Citations

Clear

97 citation(s) found for "Zhao, Chunfeng".

Comparison of Autograft and Allograft with Surface Modification for Flexor Tendon Reconstruction
Wei, Zhuang, Reisdorf, Ramona L., Thoreson, Andrew R. , Moran, Steven L. , An, Kai‐Nan , Amadio, Peter C. , Zhao, Chunfeng , Wei, Zhuang, Jay, Gregory D.

Mayo Clinic

Journal of Bone and Joint Surgery | April 4, 2018 | Volume: 100 | Issue: 7 | Pages: e42

10.2106/jbjs.17.00925 | PMID 29613931 Get It

Background: Flexor tendon injury is common, and tendon reconstruction is indicated clinically if the primary repair fails or cannot be performed immediately after tendon injury. The purpose of the current study was to compare clinically standard extrasynovial autologous graft (EAG) tendon and intrasynovial allogeneic graft (IAG) that had both undergone biolubricant surface modification in a canine in vivo model. Methods: Twenty-four flexor digitorum profundus (FDP) tendons from the second and fifth digits of 12 dogs were used for this study. In the first phase, a model of failed FDP tendon repair was created. After 6 weeks, the ruptured FDP tendons with a scarred digit were reconstructed with the use of either EAG or IAG tendons treated with carbodiimide-derivatized hyaluronic acid and lubricin. At 12 weeks after tendon reconstruction, the digits were harvested for functional, biomechanical, and histologic evaluations. Results: The tendon failure model was a clinically relevant and reproducible model for tendon reconstruction. The IAG group demonstrated improved digit function with decreased adhesion formation, lower digit work of flexion, and improved graft gliding ability compared with the EAG group. However, the IAG group had decreased healing at the distal tendon-bone junction. Our histologic findings verified the biomechanical evaluations and, further, showed that cellular repopulation of allograft at 12 weeks after reconstruction is still challenging. Conclusions: FDP tendon reconstruction using IAG with surface modification has some beneficial effects for reducing adhesions but demonstrated inferior healing at the distal tendon-bone junction compared with EAG. These mixed results indicate that vitalization and turnover acceleration are crucial to reducing failure of reconstruction with allograft. Clinical Relevance: Flexor tendon reconstruction is a common surgical procedure. However, postoperative adhesion formation may lead to unsatisfactory clinical outcomes. In this study, we developed a potential flexor tendon allograft using chemical and tissue-engineering approaches. This technology could improve function following tendon reconstruction.
Rotator cuff repair with a novel mesh suture: An ex vivo assessment of mechanical properties
Zhang, Tao , Thoreson, Andrew R. , Lu, Cheng‐Chang , Steinmann, Scott P. , Moran, Steven L. , Zhao, Chunfeng , Hatta, Taku, Lu, ChengChang, Hatta, Taku

Mayo Clinic

Journal of Orthopaedic Research | August 1, 2017 | Volume: 36 | Issue: 3 | Pages: 987-992

10.1002/jor.23668 | PMID 28762567 Get It

ABSTRACTSurgical repair is a common treatment for rotator cuff tear; however, the retear rate is high. A high degree of suture repair strength is important to ensure rotator cuff integrity for healing. The purpose of this study was to compare the mechanical performance of rotator cuffs repaired with a mesh suture versus traditional polydioxanone suture II and FiberWire sutures in a canine in vitro model. Seventy‐two canine shoulders were harvested. An infraspinatus tendon tear was created in each shoulder. Two suture techniques—simple interrupted sutures and two‐row suture bridge—were used to reconnect the infraspinatus tendon to the greater tuberosity, using three different suture types: Mesh suture, polydioxanone suture II, or FiberWire. Shoulders were loaded to failure under displacement control at a rate of 20 mm/min. Failure load was compared between suture types and techniques. Ultimate failure load was significantly higher in the specimens repaired with mesh suture than with polydioxanone suture II or FiberWire, regardless of suture technique. There was no significant difference in stiffness among the six groups, with the exception that FiberWire repairs were stiffer than polydioxanone suture II repairs with the simple interrupted technique. All specimens failed by suture pull‐out from the tendon. Based on our biomechanical findings, rotator cuff repair with the mesh suture might provide superior initial strength against failure compared with the traditional polydioxanone suture II or FiberWire sutures. Use of the mesh suture may provide increased initial fixation strength and decrease gap formation, which could result in improved healing and lower re‐tear rates following rotator cuff repair. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 36:987–992, 2018.
Ultrasound elastography for carpal tunnel pressure measurement: A cadaveric validation study
Kubo, Kazutoshi, Zhou, Boran , Cheng, Yu‐Shiuan, Yang, Tai‐Hua , Qiang, Bo, An, Kai‐Nan, Moran, Steven L. , Amadio, Peter C. , Zhang, Xiaoming , Zhao, Chunfeng , An, Kai‐Nan , Zhang, Xiaoming

