Citations

Clear

16287 citation(s) found for "Yu, David".

Subconcussive brain vital signs changes predict head-impact exposure in ice hockey players
Fickling, Shaun D. , Smith, Aynsley M., Farrell, Kyle , Pender, Sara C. , Farrell, Kyle J , Stuart, Michael J. , Dodick, David W. , D’Arcy, Ryan C.N.

Mayo Clinic

Brain Communications | March 9, 2021 | Volume: 3 | Issue: 2 | Pages: No page available

10.1093/braincomms/fcab019 | PMID 33855296 Get It

Abstract The brain vital signs framework is a portable, objective, neurophysiological evaluation of brain function at point-of-care. We investigated brain vital signs at pre- and post-season for age 14 or under (Bantam) and age 16–20 (Junior-A) male ice hockey players to (i) further investigate previously published brain vital sign results showing subconcussive cognitive deficits and (ii) validate these findings through comparison with head-impact data obtained from instrumented accelerometers. With a longitudinal study design, 23 male ice hockey players in Bantam (n = 13; age 13.63 ± 0.62) and Tier II Junior-A (n = 10; age 18.62 ± 0.86) divisions were assessed at pre- and post-season. None were diagnosed with a concussion during the season. Cognitive evoked potential measures of Auditory sensation (N100), Basic attention (P300) and Cognitive processing (N400) were analysed as changes in peak amplitudes and latencies (six standard scores total). A regression analysis examined the relationship between brain vital signs and the number of head impacts received during the study season. Significant pre/post differences in brain vital signs were detected for both groups. Bantam and Junior-A players also differed in number of head impacts (Bantam: 32.92 ± 17.68; Junior-A: 195.00 ± 61.08; P < 0.001). Importantly, the regression model demonstrated a significant linear relationship between changes in brain vital signs and total head impacts received (R = 0.799, P = 0.007), with clear differences between the Bantam and Junior-A groups. In the absence of a clinically diagnosed concussion, the brain vital sign changes appear to have demonstrated the compounding effects of repetitive subconcussive impacts. The findings underscored the importance of an objective physiological measure of brain function along the spectrum of concussive impacts.
Determinants and consequences of heart rate and stroke volume response to exercise in patients with heart failure and preserved ejection fraction
Wolsk, Emil , Komtebedde, Jan , Kitzman, Dalane W. , Cleland, John G.F. , Hassager, Christian , Gustafsson, Finn , Hassager, Christian , Gustafsson, Finn , Kaye, David M. , Shah, Sanjiv J , Borlaug, Barry A. , Burkhoff, Daniel , Hasenfuß, Gerd , Møller, Jacob Eifer , Cleland, John G F

Mayo Clinic

European Journal of Heart Failure | March 9, 2021 | Volume: 23 | Issue: 5 | Pages: 754-764

10.1002/ejhf.2146 | PMID 33686716 Get It

Abstract Aims A hallmark of heart failure with preserved ejection fraction (HFpEF) is impaired exercise capacity of varying severity. The main determinant of exercise capacity is cardiac output (CO), however little information is available about the relation between the constituents of CO – heart rate and stroke volume – and exercise capacity in HFpEF. We sought to determine if a heterogeneity in heart rate and stroke volume response to exercise exists in patients with HFpEF and describe possible clinical phenotypes associated with differences in these responses. Methods and results Data from two prospective trials of HFpEF ( n = 108) and a study of healthy participants ( n = 42) with invasive haemodynamic measurements during exercise were utilized. Differences in central haemodynamic responses were analysed with regression models. Chronotropic incompetence was present in 39–56% of patients with HFpEF and 3–56% of healthy participants depending on the definition used, but some ( n = 47, 44%) had an increase in heart rate similar to that of healthy controls. Patients with HFpEF had a smaller increase in their stroke volume index (SVI) (HFpEF: +4 ± 10 mL/m 2 , healthy participants: +24 ± 12 mL/m 2 , P < 0.0001), indeed, SVI fell in 28% of patients at peak exercise. Higher body mass index and lower SVI at rest were associated with smaller increases in heart rate during exercise, whereas higher resting heart rate, and angiotensin‐converting enzyme inhibitor/angiotensin II receptor blocker use were associated with a greater increase in SVI in patients with HFpEF. Conclusion The haemodynamic response to exercise was very heterogeneous among patients with HFpEF, with chronotropic incompetence observed in up to 56%, and 28% had impaired increase in SVI. This suggests that haemodynamic exercise testing may be useful to identify which HFpEF patients may benefit from interventions targeting stroke volume and chronotropic response.
Novel Focal Therapeutic Hypothermia Device for Treatment of Acute Neurologic Injury: Large Animal Safety and Efficacy Trial
Perry, Avital , Graffeo, Christopher S. , Ding, Yong Hong, Jakaitis, Daniel R. , Lu, Aiming , Rodgers, Seth, Kreck, Thomas, Hoofer, Kelly, Gorny, Krzysztof R. , Kadirvel, Ramanathan , Kallmes, David F. , Carlstrom, Lucas P. , Dai, Daying , Ding, Yong H, Ding, Yonghong

