Technical Note: Treatment planning system (TPS) approximations matter — comparing intensity‐modulated proton therapy (IMPT) plan quality and robustness between a commercial and an in‐house developed TPS for nonsmall cell lung cancer (NSCLC)
PurposeApproximate dose calculation methods were used in the nominal dose distribution and the perturbed dose distributions due to uncertainties in a commercial treatment planning system (CTPS) for robust optimization in intensity‐modulated proton therapy (IMPT). We aimed to investigate whether the approximations influence plan quality, robustness, and interplay effect of the resulting IMPT plans for the treatment of locally advanced lung cancer patients.Materials and methodsTen consecutively treated locally advanced nonsmall cell lung cancer (NSCLC) patients were selected. Two IMPT plans were created for each patient using our in‐house developed TPS, named “Solo,” and also the CTPS, EclipseTM (Varian Medical Systems, Palo Alto, CA, USA), respectively. The plans were designed to deliver prescription doses to internal target volumes (ITV) drawn by a physician on averaged four‐dimensional computed tomography (4D‐CT). Solo plans were imported back to CTPS, and recalculated in CTPS for fair comparison. Both plans were further verified for each patient by recalculating doses in the inhalation and exhalation phases to ensure that all plans met clinical requirements. Plan robustness was quantified on all phases using dose‐volume‐histograms (DVH) indices in the worst‐case scenario. The interplay effect was evaluated for every plan using an in‐house developed software, which randomized starting phases of each field per fraction and accumulated dose in the exhalation phase based on the patient's breathing motion pattern and the proton spot delivery in a time‐dependent fashion. DVH indices were compared using Wilcoxon rank‐sum test.ResultsCompared to the plans generated using CTPS on the averaged CT, Solo plans had significantly better target dose coverage and homogeneity (normalized by the prescription dose) in the worst‐case scenario [ITV D95%: 98.04% vs 96.28%, Solo vs CTPS, P = 0.020; ITV D5%–D95%: 7.20% vs 9.03%, P = 0.049] while all DVH indices were comparable in the nominal scenario. On the inhalation phase, Solo plans had better target dose coverage and cord Dmax in the nominal scenario [ITV D95%: 99.36% vs 98.45%, Solo vs CTPS, P = 0.014; cord Dmax: 20.07 vs 23.71 Gy(RBE), P = 0.027] with better target coverage and cord Dmax in the worst‐case scenario [ITV D95%: 97.89% vs 96.47%, Solo vs CTPS, P = 0.037; cord Dmax: 24.57 vs 28.14 Gy(RBE), P = 0.037]. On the exhalation phase, similar phenomena were observed in the nominal scenario [ITV D95%: 99.63% vs 98.87%, Solo vs CTPS, P = 0.037; cord Dmax: 19.67 vs 23.66 Gy(RBE), P = 0.039] and in the worst‐case scenario [ITV D95%: 98.20% vs 96.74%, Solo vs CTPS, P = 0.027; cord Dmax: 23.47 vs 27.93 Gy(RBE), P = 0.027]. In terms of interplay effect, plans generated by Solo had significantly better target dose coverage and homogeneity, less hot spots, and lower esophageal Dmean, and cord Dmax [ITV D95%: 101.81% vs 98.68%, Solo vs CTPS, P = 0.002; ITV D5%–D95%: 2.94% vs 7.51%, P = 0.002; cord Dmax: 18.87 vs 22.29 Gy(RBE), P = 0.014].ConclusionsSolo‐generated IMPT plans provide improved cord sparing, better target robustness in all considered phases, and reduced interplay effect compared with CTPS. Consequently, the approximation methods currently used in commercial TPS programs may have space for improvement in generating optimal IMPT plans for patient cases with locally advanced lung cancer.
