Citations

Clear

768 citation(s) found for "Su, Leon".

Relationship of Late Loss in Lumen Diameter to Coronary Restenosis in Sirolimus-Eluting Stents
O’Malley, A. James , Moses, Jeffrey W. , Leon, Martin B. , Holmes, David R. , Teirstein, Paul S., Schofer, Joachim, Breithardt, Günter, Cutlip, Donald E. , Kereiakes, Dean J. , Shi, Chunxue , Firth, Brian G., Donohoe, Dennis, Kuntz, Richard E., Mauri, Laura , Orav, E. John

Mayo Clinic

Circulation | January 18, 2005 | Volume: 111 | Issue: 3 | Pages: 321-327

10.1161/01.cir.0000153356.72810.97 | PMID 15655127 Get It

Background— Observed rates of restenosis after drug-eluting stenting are low (<10%). Identification of a reliable and powerful angiographic end point will be useful in future trials. Methods and Results— Late loss (postprocedural minimum lumen diameter minus 8-month minimum lumen diameter) was measured in the angiographic cohorts of the SIRIUS (n=703) and E-SIRIUS (n=308) trials. Two techniques, the standard normal approximation and an optimized power transformation, were used to predict binary angiographic restenosis rates and compare them with observed restenosis rates. The mean in-stent late loss observed in the SIRIUS trial was 0.17±0.45 mm (sirolimus) versus 1.00±0.70 mm (control). If a normal distribution was assumed, late loss accurately estimated in-stent binary angiographic restenosis for the control arm (predicted 35.4% versus observed 35.4%) but underestimated it in the sirolimus arm (predicted 0.6% versus observed 3.2%). Power transformation improved the reliability of the estimate in the sirolimus arm (predicted 3.2% [CI 1.0% to 6.7%]) with similar improvements in the E-SIRIUS trial (predicted 4.0% [CI 1.2% to 7.0%] versus observed 3.9%). In the sirolimus-eluting stent arm, in-stent late loss correlated better with target-lesion revascularization than in-segment late loss (c-statistic=0.915 versus 0.665). Conclusions— Because distributions of late loss with a low mean are right-skewed, the use of a transformation improves the accuracy of predicting low binary restenosis rates. Late loss is monotonically correlated with the probability of restenosis and yields a more efficient estimate of the restenosis process in the era of lower binary restenosis rates.
Quantitative Assessment of Angiographic Restenosis After Sirolimus-Eluting Stent Implantation in Native Coronary Arteries
Popma, Jeffrey J. , Leon, Martin B. , Moses, Jeffrey W. , Holmes, David R. , Cox, Nicholas , Fitzpatrick, Michelle, Douglas, John S., Lambert, Charles, Mooney, Michael, Yakubov, Steven, Kuntz, Richard E.

Mayo Clinic

Circulation | December 21, 2004 | Volume: 110 | Issue: 25 | Pages: 3773-3780

10.1161/01.cir.0000150331.14687.4b | PMID 15596568 Get It

Background— Sirolimus-eluting stents (SESs) reduce angiographic restenosis in patients with focal, native coronary artery stenoses. This study evaluated the usefulness of SESs in complex native-vessel lesions at high risk for restenosis. Methods and Results— Angiographic follow-up at 240 days was obtained in 701 patients with long (15- to 25-mm) lesions in small-diameter (2.5- to 3.5-mm) native vessels who were randomly assigned to treatment with SESs or bare-metal stents (BMSs) in the SIRIUS trial. Quantitative angiographic measurements of minimal lumen diameter and percent diameter stenosis were obtained within the treated segment, within the stent, and within its 5-mm proximal and distal edges. Patients treated with SESs had lower rates of binary (>50% diameter stenosis) angiographic restenosis within the segment (8.9% versus 36.3% with the BMS; P <0.001) and within the stent (3.2% versus 35.4% with the BMS; P <0.001). SESs were associated with significantly less late lumen loss within the treated segment, within the stent, and within its 5-mm proximal and distal edges (all P <0.001). The reduction of restenosis with the SES was consistent in patients at risk for restenosis, including those with small vessels, long lesions, and diabetes mellitus. The frequency of late aneurysms was similar in the 2 groups. Conclusions— Compared with BMSs, SESs reduced angiographic late lumen loss within the stent and its adjacent 5-mm margins in patients with complex native-vessel lesions.
Treatment of Left Anterior Descending Coronary Artery Disease With Sirolimus-Eluting Stents
Sawhney, Neil, Moses, Jeffrey W. , Leon, Martin B. , Kuntz, Richard E., Popma, Jeffrey J. , Bachinsky, William , Bass, Theodore A., DeMaio, Samuel J., Fry, Edward T.A., Holmes, David R. , Teirstein, Paul S.