Mayo Clinic

Journal of Neurological Surgery Part B: Skull Base | March 9, 2021 | Volume: 83 | Issue: 02 | Pages: 203-209

10.1055/s-0040-1721818 | PMID 35433184 Get It

Abstract Objective Therapeutic hypothermia is a potentially powerful and controversial clinical tool for neuroprotection following acute neurologic pathology, particularly vascular injury. Indeed, therapeutic hypothermia remains a standard of care for postcardiac arrest ischemia and acute neonatal hypoxic-ischemic encephalopathy, improving both survival and outcomes. Although therapeutic hypothermia remains promising for cellular and systems-based neuronal protection in other neurologic injury states, the systemic side effects have limited clinical utility, confounded analysis of potential neurologic benefits, and precluded the completion of meaningful clinical trials. Methods To address such limitations, we developed and tested a novel, minimally invasive, neurocritical care device that employs continuous circulation of cold saline through the pharyngeal region to deliver focal cerebrovascular cooling. We conducted a preclinical safety and efficacy trial in six adult porcine animals to assess the validity and functionality of the NeuroSave device, and assess cooling potential following middle cerebral artery occlusion (n = 2). Results NeuroSave consistently lowered brain parenchymal temperature by a median of 9°C relative to core temperature within 60 minutes of initiation, including in ischemic cerebral parenchyma. The core body temperature experienced a maximal reduction of 2°C, or 5% of body temperature, with no associated adverse effects identified. Conclusion The present study uses a large animal preclinical model to demonstrate the safety and efficacy of a novel, noninvasive device for the induction of robust and systemically safe hypothermia within the brain.
Diagnostic and procedural intraoperative ultrasound: technique, tips and tricks for optimizing results
Lubner, Meghan G. , Gettle, Lori Mankowski , Dahiya, Nirvikar , Pickhardt, Perry J. , Kim, David H. , Ziemlewicz, Timothy J.

Mayo Clinic

The British Journal of Radiology | March 8, 2021 | Volume: 94 | Issue: 1121 | Pages: No page available

10.1259/bjr.20201406 | PMID 33684305 Get It

Intraoperative ultrasound (IOUS) is a valuable adjunctive tool that can provide real-time diagnostic information in surgery that has the potential to alter patient management and decrease complications. Lesion localization, characterization and staging can be performed, as well as surveying for additional lesions and metastatic disease. IOUS is commonly used in the liver for hepatic metastatic disease and hepatocellular carcinoma, in the pancreas for neuroendocrine tumors, and in the kidney for renal cell carcinoma. IOUS allows real-time evaluation of vascular patency and perfusion in organ transplantation and allows for early intervention for anastomotic complications. It can also be used to guide intraoperative procedures such as biopsy, fiducial placement, radiation, or ablation. A variety of adjuncts including microbubble contrast and elastography may provide additional information at IOUS. It is important for the radiologist to be familiar with the available equipment, common clinical indications, technique, relevant anatomy and intraoperative imaging appearance to optimize performance of this valuable imaging modality.
Updating an Empirically Based Tool for Analyzing Congenital Heart Surgery Mortality
Jacobs, Marshall L., Jacobs, Jeffrey P. , Thibault, Dylan, Hill, Kevin D. , Anderson, Brett R. , Karamlou, Tara , Kumar, S. Ram , Mayer, John E. , Mery, Carlos M. , Nathan, Meena , Overman, David M. , Pasquali, Sara K. , Shahian, David M. , O’Brien, Sean M. , Kumar, S Ram , Jacobs, Jeffery P , Eghtesady, Pirooz , Louis, James D. St.