Dosimetric comparison of distal esophageal carcinoma plans for patients treated with small‐spot intensity‐modulated proton versus volumetric‐modulated arc therapies
BackgroundEsophageal carcinoma is the eighth most common cancer in the world. Volumetric‐modulated arc therapy (VMAT) is widely used to treat distal esophageal carcinoma due to high conformality to the target and good sparing of organs at risk (OAR). It is not clear if small‐spot intensity‐modulated proton therapy (IMPT) demonstrates a dosimetric advantage over VMAT. In this study, we compared dosimetric performance of VMAT and small‐spot IMPT for distal esophageal carcinoma in terms of plan quality, plan robustness, and interplay effects.Methods35 distal esophageal carcinoma patients were retrospectively reviewed; 19 patients received small‐spot IMPT and the remaining 16 of them received VMAT. Both plans were generated by delivering prescription doses to clinical target volumes (CTVs) on phase‐averaged 4D‐CT's. The dose‐volume‐histogram (DVH) band method was used to quantify plan robustness. Software was developed to evaluate interplay effects with randomized starting phases for each field per fraction. DVH indices were compared using Wilcoxon rank‐sum test. For fair comparison, all the treatment plans were normalized to have the same CTVhigh D95% in the nominal scenario relative to the prescription dose.ResultsIn the nominal scenario, small‐spot IMPT delivered statistically significantly lower liver Dmean and V30Gy[RBE], lung Dmean, heart Dmean compared with VMAT. CTVhigh dose homogeneity and protection of other OARs were comparable between the two treatments. In terms of plan robustness, the IMPT and VMAT plans were comparable for kidney V18Gy[RBE], liver V30Gy[RBE], stomach V45Gy[RBE], lung Dmean, V5Gy[RBE], and V20Gy[RBE], cord Dmax and , liver Dmean, heart V20Gy[RBE], and V30Gy[RBE], but IMPT was significantly worse for CTVhigh D95%, , and D5%‐D95%, CTVlow D95%, heart Dmean, and V40Gy[RBE], requiring careful and experienced adjustments during the planning process and robustness considerations. The small‐spot IMPT plans still met the standard clinical requirements after interplay effects were considered.ConclusionsSmall‐spot IMPT decreases doses to heart, liver, and total lung compared to VMAT as well as achieves clinically acceptable plan robustness. Our study supports the use of small‐spot IMPT for the treatment of distal esophageal carcinoma.
Expression of ICOSL is associated with decreased survival in invasive breast cancer
BackgroundInducible co-stimulator (ICOS) is a CD28-related molecule exclusively expressed on activated T cells and plays a critical role in modulating the immune response in breast cancer. The blockage of ICOS pathway has been shown to inhibit the activity of Type 2 T helper cells, thus potentially protecting against cancer growth. The current study aims to investigate the correlation between inducible co-stimulator ligand (ICOSL) expression in tumor tissues and the prognoses of patients with invasive breast cancer.MethodsTumor samples from 562 Chinese patients with invasive breast carcinomas were collected between 2003 and 2010. The expression of ICOSL on breast tumor and adjacent non-cancerous tissue was determined via immunohistochemistry. The overall survival (OS) of patients with positive and negative ICOSL expression were described using Kaplan–Meier curves, respectively. Parametric correlation method was used to analyze the correlation between ICOSL expression and other clinicopathological parameters. ICOSL was selected as a dependent variable for multivariate analysis.ResultsPositive ICOSL expression was identified on the plasma membrane in both cytoplasm and the nucleus of breast cancer cells. Membrane-expressed ICOSL is determined as an independent prognostic factor for OS in breast cancer but without significantly correlating with other clinicopathologic parameters such as age, menopausal status, depth of invasion, lymph node metastasis status, histologic classification, etc.ConclusionOur study suggests that the up-regulated expression of ICOSL protein in breast tumor cells can be associated with poor prognoses in invasive breast carcinomas.
Nascent Lung Organoids Reveal Epithelium- and Bone Morphogenetic Protein–mediated Suppression of Fibroblast Activation
Abstract Reciprocal epithelial–mesenchymal interactions are pivotal in lung development, homeostasis, injury, and repair. Organoids have been used to investigate such interactions, but with a major focus on epithelial responses to mesenchyme and less attention to epithelial effects on mesenchyme. In the present study, we used nascent organoids composed of human and mouse lung epithelial and mesenchymal cells to demonstrate that healthy lung epithelium dramatically represses transcriptional, contractile, and matrix synthetic functions of lung fibroblasts. Repression of fibroblast activation requires signaling via the bone morphogenetic protein (BMP) pathway. BMP signaling is diminished after epithelial injury in vitro and in vivo, and exogenous BMP4 restores fibroblast repression in injured organoids. In contrast, inhibition of BMP signaling in healthy organoids is sufficient to derepress fibroblast matrix synthetic function. Our results reveal potent repression of fibroblast activation by healthy lung epithelium and a novel mechanism by which epithelial loss or injury is intrinsically coupled to mesenchymal activation via loss of repressive BMP signaling.
Dosimetric analysis of distal esophageal adenocarcinoma patients treated by intensity-modulated proton therapy with small spot size.