Mayo Clinic

Journal of Orthopaedic Research | July 21, 2017 | Volume: 36 | Issue: 1 | Pages: 477-483

10.1002/jor.23658 | PMID 28731271 Get It

ABSTRACT Carpal tunnel pressure is a key factor in the etiology of carpal tunnel syndrome. Numerous approaches have been conducted to measure carpal tunnel pressure. However, most techniques are invasive and take time and effort. We have developed an innovative approach to noninvasively assess the tunnel pressure by using the ultrasound surface wave elastography (USWE) technique. In a previous study it was shown that the shear wave speed in a tendon increased linearly with increasing tunnel pressure enclosed the tendon in a simple tendon model. This study aimed to examine the relationship between the carpal tunnel pressure and the shear wave speeds inside and outside the carpal tunnel in a human cadaveric model. The result showed that the shear wave speed inside the carpal tunnel increased linearly with created carpal tunnel pressure, while the shear wave speed outside the carpal tunnel remained constant. These findings suggest that noninvasive measurement of carpal tunnel pressure is possible by measuring the shear wave speed in the tendon. After fully establishing this technology and being applicable in clinic, it would be useful in the diagnosis of carpal tunnel syndrome. For that reason, further validation with this technique in both healthy controls and patients with carpal tunnel syndrome is required. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 36:477–483, 2018.
Ultrasound‐guided hydrodissection decreases gliding resistance of the median nerve within the carpal tunnel
Evers, Stefanie, Thoreson, Andrew R. , Smith, Jay , Zhao, Chunfeng , Geske, Jennifer R. , Amadio, Peter C. , Geske, Jennifer

Mayo Clinic

Muscle & Nerve | June 16, 2017 | Volume: 57 | Issue: 1 | Pages: 25-32

10.1002/mus.25723 | PMID 28622409 Get It

ABSTRACTIntroduction: The aim of this study was to assess alterations in median nerve (MN) biomechanics within the carpal tunnel resulting from ultrasound‐guided hydrodissection in a cadaveric model. Methods: Twelve fresh frozen human cadaver hands were used. MN gliding resistance was measured at baseline and posthydrodissection, by pulling the nerve proximally and then returning it to the origin. Six specimens were treated with hydrodissection, and 6 were used as controls. Results: In the hydrodissection group there was a significant reduction in mean peak gliding resistance of 92.9 ± 34.8 mN between baseline and immediately posthydrodissection (21.4% ± 10.5%; P = 0.001). No significant reduction between baseline and the second cycle occurred in the control group: 9.6 ± 29.8 mN (0.4% ± 5.3%; P = 0.467). Discussion: Hydrodissection can decrease the gliding resistance of the MN within the carpal tunnel, at least in wrists unaffected by carpal tunnel syndrome. A clinical trial of hydrodissection seems justified. Muscle Nerve 57: 25–32, 2018
Intramuscular fat infiltration evaluated by magnetic resonance imaging predicts the extensibility of the supraspinatus muscle
Giambini, Hugo , Gorny, Krzysztof R. , Widholm, Per , Karlsson, Anette , Leinhard, Olof Dahlqvist , Adkins, Mark C., Zhao, Chunfeng , An, Kai‐Nan, Hatta, Taku, Hatta, Taku , An, Kai‐Nan