Mayo Clinic

Circulation | July 13, 2004 | Volume: 110 | Issue: 4 | Pages: 374-379

10.1161/01.cir.0000136580.34604.b8 | PMID 15249503 Get It

Background— Revascularization strategies often hinge on the presence and degree of left anterior descending coronary artery (LAD) stenosis. A decision for bypass surgery is often based on the durability of surgical LAD revascularization compared with percutaneous approaches. By decreasing restenosis, drug-eluting stents may have reduced the “reintervention gap” between surgery and percutaneous intervention, making the percutaneous route preferable. Methods and Results— Of the 1101 patients in the SIRIUS trial, 459 with an LAD stenosis were randomized to percutaneous intervention with either sirolimus-eluting or bare-metal stents. Baseline demographic, clinical, and angiographic data were obtained. Patients had 1-year clinical and 8-month angiographic follow-up. Baseline characteristics were similar in both groups. The majority of lesions were tubular type B lesions (69.7%) with a mean diameter of 2.73 mm and a mean length of 14.0 mm. The binary in-stent restenosis rate was 2% for the sirolimus stent group and 41.6% for the bare-metal arm (relative risk, 0.05; 95% CI, 0.02 to 0.1; P <0.001). One-year major adverse events (defined as cardiac death, Q-wave and non–Q-wave myocardial infarction, or target vessel revascularization) was decreased 59% in the sirolimus-stent group (9.8% versus 24.9%; relative risk, 0.39; 95% CI, 0.26 to 0.61; P <0.001). Subgroup analysis of 135 patients with proximal LAD lesions showed similar benefits. In-stent restenosis was 0 in the proximal LAD sirolimus-eluting group (n=67), compared with 38% in the bare-metal arm (n=68), and major adverse events demonstrated a similar trend, with a 50% decrease compared with control patients (10.4% versus 20.6%, P =NS). Conclusions— Sirolimus-eluting stents significantly decrease revascularization rates in LAD lesions. At 1 year, sirolimus-eluting stent revascularization rates are comparable to historic single vessel bypass surgery revascularization rates.
Randomized Study to Evaluate Sirolimus-Eluting Stents Implanted at Coronary Bifurcation Lesions
Moses, Jeffrey W. , Morice, Marie Claude, Ludwig, Josef, Holmes, David R. , Spanos, Vassilis, Louvard, Yves, Desmedt, Benny, Mario, Carlo Di , Leon, Martin B. , Colombo, Antonio , Di Mario, Carlo

Mayo Clinic

Circulation | February 24, 2004 | Volume: 109 | Issue: 10 | Pages: 1244-1249

10.1161/01.cir.0000118474.71662.e3 | PMID 14981005 Get It

Background— A sirolimus-eluting stent (Cypher, Cordis Corp) has been reported to markedly decrease restenosis in selected lesions; higher-risk lesions, including coronary bifurcations, have not been studied. Methods and Results— This prospective study evaluated the safety and efficacy of sirolimus-eluting stents for treatment of coronary bifurcation lesions. Patients were randomly assigned to either stenting of both branches (group A) or stenting of the main branch with provisional stenting of the side branch (SB) (group B). Eighty-five patients (86 lesions) were enrolled. There was 1 case of unsuccessful delivery of any device at the bifurcation site. Given the high crossover, more lesions were treated with 2 stents (n=63) than with stent/balloon (n=22). Clinical follow-up at 6 months was completed in all patients and angiographic follow-up in 53 patients in group A (85.5%) and 21 in group B (95.4%). One patient died suddenly 4.5 months after the procedure. There were 3 cases of stent thrombosis (3.5%). The total restenosis rate at 6 months was 25.7%, and it was not significantly different between the double-stenting (28.0%) and the provisional SB-stenting (18.7%) groups. Fourteen of the restenosis cases occurred at the ostium of the SB and were focal. Target lesion revascularization was performed in 7 cases; target vessel failure occurred in 15 cases (17.6%). Conclusions— These results are an improvement compared with historical controls using bare metal stents. Restenosis at the SB remains a problem. At this time, no statement can be made regarding the most appropriate technique to use when treating bifurcations with the Cypher stent.
Immunoglobulin E and Eosinophil-Dependent Protective Immunity to LarvalOnchocerca volvulusin Mice Immunized with Irradiated Larvae
Abraham, David , Leon, Ofra, Schnyder‐Candrian, Silvia, Wang, Chun , Galioto, Ann Marie, Kerepesi, Laura A., Lee, James J. , Lustigman, Sara

Mayo Clinic

Infection and Immunity | January 24, 2004 | Volume: 72 | Issue: 2 | Pages: 810-817

