Strain Dyssynchrony Index Correlates With Improvement in Left Ventricular Volume After Cardiac Resynchronization Therapy Better Than Tissue Velocity Dyssynchrony Indexes
Background— Various dyssynchrony indexes derived from tissue velocity and strain imaging have been proposed to predict the effectiveness of cardiac resynchronization therapy (CRT). We sought to compare the effect of CRT on dyssynchrony indexes derived by tissue velocity and strain and to determine which baseline intraventricular dyssynchrony parameters correlate with improvement in left ventricular volume after CRT. Methods and Results— Echocardiography with tissue Doppler imaging was performed in 45 patients with systolic heart failure at baseline, 1 day after CRT, and a median of 6 months after CRT. We calculated septal–lateral delay and anteroseptal–posterior delay and standard deviation of time to peak systolic velocity in the 12 basal and mid-left ventricular segments (Tv-SD). The standard deviation for time to peak strain in the 12 basal and mid-left ventricular segments (Tε-SD) was calculated as a strain-derived dyssynchrony index. None of the tissue velocity–derived dyssynchrony indexes improved after CRT (septal–lateral delay, P =0.39; anteroseptal–posterior delay, P =0.46; Tv-SD, P =0.30), whereas Tε-SD decreased significantly after CRT ( P <0.001). Improvement in Tε-SD 1 day after CRT correlated with the reduction in end-systolic volume at follow-up ( r =0.66; P <0.001). Baseline Tε-SD demonstrated significant correlation with the reduction of end-systolic volume at follow-up ( r =0.57; P <0.001); however, baseline tissue velocity–derived dyssynchrony indexes failed to predict the effect of CRT. Conclusions— The strain-derived dyssynchrony index is a better measurement than the tissue velocity dyssynchrony index for monitoring changes in mechanical dyssynchrony after CRT and for predicting reduction in left ventricular volume after CRT.
Aspirin Responsiveness in Healthy Volunteers Measured with Multiple Assay Platforms
Abstract Background: We evaluated the sensitivity, precision, and concordance of 4 assays designed to detect aspirin responsiveness or resistance. Methods: Twenty-nine healthy laboratory volunteers took 80 mg aspirin for 7 days, and a subset of volunteers took 325 mg aspirin for an additional 7 days. We measured platelet function by light transmission aggregometry with arachidonic acid, PFA-100, and VerifyNow. PFA-100 and VerifyNow assays were performed in duplicate to assess method imprecision. Some volunteers had samples taken within 2–4 h of the final dose of aspirin and again within 20–24 h of the final dose. We measured urinary 11-dehydro-thromboxane B2 at baseline and after 80 or 325 mg aspirin. Results: No volunteers were nonresponsive to aspirin therapy as measured by the PFA-100. One of 29 participants demonstrated lack of response to aspirin as measured by VerifyNow and urinary 11-dehydro-thromboxane B2; 2 of 29 demonstrated lack of response as measured by light transmission aggregometry. Imprecision was <10% for the PFA-100 and VerifyNow. Concordance was high (>90%) between all assays. Neither aspirin dose (80 vs 325 mg) nor timing between final dose of aspirin and blood draw (2–4 vs 20–24 h) affected any of the assays. Conclusions: Light transmission aggregometry, PFA-100, VerifyNow, and urinary 11-dehydro-thromboxane B2 are all sensitive to the effects of aspirin in healthy individuals. Variables such as aspirin dose, timing between final dose of aspirin and blood collection, and imprecision do not affect the ability of the assays to detect aspirin effect on platelet function.
Can Serum β-Hydroxybutyrate Be Used to Diagnose Diabetic Ketoacidosis?
OBJECTIVE—Current criteria for the diagnosis of diabetic ketoacidosis (DKA) are limited by their nonspecificity (serum bicarbonate [HCO3] and pH) and qualitative nature (the presence of ketonemia/ketonuria). The present study was undertaken to determine whether quantitative measurement of a ketone body anion could be used to diagnose DKA. RESEARCH DESIGN AND METHODS—A retrospective review of records from hospitalized diabetic patients was undertaken to determine the concentration of serum β-hydroxybutyrate (βOHB) that corresponds to a HCO3 level of 18 mEq/l, the threshold value for diagnosis in recently published consensus criteria. Simultaneous admission βOHB and HCO3 values were recorded from 466 encounters, 129 in children and 337 in adults. RESULTS—A HCO3 level of 18 mEq/l corresponded with βOHB levels of 3.0 and 3.8 mmol/l in children and adults, respectively. With the use of these threshold βOHB values to define DKA, there was substantial discordance (∼≥20%) between βOHB and conventional diagnostic criteria using HCO3, pH, and glucose. In patients with DKA, there was no correlation between HCO3 and glucose levels on admission and a significant but weak correlation between βOHB and glucose levels (P < 0.001). CONCLUSIONS—Where available, serum βOHB levels ≥3.0 and ≥3.8 mmol/l in children and adults, respectively, in the presence of uncontrolled diabetes can be used to diagnose DKA and may be superior to the serum HCO3 level for that purpose. The marked variability in the relationship between βOHB and HCO3 is probably due to the presence of other acid-base disturbances, especially hyperchloremic, nonanion gap acidosis.
Evaluation of the Impact of Hematocrit and Other Interference on the Accuracy of Hospital-Based Glucose Meters