Quantitative, Highly Sensitive Liquid Chromatography–Tandem Mass Spectrometry Method for Detection of Synthetic Corticosteroids
Grebe, Stefan K., Taylor, Robert L. , Singh, Ravinder J.

Mayo Clinic

Clinical Chemistry | October 15, 2004 | Volume: 50 | Issue: 12 | Pages: 2345-2352

10.1373/clinchem.2004.033605 | PMID 15486026 Get It

Abstract Background: Measurements of serum or urine concentrations of synthetic glucocorticoids are useful for assessing suspected iatrogenic hypothalamic-pituitary-adrenal axis suppression and Cushing syndrome. We have developed a liquid chromatography–tandem mass spectrometry (LC-MS/MS) assay for the simultaneous quantitative analysis of beclomethasone dipropionate, betamethasone, budesonide, dexamethasone, fludrocortisone, flunisolide, fluorometholone, fluticasone propionate, megestrol acetate, methylprednisolone, prednisolone, prednisone, triamcinolone, and triamcinolone acetonide. Methods: Stable isotopes of cortisol-9,11,12,12-d4 and triamcinolone-d1 acetonide-d6 were added as internal standards to calibrators, controls, and unknown samples. After acetonitrile precipitation, these samples were extracted with methylene chloride, and the extracts were washed and dried. Reconstituted extract (15 μL) was injected on a reversed-phase column and analyzed by LC-MS/MS in positive-ion mode. Assay precision, accuracy, linearity, and sample stability were determined by use of enriched samples. Clinical validation included analysis of 8 serum and 20 urine samples from patients with undetectable cortisol concentrations and analysis of different types of tablets. Results: Functional assay sensitivity was as low as 0.6–1.6 nmol/L for all compounds except for triamcinolone (7.6 nmol/L). Interassay CVs were 3.0–20% for concentrations of 0.6–364 nmol/L for all analytes. Recoveries of all analytes (except triamcinolone in serum) were 82–138% at 19.2–693 nmol/L. All but one of the serum and urine samples from patients who were tested because of suppressed cortisol concentrations contained at least one synthetic steroid. Tablet analysis recovered 75% of the synthetic steroids in suspected drugs. Conclusions: LC-MS/MS allows simultaneous quantitative detection of various synthetic steroids in serum, plasma, urine, and tablets. This provides a valuable tool for evaluating the clinical effects of topical and systemic synthetic corticosteroids.
Plastic versus Glass Tubes: Effects on Analytical Performance of Selected Serum and Plasma Hormone Assays
Preissner, Carol M., Reilly, William M., Cyr, Richard C, O’Kane, Dennis J., Grebe, Stefan K., Singh, Ravinder

Mayo Clinic

Clinical Chemistry | June 30, 2004 | Volume: 50 | Issue: 7 | Pages: 1245-1247

10.1373/clinchem.2004.034108 | PMID 15229156 Get It

Substitution of 3′-Phosphate Cap with a Carbon-Based Blocker Reduces the Possibility of Fluorescence Resonance Energy Transfer Probe Failure in Real-Time PCR Assays
Cradic, Kendall W, Wells, Jason E. , Kruckeberg, Kent E., Grebe, Stefan K., Allen, Lindsay H. , Singh, Ravinder

Mayo Clinic

Clinical Chemistry | May 25, 2004 | Volume: 50 | Issue: 6 | Pages: 1080-1082

10.1373/clinchem.2004.033183 | PMID 15161729 Get It

Liquid Chromatography–Tandem Mass Spectrometry Assay for Simultaneous Measurement of Estradiol and Estrone in Human Plasma
Nelson, Robert E., Grebe, Stefan K., O’Kane, Dennis J., Singh, Ravinder J.

Mayo Clinic

Clinical Chemistry | February 3, 2004 | Volume: 50 | Issue: 2 | Pages: 373-384

10.1373/clinchem.2003.025478 | PMID 14656902 Get It

Abstract Background: Estradiol (E2) and estrone (E1) measurements form an integral part of the assessment of female reproductive function and have expanding roles in other fields. However, many E1 and E2 immunoassays have limited functional sensitivity, suffer from cross-reactivity, and display poor intermethod agreement. To overcome these problems, we developed a sensitive liquid chromatography–tandem mass spectrometry (LC-MS/MS) assay for the simultaneous measurement of E1 and E2. Methods: After dansyl chloride derivatization, samples were separated by fast gradient chromatography and injected into a tandem mass spectrometer after formation of positive ions with atmospheric pressure chemical ionization. The limits of detection and quantification, recovery, linearity, precision, and reference intervals were determined, and performance was compared with several immunoassays. Results: Total run time per sample was 5 min. The multiple-reaction monitoring ion pairs were m/z 506/171 for 3-dansyl-estradiol and m/z 504/171 for 3-dansyl-estrone. The limits of detection for E1 and E2 were 12.9 pmol/L (3.5 ng/L) and 10.3 pmol/L (2.8 ng/L), respectively. Interassay imprecision (CV) was 4–20% (n = 20). The limits of quantification (functional sensitivities) for E1 and E2 were 44.1 pmol/L (11.9 ng/L) and 23.2 pmol/L (6.3 ng/L), respectively. The assay was linear to >2200 pmol/L (∼600 ng/L) for each analyte. Recoveries were 93–108% for E1 and 100–110% for E2. No cross-reactivity was observed. Method comparison with several immunoassays revealed that the latter were inaccurate and prone to interferences at low E1 and E2 concentrations. Conclusions: LC-MS/MS allows rapid, simultaneous, sensitive, and accurate quantification of E1 and E2 in human serum.