Citations

Clear

7542 citation(s) found for "Ho, Matthew".

Kramers–Kronig relationships applied to shear wave propagation in soft tissues.
Amador, Carolina , Greenleaf, James F. , Urban, Matthew W. , Chen, Shigao

Mayo Clinic

The Journal of the Acoustical Society of America | March 23, 2010 | Volume: 127 | Issue: 3_Supplement | Pages: 1731-1731

10.1121/1.3383449 Get It

Multiple methods have been proposed to characterize the viscoelastic material properties of soft tissues to differentiate normal from pathological tissue. Shearwave dispersion ultrasound vibrometry is a method that uses the dispersion of the shear wave velocity to characterize tissue shear elasticity and viscosity. It has recently been shown [M. W. Urban and J. F. Greenleaf, Phys. Med. Biol. 54, 5919–5933 (2009)] that the Kramers–Kronig relationships can be applied to shear wave measurements in ex vivo skeletal muscle over a frequency bandwidth of 100–600 Hz. We will describe this process where shear wave attenuation is modeled using a power law, and the shear wave velocity dispersion is predicted by applying the Kramers–Kronig relationships. In this study, we apply this method to shear wave propagation measurements made in different soft tissues such as ex vivo porcine skeletal muscle and kidney and in vivo porcine liver. The shear wave velocity predictions using the Kramers–Kronig relationships agree with the velocity measurements. The mean square error for these tissues ranged from 0.0024–0.0625 m2/s2. The Kramers–Kronig relationships can be used in shear wave propagation measurements in different types of soft tissues. [This work was supported in part by NIH Grants Nos. EB002167 and DK082408.]
Modulation of ultrasound to produce multifrequency radiation force
Urban, Matthew W. , Fatemi, Mostafa , Greenleaf, James F. , Fatemi, Mostafa , Urban, Matthew W

Mayo Clinic

The Journal of the Acoustical Society of America | March 23, 2010 | Volume: 127 | Issue: 3 | Pages: 1228-1238

10.1121/1.3294487 | PMID 20329821 Get It

Dynamic radiation force has been used in several types of applications, and is performed by modulating ultrasound with different methods. By modulating ultrasound, energy can be transmitted to tissue, in this case a dynamic force to elicit a low frequency cyclic displacement to inspect the material properties of the tissue. In this paper, different types of modulation are explored including amplitude modulation (AM), double sideband suppressed carrier amplitude modulation AM, linear frequency modulation, and frequency-shift keying. Generalized theory is presented for computing the radiation force through the short-term time average of the energy density for these various types of modulation. Examples of modulation with different types of signals including sine waves, square waves, and triangle waves are shown. Using different modulating signals, multifrequency radiation force with different numbers of frequency components can be created, and can be used to characterize tissue mimicking materials and soft tissue. Results for characterization of gelatin phantoms using a method of vibrating an embedded sphere are presented. Different degrees of accuracy were achieved using different modulation techniques and modulating signals. Modulating ultrasound is a very flexible technique to produce radiation force with multiple frequency components that can be used for various applications.
Hockey Education Program (HEP): A Statewide Measure of Fair Play, Skill Development, and Coaching Excellence
Smith, Aynsley M., Jorgenson, M. B., Sorenson, Matthew C., Margenau, David, Link, Andrew A., MacMillan, Michael, Stuart, Michael J.