159 Background: Intensity-modulated proton therapy (IMPT) with small spot size has the potential to reduce dose to normal tissues but also introduces new confounding factors such as setup uncertainty, range uncertainty, and interplay effects due to breathing motion. We investigated plan quality and robustness of IMPT with small spot size for distal esophageal adenocarcinoma (DEA). Methods: 19 patients with DEA treated by IMPT were retrospectively evaluated. Spot sizes ranged from 2 to 6mm, with spot spacing of 5mm. All plans were generated using a commercial treatment planning system. In-house-developed dose-evaluation software modeled time-dependent spot delivery to incorporate interplay effects. Dose-volume-histogram (DVH) indices were used to evaluate plan quality and robustness was evaluated using the DVH band method. Results: For plan quality, median values of clinical target volume D95% and D5%-D95% (normalized to the prescribed doses), total lung mean dose, heart mean dose, and cord Dmax were 1.014, 0.035, 3.82Gy[RBE], 7.73Gy[RBE], 39.16Gy[RBE], respectively. For plan robustness, median band widths of the aforementioned DVH indices were 0.018, 0.048, 0.60Gy[RBE], 4.17Gy[RBE], and 2.36Gy[RBE], respectively. For interplay effects, median values of the aforementioned DVH indices were 0.99, 0.061, 4.07Gy[RBE], 7.87Gy[RBE], and 39.66Gy[RBE], respectively. Seven patients underwent esophagectomy after neoadjuvant chemoradiation, and five, three, and one of them achieved downstaging, near complete response, and pathologic complete response, respectively; R0 resection was achieved in all cases. For all patients, acute side effects were mostly limited to grades 1-2 only. The only grade 3 adverse events were related to feeding tube placement (8 patients); there were no RT-induced pneumonitis or other lung-related toxicities. Conclusions: IMPT plans with small spot size for DEA have good target dose coverage, homogeneity and normal tissue protection. Treatment plans are also robust to uncertainties and interplay effects. Early clinical results demonstrate low acute toxicity and encouraging clinical and pathologic response.
A novel and individualized robust optimization method using normalized dose interval volume constraints (NDIVC) for intensity‐modulated proton radiotherapy
PurposeIntensity‐modulated proton therapy (IMPT) is known to be sensitive to patient setup and range uncertainty issues. Multiple robust optimization methods have been developed to mitigate the impact of these uncertainties. Here, we propose a new robust optimization method, which provides an alternative way of robust optimization in IMPT, and is clinically practical, which will enable users to control the balance between nominal plan quality and plan robustness in a user‐defined fashion.MethodWe calculated nine individual dose distributions which corresponded to one nominal and eight extreme scenarios caused by patient setup and proton beam's range uncertainties. For each voxel, the normalized dose interval (NDI) is defined as the full dose range variation divided by the maximum dose in all uncertainty scenarios (NDI = [max – min dose]/max dose), which was then used to calculate the normalized dose interval volume histogram (NDIVH) curves. The areas under the NDIVH curves were used to quantify plan robustness. A normalized dose interval volume constraint (NDIVC) applied to the target was incorporated to specify the desired robustness which was user‐defined. Users could then explore the trade‐off between nominal plan quality and plan robustness by adjusting the position of the NDIVCs on the NDIVH curves freely. We benchmarked our method using one lung, five head and neck (H&N), and three prostate cases by comparing our results to those derived using the voxel‐wise worst‐case robust optimization.ResultsUsing the benchmark cases, our new method achieved quality IMPT plans comparable to those derived from the voxel‐wise worst‐case robust optimization for both nominal plan quality and plan robustness in general; even more conformal and more homogeneous target dose distributions in some cases, if proper NDIVCs were applied. The AUC under NDIVH, as a precise quantitative index of plan robustness, was consistent with DVH bandwidths. Additionally, we demonstrated the feasibility of adjusting the position of NDIVCs in the NDIVH curves which allowed users to explore the trade‐off between nominal plan quality and plan robustness.ConclusionsThe NDIVH‐based robust optimization method provided a novel and individualized way of robust optimization in IMPT, and enables users to adjust the balance between nominal plan quality and plan robustness in a user‐defined fashion. This method is applicable for continued improvement and developing the next generation of IMPT planning algorithms in the future.