Mayo Clinic

World Journal for Pediatric and Congenital Heart Surgery | March 8, 2021 | Volume: 12 | Issue: 2 | Pages: 246-281

10.1177/2150135121991528 | PMID 33683997 Get It

Objectives: STAT Mortality Categories (developed 2009) stratify congenital heart surgery procedures into groups of increasing mortality risk to characterize case mix of congenital heart surgery providers. This update of the STAT Mortality Score and Categories is empirically based for all procedures and reflects contemporary outcomes. Methods: Cardiovascular surgical operations in the Society of Thoracic Surgeons Congenital Heart Surgery Database (January 1, 2010 – June 30, 2017) were analyzed. In this STAT 2020 Update of the STAT Mortality Score and Categories, the risk associated with a specific combination of procedures was estimated under the assumption that risk is determined by the highest risk individual component procedure. Operations composed of multiple component procedures were eligible for unique STAT Scores when the statistically estimated mortality risk differed from that of the highest risk component procedure. Bayesian modeling accounted for small denominators. Risk estimates were rescaled to STAT 2020 Scores between 0.1 and 5.0. STAT 2020 Category assignment was designed to minimize within-category variation and maximize between-category variation. Results: Among 161,351 operations at 110 centers (19,090 distinct procedure combinations), 235 types of single or multiple component operations received unique STAT 2020 Scores. Assignment to Categories resulted in the following distribution: STAT 2020 Category 1 includes 59 procedure codes with model-based estimated mortality 0.2% to 1.3%; Category 2 includes 73 procedure codes with mortality estimates 1.4% to 2.9%; Category 3 includes 46 procedure codes with mortality estimates 3.0% to 6.8%; Category 4 includes 37 procedure codes with mortality estimates 6.9% to 13.0%; and Category 5 includes 17 procedure codes with mortality estimates 13.5% to 38.7%. The number of procedure codes with empirically derived Scores has grown by 58% (235 in STAT 2020 vs 148 in STAT 2009). Of the 148 procedure codes with empirically derived Scores in 2009, approximately one-half have changed STAT Category relative to 2009 metrics. The New STAT 2020 Scores and Categories demonstrated good discrimination for predicting mortality in an independent validation sample (July 1, 2017-June 30, 2019; sample size 46,933 operations at 108 centers) with C-statistic = 0.791 for STAT 2020 Score and 0.779 for STAT 2020 Category. Conclusions: The updated STAT metrics reflect contemporary practice and outcomes. New empirically based STAT 2020 Scores and Category designations are assigned to a larger set of procedure codes, while accounting for risk associated with multiple component operations. Updating STAT metrics based on contemporary outcomes facilitates accurate assessment of case mix.
Risk Prediction for Delayed Allograft Function: Analysis of the Deterioration of Kidney Allograft Function (DeKAF) Study Data
Matas, Arthur J. , Fieberg, Ann, Leduc, Robert, Gaston, Robert S. , Kasiske, Bertram L. , Hunsicker, Lawrence, Cosio, Fernando, Grande, Joseph P. , Cecka, J. Michael, Connett, John E. , Mannon, Roslyn B. , Mannon, Roslyn B , Helgeson, Erika S. , Rush, David N. , Hunsicker, Lawrence

Mayo Clinic

Transplantation | March 6, 2021 | Volume: 106 | Issue: 2 | Pages: 358-368

10.1097/tp.0000000000003718 | PMID 33675321 Get It

Background. Delayed graft function (DGF) of a kidney transplant results in increased cost and complexity of management. For clinical care or a DGF trial, it would be ideal to accurately predict individual DGF risk and provide preemptive treatment. A calculator developed by Irish et al has been useful for predicting population but not individual risk. Methods. We analyzed the Irish calculator (IC) in the DeKAF prospective cohort (incidence of DGF = 20.4%) and investigated potential improvements. Results. We found that the predictive performance of the calculator in those meeting Irish inclusion criteria was comparable with that reported by Irish et al. For cohorts excluded by Irish: (a) in pump-perfused kidneys, the IC overestimated DGF risk; (b) in simultaneous pancreas kidney transplants, the DGF risk was exceptionally low. For all 3 cohorts, there was considerable overlap in IC scores between those with and those without DGF. Using a modified definition of DGF—excluding those with single dialysis in the first 24 h posttransplant—we found that the calculator had similar performance as with the traditional DGF definition. Studying whether DGF prediction could be improved, we found that recipient cardiovascular disease was strongly associated with DGF even after accounting for IC-predicted risk. Conclusions. The IC can be a useful population guide for predicting DGF in the population for which it was intended but has limited scope in expanded populations (SPK, pump) and for individual risk prediction. DGF risk prediction can be improved by inclusion of recipient cardiovascular disease.
Need for Additional Glaucoma Surgery and Complications Following Glaucoma Drainage Device Surgery
Kung, Felix F. , Knier, Kit , Mejía, Camilo A. , Sargent, Jason, Dogahe, Sepideh Jamali, Sabbagh, Nouran, Hodge, David O. , Khanna, Cheryl L. , Knier, Catherine G, Garmany, Armin , Sargent, Jason M, Jamali Dogahe, Sepideh