Mayo Clinic

Muscle & Nerve | April 25, 2017 | Volume: 57 | Issue: 1 | Pages: 129-135

10.1002/mus.25673 | PMID 28439938 Get It

ABSTRACTIntroduction: Rotator cuff (RC) tears result in muscle atrophy and fat infiltration within the RC muscles. An estimation of muscle quality and deformation, or extensibility, is useful in selecting the most appropriate surgical procedure. We determined if noninvasive quantitative assessment of intramuscular fat using MRI could be used to predict extensibility of the supraspinatus muscle. Methods: Seventeen cadaveric shoulders were imaged to assess intramuscular fat infiltration. Extensibility and histological evaluations were then performed. Results: Quantitative fat infiltration positively correlated with histological findings and presented a positive correlation with muscle extensibility (r = 0.69; P = 0.002). Extensibility was not significantly different between shoulders graded with a higher fat content versus those with low fat when implementing qualitative methods. Discussion: A noninvasive prediction of whole‐muscle extensibility may directly guide pre‐operative planning to determine if the torn edge could efficiently cover the original footprint while aiding in postoperative evaluation of RC repair. Muscle Nerve 57: 129–135, 2018
The revitalisation of flexor tendon allografts with bone marrow stromal cells and mechanical stimulation
Wu, Jingheng , Thoreson, Andrew R. , Gingery, Anne , An, Kai‐Nan , Moran, Steven L. , Amadio, Peter C. , Zhao, Chunfeng , Gingery, Anne

Mayo Clinic

Bone & Joint Research | March 31, 2017 | Volume: 6 | Issue: 3 | Pages: 179-185

10.1302/2046-3758.63.bjr-2016-0207.r1 | PMID 28360084 Get It

Objectives The present study describes a novel technique for revitalising allogenic intrasynovial tendons by combining cell-based therapy and mechanical stimulation in an ex vivo canine model. Methods Specifically, canine flexor digitorum profundus tendons were used for this study and were divided into the following groups: (1) untreated, unprocessed normal tendon; (2) decellularised tendon; (3) bone marrow stromal cell (BMSC)-seeded tendon; and (4) BMSC-seeded and cyclically stretched tendon. Lateral slits were introduced on the tendon to facilitate cell seeding. Tendons from all four study groups were distracted by a servohydraulic testing machine. Tensile force and displacement data were continuously recorded at a sample rate of 20 Hz until 200 Newton of force was reached. Before testing, the cross-sectional dimensions of each tendon were measured with a digital caliper. Young’s modulus was calculated from the slope of the linear region of the stress-strain curve. The BMSCs were labeled for histological and cell viability evaluation on the decellularized tendon scaffold under a confocal microscope. Gene expression levels of selected extracellular matrix tendon growth factor genes were measured. Results were reported as mean ± SD and data was analyzed with one-way ANOVAs followed by Tukey’s post hoc multiple-comparison test. Results We observed no significant difference in cross-sectional area or in Young’s modulus among the four study groups. In addition, histological sections showed that the BMSCs were aligned well and viable on the tendon slices after two-week culture in groups three and four. Expression levels of several extracellular matrix tendon growth factors, including collagen type I, collagen type III, and matrix metalloproteinase were significantly higher in group four than in group three (p < 0.05). Conclusion Lateral slits introduced into de-cellularised tendon is a promising method of delivery of BMSCs without compromising cell viability and tendon mechanical properties. In addition, mechanical stimulation of a cell-seeded tendon can promote cell proliferation and enhance expression of collagen types I and III in vitro. Cite this article: J. H. Wu, A. R. Thoreson, A. Gingery, K. N. An, S. L. Moran, P. C. Amadio, C. Zhao. The revitalisation of flexor tendon allografts with bone marrow stromal cells and mechanical stimulation: An ex vivo model revitalising flexor tendon allografts. Bone Joint Res 2017;6:179–185. DOI: 10.1302/2046-3758.63.BJR-2016-0207.R1.
Blocking fibrotic signaling in fibroblasts from patients with carpal tunnel syndrome
Yamanaka, Yoshiaki , Gingery, Anne , Oki, Gosuke, Yang, Tai‐Hua , Zhao, Chunfeng , Amadio, Peter C. , Gingery, Anne

Mayo Clinic

Journal of Cellular Physiology | March 10, 2017 | Volume: 233 | Issue: 3 | Pages: 2067-2074