Mayo Clinic

Fifth International Symposium on Safety in Ice Hockey | March 15, 2010 | Volume: No volume available | Issue: No issue available | Pages: 291-310

10.1520/stp48878s Get It

Following the death of a youth hockey coach in a fight with a parent in 2000, the Mayo Clinic Sports Medicine Center and Minnesota Hockey collaborated to implement a three-component Hockey Education Program (HEP). HEP was initiated in 2003 to ensure youth players develop sportsmanship, skills, and a Fair Play approach to the game. Another goal was to decrease attrition of players, coaches, and officials. Coaching Excellence, a component of HEP, is based on 25 years of youth sport research. The HEP manuals Coaches Who Never Lose and Sports and Your Child contain the philosophy, objectives, and guidelines to ensure implementation of HEP components across players, coaches, and parents. The Skill Development component emphasizes learning age-appropriate hockey skills though skill progression. Increasing the practice-to-game ratio to 3–4 practices per game greatly increases the maximum time players skate with the puck during developmental years. Pre- and post-season Skills Challenges allow coaches, players, and parents to gauge improvement, and structure practices to address identified skill deficits. The Fair Play (FP) component emphasizes sportsmanship. Teams earn a FP point each game if they incur less than a preset number of penalty minutes. A coach receiving a game misconduct or a parent∕spectator asked to leave the game will cause the team to forfeit their FP point. FP points are factored into league standings across the state. This past season, 17 678 records of game data were obtained and 25 % (4420) were randomly selected for analysis. The data analysis permits comparison across seasons and changes are made accordingly. Based on four years of data, most Minnesota youth hockey games are played in a sportsmanlike manner. Checking from behind and head contact penalties have decreased since the penalty minutes for these dangerous infractions were increased.
The Relationship Between Smoking and Replicated Sequence Variants on Chromosomes 8 and 9 With Familial Intracranial Aneurysm
Deka, Ranjan , Koller, Daniel L., Indugula, Subba Rao , Sun, Guangyun, Woo, Daniel , Sauerbeck, Laura, Moomaw, Charles J. , Hornung, Richard, Connolly, E. Sander , Anderson, Craig S. , Meissner, Irene, Bailey‐Wilson, Joan E. , Brown, Robert D., Kleindorfer, Dawn , Flaherty, Matthew L. , Langefeld, Carl D. , Investigators, the FIA Study, Derdeyn, Colin P. , Lai, Dongbing , Rouleau, Guy Armand , Huston, John , Foroud, Tatiana , Broderick, Joseph P. , Investigators, the FIA Study, Wilson, Richard K , Derdeyn, Colin P

Mayo Clinic

Stroke | February 27, 2010 | Volume: 41 | Issue: 6 | Pages: 1132-1137

10.1161/strokeaha.109.574640 | PMID 20190001 Get It

Background and Purpose— The purpose of this study was to replicate the previous association of single nucleotide polymorphisms (SNPs) with risk of intracranial aneurysm (IA) and to examine the relationship of smoking with these variants and the risk of IA. Methods— White probands with an IA from families with multiple affected members were identified by 26 clinical centers located throughout North America, New Zealand, and Australia. White control subjects free of stroke and IA were selected by random digit dialing from the Greater Cincinnati population. SNPs previously associated with IA on chromosomes 2, 8, and 9 were genotyped using a TaqMan assay or were included in the Affymetrix 6.0 array that was part of a genomewide association study of 406 IA cases and 392 control subjects. Logistic regression modeling tested whether the association of replicated SNPs with IA was modulated by smoking. Results— The strongest evidence of association with IA was found with the 8q SNP rs10958409 (genotypic P =9.2×10 −5 ; allelic P =1.3×10 −5 ; OR=1.86, 95% CI: 1.40 to 2.47). We also replicated the association with both SNPs on chromosome 9p, rs1333040 and rs10757278, but were not able to replicate the previously reported association of the 2 SNPs on chromosome 2q. Statistical testing showed a multiplicative relationship between the risk alleles and smoking with regard to the risk of IA. Conclusion— Our data provide complementary evidence that the variants on chromosomes 8q and 9p are associated with IA and that the risk of IA in patients with these variants is greatly increased with cigarette smoking.
MRI After Technically Successful Renal Cryoablation: Early Contrast Enhancement as a Common Finding
Porter, Christopher A. , Woodrum, David A. , Callstrom, Matthew R. , Schmit, Grant D. , Misra, Sanjay , Charboneau, J. William, Atwell, Thomas D. , Misra, Sanjay

