 42.6 [19.6] years (range, 21-82 years) and a mean BMI of 23.9 [2.7] kg/m2 (range, 18.5-29.7 kg/m2) by performing surface-derived, noninvasive facial electromyography. Nine facial muscles were investigated bilaterally, resulting in a total of 1632 measurements of the signal, baseline noise, and signal-to-noise ratio of these muscles. Results The results of the study revealed that age does not significantly influence the signal (P = 0.234), the baseline noise (P = 0.225), or the signal-to-noise ratio (P = 0.432) of younger individuals (<30 years) vs older individuals (>50 years) in a gender- and BMI-matched statistical model. Exceptions were the zygomaticus major muscle (reduced activity), procerus muscle (increased activity), and corrugator supercilii muscle (increased activity). Conclusions The results of this facial electromyography study may help to increase the understanding of facial aging. Future studies need to reproduce the results presented herein to further increase our understanding of facial aging.
Intraoperative Ultrasound Imaging in Silicone Filler Removal
Suchyta, Marissa , Eiken, Patrick W. , Eiken, Patrick, Hunt, Christopher H. , Mardini, Samir

Mayo Clinic

Journal of Craniofacial Surgery | April 30, 2021 | Volume: 32 | Issue: 3 | Pages: e276-e278

10.1097/scs.0000000000007196 | PMID 34779591 Get It

Abstract Dermal filler injections, one of the most commonly performed procedures in facial esthetic surgery, are rising in popularity. This has also led to an increase in nonmedical grade filler injections performed by nonmedical personnel, including that of injectable silicone. Surgical removal of silicone fillers is challenging, as the hydrophobic material often disperses within the soft tissue as droplets. This can lead to a systemic inflammatory reaction requiring steroid treatment. MRI localization of the filler material does not enable intraoperative guidance, and palpitation of the material is challenging since the filler droplets are often too small to palpate and located in multiple planes. We present a case demonstrating the advantages of utilizing intraoperative ultrasound to localize and silicone filler material. Utilizing this technique, we were able to achieve a high degree of excision of silicone filler material and the patient was able to stop her previous necessary immunosuppressive steroid regimen successfully.
Clinical and Radiological Safety of Retained Implantable Doppler Devices Used for Free Flap Monitoring
Kreutz‐Rodrigues, Lucas , Carlsen, Brian T. , Frick, Matthew A., Bakri, Karim , Gibreel, Waleed , Mardini, Samir

Mayo Clinic

Plastic Surgery | April 27, 2021 | Volume: 30 | Issue: 1 | Pages: 20-24

10.1177/22925503211006537 | PMID 35096688 Get It

Introduction: Implantable Doppler devices are reliable adjuncts used for free flap monitoring. Occasionally, the probe/wire is not removed and remains in the soft tissues. The clinical safety of the retained probes and safety and compatibility with magnetic resonance imaging (MRI) have not been studied. We present a series of retained implantable Doppler probes examining clinic outcomes, safety and compatibility with MRI, and effect on MRI image quality. Methods: A retrospective review was conducted of patients who had an implantable Doppler device for free flap monitoring between July 2007 and August 2018. Routine post-operative imaging was reviewed for all patients to identify incidental findings of a retained probe. A subset of patients with retained implantable Doppler probes who underwent MRI was identified. Magnetic resonance images were reviewed to detect any degradation of image quality. Results: A total of 323 patients who had an implantable Doppler device placed were reviewed 18 (5.6%) patients were identified with a retained probe and were included in this study. Mean age was 49 years with mean follow-up of 34.4 months. One potential device-related complication occurred in 1 (5.6%) patient. A total of 32 MRI scans were performed in 8 patients with retained devices, including 6 patients who underwent a total of 21 MRIs of the surgical site. There were no complications related to the MRI scans, and we found no significant degradation of image quality. Conclusion: Retained implantable Doppler probes were not associated with substantial adverse clinical outcomes nor affected MRI image quality of the surgical site.
Signal-To-Noise Ratio Calculations to Validate Sensor Positioning for Facial Muscle Assessment Using Noninvasive Facial Electromyography
Frank, Konstantin , Alfertshofer, Michael , Patel, Ashit , Smith, Michael P. , Gavril, Diana L., Alfertshofer, Michael , Moellhoff, Nicholas , Kaiser, Antonia , Gotkin, Robert H. , Mardini, Samir , Cotofana, Sebastian