10.1002/jcp.25901 | PMID 28294324 Get It

Fibrosis of the subsynovial connective tissue (SSCT) in carpal tunnel syndrome (CTS) patients is increasingly recognized as an important aspect of CTS pathophysiology. In this study, we evaluated the effect of blocking profibrotic pathways in fibroblasts from the SSCT in CTS patients. Fibroblasts were stimulated with transforming growth factor β1 (TGF‐β1), and then treated either with a specific fibrosis pathway inhibitor targeting TGF‐β receptor type 1 (TβRI), platelet‐derived growth factor receptor (PDGFR), epidermal growth factor receptor (EGFR), or vascular endothelial growth factor receptor (VEGFR). Fibrosis array and quantitative real‐time polymerase chain reaction of fibrotic genes were evaluated. Array gene expression analysis revealed significant down‐regulation of multiple fibrotic genes after treatment with TβRI, PDGFR, and VEGFR inhibitors. No array fibrotic genes were significantly down‐regulated with EGFR inhibition. Further gene expression analysis of known CTS fibrosis markers collagen type I A2 (Col1), collagen type III A1 (Col3), connective tissue growth factor (CTGF), and SERPINE1 showed significantly down‐regulation after TβRI inhibition. In contrast, VEGFR inhibition significantly down‐regulated CTGF and SERPINE1, whereas, PDGFR and EGFR inhibition significantly down‐regulated Col3. Taken together the inhibition of TβRI appears to be the primary mediator of fibrotic gene expression in fibroblasts from CTS patients. TGF‐β/Smad activity was further evaluated, and as expected inhibition of Smad activity was significantly down‐regulated after inhibition of TβRI, but not with PDGFR, VEGFR, or EGFR inhibition. These results indicate that local therapies specifically targeting TGF‐β signaling alone or in combination offer the potential of a novel local antifibrosis therapy for patients with CTS.
Quantitative Computed Tomography Protocols Affect Material Mapping and Quantitative Computed Tomography-Based Finite-Element Analysis Predicted Stiffness
Giambini, Hugo , Dragomir‐Daescu, Dan , Yaszemski, Michael J. , Zhao, Chunfeng , Nassr, Ahmad

Mayo Clinic

Journal of Biomechanical Engineering | July 18, 2016 | Volume: 138 | Issue: 9 | Pages: No page available

10.1115/1.4034172 | PMID 27428281 Get It

Quantitative computed tomography-based finite-element analysis (QCT/FEA) has become increasingly popular in an attempt to understand and possibly reduce vertebral fracture risk. It is known that scanning acquisition settings affect Hounsfield units (HU) of the CT voxels. Material properties assignments in QCT/FEA, relating HU to Young's modulus, are performed by applying empirical equations. The purpose of this study was to evaluate the effect of QCT scanning protocols on predicted stiffness values from finite-element models. One fresh frozen cadaveric torso and a QCT calibration phantom were scanned six times varying voltage and current and reconstructed to obtain a total of 12 sets of images. Five vertebrae from the torso were experimentally tested to obtain stiffness values. QCT/FEA models of the five vertebrae were developed for the 12 image data resulting in a total of 60 models. Predicted stiffness was compared to the experimental values. The highest percent difference in stiffness was approximately 480% (80 kVp, 110 mAs, U70), while the lowest outcome was ∼1% (80 kVp, 110 mAs, U30). There was a clear distinction between reconstruction kernels in predicted outcomes, whereas voltage did not present a clear influence on results. The potential of QCT/FEA as an improvement to conventional fracture risk prediction tools is well established. However, it is important to establish research protocols that can lead to results that can be translated to the clinical setting.
Comparison of Passive Stiffness Changes in the Supraspinatus Muscle After Double‐Row and Knotless Transosseous‐Equivalent Rotator Cuff Repair Techniques: A Cadaveric Study
Giambini, Hugo , Hooke, Alexander W. , Zhao, Chunfeng , Sperling, John W. , Steinmann, Scott P. , Yamamoto, Nobuyuki , Itoi, Eiji, An, Kai‐Nan , Hatta, Taku, Hatta, Taku