Mayo Clinic

Journal of Glaucoma | March 6, 2021 | Volume: 30 | Issue: 6 | Pages: 508-514

10.1097/ijg.0000000000001827 | PMID 33675337 Get It

Précis: In this longitudinal study of patients with open-angle (OAG), pseudoexfoliative (PXE), or neovascular glaucoma (NVG) receiving glaucoma drainage devices (GDD), posttube cumulative rates of reoperation, corneal graft, and visually threatening complications (VT-complications) increased beyond 5 years and were not significantly affected by glaucoma type. Purpose: To study the need for additional glaucoma surgery and development of complications after first GDD surgery in eyes with primary OAG, PXE, or NVG glaucoma. Patients and Methods: There were 306 eyes with OAG (n=185), PXE (n=60), or NVG (n=61) glaucoma who received a first GDD between 1996 and 2017. Outcomes including glaucoma reoperation, corneal graft procedure, and VT-complications after GDD were measured. Kaplan-Meier analysis was used to compare cumulative rate of reaching outcomes over time after GDD placement among the 3 glaucoma groups. Results: When comparing the OAG, PXE, and NVG groups, there were no significant differences in post-GDD cumulative rates of reoperation (P=0.33), corneal graft (P=0.26), or VT-complications (P=0.65) over time. For all eyes, the overall cumulative rates for each outcome measure increased beyond 5 years, and specific Kaplan-Meier rates (5-y, 10-y) included: reoperation (16%, 25%), corneal graft (6%, 12%), VT-complications (9%, 14%). When comparing specific GDDs, the Ahmed FP7 had a higher cumulative reoperation rate over time compared with the Baerveldt 350 (P=0.019). Conclusion: Glaucoma type did not significantly affect post-GDD cumulative rates of reoperation, corneal graft, and VT-complication among the OAG, PXE, and NVG groups. For all eyes, cumulative rates of reoperation, corneal graft, and VT-complications increased beyond 5 years. The Ahmed FP7 had a significantly higher cumulative reoperation rate compared with the Baerveldt 350 over time.
NCCN Guidelines Insights: Non–Small Cell Lung Cancer, Version 2.2021
Ettinger, David S. , Wood, Douglas E. , Aisner, Dara L. , Akerley, Wallace , Bauman, Jessica R. , Bruno, Débora S. , Chirieac, Lucian R. , D’Amico, Thomas A., Dilling, Thomas J. , Dowell, Jonathan E. , Gettinger, Scott , Gubens, Matthew A. , Hegde, Aparna , Hennon, Mark, Lackner, Rudy P., Leal, Ticiana , Lin, Jules , Martins, Renato , Morgensztern, Daniel , Ng, Thomas, Otterson, Gregory A. , Patel, Sandip Pravin , Riely, Gregory J. , Shapiro, Theresa A. , Singh, Aditi P. , Stevenson, James, Tam, Alda L. , Yang, Stephen C. , Gregory, Kristina M., Hughes, Miranda, Schild, Steven E. , Bharat, Ankit , Chang, Joe Y. , Lanuti, Michael D. , Loo, Billy W. , Lovly, Christine Marie , Massarelli, Erminia , Yanagawa, Jane

Mayo Clinic

Journal of the National Comprehensive Cancer Network | March 5, 2021 | Volume: 19 | Issue: 3 | Pages: 254-266