Mayo Clinic

Facial Plastic Surgery | March 8, 2021 | Volume: 37 | Issue: 05 | Pages: 614-624

10.1055/s-0041-1725168 | PMID 33682916 Get It

AbstractThe evaluation of neuromodulator treatment outcomes can be performed by noninvasive surface-derived facial electromyography (fEMG) which can detect cumulative muscle fiber activity deep to the skin. The objective of the present study is to identify the most reliable facial locations where the motor unit action potentials (MUAPs) of various facial muscles can be quantified during fEMG measurements. The study population consisted of five males and seven females (31.0 [12.9] years, body mass index of 22.15 [1.6] kg/m2). Facial muscle activity was assessed in several facial regions in each patient for their respective muscle activity utilizing noninvasive surface-derived fEMG. Variables of interest were the average root mean square of three performed muscle contractions (= signal) (µV), mean root mean square between those contraction with the face in a relaxed facial expression (= baseline noise) (µV), and the signal to noise ratio (SNR). A total of 1,709 processed fEMG signals revealed one specific reliable location in each investigated region based on each muscle's anatomy, on the highest value of the SNR, on the lowest value for the baseline noise, and on the practicability to position the sensor while performing a facial expression. The results of this exploratory study may help guiding future researchers and practitioners in designing study protocols and measuring individual facial MUAP when utilizing fEMG. The locations presented herein were selected based on the measured parameters (SNR, signal, baseline noise) and on the practicability and reproducibility of sensor placement.
Telemedicine in International Cleft Care: A Systematic Review
Bedi, Gurbani , Vyas, Krishna S. , Chung, Michael T. , Morrison, Shane D. , Asaad, Malke , Mardini, Samir

Mayo Clinic

The Cleft Palate Craniofacial Journal | February 5, 2021 | Volume: 58 | Issue: 12 | Pages: 1547-1555

10.1177/1055665621989140 | PMID 33535816 Get It

Background: Cleft lip and cleft palate (CLP) are among the world’s most common congenital malformation and has a higher prevalence in developing nations due to environmental and genetic factors. Global efforts have been developed in order to prevent and treat the malformation. Telemedicine has been implemented in various humanitarian global missions with success and is currently the primary means of care due to COVID-19. Objective: To assess the benefits and barriers of telehealth in the care of patients with CLP through a global approach. Methods: Systematic review of the PubMed and Cochrane Review databases with relevant terms related to telemedicine in cleft lip and palate surgery. Results: Eight articles fit the inclusion criteria and suggested benefits with the use of telemedicine in regard to education, preoperative, and postoperative care as well as increased access to underserved populations. Barriers included connectivity and accessibility concerns. Conclusion: Telehealth is a beneficial way to evaluate patients with CLP in developing countries with proper care and follow-up to reduce complications and to improve health outcomes.
Using Artificial Intelligence to Measure Facial Expression following Facial Reanimation Surgery
Boonipat, Thanapoom , Lin, Jason , Glass, Graeme E. , Stotland, Mitchell A. , Stotland, Mitchell, Asaad, Malke , Mardini, Samir

Mayo Clinic

Plastic & Reconstructive Surgery | October 23, 2020 | Volume: 146 | Issue: 5 | Pages: 1147-1150

10.1097/prs.0000000000007251 | PMID 33136962 Get It

Summary: Social interactions are largely dependent on the interpretation of information conveyed through facial expressions. Although facial reanimation seeks restoration of the facial expression of emotion, outcome measures have not addressed this directly. This study evaluates the use of a machine learning technology to directly measure facial expression before and after facial reanimation surgery. Fifteen study subjects with facial palsy were evaluated both before and after undergoing cross-facial nerve grafting and free gracilis muscle transfer. Eight healthy volunteers were assessed for control comparison. Video footage of subjects with their face in repose and with a posed, closed-lip smile was obtained. The video data were then analyzed using the Noldus FaceReader software application to measure the relative proportions of seven cardinal facial expressions detected within each clip. The facial expression recognition application detected a far greater happy signal in postoperative (42 percent) versus preoperative (13 percent) smile videos (p < 0.0001), compared to 53 percent in videos of control faces smiling. This increase in postoperative happy signal was achieved in exchange for a reduction in the sad signal (15 percent to 9 percent; p = 0.092) and the neutral signal (57 percent to 37 percent; p = 0.0012). For video clips of patients in repose, no significant difference in happy emotion was detected between preoperative (3.1 percent) and postoperative (1.4 percent) states (p = 0.5). This study provides the first proof of concept for the use of a machine learning software application to objectively quantify facial expression before and after surgical reanimation. CLINICAL QUESTION/LEVEL OF EVIDENCE: Diagnostic, IV.
Surgical and Patient-Reported Outcomes in Patients With PEEK Versus Titanium Cranioplasty Reconstruction
Taslakian, Editt N. , Banuelos, Joseph, Bite, Uldis, Sharaf, Basel , Abu-Ghname, Amjed, Sharaf, Basel A , Asaad, Malke , Abu‐Ghname, Amjed , Mardini, Samir , Gompel, Jamie J. Van