Mayo Clinic

Arthroscopy | May 4, 2016 | Volume: 32 | Issue: 10 | Pages: 1973-1981

10.1016/j.arthro.2016.02.024 | PMID 27157656 Get It

Purpose To investigate the alteration of passive stiffness in the supraspinatus muscle after double‐row (DR) and knotless transosseous‐equivalent (KL‐TOE) repair techniques, using shear wave elastography (SWE) in cadavers with rotator cuff tears. We also aimed to compare altered muscular stiffness after these repairs to that obtained from shoulders with intact rotator cuff tendon. Methods Twelve fresh‐frozen cadaveric shoulders with rotator cuff tear (tear size: small [6], medium‐large [6]) were used. Passive stiffness of 4 anatomic regions in the supraspinatus muscle was measured based on an established SWE method. Each specimen underwent DR and KL‐TOE footprint repairs at 30° glenohumeral abduction. SWE values, obtained at 0°, 10°, 20°, 30°, 60°, and 90° abduction, were assessed in 3 different conditions: preoperative (torn) and postoperative conditions with the 2 techniques. The increased ratio of SWE values after repair was compared among the 4 regions to assess stiffness distribution. In addition, SWE values were obtained on 12 shoulders with intact rotator cuff tendons as control. Results In shoulders with medium‐large‐sized tears, supraspinatus muscles showed an increased passive stiffness after rotator cuff repairs, and this was significantly observed at adducted positions. KL‐TOE repair showed uniform stiffness changes among the 4 regions of the supraspinatus muscle (mean, 189% to 218% increase after repair), whereas DR repair caused a significantly heterogeneous stiffness distribution within the muscle (mean, 187% to 319% after repair, P = .002). Although a repair‐induced increase in muscle stiffness was observed also in small‐sized tears, there were no significant differences in repaired stiffness changes between DR and KL‐TOE (mean, 127% to 138% and 127% to 130% after repairs, respectively). Shoulders with intact rotator cuff tendon showed uniform SWE values among the 4 regions of the supraspinatus muscle (mean, 38.2 to 43.0 kPa). Conclusions Passive stiffness of the supraspinatus muscle increases after rotator cuff repairs for medium‐large‐sized tears. KL‐TOE technique for the medium‐large‐sized tear provided a more uniform stiffness distribution across the repaired supraspinatus muscles compared with the DR technique. Clinical Relevance Based on this insight, investigating rotator cuff muscle stiffness changes, further studies using SWE may determine the optimal repair technique for various sizes of rotator cuff tears.
THE EFFECT OF FREEZING ON BIOMECHANICAL PROPERTIES OF THE CARPAL TUNNEL SUBSYNOVIAL CONNECTIVE TISSUE
Filius, Anika , Thoreson, Andrew R. , Dharan, Abhishek, Mara, Kristin C. , An, Kai‐Nan , Zhao, Chunfeng , Amadio, Peter C. , Mara, Kristin C

Mayo Clinic

Journal of Musculoskeletal Research | April 7, 2016 | Volume: 18 | Issue: 04 | Pages: 1550019

10.1142/s0218957715500190 Get It

Biomechanical evaluation of the subsynovial connective tissue (SSCT) provides insight into the causes of carpal tunnel syndrome. Studies of carpal tunnel mechanics have been performed using fresh-frozen cadaver tissue. Freezing can affect mechanical properties of some tissues, but its effect on SSCT is unknown. A total of 16 rabbit paws were harvested from eight New Zealand rabbits and subjected to mechanical testing consisting of three repeated tendon excursions in sets of three different excursion magnitudes. One paw from each animal was unfrozen. The contralateral paw was frozen and thawed before testing. Force, energy and stiffness of the first cycle of each set were evaluated, as were ratios of the second to first cycle for each parameter. Two-factor ANOVA with repeated measures over both factors was performed. No significant interactions between factors were found. There were no significant differences between fresh and frozen paws for any parameters, though there were significant differences between excursion amplitudes. The damage threshold was not different between fresh and frozen paws. This study demonstrated that freezing rabbit subsynovial connective tissue does not significantly change its mechanical properties. The same may be true for human cadaver tissues. Results of cadaver mechanical testing may not be influenced by this preservation technique.