10.6004/jnccn.2021.0013 | PMID 33668021 Get It

The NCCN Clinical Practice Guidelines in Oncology (NCCN Guidelines) for Non–Small Cell Lung Cancer (NSCLC) address all aspects of management for NSCLC. These NCCN Guidelines Insights focus on recent updates to the NCCN Guidelines regarding targeted therapies, immunotherapies, and their respective biomarkers.
Colon Cancer, Version 2.2021, NCCN Clinical Practice Guidelines in Oncology
Benson, Al B. , Al-Hawary, Mahmoud M. , Arain, Mustafa A., Chen, Yi‐Jen , Ciombor, Kristen K. , Cooper, Harry S. , Deming, Dustin A. , Farkas, Linda M., Garrido‐Laguna, Ignacio , Grem, Jean L. , Hecht, J. Randolph, Hoffe, Sarah E. , Hunt, Steven R., Johung, Kimberly L. , Kirilcuk, Natalie, Krishnamurthi, Smitha , Messersmith, Wells A. , Meyerhardt, Jeffrey A. , Mulcahy, Mary F. , Nurkin, Steven, Overman, Michael J. , Patel, Hitendra , Pedersen, Katrina S. , Shibata, David , Skibber, John M., Sofocleous, Constantinos T. , Stotsky‐Himelfarb, Eden, Willett, Christopher G. , Gregory, Kristina M., Gurski, Lisa A., Hubbard, Joleen, Meyerhardt, Jeffrey A , Pedersen, Katrina , Venook, Alan P. , Cohen, Stacey A. , Gunn, Andrew, Hubbard, Joleen M. , Miller, Eric D. , Parikh, Aparna R. , Patel, Hitendra, Saltz, Leonard B. , Schneider, Charles John , Stoffel, Elena M.

Mayo Clinic

Journal of the National Comprehensive Cancer Network | March 5, 2021 | Volume: 19 | Issue: 3 | Pages: 329-359

10.6004/jnccn.2021.0012 | PMID 33724754 Get It

This selection from the NCCN Clinical Practice Guidelines in Oncology (NCCN Guidelines) for Colon Cancer focuses on systemic therapy options for the treatment of metastatic colorectal cancer (mCRC), because important updates have recently been made to this section. These updates include recommendations for first-line use of checkpoint inhibitors for mCRC, that is deficient mismatch repair/microsatellite instability-high, recommendations related to the use of biosimilars, and expanded recommendations for biomarker testing. The systemic therapy recommendations now include targeted therapy options for patients with mCRC that is HER2-amplified, or BRAF V600E mutation–positive. Treatment and management of nonmetastatic or resectable/ablatable metastatic disease are discussed in the complete version of the NCCN Guidelines for Colon Cancer available at NCCN.org . Additional topics covered in the complete version include risk assessment, staging, pathology, posttreatment surveillance, and survivorship.
Comparison of CSF neurofilament light chain, neurogranin, and tau to MRI markers
Przybelski, Scott A. , Lesnick, Timothy G. , Kern, Silke , Blennow, Kaj , Graff‐Radford, Jonathan, Petersen, Ronald C. , Vemuri, Prashanthi , Vemuri, Prashanthi , Mielke, Michelle M. , Zetterberg, Henrik , Knopman, David S. , Graff‐Radford, Jonathan , Jack, Clifford R.

Mayo Clinic

Alzheimer's & Dementia | March 4, 2021 | Volume: 17 | Issue: 5 | Pages: 801-812

10.1002/alz.12239 | PMID 33663022 Get It

AbstractIntroductionWe determined whether cerebrospinal fluid (CSF) neurofilament light (NfL), neurogranin (Ng), and total‐tau (t‐tau) differentially mapped to magnetic resonance imaging (MRI) measures of cortical thickness, microstructural integrity (corpus callosum and cingulum fractional anisotropy [FA]), and white matter hyperintensities (WMH).MethodsAnalyses included 536 non‐demented Mayo Clinic Study of Aging participants with CSF NfL, Ng, t‐tau, amyloid beta (Aβ)42 and longitudinal MRI scans. Linear mixed models assessed longitudinal associations between CSF markers and MRI changes.ResultsHigher CSF NfL was associated with decreasing microstructural integrity and WMH. Higher t‐tau was associated with decreasing temporal lobe and Alzheimer's disease (AD) meta region of interest (ROI) cortical thickness. There was no association between Ng and any MRI measure. CSF Aβ42 interacted with Ng for declines in temporal lobe and AD meta ROI cortical thickness and cingulum FA.DiscussionCSF NfL predicts changes in white matter integrity, t‐tau reflects non‐specific changes in cortical thickness, and Ng reflects AD‐specific synaptic and neuronal degeneration.