Mayo Clinic

American Journal of Roentgenology | February 19, 2010 | Volume: 194 | Issue: 3 | Pages: 790-793

10.2214/ajr.09.2518 | PMID 20173161 Get It

Hydrodisplacement in the Percutaneous Cryoablation of 50 Renal Tumors
Bodily, Kale D., Atwell, Thomas D. , Mandrekar, Jayawant N. , Farrell, Michael A., Callstrom, Matthew R. , Schmit, Grant D. , Charboneau, J. William

Mayo Clinic

American Journal of Roentgenology | February 19, 2010 | Volume: 194 | Issue: 3 | Pages: 779-783

10.2214/ajr.08.1570 | PMID 20173159 Get It

Incidence of Bleeding After 15,181 Percutaneous Biopsies and the Role of Aspirin
Atwell, Thomas D. , Smith, R. L., Hesley, Gina K. , Callstrom, Matthew R. , Schleck, Cathy D. , Harmsen, William S. , Charboneau, J. William, Welch, Timothy J.

Mayo Clinic

American Journal of Roentgenology | February 19, 2010 | Volume: 194 | Issue: 3 | Pages: 784-789

10.2214/ajr.08.2122 | PMID 20173160 Get It

Reply to S.L. Gomez et al
Goetz, Matthew P. , Hoskin, Tanya L. , Boughey, Judy C. , Degnim, Amy C.

Mayo Clinic

Journal of Clinical Oncology | February 17, 2010 | Volume: 28 | Issue: 10 | Pages: e158-e158

10.1200/jco.2009.26.2972 Get It

Short-term repeatability of joint space width measurements using a magnetic resonance imaging compatible knee positioning device
Stanley, Douglas, Weishaar, Paul , Amrami, Kimberly K. , Kaufman, Kenton R. , Koff, Matthew F. , Kaufman, Kenton R

Mayo Clinic

Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine | February 15, 2010 | Volume: 224 | Issue: 9 | Pages: 1061-1071

10.1243/09544119jeim735 | PMID 21053771 Get It

The purpose of this study was to evaluate a magnetic resonance imaging (MRI) compatible knee positioning device to aid in minimizing intratechnologist and intertechnologist differences of minimum joint space width (JSW) measurements. Five subjects were scanned by two separate technologists, with and without an MRI-compatible positioning device. A semi-automated program calculated the minimum JSW of the tibiofemoral and patellofemoral joints. The scan-to-scan repeatability was evaluated from measurements between serial scans without subject repositioning, and the intratechnologist and intertechnologist repeatabilities were evaluated when the subject was removed from the magnet and repositioned by an individual technologist. The root mean square (RMS) error of the JSW measurements was also calculated. All measures of scan-to-scan repeatability and intratechnologist repeatability were unchanged with the MRI-compatible positioning device. The intertechnologist repeatability decreased from 0.70 to 0.42 mm, and the RMS error was significantly reduced ( P = 0.0006) from 0.26 to 0.15 mm for the tibiofemoral joint. The variability of patellofemoral JSW measurements increased when using the positioning device; however, the increases were not statistically significant. The intertechnologist repeatability increased from 1.55 to 1.79 mm, and the RMS error increased from 0.58 to 0.73 mm. The MRI-compatible positioning device was successful at reducing JSW measurement variability at the tibiofemoral joint. The increase in measurement variability at the patellofemoral joint may be due to local incongruities of the articular surfaces. An MRI-compatible positioning device may be beneficial for quantitative longitudinal studies evaluating knee joint health.
Seizure Emergencies in Older Adults
Hoerth, Matthew T., Drazkowski, Joseph F.

Mayo Clinic

Aging Health | February 1, 2010 | Volume: 6 | Issue: 1 | Pages: 97-110

10.2217/ahe.09.91 Get It