Mayo Clinic

Journal of Craniofacial Surgery | October 18, 2020 | Volume: 32 | Issue: 1 | Pages: 193-197

10.1097/scs.0000000000007192 | PMID 33074970 Get It

Background: Several materials are available for cranioplasty reconstruction and consensus regarding the ideal material is lacking. The goal of this study is to present surgical and patient-reported outcomes with PEEK versus Titanium alloplastic cranioplasty. Methods: A retrospective review of all patients who underwent alloplastic cranioplasty with PEEK or Titanium from 2010 to 2017 was conducted. Patient demographics and complications were abstracted and analyzed. Information regarding patient-reported outcomes was collected through a telephone survey. Results: A total of 72 patients (median age 55 years) who underwent 77 cranioplasties were identified (38% PEEK, n = 29; 62% Titanium, n = 48). Overall complication rates were similar between the PEEK (24%, n = 7) and Titanium groups (23%, n = 11), P = 0.902. Similarly, implant failure was similar between the 2 groups (7% in PEEK (n = 2), 13% in Titanium (n = 6), P = 0.703). History of radiation was associated with increased rate of infection in patients with Titanium mesh cranioplasty (38% in radiated patients (n = 3), 3% in nonradiated patients (n = 1), P = 0.012) but not PEEK implants (0% infection rate in radiated patients (n = 0), 15% in nonradiated patients (n = 4), P = 1.000). A total of 24 patients (33% response rate) participated in the telephone survey. All PEEK cranioplasty patients who responded to our survey (n = 13) reported good to excellent satisfaction, while 72% of our titanium mesh cohort (n = 8) described good or excellent satisfaction and 27% (n = 3) reported acceptable result. Conclusion: Cranial reconstruction is associated with high satisfaction among cranioplasty patients with PEEK or Titanium showing comparable complications, failure, and patient-reported satisfaction rates. Patients with history of radiotherapy demonstrated a higher infection rate when titanium mesh was used.
Reply: Fat Graft Enrichment Strategies: A Systematic Review
Vyas, Krishna S. , Vásconez, Henry C., Zielins, Elizabeth R., Bakri, Karim , Morrison, Shane D. , Mardini, Samir

Mayo Clinic

Plastic & Reconstructive Surgery | September 18, 2020 | Volume: 146 | Issue: 6 | Pages: 833e-834e

10.1097/prs.0000000000007411 | PMID 33235003 Get It

A Cadaveric Anatomical and Histological Study of Recipient Intercostal Nerve Selection for Sensory Reinnervation in Autologous Breast Reconstruction
Mohan, Anita T. , Suchyta, Marissa , Vyas, Krishna S. , Lachman, Nirusha , Saint-Cyr, Michael, Mardini, Samir

Mayo Clinic

Journal of Reconstructive Microsurgery | August 30, 2020 | Volume: 37 | Issue: 02 | Pages: 136-142

10.1055/s-0040-1715878 | PMID 32862416 Get It

Abstract Background Autologous breast reconstruction (ABR) has grown in popularity due to improved aesthetic and long-term patient reported outcomes, but data regarding sensory reinnervation of autologous flaps remain limited. Traditionally, the lateral cutaneous branch of the fourth intercostal nerve has been used for flap neurotization, but the use of the anterior cutaneous branch of the intercostal nerves (ACB) offer a more optimal location to the microsurgical field when using internal mammary vessels for the microanastomosis. This study aimed to evaluate the optimum ACB recipient site level for sensory nerve coaptation in ABR. Methods Twelve hemi-chests were dissected from six fresh cadaveric females. Costal cartilages were removed and the anterior cutaneous intercostal nerve (ACB) and the lateral (subcutaneous) division of the anterior cutaneous branch (LACB) of the intercostal nerve were exposed. Anatomical measurements were recorded, and nerve samples were evaluated histologically with carbonic anhydrase staining to differentiate sensory fascicles. Assessment of fascicular diameter, axonal counts, and fascicular area were compared. Results A total of 75 nerve specimens were assessed. The ACB was identified at all levels (100%) and the subcutaneous LACB was noted consistently in the second to fourth rib space (96% cadavers), with a median length of 43, 37.5, and 37 mm, respectively. Across all rib spaces, the fascicular and axonal counts were comparable between the LACB and ACB. Nerves in the second intercostal space had a significantly larger mean fascicular area mean (112,816 ± 157,120 µm2) compared with that in the fourth (mean 26,474 ± 38,626 µm2), p = 0.03. Axonal count of sensory fascicles was the highest in the second intercostal nerves (p < 0.05). Conclusion This study provides anatomical and histological basis to determine the optimum recipient site choice for sensory coaptation in microsurgical breast reconstruction. This would aid in operative decision-making regarding the ideal recipient anterior cutaneous intercostal nerve branches for recipient site coaptation in ABR.