10.1128/iai.72.2.810-817.2004 | PMID 14742524 Get It

ABSTRACTMice immunized with irradiatedOnchocerca volvulusthird-stage larvae developed protective immunity. Eosinophil levels were elevated in the parasite microenvironment at the time of larval killing, and measurements of total serum antibody levels revealed an increase in the immunoglobulin E (IgE) level in immunized mice. The goal of the present study was to identify the role of granulocytes and antibodies in the protective immune response to the larval stages ofO. volvulusin mice immunized with irradiated larvae. Immunity did not develop in mice if granulocytes, including both neutrophils and eosinophils, were eliminated, nor did it develop if only eosinophils were eliminated. Moreover, larvae were killed in naïve interleukin-5 transgenic mice, and the killing coincided with an increase in the number of eosinophils and the eosinophil peroxidase (EPO) level in the animals. To determine if EPO was required for protective immunity, mice that were genetically deficient in EPO were immunized, and there were no differences in the rates of parasite recovery in EPO-deficient mice and wild-type mice. Two mouse strains were used to study B-cell function; μMT mice lacked all mature B cells, and Xid mice had deficiencies in the B-1 cell population. Immunity did not develop in the μMT mice but did develop in the Xid mice. Finally, protective immunity was abolished in mice treated to eliminate IgE from the blood. We therefore concluded that IgE and eosinophils are required for adaptive protective immunity to larvalO. volvulusin mice.
Long-term outcome of necrotizing pancreatitis treated by necrosectomy
Tsiotos, Gregory G. , León, Enrique Luque-de, Sarr, M. G.

Mayo Clinic

Journal of British Surgery | March 11, 2003 | Volume: 85 | Issue: 12 | Pages: 1650-1653

10.1046/j.1365-2168.1998.00950.x | PMID 9876068 Get It

Abstract Background Long-term functional outcome after operative treatment of necrotizing pancreatitis (NP) has not been studied extensively. Methods Pancreatic function, performance status, recurrence of symptoms and other related problems were analysed in 44 consecutive patients successfully discharged from hospital after operative necrosectomy (1983–1995) and followed up completely for a mean of 5 years. Results Clinical pancreatic insufficiency developed in half the patients. Diabetes mellitus (11 patients), steatorrhoea (six) or both (five) were associated with a mean estimate of 52, 66 and 67 per cent parenchymal necrosis respectively. Normal pancreatic function was associated with 27 per cent parenchymal necrosis (P &lt; 0·05). Diabetes worsened while steatorrhoea tended to improve over time. Abdominal pain and pancreatitis recurred in six and two patients respectively. Performance status worsened in four patients because of recurrent pancreatitis and severe steatorrhoea. Poor long-term performance was associated with a higher Acute Physiology And Chronic Health Evaluation II score on admission (mean 14 versus 9). Conclusion NP has prominent effects on long-term pancreatic exocrine and endocrine function in half the patients, but most preserve a good overall functional status. The development of pancreatic insufficiency varies with the extent of pancreatic parenchymal necrosis.
Long-Term Outcome of Patients Treated With Repeat Percutaneous Coronary Intervention After Failure of γ-Brachytherapy for the Treatment of In-Stent Restenosis
Prpic, Ross, Teirstein, Paul S., Moses, Jeffrey W. , Tripuraneni, Prabhakar, Giorgianni, Joseph-Anthony, Jani, Shirish, Wong, S. Chiu, Fish, R. David, Ellis, Stephen G. , Holmes, David R. , Kereiakas, Dean, Kuntz, Richard E., Leon, Martin B. , Reilly, John P. , Lansky, Alexandra J. , Giorgianni, Joseph

Mayo Clinic

Circulation | October 28, 2002 | Volume: 106 | Issue: 18 | Pages: 2340-2345

10.1161/01.cir.0000036366.62288.74 | PMID 12403664 Get It

Background— Although 192 Ir intracoronary brachytherapy has been demonstrated to dramatically reduce the recurrence of in-stent restenosis, up to 24% of these patients will still require repeat target-vessel revascularization. The short- and long-term outcomes of repeat percutaneous intervention in this population have not been characterized. Methods and Results— Analysis was performed of all patients enrolled in the GAMMA-I and GAMMA-II brachytherapy trials who underwent repeat percutaneous target lesion revascularization (TLR) because of restenosis. Subjects were divided into 2 cohorts: those who had received 192 Ir brachytherapy and those randomized to placebo. Forty-five (17.6%) of a total of 256 patients whose index treatment was intracoronary radiation therapy and 36 (29.8%) of 121 patients whose index treatment was placebo required repeat percutaneous TLR. The mean time to this first TLR was 295±206 days in the irradiated group and 202±167 days in the placebo group ( P =0.03). Acute procedural success occurred in 100% of irradiated patients and 94% of placebo controls ( P =0.19). After the first TLR, a subsequent TLR was required in 15 (33.3%) of 45 brachytherapy patients versus 17 (47.2%) of 36 placebo failure patients ( P =0.26). There was no significant difference in time to second TLR between the 2 groups. Other long-term major adverse event rates in both groups were comparable to those of other contemporary angioplasty/stenting series. Conclusions— In those patients who “fail” 192 Ir intracoronary brachytherapy for in-stent restenosis, treatment with 192 Ir delays the time to first TLR. Additionally, repeat percutaneous intervention in these patients is safe and efficacious in the short term, with acceptable long-term results.
Novel CDC25A Phosphatase Inhibitors from Pyrolysis of 3-α-Azido-B-homo-6-oxa-4-cholesten-7-one on Silica Gel
Peng, Hairuo, Zalkow, Leon H., Abraham, Robert T. , Powis, Garth

Mayo Clinic

Journal of Medicinal Chemistry | July 26, 2002 | Volume: 41 | Issue: 24 | Pages: 4677-4680

10.1021/jm980500r | PMID 9822537 Get It