Comparison of Direct Colony Method versus Extraction Method for Identification of Gram-Positive Cocci by Use of Bruker Biotyper Matrix-Assisted Laser Desorption Ionization–Time of Flight Mass Spectrometry
ABSTRACT We evaluated Bruker Biotyper (version 2.0) matrix-assisted laser desorption ionization–time of flight (MALDI-TOF) mass spectrometry (MS) for the identification of 305 clinical isolates of staphylococci, streptococci, and related genera by comparing direct colony testing with preparatory extraction. Isolates were previously identified by use of phenotypic testing and/or 16S rRNA gene sequencing. Manufacturer-specified score cutoffs for genus- and species-level identification were used. After excluding 7 isolates not present in the Biotyper library, the Biotyper correctly identified 284 (95%) and 207 (69%) isolates to the genus and species levels, respectively, using extraction. By using direct colony testing, the Biotyper identified 168 (56%) and 60 (20%) isolates to the genus and species levels, respectively. Overall, more isolates were identified to the genus and species levels with preparatory extraction than with direct colony testing ( P < 0.0001). The analysis was repeated after dividing the isolates into two subgroups, staphylococci, streptococci, and enterococci ( n = 217) and “related genera” ( n = 81). For the former subgroup, the extraction method resulted in the identification of 213 (98%) and 171 (79%) isolates to the genus and species levels, respectively, whereas the direct colony method identified 136 (63%) and 56 (26%) isolates to the genus and species levels, respectively. In contrast, for the subgroup of related genera, the extraction method identified 71 (88%) and 36 (44%) isolates to the genus and species levels, respectively, while the direct colony method identified 32 (40%) and 4 (5%) isolates to the genus and species levels, respectively. For both subgroups, preparatory extraction was superior to direct colony testing for the identification of isolates to the genus and species levels ( P < 0.0001). Preparatory extraction is needed for the identification of a substantial proportion of Gram-positive cocci using the Biotyper method according to manufacturer-specified score cutoffs.
Comparison of Bruker Biotyper Matrix-Assisted Laser Desorption Ionization–Time of Flight Mass Spectrometer to BD Phoenix Automated Microbiology System for Identification of Gram-Negative Bacilli
ABSTRACT We compared the BD Phoenix automated microbiology system to the Bruker Biotyper (version 2.0) matrix-assisted laser desorption ionization–time of flight (MALDI-TOF) mass spectrometry (MS) system for identification of Gram-negative bacilli, using biochemical testing and/or genetic sequencing to resolve discordant results. The BD Phoenix correctly identified 363 (83%) and 330 (75%) isolates to the genus and species level, respectively. The Bruker Biotyper correctly identified 408 (93%) and 360 (82%) isolates to the genus and species level, respectively. The 440 isolates were grouped into common (308) and infrequent (132) isolates in the clinical laboratory. For the 308 common isolates, the BD Phoenix and Bruker Biotyper correctly identified 294 (95%) and 296 (96%) of the isolates to the genus level, respectively. For species identification, the BD Phoenix and Bruker Biotyper correctly identified 93% of the common isolates (285 and 286, respectively). In contrast, for the 132 infrequent isolates, the Bruker Biotyper correctly identified 112 (85%) and 74 (56%) isolates to the genus and species level, respectively, compared to the BD Phoenix, which identified only 69 (52%) and 45 (34%) isolates to the genus and species level, respectively. Statistically, the Bruker Biotyper overall outperformed the BD Phoenix for identification of Gram-negative bacilli to the genus ( P < 0.0001) and species ( P = 0.0005) level in this sample set. When isolates were categorized as common or infrequent isolates, there was statistically no difference between the instruments for identification of common Gram-negative bacilli ( P > 0.05). However, the Bruker Biotyper outperformed the BD Phoenix for identification of infrequently isolated Gram-negative bacilli ( P < 0.0001).
Three-Hour Molecular Detection of
Campylobacter
,
Salmonella
,
Yersinia
, and
Shigella
Species in Feces with Accuracy as High as Tha
ABSTRACT Campylobacter jejuni and Salmonella , Shigella , and Yersinia species (along with Shiga toxin-producing Escherichia coli ) are the most common causes of acute bacterial diarrheal disease in the United States. Current detection techniques are time-consuming, limiting usefulness for patient care. We developed and validated a panel of rapid PCR assays for the detection and identification of C. jejuni , C. coli , Salmonella , and Yersinia species and Shigella and enteroinvasive E. coli in stool samples. A total of 392 archived stool specimens, previously cultured for enteric pathogens, were evaluated by PCR. Overall, 104 stool specimens had been culture positive ( C. jejuni / coli [ n = 51], Salmonella species [ n = 42], Shigella species [ n = 6], and Yersinia species [ n = 5]). Compared to culture, the overall sensitivity and specificity of PCR detection of these organisms were 92 and 98% (96/104 and 283/288), respectively, from fresh or Cary Blair stool ( P = 0.41); 87 and 98% (41/47 and 242/246), respectively, from fresh stool ( P = 0.53); and 96 and 98% (55/57 and 41/42), respectively, from Cary Blair stool ( P = 0.56). For individual genera, PCR was as sensitive as the culture method, with the exception of Salmonella culture using selenite enrichment for which PCR was less sensitive than culture from fresh, but not Cary Blair ( P = 0.03 and 1.00, respectively) stools. This PCR assay panel for the rapid diagnosis of acute infectious bacterial diarrheal pathogens has a sensitivity and specificity equivalent to that of culture for stools in Cary Blair transport medium. Paired with reflexive culture of stools testing positive, this should provide an improvement in care for patients with acute infectious diarrheal disease.
ABSTRACT Prosthetic valve endocarditis is an uncommon manifestation of infection with Bartonella species. Herein, we report a case of Bartonella henselae endocarditis involving prosthetic mitral and aortic valves. The patient had a favorable outcome with combined medical and surgical therapy. Concomitant crescentic glomerulonephritis led to an initial mistaken diagnosis of Wegener's granulomatosis.