Automation of routine elements for spot‐scanning proton patient‐specific quality assurance
PurposeAt our institution, all proton patient plans undergo patient‐specific quality assurance (PSQA) prior to treatment delivery. For intensity‐modulated proton beam therapy, quality assurance is complex and time consuming, and it may involve multiple measurements per field. We reviewed our PSQA workflow and identified the steps that could be automated and developed solutions to improve efficiency.MethodsWe used the treatment planning system's (TPS) capability to support C# scripts to develop an Eclipse scripting application programming interface (ESAPI) script and automate the preparation of the verification phantom plan for measurements. A local area network (LAN) connection between our measurement equipment and shared database was established to facilitate equipment control, measurement data transfer, and storage. To improve the analysis of the measurement data, a Python script was developed to automatically perform a 2D–3D γ‐index analysis comparing measurements in the plane of a two‐dimensional detector array with TPS predictions in a water phantom for each acquired measurement.ResultsDevice connection via LAN granted immediate access to the plan and measurement information for downstream analysis using an online software suite. Automated scripts applied to verification plans reduced time from preparation steps by at least 50%; time reduction from automating γ‐index analysis was even more pronounced, dropping by a factor of 10. On average, we observed an overall time savings of 55% in completion of the PSQA per patient plan.ConclusionsThe automation of the routine tasks in the PSQA workflow significantly reduced the time required per patient, reduced user fatigue, and frees up system users from routine and repetitive workflow steps allowing increased focus on evaluating key quality metrics.
Small‐spot intensity‐modulated proton therapy and volumetric‐modulated arc therapies for patients with locally advanced non‐small‐cell lung cancer: A dosimetric comparative study
AbstractPurposeTo compare dosimetric performance of volumetric‐modulated arc therapy (VMAT) and small‐spot intensity‐modulated proton therapy for stage III non‐small‐cell lung cancer (NSCLC).Methods and MaterialsA total of 24 NSCLC patients were retrospectively reviewed; 12 patients received intensity‐modulated proton therapy (IMPT) and the remaining 12 received VMAT. Both plans were generated by delivering prescription doses to clinical target volumes (CTV) on averaged 4D‐CTs. The dose‐volume‐histograms (DVH) band method was used to quantify plan robustness. Software was developed to evaluate interplay effects with randomized starting phases of each field per fraction. DVH indices were compared using Wilcoxon rank sum test.ResultsCompared with VMAT, IMPT delivered significantly lower cord Dmax, heart Dmean, and lung V5 Gy[RBE] with comparable CTV dose homogeneity, and protection of other OARs. In terms of plan robustness, the IMPT plans were statistically better than VMAT plans in heart Dmean, but were statistically worse in CTV dose coverage, cord Dmax, lung Dmean, and V5 Gy[RBE]. Other DVH indices were comparable. The IMPT plans still met the standard clinical requirements with interplay effects considered.ConclusionsSmall‐spot IMPT improves cord, heart, and lung sparing compared to VMAT and achieves clinically acceptable plan robustness at least for the patients included in this study with motion amplitude less than 11 mm. Our study supports the usage of IMPT to treat some lung cancer patients.
Intertumoral Heterogeneity of CD3+ and CD8+ T-Cell Densities in the Microenvironment of DNA Mismatch-Repair–Deficient Colon Cancers: Implications for Prognosis
Abstract Purpose: Colorectal cancers with deficient DNA mismatch repair (dMMR) are presumed to uniformly have dense lymphocytic infiltration that underlies their favorable prognosis and is critical to their responsiveness to immunotherapy, as compared with MMR-proficient (pMMR) tumors. We examined T-cell densities and their potential heterogeneity in a large cohort of dMMR tumors. Experimental Design: CD3+ and CD8+ T-cell densities were quantified at the invasive margin (IM) and tumor core (CT) in 561 stage III colon cancers (dMMR, n = 278; pMMR, n = 283) from a phase III adjuvant trial (N0147). Their association with overall survival (OS) was determined using multivariable Cox analysis. Results: Although CD3+ and CD8+ T-cell densities in the tumor microenvironment were higher in dMMR versus pMMR tumors overall, intertumoral heterogeneity in densities between tumors was significantly higher by 30% to 88% among dMMR versus pMMR cancers (P < 0.0001 for all four T-cell subtypes [CD3+IM, CD3+CT, CD8+IM, CD8+CT]). A substantial proportion of dMMR tumors (26% to 35% depending on the T-cell subtype) exhibited T-cell densities as low as that in the bottom half of pMMR tumors. All four T-cell subtypes were prognostic in dMMR with CD3+IM being the most strongly prognostic. Low (vs. high) CD3+IM was independently associated with poorer OS among dMMR (HR, 4.76; 95% confidence interval, 1.43–15.87; P = 0.0019) and pMMR tumors (P = 0.0103). Conclusions: Tumor-infiltrating T-cell densities exhibited greater intertumoral heterogeneity among dMMR than pMMR colon cancers, with CD3+IM providing robust stratification of both dMMR and pMMR tumors for prognosis. Potentially, lower T-cell densities among dMMR tumors may contribute to immunotherapy resistance.